Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Braz Oral Res ; 38: e091, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39258602

RESUMO

The aim of this study was to evaluate the wettability and adhesion of self-organized TiO2 nanotubes formed on the surface of 8 commercially pure titanium (CP-Ti) disks and 12 dental implants (n = 12) by anodization in a glycerol-H2O (50-50 v/v) electrolyte containing NH4F. Two disk specimens were not submitted to anodization (controls). The nanotubes thus obtained had average dimensions of 50 nm in diameter by 900 nm in length. The treated disk specimens were stored for 2, 14 and 35 days (n = 2), and the wettability of their surfaces was evaluated with a goniometer at the end of each storing period. The adhesion of nanotubes to titanium was evaluated by field emission scanning electron microscopy after subjecting the 12 implants to a simulation of clinical stress in two-part synthetic bone blocks. After installing the implants with the application of an insertion torque, the two halves of the block were separated, and the implants were removed. The nanotubes remained adhered to the substrate, with no apparent deformation. The contact angles after 14 days and 35 days were 16.47° and 17.97°, respectively, values significantly higher than that observed at 2 days, which was 9.24° (p < 0.05). It was concluded that the method of anodic oxidation tested promoted the formation of a surface suitable for clinical use, containing nanotubes with levels of wettability and adhesion to titanium compatible with those obtained by other methods found in the literature. The wettability, however, did not prove stable over the tested storage periods.


Assuntos
Implantes Dentários , Teste de Materiais , Microscopia Eletrônica de Varredura , Nanotubos , Oxirredução , Propriedades de Superfície , Titânio , Molhabilidade , Titânio/química , Fatores de Tempo , Nanotubos/química , Reprodutibilidade dos Testes , Valores de Referência , Análise de Variância , Estatísticas não Paramétricas
2.
Int J Oral Maxillofac Implants ; 31(3): 665-71, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27183076

RESUMO

PURPOSE: The aim of this study was to evaluate the volumetric stability of deproteinized bovine bone after sinus augmentation, using cone beam computed tomography (CBCT) and three-dimensional (3D) analysis. MATERIALS AND METHODS: Using a specific selection tool and 3D reconstruction from InVesalius 3.0, volumetric analysis of CBCT scans was performed in patients undergoing a sinus elevation technique in critical defects, using deproteinized bovine bone. The first scan was performed immediately after graft surgery (T1), and the second was performed 8 months after graft surgery (T2). RESULTS: A total of 13 patients met the inclusion criteria of this retrospective study; 26 postoperative CBCT scans were analyzed for these patients. All patients exhibited an increase in bone volume (9.10%). The mean bone volume increase from T1 to T2 was 0.137 cm(3) (SD: ± 0.104 cm(3)). There was a statistically significant correlation between bone volume and time (P < .0001). The mean bone volume was 1.506 cm(3) (SD: ± 0.473 cm(3)) for T1 and 1.644 cm(3) (SD: ± 0.506 cm(3)) for T2. CONCLUSION: Within the limited sample, the study demonstrated an increase in graft volume after sinus elevation with deproteinized bovine bone in critical defects.


Assuntos
Transplante Ósseo/métodos , Seio Maxilar/cirurgia , Boca Edêntula/reabilitação , Levantamento do Assoalho do Seio Maxilar/métodos , Adulto , Animais , Bovinos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Transplante Heterólogo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa