Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Transplant ; 37(10): e15118, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37658824

RESUMO

Patients undergoing extracorporeal membrane oxygenation (ECMO) are susceptible to thrombosis, which is a major cause of death and morbidity. However, there is no objective ECMO thrombosis grading scale to standardize evaluation, guide treatment, and facilitate further research. In this letter, we propose an objective grading scale for ECMO circuit thrombosis based on physical characteristics and location within the circuit. This ECMO thrombosis scale will allow for protocolized escalation of ECMO thrombosis treatment, ranging from watchful observation, intensified anticoagulation, and circuit exchange.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Humanos , Trombose/diagnóstico , Trombose/etiologia , Coagulação Sanguínea , Anticoagulantes
2.
J Cardiovasc Dev Dis ; 10(4)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37103027

RESUMO

The current standard of care for pediatric patients with unrepairable congenital valvular disease is a heart valve implant. However, current heart valve implants are unable to accommodate the somatic growth of the recipient, preventing long-term clinical success in these patients. Therefore, there is an urgent need for a growing heart valve implant for children. This article reviews recent studies investigating tissue-engineered heart valves and partial heart transplantation as potential growing heart valve implants in large animal and clinical translational research. In vitro and in situ designs of tissue engineered heart valves are discussed, as well as the barriers to clinical translation.

3.
Innovations (Phila) ; 18(2): 126-131, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36872577

RESUMO

Many young adults require heart valve replacements. Current options for valve replacement in adults include mechanical valves, bioprosthetic valves, or the Ross procedure. Of these, mechanical and bioprosthetic valves are the most common options, although mechanical valve usage predominates in younger adults due to durability, while bioprosthetic valve usage predominates in older adults. Partial heart transplantation is a new method of valvular replacement that can deliver durable and self-repairing valves and allow adult patients freedom from anticoagulation therapy. This procedure involves transplantation of donor heart valves only, permitting expanded utilization of donor hearts as compared with orthotopic heart transplantation. In this review, we discuss the potential benefits of this procedure in adults who elect against the anticoagulation regimen required of mechanical valve replacements, although it has not yet been clinically established. Partial heart transplantation is a promising new therapy for the treatment of pediatric valvular dysfunction. This is a novel technique in the adult population with potential utility for valve replacement in young patients for whom anticoagulation therapy is problematic, such as women who wish to become pregnant, patients with bleeding disorders, and patients with active lifestyles.


Assuntos
Bioprótese , Procedimentos Cirúrgicos Cardíacos , Transplante de Coração , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Gravidez , Adulto Jovem , Humanos , Feminino , Criança , Idoso , Doenças das Valvas Cardíacas/cirurgia , Doadores de Tecidos , Anticoagulantes
4.
J Cardiovasc Dev Dis ; 10(6)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37367399

RESUMO

Unrepairable congenital heart valve disease is an unsolved problem in pediatric cardiac surgery because there are no growing heart valve implants. Partial heart transplantation is a new type of transplant that aims to solve this problem. In order to study the unique transplant biology of partial heart transplantation, animal models are necessary. This study aimed to assess the morbidity and mortality of heterotopic partial heart transplantation in rodent models. This study assessed two models. The first model involved transplanting heart valves from donor animals into the abdominal aortic position in the recipient animals. The second model involved transplanting heart valve leaflets into the renal subcapsular position of the recipient animals. A total of 33 animals underwent heterotopic partial heart transplantation in the abdominal aortic position. The results of this model found a 60.61% (n = 20/33) intraoperative mortality rate and a 39.39% (n = 13/33) perioperative mortality rate. Intraoperative mortality was due to vascular complications from the procedure, and perioperative mortality was due to graft thrombosis. A total of 33 animals underwent heterotopic partial heart transplantation in the renal subcapsular position. The results of this model found a 3.03% (n = 1/33) intraoperative mortality rate, and the remaining 96.97% survived (n = 32/33). We conclude that the renal subcapsular model has a lower mortality rate and is technically more accessible than the abdominal aortic model. While the heterotopic transplantation of valves into the abdominal aortic position had significant morbidity and mortality in the rodent model, the renal subcapsular model provided evidence for successful heterotopic transplantation.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa