Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 297: 120747, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39033790

RESUMO

The anatomy of the human piriform cortex (PC) is poorly understood. We used a bimodal connectivity-based-parcellation approach to investigate subregions of the PC and its connectional differentiation from the amygdala. One hundred (55 % female) genetically unrelated subjects from the Human Connectome Project were included. A region of interest (ROI) was delineated bilaterally covering PC and amygdala, and functional and structural connectivity of this ROI with the whole gray matter was computed. Spectral clustering was performed to obtain bilateral parcellations at granularities of k = 2-10 clusters and combined bimodal parcellations were computed. Validity of parcellations was assessed via their mean individual-to-group similarity per adjusted rand index (ARI). Individual-to-group similarity was higher than chance in both modalities and in all clustering solutions. The amygdala was clearly distinguished from PC in structural parcellations, and olfactory amygdala was connectionally more similar to amygdala than to PC. At higher granularities, an anterior and ventrotemporal and a posterior frontal cluster emerged within PC, as well as an additional temporal cluster at their boundary. Functional parcellations also showed a frontal piriform cluster, and similar temporal clusters were observed with less consistency. Results from bimodal parcellations were similar to the structural parcellations. Consistent results were obtained in a validation cohort. Distinction of the human PC from the amygdala, including its olfactory subregions, is possible based on its structural connectivity alone. The canonical fronto-temporal boundary within PC was reproduced in both modalities and with consistency. All obtained parcellations are freely available.


Assuntos
Tonsila do Cerebelo , Conectoma , Córtex Piriforme , Humanos , Feminino , Masculino , Córtex Piriforme/anatomia & histologia , Córtex Piriforme/diagnóstico por imagem , Córtex Piriforme/fisiologia , Adulto , Conectoma/métodos , Tonsila do Cerebelo/anatomia & histologia , Tonsila do Cerebelo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Vias Neurais/anatomia & histologia , Vias Neurais/diagnóstico por imagem , Adulto Jovem , Rede Nervosa/diagnóstico por imagem , Rede Nervosa/anatomia & histologia
2.
Nervenarzt ; 90(12): 1232-1238, 2019 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-31654235

RESUMO

The idiopathic Parkinson's disease (iPD) is a progressive neurodegenerative disorder primarily resulting in impaired movement execution. In the course of the disease symptom fluctuation is common and makes adequate treatment difficult. In this overview the current approaches using modern and especially mobile technologies for diagnosis, monitoring and treatment of iPD are presented. Currently, there are no medical aids ready for point of care application; however, the development of these technologies has great potential for improving care for patients suffering from iPD.


Assuntos
Doença de Parkinson , Consulta Remota , Humanos , Doença de Parkinson/diagnóstico , Doença de Parkinson/terapia , Consulta Remota/tendências
3.
Neurol Res Pract ; 5(1): 33, 2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37559161

RESUMO

BACKGROUND: Mobile gait sensors represent a compelling tool to objectify the severity of symptoms in patients with idiopathic Parkinson's disease (iPD), but also to determine the therapeutic benefit of interventions. In particular, parameters of Deep Brain stimulation (DBS) with its short latency could be accurately assessed using sensor data. This study aimed at gaining insight into gait changes due to different DBS parameters in patients with subthalamic nucleus (STN) DBS. METHODS: An analysis of various gait examinations was performed on 23 of the initially enrolled 27 iPD patients with chronic STN DBS. Stimulation settings were previously adjusted for either amplitude, frequency, or pulse width in a randomised order. A linear mixed effects model was used to analyse changes in gait speed, stride length, and maximum sensor lift. RESULTS: The findings of our study indicate significant improvements in gait speed, stride length, and leg lift measurable with mobile gait sensors under different DBS parameter variations. Notably, we observed positive results at 85 Hz, which proved to be more effective than often applied higher frequencies and that these improvements were traceable across almost all conditions. While pulse widths did produce some improvements in leg lift, they were less well tolerated and had inconsistent effects on some of the gait parameters. Our research suggests that using lower frequencies of DBS may offer a more tolerable and effective approach to enhancing gait in individuals with iPD. CONCLUSIONS: Our results advocate for lower stimulation frequencies for patients who report gait difficulties, especially those who can adapt their DBS settings remotely. They also show that mobile gait sensors could be incorporated into clinical practice in the near future.

4.
Ultraschall Med ; 33(5): 474-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23070933

RESUMO

PURPOSE: Ultrasound elastography by acoustic radiation force impulse imaging (ARFI) is used in adults for non invasive measurement of liver stiffness, indicating liver diseases like fibrosis. To establish ARFI in children and adolescents we determined standard values of healthy liver tissue and analysed potentially influencing factors. MATERIALS AND METHODS: 132 patients between 0 and 17 years old were measured using ARFI. None of them had any liver disease or any other disease that could affect the liver secondarily. All patients had a normal ultrasound scan, a normal BMI and normal liver function tests. The mean value of all ARFI measurements was calculated and potentially influencing factors were analysed. RESULTS: The mean value of all ARFI elastography measurements was 1.16 m/sec (SD ±â€Š0.14 m/sec). Neither age (p = 0.533) nor depth of measurement (p = 0.066) had no significant influence on ARFI values, whereas a significant effect of gender was found with lower ARFI values in females (p = 0.025), however, there was no significant interaction between age groups (before or after puberty) and gender (p = 0.276). There was an interlobar difference with lower values in the right liver lobe compared to the left (p = 0.036) and with a significantly lower variance (p < 0.001). Consistend values were measured by different examiners (p = 0.108), however, the inter examiner variance deviated significantly (p < 0.001). CONCLUSION: ARFI elastography is a reliable method to measure liver stiffness in children and adolescents. In relation to studies which analyse liver diseases, the standard value of 1.16 m/sec (±â€Š0.14 m/sec) allows a differentiation of healthy versus pathological liver tissue.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Fígado/diagnóstico por imagem , Adolescente , Fatores Etários , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Cirrose Hepática/diagnóstico por imagem , Masculino , Valor Preditivo dos Testes , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa