1.
Anal Chem ; 95(46): 17099-17107, 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37946366

RESUMO

High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS) is a versatile technique for the detection of gaseous target molecules that is particularly useful in complex chemical environments, while the instrumental effort is low. Operating HiKE-IMS at reduced pressures from 10 to 60 mbar results in fewer ion-neutral collisions than at ambient pressure, reducing chemical cross-sensitivities and eliminating the need for a preceding separation dimension, e.g., by gas chromatography. In addition, HiKE-IMS allows operation over a wide range of reduced electric field strengths E/N up to 120 Td, allowing separation of ions by low-field ion mobility and exploiting the field dependence of ion mobility, potentially allowing separation of ion species at high E/N despite similar low-field ion mobilities. Given these advantages, HiKE-IMS can be a useful tool for trace gas analysis such as triacetone triperoxide (TATP) detection. In this study, we employed HiKE-IMS to detect TATP. We explore the ionization of TATP and the field-dependent ion mobilities, providing a database of the ion mobilities depending on E/N. Confirming the literature results, ionization of TATP by proton transfer with H3O+ in HiKE-IMS generates fragments, but using NH4+ as the primary reactant ion leads to the TATP·NH4+ adduct. This adduct fragments at high E/N, which could provide additional information for reliable detection of TATP. Thus, operating HiKE-IMS at variable E/N in the drift region generates a unique fingerprint of TATP made of all ion species related to TATP and their ion mobilities depending on E/N, potentially reducing the rate of false positives.

2.
Sensors (Basel) ; 23(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36772114

RESUMO

This systematic review describes and discusses three commercially available integrated systems for forensic DNA analysis, i.e., ParaDNA, RapidHIT, and ANDE. A variety of aspects, such as performance, time-to-result, ease-of-use, portability, and costs (per analysis run) of these three (modified) rapid DNA analysis systems, are considered. Despite their advantages and developmental progress, major steps still have to be made before rapid systems can be broadly applied at crime scenes for full DNA profiling. Aspects in particular that need (further) improvement are portability, performance, the possibility to analyze a (wider) variety of (complex) forensic samples, and (cartridge) costs. Moreover, steps forward regarding ease-of-use and time-to-result will benefit the broader use of commercial rapid DNA systems. In fact, it would be a profit if rapid DNA systems could be used for full DNA profile generation as well as indicative analyses that can give direction to forensic investigators which will speed up investigations.


Assuntos
Genética Forense , Repetições de Microssatélites , Reação em Cadeia da Polimerase , Impressões Digitais de DNA , DNA/genética , DNA/análise
3.
Sensors (Basel) ; 23(13)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37448049

RESUMO

Already for some decades lateral flow assays (LFAs) are 'common use' devices in our daily life. Also, for forensic use LFAs are developed, such as for the analysis of illicit drugs and DNA, but also for the detection of explosives and body fluid identification. Despite their advantages, including ease-of-use, LFAs are not yet frequently applied at a crime scene. This review describes (academic) developments of LFAs for forensic applications, focusing on biological and chemical applications, whereby the main advantages and disadvantages of LFAs for the different forensic applications are summarized. Additionally, a critical review is provided, discussing why LFAs are not frequently applied within the forensic field and highlighting the steps that are needed to bring LFAs to the forensic market.


Assuntos
Líquidos Corporais , Drogas Ilícitas , Medicina Legal , Bioensaio , DNA
4.
Sensors (Basel) ; 23(11)2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37300031

RESUMO

Recently a hand-held, carbon-nanotube-based electronic nose became available on the market. Such an electronic nose could be interesting for applications in the food industry, health monitoring, environmental monitoring, and security services. However, not much is known about the performance of such an electronic nose. In a series of measurements, the instrument was exposed to low ppm vapor concentrations of four volatile organic compounds with different scent profiles and polarities. Detection limits, linearity of response, repeatability, reproducibility, and scent patterns were determined. The results indicate detection limits in the range of 0.1-0.5 ppm and a linear signal response in the range of 0.5-8.0 ppm. The repeatability of the scent patterns at compound concentrations of 2 ppm allowed the identification of the tested volatiles based on their scent pattern. However, the reproducibility was not sufficient, since different scent profiles were produced on different measurement days. In addition, it was noted that the response of the instrument diminished over time (over several months) possibly by sensor poisoning. The latter two aspects limit the use of the current instrument and make future improvements necessary.


Assuntos
Nanotubos de Carbono , Compostos Orgânicos Voláteis , Nariz Eletrônico , Feromônios , Odorantes , Monitoramento Ambiental
5.
Sensors (Basel) ; 23(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37631665

RESUMO

The decomposition of a body is influenced by burial conditions, making it crucial to understand the impact of different conditions for accurate grave detection. Geophysical techniques using drones have gained popularity in locating clandestine graves, offering non-invasive methods for detecting surface and subsurface irregularities. Ground-penetrating radar (GPR) is an effective technology for identifying potential grave locations without disturbance. This research aimed to prototype a drone system integrating GPR to assist in grave localization and to develop software for data management. Initial experiments compared GPR with other technologies, demonstrating its valuable applicability. It is suitable for various decomposition stages and soil types, although certain soil compositions have limitations. The research used the DJI M600 Pro drone and a drone-based GPR system enhanced by the real-time kinematic (RTK) global positioning system (GPS) for precision and autonomy. Tests with simulated graves and cadavers validated the system's performance, evaluating optimal altitude, speed, and obstacle avoidance techniques. Furthermore, global and local planning algorithms ensured efficient and obstacle-free flight paths. The results highlighted the potential of the drone-based GPR system in locating clandestine graves while minimizing disturbance, contributing to the development of effective tools for forensic investigations and crime scene analysis.


Assuntos
Radar , Dispositivos Aéreos não Tripulados , Algoritmos , Crime , Solo
6.
Forensic Sci Int ; 349: 111743, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37315480

RESUMO

Human scent has long been cited as a probable parameter that can be exploited as a biometric measure. Identifying the scent of individual persons using specially trained canines is a well-known forensic method which is frequently used in criminal investigations. To date there has been limited research on the chemical components present in human scent and their usefulness in distinguishing between people. This review delivers insight into studies which have dealt with human scent in forensics. Sample collection methods, sample preparation, instrumental analysis, compounds identified in human scent and data analysis techniques are discussed. Methods for sample collection and preparation are presented, but to date, there is no available validated method. Instrumental methods are presented and from the overview it is clear that gas chromatography combined with mass spectrometry is the method of choice. New developments such as two-dimensional gas chromatography offer exiting possibilities to collect more information. Given the amount and complexity of data, data processing is used to extract the relevant information to discriminate people. Finally, sensors offer new opportunities for the characterization of human scent.