Detalhe da pesquisa
1.
Evaluation of 12-lead electrocardiogram at 0.55T for improved cardiac monitoring in magnetic resonance imaging.
J Cardiovasc Magn Reson
; 26(1): 101009, 2024 Feb 10.
Artigo
Inglês
| MEDLINE | ID: mdl-38342406
2.
Interventional cardiovascular magnetic resonance: state-of-the-art.
J Cardiovasc Magn Reson
; 25(1): 48, 2023 08 14.
Artigo
Inglês
| MEDLINE | ID: mdl-37574552
3.
Intracardiac MR imaging (ICMRI) guiding-sheath with amplified expandable-tip imaging and MR-tracking for navigation and arrythmia ablation monitoring: Swine testing at 1.5 and 3T.
Magn Reson Med
; 87(6): 2885-2900, 2022 06.
Artigo
Inglês
| MEDLINE | ID: mdl-35142398
4.
Native contrast visualization and tissue characterization of myocardial radiofrequency ablation and acetic acid chemoablation lesions at 0.55 T.
J Cardiovasc Magn Reson
; 23(1): 50, 2021 05 06.
Artigo
Inglês
| MEDLINE | ID: mdl-33952312
5.
Acute enhancement of necrotic radio-frequency ablation lesions in left atrium and pulmonary vein ostia in swine model with non-contrast-enhanced T1 -weighted MRI.
Magn Reson Med
; 83(4): 1368-1379, 2020 04.
Artigo
Inglês
| MEDLINE | ID: mdl-31565818
6.
Segmented radial cardiac MRI during arrhythmia using retrospective electrocardiogram and respiratory gating.
Magn Reson Med
; 81(3): 1726-1738, 2019 03.
Artigo
Inglês
| MEDLINE | ID: mdl-30362588
7.
Non-contrast-enhanced T1 -weighted MRI of myocardial radiofrequency ablation lesions.
Magn Reson Med
; 79(2): 879-889, 2018 02.
Artigo
Inglês
| MEDLINE | ID: mdl-28497622
8.
Inflammatory reaction to TYRX antibacterial envelope mimicking infection.
J Cardiovasc Electrophysiol
; 34(8): 1755-1757, 2023 08.
Artigo
Inglês
| MEDLINE | ID: mdl-37350293
9.
Current management and clinical outcomes for catheter ablation of atrioventricular nodal re-entrant tachycardia.
Europace
; 20(4): e51-e59, 2018 04 01.
Artigo
Inglês
| MEDLINE | ID: mdl-28541507
10.
Initial validation of a novel ECGI system for localization of premature ventricular contractions and ventricular tachycardia in structurally normal and abnormal hearts.
J Electrocardiol
; 51(5): 801-808, 2018.
Artigo
Inglês
| MEDLINE | ID: mdl-30177316
11.
Balanced-force shim system for correcting magnetic-field inhomogeneities in the heart due to implanted cardioverter defibrillators.
Front Med (Lausanne)
; 11: 1225848, 2024.
Artigo
Inglês
| MEDLINE | ID: mdl-38414618
12.
MR-Safe Cartesian Platform for Active Cardiac Shimming: Preliminary Validation.
IEEE Trans Biomed Eng
; PP2024 Feb 05.
Artigo
Inglês
| MEDLINE | ID: mdl-38315598
13.
Phrenic nerve injury: An underrecognized and potentially preventable complication of pulmonary vein isolation using a wide-area circumferential ablation approach.
J Cardiovasc Electrophysiol
; 24(10): 1086-91, 2013 Oct.
Artigo
Inglês
| MEDLINE | ID: mdl-23869718
14.
Quality assessment of cardiac magnetic resonance myocardial scar imaging prior to ventricular arrhythmia ablation.
Int J Cardiovasc Imaging
; 39(2): 411-421, 2023 Feb.
Artigo
Inglês
| MEDLINE | ID: mdl-36331683
15.
Growth Differentiation Factor-15 Predicts Mortality and Heart Failure Exacerbation But Not Ventricular Arrhythmias in Patients With Cardiomyopathy.
J Am Heart Assoc
; 12(3): e8023, 2023 02 07.
Artigo
Inglês
| MEDLINE | ID: mdl-36718879
16.
EDEN (Electrocardiographic Radial Depth Navigation): A Novel Approach to Navigate Inside Heart Muscle.
JACC Clin Electrophysiol
; 9(8 Pt 3): 1741-1754, 2023 08.
Artigo
Inglês
| MEDLINE | ID: mdl-37354176
17.
The Association of Clustered Ventricular Arrhythmia and Cycle Length With Scar Burden in Cardiomyopathy.
JACC Clin Electrophysiol
; 8(8): 957-966, 2022 08.
Artigo
Inglês
| MEDLINE | ID: mdl-35981800
18.
Intra-cardiopulmonary resuscitation hypothermia with and without volume loading in an ischemic model of cardiac arrest.
Circulation
; 120(14): 1426-35, 2009 Oct 06.
Artigo
Inglês
| MEDLINE | ID: mdl-19770397
19.
Outcomes from low versus high-flow cardiopulmonary resuscitation in a swine model of cardiac arrest.
Am J Emerg Med
; 28(2): 195-202, 2010 Feb.
Artigo
Inglês
| MEDLINE | ID: mdl-20159390
20.
MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation.
IEEE Trans Biomed Eng
; 67(6): 1616-1627, 2020 06.
Artigo
Inglês
| MEDLINE | ID: mdl-31535979