Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 2024 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-39155401

RESUMO

PURPOSE: To develop a novel framework to improve the visualization of distal arteries in arterial spin labeling (ASL) dynamic MRA. METHODS: The attenuation of ASL blood signal due to the repetitive application of excitation RF pulses was minimized by splitting the acquisition volume into multiple thin 2D (M2D) slices, thereby reducing the exposure of the arterial blood magnetization to RF pulses while it flows within the brain. To improve the degraded vessel visualization in the slice direction due to the limited minimum achievable 2D slice thickness, a super-resolution (SR) convolutional neural network (CNN) was trained by using 3D time-of-flight (TOF)-MRA images from a large public dataset. And then, we applied domain transfer from 3D TOF-MRA to M2D ASL-MRA, while avoiding acquiring a large number of ASL-MRA data required for CNN training. RESULTS: Compared to the conventional 3D ASL-MRA, far more distal arteries were visualized with higher signal intensity by using M2D ASL-MRA. In general, however, the vessel visualization with a conventional interpolation was prone to be blurry and unclear due to the limited spatial resolution in the slice direction, particularly in small vessels. Application of CNN-based SR transferred from 3D TOF-MRA to M2D ASL-MRA successfully addressed such a limitation and achieved clearer visualization of small vessels than conventional interpolation. CONCLUSION: This study demonstrated that the proposed framework provides improved visualization of distal arteries in later dynamic phases, which will particularly benefit the application of this approach in patients with cerebrovascular disease who have slow blood flow.

2.
J Magn Reson Imaging ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662966

RESUMO

BACKGROUND: Standard Cartesian time-of-flight (TOF) head magnetic resonance angiography (MRA) is routinely used to evaluate the intracranial arteries, but does not provide quantitative hemodynamic information that is useful for patient risk stratification as well as for monitoring treatment and tracking changes in blood flow over time. Quantitative TOF (qTOF) MRA represents a new and efficient method for simultaneous evaluating the intracranial arteries and quantifying blood flow velocity, but it has not yet been evaluated in patients with cerebrovascular disease. PURPOSE: To evaluate qTOF for simultaneously evaluating the intracranial arteries and quantifying intracranial blood flow velocity in patients with cerebrovascular disease, without the need for a phase contrast (PC) scan. STUDY TYPE: Prospective. SUBJECTS: Twenty-four patients (18 female, 6 male) with cerebrovascular disease. FIELD STRENGTH/SEQUENCES: Head MRA at 3 T using gradient-echo 3D qTOF, standard Cartesian TOF, and PC protocols. ASSESSMENT: Three independent readers assessed arterial image quality using a 4-point scale (1: non-diagnostic, 4: excellent) and artifact presence. Total and component flow velocities obtained with qTOF and PC were measured. STATISTICAL TESTS: Wilcoxon signed-rank tests, Gwet's AC2, intraclass correlation coefficients (ICC) for absolute agreement, Bland-Altman analyses, tests of equal proportions. P values <0.05 were considered statistically significant. RESULTS: Averaged across readers and compared to standard Cartesian TOF, qTOF significantly improved overall arterial image quality (3.8 ± 0.2 vs. 3.6 ± 0.5), image quality at locations of pathology (3.7 ± 0.5 vs. 3.4 ± 0.7), and increased the proportion of evaluations rated without artifacts (63.9% [46/72] vs. 37.5% [27/72]). qTOF significantly agreed with PC for total flow velocity (ICC = 0.71) and component flow velocity (ICC = 0.89). DATA CONCLUSION: qTOF angiography of the head matched or improved upon the image quality of standard Cartesian TOF, reduced image artifacts, and provided quantitative hemodynamic data, without the need for a PC scan. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.

3.
J Cardiovasc Magn Reson ; 26(2): 101046, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810732

RESUMO

BACKGROUND: Three-dimensional (3D) contrast-enhanced magnetic resonance angiography (CEMRA) is routinely used for vascular evaluation. With existing techniques for CEMRA, diagnostic image quality is only obtained during the first pass of the contrast agent or shortly thereafter, whereas angiographic quality tends to be poor when imaging is delayed to the equilibrium phase. We hypothesized that prolonged blood pool contrast enhancement could be obtained by imaging with a balanced T1 relaxation-enhanced steady-state (bT1RESS) pulse sequence, which combines 3D balanced steady-state free precession (bSSFP) with a saturation recovery magnetization preparation to impart T1 weighting and suppress background tissues. An electrocardiographic-gated, two-dimensional-accelerated version with isotropic 1.1-mm spatial resolution was evaluated for breath-hold equilibrium phase CEMRA of the thoracic aorta and heart. METHODS: The study was approved by the institutional review board. Twenty-one subjects were imaged using unenhanced 3D bSSFP, time-resolved CEMRA, first-pass gated CEMRA, followed by early and late equilibrium phase gated CEMRA and bT1RESS. Nine additional subjects were imaged using equilibrium phase 3D bSSFP and bT1RESS. Images were evaluated for image quality, aortic root sharpness, and visualization of the coronary artery origins, as well as using standard quantitative measures. RESULTS: Equilibrium phase bT1RESS provided better image quality, aortic root sharpness, and coronary artery origin visualization than gated CEMRA (P < 0.05), and improved image quality and aortic root sharpness versus unenhanced 3D bSSFP (P < 0.05). It provided significantly larger apparent signal-to-noise and apparent contrast-to-noise ratio values than gated CEMRA and unenhanced 3D bSSFP (P < 0.05) and provided ninefold better fluid suppression than equilibrium phase 3D bSSFP. Aortic diameter and main pulmonary artery diameter measurements obtained with bT1RESS and first-pass gated CEMRA strongly correlated (P < 0.05). CONCLUSIONS: We found that using bT1RESS greatly prolongs the useful duration of blood pool contrast enhancement while improving angiographic image quality compared with standard CEMRA techniques. Although further study is needed, potential advantages for vascular imaging include eliminating the current requirement for first-pass imaging along with better reliability and accuracy for a wide range of cardiovascular applications.

5.
Clin Kidney J ; 17(6): sfae101, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38915436

RESUMO

Background: The aim of this work was to create and evaluate a preoperative non-contrast-enhanced (CE) magnetic resonance imaging (MRI)/angiography (MRA) protocol to assess renal function and visualize renal arteries and any abnormalities in potential living kidney donors. Methods: In total, 28 subjects were examined using scintigraphy to determine renal function. In addition, 3D-pseudocontinuous arterial spin labeling (pCASL), a 2D-non-CE electrocardiogram-triggered radial quiescent interval slice-selective (QISS-MRA), and 4D-CE time-resolved angiography with interleaved stochastic trajectories (CE-MRA) were performed to assess renal perfusion, visualize renal arteries and detect any abnormalities. Two glomerular filtration rates [described by Gates (GFRG) and according to the Chronic Kidney Disease Epidemiology Collaboration formula (GFRCKD-EPI)]. The renal volumes were determined using both MRA techniques. Results: The mean value of regional renal blood flow (rRBF) on the right side was significantly higher than that on the left. The agreements between QISS-MRA and CE-MRA concerning the assessment of absence or presence of an aberrant artery and renal arterial stenosis were perfect. The mean renal volumes measured in the right kidney with QISS-MRA were lower than the corresponding values of CE-MRA. In contrast, the mean renal volumes measured in the left kidney with both MRA techniques were similar. The correlation between the GFRG and rRBF was compared in the same manner as that between GFRCKD-EPI and rRBF. Conclusion: The combination of pCASL and QISS-MRA constitute a reliable preoperative protocol with a total measurement time of <10 min without the potential side effects of gadolinium-based contrast agents or radiation exposure.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa