Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Gastroenterol Hepatol ; 37(10): 1955-1962, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35945162

RESUMO

BACKGROUND AND AIM: The management of bleeding during endoscopic submucosal dissection (ESD) is critical and related to the procedure time. We collaborated on a new image enhancement algorithm with parameter optimization for clinical use being developed by FUJIFILM Co. and processed white light image data offline to evaluate the effectiveness of this technology. This study aims to evaluate the clinical usefulness of this technology. METHODS: Eighteen video scenes of bleeding points from five gastric ESDs were selected and processed by the new image enhancement algorithm. The time until a bleeding point was found, visibility of a bleeding point, and color abnormality of the submucosal layer were evaluated by ESD experts, ESD trainees, and endoscopy trainees. The color differences between the bleeding point and the surroundings in CIE-L*a*b* color space were calculated in the original and enhanced images. RESULTS: The time until a bleeding point was found in the enhanced videos was significantly shorter than that in the original videos (11.10 s vs 13.85 s) (P = 0.017). On a 5-point (-2 to +2) Likert scale of visibility, the enhanced image was slightly superior to the original (+0.45), and the appearance of the submucosa was comparable between images (+0.14). The color difference among the bleeding areas on the enhanced images was significantly larger than that on the original images (10.93 vs 8.36). CONCLUSION: This novel image enhancement algorithm emphasizes the color difference between a bleeding point and the surrounding area, which would help find bleeding points faster during ESD for the less experienced endoscopists.


Assuntos
Melhoramento Biomédico , Ressecção Endoscópica de Mucosa , Neoplasias Gástricas , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Endoscopia Gastrointestinal , Mucosa Gástrica/diagnóstico por imagem , Mucosa Gástrica/cirurgia , Hemorragia , Humanos , Aumento da Imagem , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia , Tecnologia , Resultado do Tratamento
2.
Endosc Int Open ; 11(12): E1130-E1137, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38094026

RESUMO

Background and study aims Esophageal endoscopic submucosal dissection (ESD) has a higher complication rate than gastric ESD. Scissor-type devices, including the stag beetle (SB) knife, are reportedly safer and have shorter procedure times than tip devices. To clarify the characteristics of the SB knife, we compared the treatment outcomes of esophageal ESD with a tip-type knife to those with an SB knife combination. Patients and methods Between January 2016 and March 2023, clinical data from 197 lesions in 178 patients who underwent esophageal ESD were analyzed retrospectively. Every lesion was assigned to either the tip-type group or the SB group based on the devices with which the submucosa was initially dissected. We compared procedure time and complications and analyzed the risk of muscular exposure using multivariate analysis. Results Procedure time was not significantly different between the tip-type and SB groups (60.3±42.2 min vs. 58.8±29.1 min). The variation in procedure time was significant according to F test P =0.002). Incidence of muscular exposure was significantly lower in the SB group than in the tip-type group (24.5% vs. 11.1%, P =0.016). These differences were significant in resected specimens larger than 21 mm. Procedure time over 60 minutes (odds ratio [OR] 2.5, 95% confidence interval [CI]: 1.15-5.42, P =0.02) was a risk factor for muscular exposure, and submucosal dissection with an SB knife was a safety factor (OR 0.4, 95% CI: 0.18-0.89, P =0.02). Conclusions Performing esophageal ESD with an SB knife is a safe procedure with less variation in procedure time and less muscule exposure.

3.
Intern Med ; 62(17): 2451-2455, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36631094

RESUMO

Objective In general, surface ulceration in gastric gastrointestinal stromal tumor (GIST) is considered a malignant feature; however, the mechanism underlying its formation has not been evaluated in detail. In this study, we analyzed the factors involved in ulceration using resected specimens of gastric GIST. Methods A total of 48 samples were retrospectively analyzed. We examined the association of surface ulceration of gastric GIST with the MIB-1 labeling index, mitotic number, tumor size, endoscopic ultrasound (EUS) findings and growth pattern on computed tomography (CT). Results The proportion of men was significantly higher in the ulceration group than in the non-ulceration group (p=0.04146), whereas age was not significantly different between the groups. Tumor was significantly larger in the ulceration group than in the non-ulceration group (p=0.0048). There was no correlation between tumor size and ulcer number. The MIB-1 index was not related to ulceration, nor were EUS findings. The number of mitotic cells tended to be higher in the ulceration group than in the non-ulceration group (p=0.05988). Intraluminal growth pattern was strongly associated with ulceration (p=0.00019). After a multivariate analysis, the growth pattern was the only factor associated with ulceration of gastric GIST. Conclusion Although formation of surface ulceration in gastric GIST was partially associated with the degree of malignancy, the growth pattern was the most important factor associated with ulceration in gastric GIST.


Assuntos
Tumores do Estroma Gastrointestinal , Neoplasias Gástricas , Masculino , Humanos , Tumores do Estroma Gastrointestinal/complicações , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/patologia , Estudos Retrospectivos , Úlcera/etiologia , Úlcera/complicações , Neoplasias Gástricas/complicações , Neoplasias Gástricas/patologia , Endossonografia/métodos
4.
Medicine (Baltimore) ; 101(28): e29386, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35839022

RESUMO

Gastric endoscopic submucosal dissection (ESD) is increasingly performed in patients receiving antithrombotic therapy. Second-look endoscopy (SLE) has been performed empirically in several clinical settings. We investigated whether SLE omission was associated with an increased risk of postESD bleeding in all patients, including those administered antithrombotic agents. Between July 2016 and June 2018, 229 patients were treated with a clinical pathway for gastric ESD that involved SLE on the day after ESD (SLE group). Between September 2018 and May 2020, 215 patients were treated using a clinical pathway that did not include SLE (nonSLE group). We retrospectively compared the incidence of postESD bleeding among the propensity score-matched cohorts and determined the risk factors for postESD bleeding using multivariate analysis. The propensity score-matched cohorts showed no significant differences in the incidence of postESD bleeding between the SLE (3.2%) and nonSLE (5.1%) groups. Multivariate analysis revealed that the presence of lesions in the lower gastric body (adjusted odds ratio [OR] 2.17, 95% confidence interval [CI] 1.06-4.35, P.03) was a significant risk factor for postESD bleeding during admission, whereas resected specimen size ≥ 40 mm (adjusted OR 3.21, 95% CI 1.19-8.19, P.02) and antiplatelet therapy (adjusted OR 4.16, 95% CI 1.47-11.80, P.007) were significant risk factors after discharge. Complete omission of SLE after gastric ESD does not increase postESD bleeding in clinical practice.

5.
Fujita Med J ; 7(3): 87-98, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35111551

RESUMO

OBJECTIVES: We determined the efficacy of fecal microbiota transplantation (FMT) and subsequent changes in fecal microbiota and short-chain fatty acid (SCFA) levels in patients with ulcerative colitis (UC), Crohn's disease (CD), and recurrent Clostridioides difficile infection (rCDI). METHODS: A filtered solution of Japanese donor feces was endoscopically administered. The efficacy of FMT was evaluated after 8 weeks using the Mayo score, Crohn's Disease Activity Index (CDAI), and the absence of diarrhea with stool toxin negativity in patients with active UC, CD, and rCDI, respectively. For fecal microbiota analysis, the 16S ribosomal RNA gene was sequenced, and fecal SCFA levels were measured. RESULTS: Clinical response was achieved in 5/20 (25%), 3/4 (75%), and 4/4 (100%) patients with UC, CD, and rCDI, respectively. Clinical remission was achieved in 4/20 (20%) and 1/4 (25%) patients with UC and CD, respectively. Linear discriminant analysis illustrated that UC responders had lower counts of Clostridium cluster XIVa before FMT and higher counts after FMT. Higher Fusicatenibacter saccharivorans counts in donors were significantly correlated with 8-week clinical remission. Patients with CD exhibited lower Blautia, Dorea, and Eubacterium counts before FMT and higher Collinsella, Dorea, and Eubacterium counts after FMT, accompanied by functional profiles predictive of SCFA fermentation and elevated fecal butyrate concentrations. Patients with rCDI displayed significantly lower abundances of Clostridium clusters IV and XIVa before FMT and higher abundances after FMT accompanied by elevated fecal propionate concentrations. CONCLUSIONS: FMT exhibited various efficacy against UC, CD, and rCDI by altering the gut microbiota and SCFA production.

6.
Micromachines (Basel) ; 9(6)2018 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-30424194

RESUMO

We propose and demonstrate a simple, low-cost, three-dimensional (3D) shape acquisition method for transparent 3D printed microscopic objects. Our method uses ultraviolet (UV) illumination to obtain high-contrast silhouette images of transparent 3D printed polymer objects. Multiple silhouette images taken from different viewpoints make it possible to reconstruct the 3D shape of this transparent object. A 3D shape acquisition system consisting of a UV light-emitting diode, charge-coupled device camera and a rotation stage was constructed and used to successfully reconstruct the 3D shape of a transparent bunny model produced using micro-stereolithography. In addition, 3D printed pillar array models, with different diameters on the order of several hundred micrometers, were reconstructed. This method will be a promising tool for the 3D shape reconstruction of transparent 3D objects on both the micro- and macro-scale by changing the imaging lens.

7.
Endosc Int Open ; 6(10): E1164-E1170, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30302372

RESUMO

Background and study aims Biliary metallic stents are used to drain unresectable malignant distal biliary obstructions. This study aimed to evaluate the efficacy of a novel 12-mm-diameter covered, self-expandable end bare metal stent (12-mm CSEEMS). Patients and methods We evaluated 99 patients with unresectable malignant distal biliary obstructions treated with covered biliary metallic stents. Of the 99 patients, 33 underwent 12-mm CSEEMS placement between June 2015 and April 2017 (12-mm-CSEEMS group) and 66 underwent 10-mm fully-covered self-expandable metal stent (FCSEMS) placement between January 2010 and July 2015 (10-mm-FCSEMS group). The overall survival (OS), the recurrent biliary obstruction (RBO), cause of RBO, time to RBO (TRBO) and adverse events in 12-mm-CSEEMS group and 10-mm-FCSEMS group were evaluated retrospectively. Results The OS tended to be longer in the 12-mm-CSEEMS group (log rank, P  = 0.081) and TRBO was significantly longer in the 12-mm-CSEEMS group (log rank, P  = 0.001) than in the 10-mm-FCSEMS group. Both univariate (HR, 0.449; 95 % CI, 0.27967 - 0.72215; P  = 0.001) and multivariate (HR, 0.458; 95 % CI, 0.28395 - 0.73744; P  = 0.001) Cox hazard analysis found that risk of RBO was significantly lower in 12-mm CSEEMS than in 10-mm FCSEMS. There were no significant differences between the 12-mm-CSEEMS group and 10-mm-FCSEMS group regarding the cause of RBO and adverse events. Conclusions The 12-mm CSEEMS showed a low risk of RBO compared with 10-mm FCSEMS and was considered to be effective and safe for draining unresectable malignant distal biliary obstruction.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa