RESUMO
INTRODUCTION: High-frequency low-tidal-volume (HFLTV) ventilation during radiofrequency catheter ablation (RFCA) for paroxysmal atrial fibrillation (PAF) has been shown to be superior to standard ventilation (SV) in terms of procedural efficiency, acute and long-term clinical outcomes. Our study aimed to compare ablation lesions characteristics utilizing HFLTV ventilation versus SV during RFCA of PAF. METHODS: A retrospective analysis was conducted on patients who underwent pulmonary vein isolation (PVI) for PAF between August 2022 and March 2023, using high-power short-duration ablation. Thirty-five patients underwent RFCA with HFLTV ventilation and were matched with another cohort of 35 patients who underwent RFCA with SV. Parameters including ablation duration, contact force (CF), impedance drop, and ablation index were extracted from the CARTONET database for each ablation lesion. RESULTS: A total of 70 patients were included (HFLTV = 35/2484 lesions, SV = 35/2830 lesions) in the analysis. There were no differences in baseline characteristics between the groups. While targeting the same ablation index, the HFLTV ventilation group demonstrated shorter average ablation duration per lesion (12.3 ± 5.0 vs. 15.4 ± 8.4 s, p < .001), higher average CF (17.0 ± 8.5 vs. 10.5 ± 4.6 g, p < .001), and greater impedance reduction (9.5 ± 4.6 vs. 7.7 ± 4.1 ohms, p < .001). HFLTV ventilation group also demonstrated shorter total procedural time (61.3 ± 25.5 vs. 90.8 ± 22.8 min, p < .001), ablation time (40.5 ± 18.6 vs. 65.8 ± 22.5 min, p < .001), and RF time (15.3 ± 4.8 vs. 22.9 ± 9.7 min, p < .001). CONCLUSION: HFLTV ventilation during PVI for PAF was associated with improved ablation lesion parameters and procedural efficiency compared to SV.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Feminino , Masculino , Ablação por Cateter/efeitos adversos , Estudos Retrospectivos , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Potenciais de Ação , Bases de Dados FactuaisRESUMO
INTRODUCTION: Training in clinical cardiac electrophysiology (CCEP) involves the development of catheter handling skills to safely deliver effective treatment. Objective data from analysis of ablation data for evaluating trainee of CCEP procedures has not previously been possible. Using the artificial intelligence cloud-based system (CARTONET), we assessed the impact of trainee progress through ablation procedural quality. METHODS: Lesion- and procedure-level data from all de novo atrial fibrillation (AF) and cavotricuspid isthmus (CTI) ablations involving first-year (Y1) or second-year (Y2) fellows across a full year of fellowship was curated within Cartonet. Lesions were automatically assigned to anatomic locations. RESULTS: Lesion characteristics, including contact force, catheter stability, impedance drop, ablation index value, and interlesion time/distance were similar over each training year. Anatomic location and supervising operator significantly affected catheter stability. The proportion of lesion sets delivered independently and of lesions delivered by the trainee increased steadily from the first quartile of Y1 to the last quartile of Y2. Trainee perception of difficult regions did not correspond to objective measures. CONCLUSION: Objective ablation data from Cartonet showed that the progression of trainees through CCEP training does not impact lesion-level measures of treatment efficacy (i.e., catheter stability, impedance drop). Data demonstrates increasing independence over a training fellowship. Analyses like these could be useful to inform individualized training programs and to track trainee's progress. It may also be a useful quality assurance tool for ensuring ongoing consistency of treatment delivered within training institutions.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Competência Clínica , Educação de Pós-Graduação em Medicina , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Curva de Aprendizado , Técnicas Eletrofisiológicas Cardíacas , Inteligência Artificial , Fatores de Tempo , Resultado do Tratamento , Bolsas de Estudo , Cardiologistas/educação , Eletrofisiologia Cardíaca/educação , Cateteres CardíacosRESUMO
BACKGROUND: Hemodialysis patients have high rates of sudden death, but relationships between serum electrolytes, the dialysis prescription, and intra-dialytic shifts in fluid and electrolyte with arrhythmia are uncertain. METHODS: We analyzed sixty-six hemodialysis patients who underwent loop recorder implantation with continuous electrocardiographic monitoring, weekly to bi-weekly testing of pre- and post-dialysis electrolytes, and detailed capture of dialysis prescription and flow sheet data for 6 months. The incidence rate ratio (IRR) of reviewer confirmed arrhythmias (RCA) during dialysis through 8 h after dialysis and associations with serum chemistries and dialytic parameters were assessed using adjusted, negative-binomial regression. RESULTS: Among 66 individuals with a mean age of 56 years, 12,480 events were detected in 64 (97%) patients. RCA nadired 12-24 h after dialysis and increased during the final 12 h of the inter-dialytic interval through the first 8 h after dialysis. Higher pre-dialysis serum magnesium concentration was associated with lower incidence rate ratio for arrythmia (IRR per 1 mg/dL increase 0.49, 95% CI; 0.25, 0.94), as was dialysate calcium concentration > 2.5 mEq/L vs. 2.5 mEq/L (IRR 0.52, 95% CI: 0.39, 0.70). Neither intradialytic serum potassium nor weight change were significantly associated with RCA rate. However, there was effect modification such that arrhythmia rate was maximal with concurrently high intradialytic volume and potassium removal (Pinteraction = 0.01). CONCLUSIONS: Intra and post-dialytic arrhythmias are common in hemodialysis. Additional studies designed to further elucidate whether modification of the serum magnesium concentration, dialysate calcium concentration, and the extent of intradialytic potassium and fluid removal reduces the risk of per-dialytic arrhythmia are warranted. TRIAL REGISTRATION: Clinicaltrials.gov NCT01779856. Prospectively registered on January 22, 2013.
Assuntos
Arritmias Cardíacas/fisiopatologia , Eletrocardiografia Ambulatorial/métodos , Falência Renal Crônica/fisiopatologia , Falência Renal Crônica/terapia , Diálise Renal/métodos , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevenção & controle , Feminino , Seguimentos , Soluções para Hemodiálise/administração & dosagem , Humanos , Falência Renal Crônica/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Diálise Renal/efeitos adversosRESUMO
Sudden death is one of the more frequent causes of death for hemodialysis patients, but the underlying mechanisms, contribution of arrhythmia, and associations with serum chemistries or the dialysis procedure are incompletely understood. To study this, implantable loop recorders were utilized for continuous cardiac rhythm monitoring to detect clinically significant arrhythmias including sustained ventricular tachycardia, bradycardia, asystole, or symptomatic arrhythmias in hemodialysis patients over six months. Serum chemistries were tested pre- and post-dialysis at least weekly. Dialysis procedure data were collected at every session. Associations with clinically significant arrhythmias were assessed using negative binomial regression modeling. Sixty-six patients were implanted and 1678 events were recorded in 44 patients. The majority were bradycardias (1461), with 14 episodes of asystole and only one of sustained ventricular tachycardia. Atrial fibrillation, although not defined as clinically significant arrhythmias, was detected in 41% of patients. With thrice-weekly dialysis, the rate was highest during the first dialysis session of the week and was increased during the last 12 hours of each inter-dialytic interval, particularly the long interval. Among serum and dialytic parameters, only higher pre-dialysis serum sodium and dialysate calcium over 2.5 mEq/L were independently associated with clinically significant arrhythmias. Thus, clinically significant arrhythmias are common in hemodialysis patients, and bradycardia and asystole rather than ventricular tachycardia may be key causes of sudden death in hemodialysis patients. Associations with the temporal pattern of dialysis suggest that modification of current dialysis practices could reduce the incidence of sudden death.
Assuntos
Arritmias Cardíacas/epidemiologia , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Biomarcadores/sangue , Cálcio/metabolismo , Morte Súbita Cardíaca/epidemiologia , Soluções para Diálise/metabolismo , Feminino , Frequência Cardíaca , Humanos , Incidência , Índia/epidemiologia , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/mortalidade , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Diálise Renal/mortalidade , Medição de Risco , Fatores de Risco , Sódio/sangue , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
INTRODUCTION: Atrial fibrillation (AF) ablation is increasingly common, but is associated with potential major complications. Technology, experience, and protocols have evolved significantly in recent times, and may have impacted procedural safety. We sought to compare AF ablation safety profiles, including complication rates and fluoroscopy times in a "modern" versus "historical" cohort. METHODS AND RESULTS: We evaluated consecutive patients undergoing AF ablation from a modern cohort (MC) from 2014 to 2015 and a historic cohort (HC) from 2009 to 2011 for complications. Major complications were categorized according to Heart Rhythm Society guidelines. We included 1,425 patients, 726 in the HC and 699 in the MC. The MC was older, had more OSA and less valvular AF. Fifty-two (3.5%) procedures suffered major complications across the cohorts, with significantly fewer in the MC (5.0% vs. 2.3%, P = 0.007). The largest reductions were seen in vascular, hemorrhagic, ischemic stroke, and perforation/tamponade related complications. Periprocedural antiplatelets drugs (aHR 2.1 [95 CI 1.1-3.9], P = 0.02) and force-sensing catheters (aHR 0.4 [95 CI 0.2-0.9], P = 0.03) were independently related to major complication rates. Direct oral anticoagulants and uninterrupted anticoagulation were not associated with complications. There was a decrease in both fluoroscopy (-17.4 minutes [95 CI 19.2-15.6], P < 0.0001) and radiofrequency ablation times (-561 seconds [95CI -750 to -371], P < 0.0001). CONCLUSIONS: The safety profile of AF ablation has improved significantly in less than a decade.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/tendências , Complicações Pós-Operatórias/prevenção & controle , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Radiografia Intervencionista/tendências , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Aims: A commonly held notion is that patients with a family history of atrial fibrillation (AF) have worse atrial substrate and higher rates of arrhythmia recurrence following ablation. We sought to examine differences in atrial substrate and catheter ablation outcomes in patients with a 1st degree family member with paroxysmal or persistent AF (PeAF) compared to those without. Methods and results: A total of 256 consecutive patients undergoing their 1st ablation for AF (123 paroxysmal, 133 persistent) with >1 year follow up were included. The presence of one 1st-degree family relative was defined as a 'positive family history'. Clinical characteristics, electroanatomic map findings, ablation characteristics and outcomes were compared in patients with and without a positive family history of AF. Patients with paroxysmal fibrillation with a positive family history (n = 57; 46%) had similar clinical characteristics and arrhythmia recurrence after catheter ablation as those without. Of those that recurred, patients with a positive family history were more likely to have progressed to PeAF (P = 0.05). Patients with PeAF with a positive family history (n = 75; 56%) had similar clinical characteristics, electroanatomic mapping findings and ablation characteristics, but worse long term arrhythmia free survival (P = 0.04). Conclusion: The presence of a 1st-degree family member with AF does not impact the clinical outcomes of catheter ablation for paroxysmal AF. However, a positive family history is associated with worse arrhythmia free survival in patients with PeAF. This finding is not explained by differences in clinical characteristics, atrial substrate assessed by voltage maps or ablation characteristics.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Átrios do Coração/fisiopatologia , Anamnese/métodos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Mapeamento Epicárdico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Prognóstico , Intervalo Livre de Progressão , Recidiva , Estudos Retrospectivos , Fatores de Risco , Estados UnidosRESUMO
AIMS: Catheter ablation can be lifesaving in ventricular tachycardia (VT) storm, but the underlying substrate in patients with storm is not well characterized. We sought to compare the clinical factors, substrate, and outcomes differences in patients with sustained monomorphic VT who present for catheter ablation with VT storm versus those with a nonstorm presentation. METHODS: Consecutive ischemic (ICM; n = 554) or nonischemic cardiomyopathy patients (NICM; n = 369) with a storm versus nonstorm presentation were studied (ICM storm 186; NICM storm 101). RESULTS: In ICM, storm compared with nonstorm patients had significantly lower left ventricular (LV) ejection fraction (EF), greater number of antiarrhythmic drug (AAD) failures, slower VTs, greater number of scarred LV segments, higher incidence of anterior, septal, and apical endocardial LV scar (all P < 0.05). However, outcomes in follow-up were similar (12-month ventricular arrhythmia [VA]-free survival: 51% vs. 52%, P = 0.6; survival free of death/transplant 75% vs. 87%, P = 0.7). In addition to the above differences, NICM storm patients were also older; however, the extent and distribution of scar was similar except for a higher incidence of lateral endocardial scar in storm patients (P = 0.05). VA-free survival (36% vs. 47%, P = 0.004) and survival free of death/transplant, however, were worse in NICM storm than nonstorm patients (72% vs. 88%, P = 0.001). NICM storm patients had worse VA-free survival than ICM storm patients. CONCLUSION: There are differences in clinical factors and scar patterns in patients undergoing VT ablation who present with VT storm versus those with a nonstorm presentation. Clinical outcomes are worse in NICM storm patients.
Assuntos
Cardiomiopatias/complicações , Ablação por Cateter , Isquemia Miocárdica/complicações , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Adulto , Idoso , Antiarrítmicos/uso terapêutico , Boston , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Cicatriz/etiologia , Cicatriz/fisiopatologia , Progressão da Doença , Intervalo Livre de Doença , Feminino , Frequência Cardíaca , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/fisiopatologia , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
BACKGROUND: Patients on rivaroxaban have variable international normalized ratios (INRs) but it is uncertain if INR impacts procedural heparin requirement during left atrial ablation. We sought to examine the determinants of heparin dosing in this patient population. METHODS: We reviewed consecutive patients who received rivaroxaban within 24 hours of left atrial ablation and compared them to patients on uninterrupted warfarin. The determinants of heparin requirement were evaluated using regression analysis. We then tested a weight-based heparin dose prospectively in rivaroxaban patients. RESULTS: There were 258 patients on rivaroxaban and 213 on warfarin. The mean INR was 1.4 in the rivaroxaban group and 2.3 in the warfarin group (P < 0.01). To achieve an activated clotting time (ACT) >350 seconds, rivaroxaban patients required significantly more heparin (166.9 vs. 78.3 units/kg, P < 0.001). In the rivaroxaban group, body weight was the strongest predictor of heparin dose (r = 0.52), while INR was weakly correlated (r = -0.21). In the prospective group, 25 patients were given an initial heparin dose of 120 units/kg with 22/25 (88%) achieving an ACT > 300 seconds. There were seven and three cases of pericardial effusion in rivaroxaban and warfarin patients, respectively (P = 0.41). The average volume drained in the rivaroxaban group was elevated (988.6 vs. 275.0 mL, P = 0.21). CONCLUSIONS: Body weight is the strongest predictor of procedural heparin requirement during left atrial ablation in patients on uninterrupted rivaroxaban, even in those with an elevated INR. A heparin dose of 120 units/kg achieves an ACT > 300 seconds in the majority of patients. In cases of pericardial effusion, bleeding may be prolonged.
Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Heparina/administração & dosagem , Rivaroxabana/administração & dosagem , Tromboembolia/epidemiologia , Tromboembolia/prevenção & controle , Administração Oral , Anticoagulantes/administração & dosagem , Peso Corporal , Relação Dose-Resposta a Droga , Quimioterapia Combinada/estatística & dados numéricos , Feminino , Fibrinolíticos/administração & dosagem , Fibrinolíticos/efeitos adversos , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Pré-Medicação/estatística & dados numéricos , Prevalência , Fatores de Risco , Rivaroxabana/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
BACKGROUND: Entrainment criteria for macroreentrant arrhythmias are based on detecting fusion between tachycardia and paced wavefronts, but this is often difficult for atrial tachycardias (AT) after ablation of atrial fibrillation. METHODS AND RESULTS: With the use of a multipolar catheter, pacing was performed from electrodes within the coronary sinus showing activation later than adjacent electrodes (downstream overdrive pacing) during 66 ATs in 62 patients: 20 cavotricuspid isthmus-dependent ATs, 20 perimitral ATs, 13 focal ATs with sequential coronary sinus activation, and 13 other macroreentrant left atrial ATs. The paced cycle length was 10 to 30 milliseconds below the tachycardia cycle length (TCL), and activation at the neighboring upstream electrodes was assessed. Downstream overdrive pacing at 48 sites close to a macroreentrant circuit (PPI-TCL <40 milliseconds, where PPI is postpacing interval) produced constant fusion demonstrated by a long stimulus to upstream atrial electrogram interval (S-Au) >75% TCL and was consistent with orthodromic activation of the upstream site despite its close proximity to the pacing site. In contrast, downstream overdrive pacing at 18 sites during focal AT or remote from the macroreentrant AT circuit (PPI-TCL >40 milliseconds) always demonstrated a comparatively short S-Au <25% of TCL (12±4% versus 89±4% of TCL; P<0.001), consistent with direct activation. CONCLUSIONS: Selection of a downstream activation site for overdrive pacing can facilitate rapid recognition of macroreentry and proximity to the reentry circuit using a single multielectrode catheter by recognizing a PPI-TCL <40 milliseconds and S-Au >75% of TCL. Recognition of intracardiac constant fusion with this method is a novel criterion for transient entrainment.
Assuntos
Estimulação Cardíaca Artificial/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/terapia , Idoso , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Flutter Atrial/terapia , Ablação por Cateter , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Atrial Ectópica/cirurgiaRESUMO
AIMS: In patients presenting with spontaneous sustained ventricular tachycardia (VT) from the outflow-tract region without overt structural heart disease ablation may target premature ventricular contractions (PVCs) when VT is not inducible. We aimed to determine whether inducibility of VT affects ablation outcome. METHODS AND RESULTS: Data from 54 patients (31 men; age, 52 ± 13 years) without overt structural heart disease who underwent catheter ablation for symptomatic sustained VT originating from the right- or left-ventricular outflow region, including the great vessels. A single morphology of sustained VT was inducible in 18 (33%, SM group) patients, and 11 (20%) had multiple VT morphologies (MM group). VT was not inducible in 25 (46%) patients (VTni group). After ablation, VT was inducible in none of the SM group and in two (17%) patients in the MM group. In the VTni group, ablation targeted PVCs and 12 (48%) patients had some remaining PVCs after ablation. During follow-up (21 ± 19 months), VT recurred in 46% of VTni group, 40% of MM inducible group, and 6% of the SM inducible group (P = 0.004). Analysis of PVC morphology in the VTi group further supported the limitations of targeting PVCs in this population. CONCLUSION: Absence of inducible VT and multiple VT morphologies are not uncommon in patients with documented sustained outflow-tract VT without overt structural heart disease. Inducible VT is associated with better outcomes, suggesting that attempts to induce VT to guide ablation are important in this population.
Assuntos
Ablação por Cateter/normas , Eletrocardiografia/classificação , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Recidiva , Resultado do TratamentoRESUMO
BACKGROUND: To exposure in patients undergoing cardiac electrophysiology (EP) ablation. This included the use of a "very low" dose protocol, and the impact of angulations and patient body mass index (BMI) on radiation dose as a mean to reduce exposure. METHODS: A total of 212 retrospective patient data sets were collected during EP ablation procedures on a biplane fluoroscopy system. Dose metrics were computed based on dose-area product (DAP) measured by the system for each x-ray acquisition. RESULTS: Dose baselines of different ablation procedures were established as DAP and DAP per hour, with respect to patient BMI. The use of a "very low dose" protocol reduced exposure by 62% while providing adequate image quality. With approximate left anterior oblique (LAO) 50° and right anterior oblique (RAO) 30°, DAP and DAP rate were significantly higher in LAO compared to RAO (11.2 [4.8-25.3] Gy · cm(2) vs 5.28 [2.9-11.1] Gy · cm(2) and 74.0 [38.2-136.1] Gy · cm(2)/h vs 25.0 [16.4-44.1] Gy · cm(2)/h, respectively; P < 0.001). DAP and DAP rate were also significantly higher in patients with BMI > 30 vs BMI ≤ 30 (34.2 [22.3-58.7] Gy · cm(2) vs 12.4 [6.0-26.9] Gy · cm(2) and 84.9 [68.1-120.4] Gy · cm(2)/h vs 34.2 [21.7-52.9] Gy · cm(2)/h, respectively; P < 0.001). CONCLUSION: Protocol setting, system angulation, and BMI, in particular, wider angulation in LAO compared to RAO plane, exposes patients to significant higher radiation doses. Obese patients in standard LAO plane receive six times the radiation dose of nonobese patients in RAO.
Assuntos
Ablação por Cateter , Fluoroscopia , Doses de Radiação , Índice de Massa Corporal , Feminino , Humanos , Laboratórios Hospitalares , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de TempoRESUMO
Background: Sudden death accounts for approximately 25% of deaths among maintenance hemodialysis patients, occurring more frequently on hemodialysis days. Higher dialysate bicarbonate (DBIC) may predispose to alkalemia and arrhythmogenesis. Methods: We conducted a 12-month analysis of session-level data from 66 patients with implantable loop recorders. We fit logistic regression and negative binomial mixed-effects regression models to assess the association of DBIC with clinically significant arrhythmia (ventricular tachycardia ≥115 beats per minute [BPM] for at least 30 seconds, bradycardia ≤40 BPM for at least 6 seconds, or asystole for at least 3 seconds) and reviewer confirmed arrhythmia (RCAimplantable loop recorder-identified or patient-marked event for which a manual review of the stored electrocardiogram tracing confirmed the presence of atrial fibrillation, supraventricular tachycardia, sinus tachycardia with rate >130 BPM, ventricular tachycardia, asystole, or bradycardia). Models adjusted for age, sex, race, hemodialysis vintage, vascular access, and prehemodialysis serum bicarbonate and additionally for serum and dialysate potassium levels. Results: The mean age was 56±12 years, 70% were male, 53% were Black, and 35% were Asian. Fewer RCA episodes were associated with DBIC >35 than 35 mEq/L (incidence rate ratio 0.45 [0.27 to 0.75] and adjusted incident rate ratio 0.54 [0.30 to 0.97]), but the association was not significant when adjusting for serum and dialysate potassium levels (adjusted incident rate ratio, 0.60 [0.32 to 1.11]). Otherwise, no associations between DBIC and arrhythmia were identified. Conclusions: We observed a lower frequency of RCA with higher DBIC, compared with DBIC of 35 mEql/L, contrary to our original hypothesis, but this association was attenuated in fully adjusted models. Validation of these findings in larger studies is required, with a further need for interventional studies to explore the optimal DBIC concentration.
RESUMO
BACKGROUND: Sudden death accounts for â¼25% of deaths among maintenance hemodialysis (HD) patients, occurring more frequently on HD days. Higher dialysate bicarbonate (DBIC) may predispose to alkalemia and arrhythmogenesis. METHODS: We conducted a 12-month analysis of session-level data from 66 patients with implantable loop recorders. We fit logistic regression and negative binomial mixed effects regression models to assess the association of DBIC with clinically significant arrhythmia (CSA - ventricular tachycardia ≥115 beats per minute (BPM) for at least 30 seconds, bradycardia ≤40 BPM for at least 6 seconds, or asystole for at least 3 seconds) and reviewer confirmed arrhythmia (RCA - implantable-loop-recorder-identified or patient-marked event for which a manual review of the stored ECG tracing confirmed the presence of atrial fibrillation, supraventricular tachycardia, sinus tachycardia with rate >130 BPM, ventricular tachycardia, asystole, or bradycardia). Models adjusted for age, sex, race, HD vintage, vascular access, and pre-HD serum bicarbonate and additionally for serum and dialysate potassium levels. RESULTS: Mean age was 56 ± 12 years, 70% were male, 53% were Black, and 35% were Asian. Fewer RCA episodes were associated with DBIC >35 than 35 mEq/L (incidence rate ratio [IRR] 0.45 (0.27, 0.75) and aIRR 0.54 (0.30, 0.97)), but the association was not significant when adjusting for serum and dialysate potassium levels (aIRR 0.60 (0.32, 1.11)). Otherwise, no associations between DBIC and arrhythmia were identified. CONCLUSIONS: We observed a lower frequency of RCA with higher DBIC, compared with DBIC of 35 mEql/L, contrary to our original hypothesis, but this association was attenuated in fully adjusted models. Validation of these findings in larger studies is required, with a further need for interventional studies to explore the optimal DBIC concentration.
RESUMO
Rationale & Objective: The incidence of arrhythmia varies by time of day. How this affects individuals on maintenance dialysis is uncertain. Our objective was to quantify the relationship of arrhythmia with the time of day and timing of dialysis. Study Design: Secondary analysis of the Monitoring in Dialysis study, a multicenter prospective cohort study. Settings & Participants: Loop recorders were implanted for continuous cardiac monitoring in 66 participants on maintenance dialysis with a follow up of 6 months. Exposure: Time of day based on 6-hour intervals. Outcomes: Event rates of clinically significant arrhythmia. Analytical Approach: Negative binomial mixed effects regression models for repeated measures were used to evaluate data from the Monitoring in Dialysis study for differences in diurnal patterns of clinically significant arrhythmia among those with end-stage kidney disease with heart failure and end-stage kidney disease alone. We additionally analyzed rates according to presence of heart failure, time of dialysis shift, and dialysis versus nondialysis day. Results: Rates of clinically significant arrhythmia peaked between 12:00 AM and 5:59 AM and were more than 1.5-fold as frequent during this interval than the rest of the day. In contrast, variations in atrial fibrillation peaked between 6:00 AM and 11:59 AM, but variations across the day were qualitatively small. Clinically significant arrhythmia occurred at numerically higher rate in individuals with end-stage kidney disease and heart failure (5.9 events/mo; 95% CI, 1.3-26.8) than those without heart failure (4.0 events/mo; 95% CI, 0.9-17.9). Although differences in overall rate were not significant, their periodicity was significantly different (P < 0.001), with a peak between 12:00 AM and 6:00 AM with kidney failure alone and between 6:00 AM and 11:59 AM in those with heart failure. Although the overall clinically significant arrhythmia rate was similar in morning compared with evening dialysis shifts (P = 0.43), their periodicity differed with a peak between 12:00 AM and 5:59 AM in those with AM dialysis and a later peak between 6:00 AM and 11:59 AM in those with PM shifts. Limitations: Post hoc analysis, unable to account for unmeasured confounders. Conclusion: Clinically significant arrhythmias showed strong diurnal patterns with a maximal peak between 12:00 AM and 5:59 AM and noon. Although overall arrhythmia rates were similar, the peak rate occurred overnight in individuals without heart failure and during the morning in individuals with heart failure. Further exploration of the influence of circadian rhythm on arrhythmia in the setting of hemodialysis is needed.
Arrhythmias occur with a high frequency in individuals with kidney failure. We sought to understand whether there were diurnal patterns for common types of arrhythmias in individuals with kidney failure. We used continuous rhythm data from 66 individuals on dialysis with implantable loop recorders. We found that clinically significant arrhythmias including bradycardia primarily occur overnight and in the early morning, whereas atrial fibrillation is more evenly distributed during the day.
RESUMO
BACKGROUND: Left bundle branch area pacing (LBBAP) has emerged as a physiological alternative pacing strategy to biventricular pacing (BIVP) in cardiac resynchronization therapy (CRT). We aimed to assess the impact of LBBAP vs. BIVP on all-cause mortality and heart failure (HF)-related hospitalization in patients undergoing CRT. METHODS: Studies comparing LBBAP and BIVP for CRT in patients with HF with reduced left ventricular ejection fraction (LVEF) were included. The coprimary outcomes were all-cause mortality and HF-related hospitalization. Secondary outcomes included procedural and fluoroscopy time, change in QRS duration, and change in LVEF. RESULTS: Thirteen studies (12 observational and 1 RCT, n = 3239; LBBAP = 1338 and BIVP = 1901) with a mean follow-up duration of 25.8 months were included. Compared to BIVP, LBBAP was associated with a significant absolute risk reduction of 3.2% in all-cause mortality (9.3% vs 12.5%, RR 0.7, 95% CI 0.57-0.86, p < 0.001) and an 8.2% reduction in HF-related hospitalization (11.3% vs 19.5%, RR 0.6, 95% CI 0.5-0.71, p < 0.00001). LBBAP also resulted in reductions in procedural time (mean weighted difference- 23.2 min, 95% CI - 42.9 to - 3.6, p = 0.02) and fluoroscopy time (- 8.6 min, 95% CI - 12.5 to - 4.7, p < 0.001) as well as a significant reduction in QRS duration (mean weighted difference:- 25.3 ms, 95% CI - 30.9 to - 19.8, p < 0.00001) and a greater improvement in LVEF of 5.1% (95% CI 4.4-5.8, p < 0.001) compared to BIVP in the studies that reported these outcomes. CONCLUSION: In this meta-analysis, LBBAP was associated with a significant reduction in all-cause mortality as well as HF-related hospitalization when compared to BIVP. Additional data from large RCTs is warranted to corroborate these promising findings.
Assuntos
Terapia de Ressincronização Cardíaca , Causas de Morte , Insuficiência Cardíaca , Humanos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/mortalidade , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Hospitalização/estatística & dados numéricos , Medição de Risco , Volume Sistólico/fisiologia , Taxa de Sobrevida , Resultado do TratamentoRESUMO
BACKGROUND: Left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) are considered to be acceptable as LBBAP strategies. Differences in clinical outcomes between LBBP and LVSP are yet to be determined. OBJECTIVES: The purpose of this study was to compare the outcomes of LBBP vs LVSP vs BIVP for CRT. METHODS: In this prospective multicenter observational study, LBBP was compared with LVSP and BIVP in patients undergoing CRT. The primary composite outcome was freedom from heart failure (HF)-related hospitalization and all-cause mortality. Secondary outcomes included individual components of the primary outcome, postprocedural NYHA functional class, and electrocardiographic and echocardiographic parameters. RESULTS: A total of 415 patients were included (LBBP: n = 141; LVSP: n = 31; BIVP: n = 243), with a median follow-up of 399 days (Q1-Q3: 249.5-554.8 days). Freedom from the primary composite outcomes was 76.6% in the LBBP group and 48.4% in the LVSP group (HR: 1.37; 95% CI: 1.143-1.649; P = 0.001), driven by a 31.4% absolute increase in freedom from HF-related hospitalizations (83% vs 51.6%; HR: 3.55; 95% CI: 1.856-6.791; P < 0.001) without differences in all-cause mortality. LBBP was also associated with a higher freedom from the primary composite outcome compared with BIVP (HR: 1.43; 95% CI: 1.175-1.730; P < 0.001), with no difference between LVSP and BIVP. CONCLUSIONS: In patients undergoing CRT, LBBP was associated with improved outcomes compared with LVSP and BIVP, while outcomes between BIVP and LVSP are similar.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Prospectivos , Sistema de Condução Cardíaco , Ventrículos do Coração , EletrocardiografiaRESUMO
BACKGROUND: Women respond more favorably to biventricular pacing (BIVP) than men. Sex differences in atrioventricular and interventricular conduction have been described in BIVP studies. Left bundle branch area pacing (LBBAP) offers advantages due to direct capture of the conduction system. We hypothesized that men could respond better to LBBAP than BIVP. OBJECTIVES: This study aims to describe the sex differences in response to LBBAP vs BIVP as the initial cardiac resynchronization therapy (CRT). METHODS: In this multicenter prospective registry, we included patients with left ventricular ejection fraction ≤35% and left bundle branch block or a left ventricular ejection fraction ≤40% with an expected right ventricular pacing exceeding 40% undergoing initial CRT with LBBAP or BIVP. The composite primary outcome was heart failure-related hospitalization and all-cause mortality. The primary safety outcome included all procedure-related complications. RESULTS: There was no significant difference in the primary outcome when comparing men and women receiving LBBAP (P = 0.46), whereas the primary outcome was less frequent in women in the BIVP group than men treated with BIVP (P = 0.03). The primary outcome occurred less frequently in men undergoing LBBAP (29.9%) compared to those treated with BIVP (46.5%) (P = 0.004). In women, the incidence of the primary endpoint was 24.14% in the LBBAP group and 36.2% in the BIVP group; however, this difference was not statistically significant (P = 0.23). Complication rates remained consistent across all groups. CONCLUSIONS: Men and women undergoing LBBAP for CRT had similar clinical outcomes. Men undergoing LBBAP showed a lower risk of heart failure-related hospitalizations and all-cause mortality compared to men undergoing BIVP, whereas there was no difference between LBBAP and BIVP in women.
Assuntos
Bloqueio de Ramo , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Feminino , Masculino , Terapia de Ressincronização Cardíaca/métodos , Idoso , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Estudos Prospectivos , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Pessoa de Meia-Idade , Fatores Sexuais , Sistema de Registros , Resultado do Tratamento , Hospitalização/estatística & dados numéricos , Idoso de 80 Anos ou mais , Volume Sistólico/fisiologiaRESUMO
Management strategies for ventricular arrhythmias are guided by the risk of sudden death and severity of symptoms. Patients with a substantial risk of sudden death usually need an implantable cardioverter defibrillator (ICD). Although ICDs effectively end most episodes of ventricular tachycardia or ventricular fibrillation and decrease mortality in specific populations of patients, they have inherent risks and limitations. Generally, antiarrhythmic drugs do not provide sufficient protection from sudden death, but do have a role in reducing arrhythmias that cause symptoms. Catheter ablation is likewise important for reducing the frequency of spontaneous arrhythmias and is curative for some patients, usually those with idiopathic arrhythmias and no heart disease. Arrhythmia surgery is now infrequent, offered by only a few specialised centres for refractory arrhythmias. Advances in understanding of genetic arrhythmia syndromes and in technology for mapping and ablation of ventricular arrhythmias, and enhanced algorithms in implantable devices for rhythm management, have contributed to improved outcomes.
Assuntos
Morte Súbita Cardíaca/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Displasia Arritmogênica Ventricular Direita/genética , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Displasia Arritmogênica Ventricular Direita/terapia , Síndrome de Brugada/fisiopatologia , Síndrome de Brugada/terapia , Reanimação Cardiopulmonar , Ablação por Cateter , Desfibriladores Implantáveis , Eletrocardiografia , Humanos , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/terapia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/genética , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/complicações , Fibrilação Ventricular/genética , Fibrilação Ventricular/fisiopatologiaRESUMO
BACKGROUND: Management of atrial arrhythmias (AA) in orthotopic heart transplant (OHT) patients is challenging. OBJECTIVE: The purpose of this study was to define the mechanisms of these arrhythmias and to evaluate the role of ablation. METHODS: Patients with OHT referred for ablation of AA from 1999 to 2011 were included (n = 15). Entrainment and anatomic 3-D mapping were utilized to identify AA mechanism and guide ablation. RESULTS: The median time from OHT to ablation was 8 years (range: 1 month-16 years). AA types included 1 (7%) AVNRT, 5 (33%) cavotricuspid isthmus (CTI) dependent donor atrial flutter (AFl), 3 (20%) non-CTI-dependent donor AFL (n = 3), focal atrial tachycardia (AT) (n = 2) and in 4 (27%) recipient to donor atria conduction (RDC) that involved the right atrial anastomosis in 3 and left atrial anastamosis in 1 patient. In RDC tachycardia, ablation was performed at the site of earliest donor atrial activation on the suture line. AA in the recipient atria were not targeted. This resulted in acute success in all cases. In most patients 12/15 (80%) only right atrial ablation was necessary. Regardless of surgical technique (bicaval vs biatrial) right-sided AA was most common. Acute success occurred in 14/15 (93%) patients and 3/15 (20%) required repeat Abl for recurrence. There were no major complications. CONCLUSION: AA after OHT are most commonly due to atrial macroreentry, but focal arrhythmias and RDC atrial conduction also occur. Ablation of organized AA is usually successful with low risk, warranting early consideration in preference to medical treatment.