RESUMO
In this study, a Whelk-O1 chiral stationary phase immobilized on 2.5 µm silica particles was employed in nanoLC. Two nanocolumns (180 and 250 mm long, 75 µm id) with a single polymeric organic monolithic outlet frit were packed under high-pressure ultrasonic-assisted packing procedure. The monolithic outlet frit was prepared by thermal polymerization of methacrylate-based monomers affording high-mechanical stability and high-pressure resistance. Very efficient enantioseparations with more than 70 000 plates/m were achieved in normal phase mode by eluting (+/-) acenaphthenol. Nanocolumns were also tested in RP mode by using on-line MS detection with nano-spray ESI ion source. Kinetic performances of columns in RP mode were comparable to those in normal phase-conditions.
Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Nanotecnologia/instrumentação , Fenantrenos/química , Cromatografia Líquida de Alta Pressão/métodos , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Preparações Farmacêuticas/isolamento & purificação , EstereoisomerismoRESUMO
A stationary phase bearing both bridged bis-ureido and free amino groups (USP-HILIC-NH2 -2.5SP) for high-speed hydrophilic interaction liquid chromatography separations was prepared using a one-pot two-step procedure starting from 2.5 µm totally porous silica particles. Highly polar compounds, such as polyols, hydroxybenzoic acids, and sugars, were successfully analyzed in shorter times and with higher peak efficiency, when compared to results obtained with a bidentate urea-type column packed with 5 µm particles. Increased sugarophilicity and better peak shape were attested for the USP-HILIC-NH2 -2.5SP column (100 × 3.2 mm id) when compared with two commercially available UHPLC columns, namely an acquity BEH amide packed with totally porous 1.7 µm microparticles and a HILIC Kinetex column packed with core-shell 2.6 µm particles. Finally, the new column was employed in the separation of complex mixture of sugars (mono-, di-, and oligosaccharides) and in the analysis of beer samples. The resulting chromatograms showed good selectivity and overall resolution, while the catalyzing effect of the free amino moieties resulted in excellent peak shapes and in the absence of split peaks due to sugar anomerization phenomena.
Assuntos
Carboidratos/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Ureia/química , Carboidratos/química , Cromatografia Líquida de Alta Pressão/instrumentação , Interações Hidrofóbicas e HidrofílicasRESUMO
Biochemical processes in living organisms rely on a plethora of molecular reactions and interactions involving chiral molecules, and these processes often show different responses to the enantiomers of exogenous or endogenous chemicals. The interaction of enantiomeric drugs with a target receptor is a paradigmatic example of chirality effects on general biological action and is directly related to the formation of a drug-receptor supramolecular complex. In particular the drug-receptor model can be used to explore the relation of chirality to at least three important issues encountered in supramolecular chemistry: complementarity, preorganization, and (enantio)selectivity. A detailed understanding of those factors governing enantioselectivity of biological receptors is facilitated by the study at molecular level of model systems with simplified structures that are amenable to physico-chemical investigations. Liquid chromatography on chiral stationary phases offers the opportunity to study enantioselective interactions between surface immobilized chiral selectors, viewed as minimalist mimics of macromolecular receptors, and a large set of chiral guests, under a variety of experimental conditions. Indeed, for a significant number of systems, close agreement has been found between retention data gathered by chromatography and association constants measured by spectroscopy in free solution. Chiral supramolecular selectors featuring highly preorganized, medium-sized macrocyclic structures are attractive in this context because they often afford high levels of enantioselectivity and yet have relatively low molecular complexity, thus facilitating the understanding of operative enantioselective recognition mechanisms from easily collected chromatographic data. In the present chapter we first illustrate the general principles of supramolecular chemistry and their integration into the design of liquid chromatographic systems, with particular focus on enantioselective variants based on chiral macrocyclic selectors of natural or synthetic origin. In the second part we discuss the elaboration of enantioselective recognition models from chromatographic data and how these models can be extended to and studied with non-chromatographic systems (free solution by nuclear magnetic resonance, gas phase by mass spectrometry).
Assuntos
Cromatografia Líquida/métodos , Oligopeptídeos/isolamento & purificação , Bibliotecas de Moléculas Pequenas/isolamento & purificação , Antibacterianos/química , Cromatografia Líquida/instrumentação , Éteres de Coroa/química , Ciclodextrinas/química , Fulerenos/química , Glicopeptídeos/química , Cinética , Ligantes , Rotação Ocular , Peptídeos Cíclicos/química , Estereoisomerismo , TermodinâmicaRESUMO
Forced degradation (i.e., stress testing) of small molecule drug substances and products is a critical part of the drug development process, providing insight into the intrinsic stability of a drug that is foundational to the development and validation of stability-indicating analytical methods. There is a lack of clarity in the scientific literature and regulatory guidance as to what constitutes an "appropriate" endpoint to a set of stress experiments. That is, there is no clear agreement regarding how to determine if a sample has been sufficiently stressed. Notably, it is unclear what represents a suitable justification for declaring a drug substance (DS) or drug product (DP) "stable" to a specific forced degradation condition. To address these concerns and to ensure all pharmaceutically-relevant, potential degradation pathways have been suitably evaluated, we introduce a two-endpoint classification designation supported by experimental data. These two endpoints are 1) a % total degradation target outcome (e.g., for "reactive" drugs) or, 2) a specified amount of stress, even in the absence of any degradation (e.g., for "stable" drugs). These recommended endpoints are based on a review of the scientific literature, regulatory guidance, and a forced degradation data set from ten global pharmaceutical companies. The experimental data set, derived from the Campbell et al. (2022) benchmarking study,1 provides justification for the recommendations. Herein we provide a single source reference for small molecule DS and DP forced degradation stress conditions and endpoint best practices to support regulatory submissions (e.g., marketing applications). Application of these forced degradation conditions and endpoints, as part of a well-designed, comprehensive and a sufficiently rigorous study plan that includes both the DS and DP, provides comprehensive coverage of pharmaceutically-relevant degradation and avoids unreasonably extreme stress conditions and drastic endpoint recommendations sometimes found in the literature.
Assuntos
Estabilidade de Medicamentos , Preparações Farmacêuticas , Oxirredução , Hidrólise , Cromatografia Líquida de Alta Pressão/métodosRESUMO
A new chiral stationary phase for ultrahigh-pressure liquid chromatography (UHPLC) applications was prepared by covalent attachment of the Whelk-O1 selector to spherical, high-surface-area 1.7-µm porous silica particles. Columns of varying dimensions (lengths of 50, 75, 100, and 150 mm and internal diameters of 3.0 or 4.6 mm) were packed and characterized in terms of permeability, efficiency, retention, and enantioselectivity, using both organic and water-rich mobile phases. A conventional HPLC Whelk-O1 column based on 5.0-µm porous silica particles and packed in a 250 mm × 4.6 mm column was used as a reference. Van Deemter curves, generated with low-molecular-weight solutes on a 100 mm × 4.6 mm column packed with the 1.7-µm particles, showed H(min) (µm) and µ(opt) (mm/s) values of 4.10 and 5.22 under normal-phase and 3.74 and 4.34 under reversed-phase elution conditions. The flat C term of the van Deemter curves observed with the 1.7-µm particles allowed the use of higher-than-optimal flow rates without significant efficiency loss. Kinetic plots constructed from van Deemter data confirmed the ability of the column packed with the 1.7-µm particles to afford subminute separations with good efficiency and its superior performances in the high-speed regime, compared to the column packed with 5.0-µm particles. Resolutions in the time scale of seconds were obtained using a 50-mm-long column in the normal phase or polar organic mode. The intrinsic kinetic performances of 1.7-µm silica particles are retained in the Whelk-O1 chiral stationary phase, clearly demonstrating the potentials of enantioselective UHPLC in terms of high speed, throughput, and resolution.
Assuntos
Cromatografia Líquida de Alta Pressão , Modelos Teóricos , Polissacarídeos/química , Cinética , Porosidade , Dióxido de Silício/química , EstereoisomerismoRESUMO
Stress testing (also known as forced degradation) of pharmaceutical products has long been recognized as a critical part of the drug development process, providing foundational information related to intrinsic stability characteristics and to the development of stability-indicating analytical methods. A benchmarking study was undertaken by nine pharmaceutical companies and the Brazilian Health Regulatory Agency (Agência Nacional de Vigilância Sanitária, or ANVISA) with a goal of understanding the utility of various stress testing conditions for producing pharmaceutically-relevant chemical degradation of drugs. Special consideration was given to determining whether solution phase stress testing of solid drug products produced degradation products that were both unique when compared to other stress conditions and relevant to the formal drug product stability data. The results from studies of 62 solid dosage form drug products were compiled. A total of 387 degradation products were reported as being observed in stress testing studies, along with 173 degradation products observed in accelerated and/or long-term stability studies for the 62 drug products. Among these, 25 of the stress testing degradation products were unique to the solution phase stress testing of the drug products; however, none of these unique degradation products were relevant to the formal stability data. The relevant degradation products were sufficiently accounted for by stress testing studies that included only drug substance stressing (in solution and in the solid state) and drug product stressing (in the solid state). Based on these results, it is the opinion of the authors that for solid dosage form drug products, well-designed stress testing studies need not include solution phase stress testing of the drug product in order to be comprehensive.
Assuntos
Benchmarking , Estabilidade de MedicamentosRESUMO
Since its identification in the early 1970s, artemisinin, as well as semi-synthetic derivatives and synthetic trioxanes, have been used in malaria therapy. Reduction of artemisinin by NaBH4 produced dihydroartemisinin (DHA), and yielded a new stereochemically labile centre at C-10, which, in turn, provided two interconverting lactol hemiacetal epimers (namely alpha and beta), whose rate of interconversion depends on buffer, pH, and solvent polarity. Since interconversion of the two epimers occurred on a chromatographic time-scale, this prompted a thorough investigation of the phenomenon as a crucial requisite of any analytical method aimed at quantitating this family of drugs. In this critical review we discuss the current importance of the on-column epimerization of DHA in the development of analytical methods aimed at quantifying the drug, with the purpose of identifying the optimal conditions to minimize on-column epimerization while achieving the best selectivity and efficiency of the overall separation.
Assuntos
Antimaláricos/química , Artemisininas/química , Cromatografia Líquida de Alta Pressão , Simulação por Computador , Cristalografia por Raios X , Concentração de Íons de Hidrogênio , Modelos Moleculares , Estrutura Molecular , EstereoisomerismoRESUMO
Supercritical Fluid Chromatography (SFC) has known a strong regain of interest for the last 10 years, especially in the field of pharmaceutical analysis. Besides the development and validation of the SFC method in one individual laboratory, it is also important to demonstrate its applicability and transferability to various laboratories around the world. Therefore, an inter-laboratory study was conducted and published for the first time in SFC, to assess method reproducibility, and evaluate whether this chromatographic technique could become a reference method for quality control (QC) laboratories. This study involved 19 participating laboratories from 4 continents and 9 different countries. It included 5 academic groups, 3 demonstration laboratories at analytical instrument companies, 10 pharmaceutical companies and 1 food company. In the initial analysis of the study results, consistencies within- and between-laboratories were deeply examined. In the subsequent analysis, the method reproducibility was estimated taking into account variances in replicates, between-days and between-laboratories. The results obtained were compared with the literature values for liquid chromatography (LC) in the context of impurities determination. Repeatability and reproducibility variances were found to be similar or better than those described for LC methods, and highlighted the adequacy of the SFC method for QC analyses. The results demonstrated the excellent and robust quantitative performance of SFC. Consequently, this complementary technique is recognized on equal merit to other chromatographic techniques.
Assuntos
Cromatografia com Fluido Supercrítico/normas , Contaminação de Medicamentos/prevenção & controle , Cooperação Internacional , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Cromatografia com Fluido Supercrítico/métodos , Controle de Qualidade , Reprodutibilidade dos TestesRESUMO
In the last years, supercritical fluid chromatography has largely been acknowledged as a singular and performing technique in the field of separation sciences. Recent studies highlighted the interest of SFC for the quality control of pharmaceuticals, especially in the case of the determination of the active pharmaceutical ingredient (API). Nevertheless, quality control requires also the determination of impurities. The objectives of the present work were to (i) demonstrate the interest of SFC as a reference technique for the determination of impurities in salbutamol sulfate API and (ii) to propose an alternative to a reference HPLC method from the European Pharmacopeia (EP) involving ion-pairing reagent. Firstly, a screening was carried out to select the most adequate and selective stationary phase. Secondly, in the context of robust optimization strategy, the method was developed using design space methodology. The separation of salbutamol sulfate and related impurities was achieved in 7min, which is seven times faster than the LC-UV method proposed by European Pharmacopeia (total run time of 50min). Finally, full validation using accuracy profile approach was successfully achieved for the determination of impurities B, D, F and G in salbutamol sulfate raw material. The validated dosing range covered 50 to 150% of the targeted concentration (corresponding to 0.3% concentration level), LODs close to 0.5µg/mL were estimated. The SFC method proposed in this study could be presented as a suitable fast alternative to EP LC method for the quantitative determination of salbutamol impurities.
Assuntos
Albuterol/análise , Cromatografia com Fluido Supercrítico/métodos , Contaminação de Medicamentos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/normas , Cromatografia com Fluido Supercrítico/normas , EstereoisomerismoRESUMO
Fully porous particles of narrow particle size distribution (nPSD) are now commercially available. In this paper, the kinetic performance of columns packed with these particles (1.9µm, 80Å pore size) has been investigated under typical reversed phase conditions by using a mixture of benzene derivatives as probes. The columns exhibited remarkably high efficiency (in the order of 300,000 theoretical plates per meter) and the possibility to be used at relatively high flow rates without loss of performance. These results contrast with previous studies on the same columns. Indeed we have found column efficiency comparable to that reported in previous work but, on the other hand, we could not observe the same dramatic loss of performance when columns were operated at high flow rates. The results presented in this paper, based on a set of six columns with different geometries (2.1 and 3.0 internal diameter×50, 75 and 100mm length), are not consistent with the previously proposed hypothesis that the unusually low intraparticle diffusion, which would characterize these particles, is the origin of the high efficiency of the columns. In a companion paper [1], a detailed investigation of the different terms leading to band broadening will be performed to point out the major contribution to plate height on nPSD columns.
Assuntos
Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Cinética , Modelos Teóricos , Tamanho da Partícula , PorosidadeRESUMO
With the aim of exploring the potential of ultra-fast chiral chromatography for high-throughput analysis, the new sub-2 micron Whelk-O 1 chiral stationary phase (CSP) has been employed in supercritical fluid conditions to screen 129 racemates, mainly of pharmaceutical interest. By using a 5-cm long column (0.46cm internal diameter), a single co-solvent (MeOH) and a 7-min gradient elution, 85% of acidic and neutral analytes considered in this work have been successfully resolved, with resolution (Rs) larger than 2 in more than 65% of cases. Moreover, almost a half of basic samples that, for their own characteristics, are known to be difficult to separate on Whelk-O 1 CSP, have shown Rs greater than 0.3. The screening of the entire library could be accomplished in less than 24h (single run) with 63% of positive score. For well-resolved enantiomers (Rs roughly included between 1 and 3), we show that method transfer from gradient to isocratic conditions is straightforward. In many cases, isocratic ultra-fast separations (with analysis time smaller than 60s) have been achieved by simply employing, as isocratic mobile phase, the eluent composition at which the second enantiomer was eluted in gradient mode. By considering the extension and variety of the library in terms of chemico-physical and structural properties of compounds and numerousness, we believe that this work demonstrates the real potential of the technique for high-throughput enantioselective screening.
Assuntos
Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Cromatografia com Fluido Supercrítico/instrumentação , Ácidos/análise , Ácidos/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Cinética , Bases de Lewis/análise , Bases de Lewis/isolamento & purificação , Bases de Schiff/análise , Bases de Schiff/isolamento & purificação , EstereoisomerismoRESUMO
A rational approach for the design and preparation of two new "Crab-like" totally synthetic, brush-type chiral stationary phases is presented. Enantiopure diamines, namely 1,2-diaminocyclohexane and 1,2-diphenyl-1,2-ethylene-diamine were treated with 3-(triethoxysilyl)propyl isocyanate, to yield reactive ureido selectors that were eventually attached to unmodified silica particles through a stable, bidentate tether, through a facile two-step one-pot procedure. A full chemical characterization of the new materials has been obtained through solid-state NMR (both (29)Si and (13)C CPMAS) spectroscopy. Columns packed with the two Crab-like chiral stationary phases allow for different mechanisms of separation: normal phase liquid chromatography, reversed phase liquid chromatography and polar organic mode and show a high stability at basic pH values. In particular, the Crab-like column containing the 1,2-diphenyl-1,2-ethylene-diamine selector proved a promising candidate for the resolution of a wide range of racemates (including benzodiazepines, N-derivatized amino acids, and free carboxylic acids) both in normal phase and polar organic mode. An Hmin of 9.57 at a µsf of 0.80mm/s (corresponding to 0.8mL/min) was obtained through van Deemter analysis, based on toluene, for the Crab-like column with the 1,2-diphenyl-1,2-ethylene-diamine selector (250mm×4.6mm I.D.), with a calculated reduced height equivalent to a theoretical plate (h) of only 1.91. Finally, comparative studies were performed with a polymeric commercially available P-CAP-DP column in order to evaluate enantioselectivity and resolution of the Crab-like columns.
Assuntos
Cromatografia Líquida de Alta Pressão/instrumentação , Diaminas/química , Ureia/química , Aminoácidos/química , Cicloexilaminas/química , Espectroscopia de Ressonância Magnética , Modelos Químicos , Modelos Moleculares , Naftalenos/química , Solventes/química , Estereoisomerismo , Tolueno/químicaRESUMO
Casein proteins constitute approximately 80% of the proteins present in bovine milk and account for many of its nutritional and technological properties. The analysis of the casein fraction in commercially available pasteurized milk and the study of its time-dependent degradation is of considerable interest in the agro-food industry. Here we present new analytical methods for the study of caseins in fresh and expired bovine milk, based on the use of lab-made capillary organic monolithic columns. An integrated capillary high performance liquid chromatography and high-resolution mass spectrometry (Cap-LC-HRMS) approach was developed, exploiting the excellent resolution, permeability and biocompatibility of organic monoliths, which is easily adaptable to the analysis of intact proteins. The resolution obtained on the lab-made Protein-Cap-RP-Lauryl-γ-Monolithic column (270 mm × 0.250 mm length × internal diameter, L × I.D.) in the analysis of commercial standard caseins (αS-CN, ß-CN and κ-CN) through Cap-HPLC-UV was compared to the one observe using two packed capillary C4 columns, the ACE C4 (3 µm, 150 mm × 0.300 mm, L × I.D.) and the Jupiter C4 column (5 µm, 150 mm × 0.300 mm, L × I.D.). Thanks to the higher resolution observed, the monolithic capillary column was chosen for the successive degradation studies of casein fractions extracted from bovine milk 1-4 weeks after expiry date. The comparison of the UV chromatographic profiles of skim, semi-skim and whole milk showed a major stability of whole milk towards time-dependent degradation of caseins, which was further sustained by high-resolution analysis on a 50-cm long monolithic column using a 120-min time gradient. Contemporarily, the exact monoisotopic and average molecular masses of intact αS-CN and ß-CN protein standards were obtained through high resolution mass spectrometry and used for casein identification in Cap-LC-HRMS analysis. Finally, the proteolytic degradation of ß-CN in skim milk and the contemporary formation of low-molecular-weight proteose-peptones (PP) with exact monoisotopic Mr between 9444.0989 Da and 14098.9861 Da was confirmed through the deconvolution of high resolution mass spectra and literature data.
Assuntos
Caseínas/análise , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Leite/química , Animais , Caseínas/química , Caseínas/metabolismo , Bovinos , Cromatografia Líquida/instrumentação , Peso Molecular , Espectrofotometria UltravioletaRESUMO
We have developed conceptually new stationary phases containing two bidentate urea-type functions suitable for the separation of a wide variety of polar compounds by hydrophilic interaction chromatography (HILIC) through a facile one-pot two-step procedure with the aim of obtaining high hydrolytic stability in a variety of elution conditions. The preparation of the new phases involves a first reaction of 1,2-ethylendiamine with (3-isocyanatopropyl)triethoxysilane to give an intermediate bis-urea with two pendant triethoxysilane functions, followed by anchoring on the silica surface. Two stationary phases were prepared, namely an urea-type stationary phase (USP-HILIC) and an urea-type phase bearing free amino groups (USP-HILIC-NH(2)), whereas silanization with 1,2-bis(trichlorosilyl)ethane yielded USP-HILIC-sil and USP-HILIC-NH(2)-sil phases, respectively. The silanization step aimed at forming a hydrophilic stable coating through cross-linking between adjacent silanols which prevents silica dissolution at alkaline pH. A full chemical characterization of the new materials has been obtained through solid-state NMR (both (29)Si and (13)C CPMAS) spectroscopy. A major application field of the bidentate urea-type stationary phase with free amino groups USP-HILIC-NH(2)-sil was sugars analysis, usually hampered by α/ß anomer peak splitting and instability of the stationary phases under conditions normally employed to suppress it. Complex mixtures of mono-, di- and oligosaccharides were successfully resolved under mild chromatographic conditions, which also allowed an easy interface with mass spectrometry. The potential of such materials was shown in the separation of other highly polar compounds, including polyols, hydroxybenzoic acids, nucleobases, and vitamins.
Assuntos
Cromatografia Líquida/métodos , Ureia/química , Carboidratos/química , Cromatografia Líquida/instrumentação , Interações Hidrofóbicas e Hidrofílicas , Hidroxibenzoatos/química , Sílica Gel/química , Álcoois Açúcares/químicaRESUMO
This paper reports on the thermodynamic and kinetic evaluation of a new ultra-high performance liquid chromatography broad-spectrum Pirkle-type chiral stationary phase (CSP) for enantioselective applications (eUHPLC). The well-known Whelk-O1 selector was covalently immobilized onto 1.7-µm high-surface-area, porous spherical silica particles to produce a totally synthetic, covalently bonded CSP that was packed into 150 mm, 100mm, 75 mm and 50mm columns, either 4.6 or 3.0mm ID. A 100 mm × 4.6 mm ID column was fully characterized from a kinetic and thermodynamic point of view, using as reference a conventional HPLC Whelk-O1 column, 250 mm×4.6mm ID, based on 5-µm porous silica particles. On the eUHPLC column, van Deemter plots generated H(min) values of 3.53 µm for 1,3-dinitrobenzene, at an interstitial mobile phase linear velocity (µ(inter)) of 5.07 mm/s, and H(min) of 4.26 and 4.17 µm for the two enantiomers of acenaphthenol, at µ(inter) of 4.85 mm/s and 4.24 mm/s, respectively. Resolution of 21 enantiomeric pairs including alcohols, epoxides, sulfoxides, phosphine oxides, benzodiazepines and 2-aryloxyproprionic esters used as herbicides, were obtained with significant advantages in terms of efficiency and analysis time. Speed gain factors were calculated for the different column geometries (150 mm, 100mm, 75 mm and 50mm, either 4.6 or 3.0mm ID), with respect to the standard HPLC column (250 mm ×4.6 mm ID), and were as high as 13, in the case of the 50-mm-long column, affording sub-minute separations of enantiomers with excellent resolution factors. In particular, trans-stilbene oxide was resolved in only 10s, while a 50 mm×3.0 mm ID column was used as a compromise between reduced mobile phase consumption (less than 1 mL per analysis) and smaller extra-column band-broadening effect. Given the relatively low viscosity in NP mode, and the excellent permeability of these eUHPLC columns, with backpressure values under 600 bar for a wide range of flow rates, the use of standard HPLC hardware is possible. In this case, however, a significant loss in resolution is observed, compared to the UHPLC instrumentation, if no modifications are introduced in the HPLC apparatus to reduce extra-column variance. The excellent efficiency and selectivity, conjugated with the very high-throughput and the ultra-fast analysis time, prove the potentials of the eUHPLC Whelk-O1 columns in the development of enantioselective UHPLC methods.
Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida de Alta Pressão/instrumentação , EstereoisomerismoRESUMO
The aim of the present study was to extend the use of the "Inverted Chirality Columns Approach (ICCA)" previously developed for the identification and quantitation of the trace enantiomer in highly enriched samples of the camptothecin (CPT) family of drugs to a novel water-soluble CPT derivative, namely namitecan (ST1968), currently undergoing phase I clinical trials as anticancer agent. Namitecan, identified from a series of hydrophilic 7-oxyiminomethyl derivatives, contains a free terminal amino group, which traditionally hampers the analysis under normal-phase HPLC conditions. Nevertheless, commercially available Pirkle-type chiral stationary phases (CSPs) available in both the enantiomeric forms (i.e., having the same bound selector with opposite configuration) mainly operate under normal-phase HPLC conditions. For this reason, namitecan was pre-column N-protected with isocyanates A-D and their sulfur analogues E-H to reduce its polarity by converting the amino group into a fragment compatible with the chiral recognition mechanism (i.e., ureido and thioureido groups). Once the optimal columns system and derivatizing agents were selected, an original enantioselective HPLC-MS/MS technique was developed on the Whelk-O1 CSPs.