Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Eur Radiol ; 29(1): 383-391, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29948090

RESUMO

OBJECTIVES: Most existing models that are in use to model hepatic function through assessment of hepatic gadoxetic acid enhancement kinetics do not consider quantitative measures of gadoxetic excretion. We developed a model that allows a simultaneous quantitation of uptake and excretion of liver specific contrast agents. The aim was to improve the assessment of hepatic synthetic function, and provide quantitative measures of hepatic excretion function. METHODS: Sixteen patients underwent dynamic T1-weighted turbo gradient echo imaging at 1.5 T prior and after bolus injection of gadoxetic acid at 0.1 ml/kg. DCE-images were obtained for 30 min after injection. A dual-inlet two-compartment model was then used to fit the measured liver signal values. Four tissue parameters (extracellular volume fraction, arterial flow fraction, uptake rate and excretion half-time) were extracted for each liver segment. RESULTS: The proposed model provided a good fit to acquired data. Mean values for arterial flow fraction (0.08+-0.04), extracellular volume (0.20±0.08) and uptake rate (4.02 ±1.32 /100 ml/min) were comparable to those obtained with the conventional model (0.08±0.05, 0.21±0.12, and 4.93±1.74), but exhibited significantly less variation and improved fit quality. CONCLUSIONS: The proposed model is more accurate than existing conventional models and provides an additional excretion parameter. KEY POINTS: • Models of hepatic contrast agent uptake can be extended to include excretion. • Including an additional excretion parameter improves accuracy of the model. • Standard diagnostic sequences can be extended to incorporate the model.


Assuntos
Líquidos Corporais/metabolismo , Gadolínio DTPA/farmacocinética , Neoplasias Hepáticas/diagnóstico , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste/farmacocinética , Feminino , Humanos , Fígado/metabolismo , Fígado/fisiopatologia , Testes de Função Hepática , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/fisiopatologia , Masculino , Pessoa de Meia-Idade
2.
Radiology ; 288(3): 764-773, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29786487

RESUMO

Purpose To determine the relationship between diffusion-weighted (DW) liver MR images obtained 4-6 weeks after lobar yttrium 90 (90Y) treatment and overall survival in comparison with PET/CT or established oncologic factors known to affect survival. Materials and Methods The institutional review board approved this prospective intraindividual comparative study in 36 consecutive patients (25 women) with liver-dominant metastases (20 colorectal, 14 breast, two other) (mean age, 60 years ± 10 [standard deviation]) who underwent fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT and DW MRI before and 4-6 weeks after 90Y radioembolization. DW MRI response was defined as a mean minimal apparent diffusion coefficient increase of more than 30%; PET/CT response was defined as a mean maximal standardized uptake value decrease of more than 30%. Kaplan-Meier curves, log-rank test, and multivariable Cox regression analyses were used to compare patient survival as a function of imaging and Response Evaluation Criteria in Solid Tumors (RECIST) response, pretreatment Eastern Cooperative Oncology Group (ECOG) performance status (PS) (0 vs 1), hepatic tumor load (<25% vs ≥25%), and presence versus absence of extrahepatic disease. Results Thirty-five of the 36 patients were observed until death (median survival, 36 weeks). Response was observed with PET/CT in 18 of 36 patients (50%). Median survival was 39 weeks in patients who responded to PET/CT versus 27 weeks in those who did not (P = .60). Response was observed with DW MRI in 24 of 36 patients (67%). Median survival was 53 weeks in DW MRI responders versus 20 weeks in nonresponders (P = .01). At multivariable analysis, DW MRI response was the only independent predictor of survival (P < .01). Response based on RECIST parameters, ECOG PS, hepatic tumor load, and presence of extrahepatic metastases did not correlate with survival. Conclusion In patients with hepatic metastases undergoing 90Y radioembolization, prediction of response to therapy with DW MRI was superior to that with PET/CT and established oncologic factors.


Assuntos
Braquiterapia/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Ítrio , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Análise de Sobrevida
3.
Radiology ; 285(3): 1023-1031, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28799842

RESUMO

Purpose To investigate the efficacy and safety of irreversible electroporation (IRE) in the treatment of hepatic tumors not suitable for thermal ablation (radiofrequency ablation [RFA] or microwave ablation). Materials and Methods This was an institutional review board-approved prospective study in 29 patients (15 men, 14 women; mean age, 63 years ± 12 [standard deviation]) with 43 primary (n = 8) or secondary (n = 35) malignant liver tumors who underwent computed tomography (CT)-guided IRE. All target tumors were located immediately adjacent to major hepatic veins, portal veins, or both; thus, they were not considered suitable for RFA or microwave ablation. Patients underwent postinterventional CT and magnetic resonance (MR) imaging. Systematic follow-up MR imaging was performed for 24 months on average to assess complete ablation, intrahepatic tumor recurrence, and complications. The 95% confidence intervals (CIs) were determined for the rate of bile duct strictures, incomplete ablation, and tumor recurrence. Results Complete ablation was achieved in 40 (93%; 95% CI: 85, 100) of 43 target tumors, with a safety margin of 5-10 mm, and was confirmed at immediate postinterventional CT and MR imaging. In 13 (33%; 95% CI: 18, 47) of 40 completely ablated tumors, intrahepatic tumor recurrence was observed at 2-18 months. However, only two (15%; 95% CI: 0, 35) of these 13 tumors were observed within the ablation zone. In the remaining 11 (85%; 95% CI: 65, 100), tumor growth was observed alongside the needle tract. None of the two true local recurrences occurred at the site of the vessel. All adjacent vessels remained perfused at follow-up. Five (24%; 95% CI: 5, 39) of 21 patients with target tumors adjacent to portal veins developed mild to moderate cholestasis 2-6 weeks after IRE. Conclusion IRE is useful to avoid incomplete ablation secondary to heat-sink effects and damage to major blood vessels; however, needle tract seeding is observed in 26% of treated tumors, and IRE induces sufficient local heating to bile ducts in 24% of ablations. © RSNA, 2017.


Assuntos
Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Eletroporação/métodos , Veias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Veia Porta/diagnóstico por imagem , Doenças Vasculares/etiologia , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/prevenção & controle
4.
Surg Endosc ; 26(5): 1468-75, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22179447

RESUMO

BACKGROUND: Prosthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI. METHODS: Polyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20°. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation. RESULTS: In all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine. CONCLUSION: Loading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors' observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.


Assuntos
Compostos de Ferro , Telas Cirúrgicas/normas , Animais , Desenho de Equipamento , Hérnia Abdominal/cirurgia , Imageamento por Ressonância Magnética , Masculino , Polivinil/uso terapêutico , Próteses e Implantes , Ratos , Ratos Sprague-Dawley
5.
Sci Rep ; 12(1): 12468, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864273

RESUMO

To investigate whether combining L1-regularized iterative sensitivity encoding (SENSE) reconstruction and single-shot echo planar imaging (EPI) is useful in hepatic DWI. Single-shot EPI-DWI with L1-regularized iterative SENSE reconstruction (L1-DWI) and conventional parallel imaging-based reconstruction (conv-DWI) in liver MRI were compared in volunteers and patients. For the patient cohort, 75 subjects (60 ± 13 years) with 349 focal liver lesions (FLL) were included. Patient groups A and B were used to reduce acquisition time or improve spatial resolution, respectively. Image parameters were rated on a 5-point scale. The number of FLLs was recorded; in case of discrepancy, the reason for non-detectability was analyzed. In volunteers, higher signal-to-noise ratio (24.4 ± 5.6 vs. 12.2 ± 2.3, p < 0.001 at b = 0; 19.3 ± 2.8 vs. 9.8 ± 1.6, p < 0.001 at b = 800) and lower standard deviation of the apparent diffusion coefficient-values (0.17 vs. 0.20 mm2/s, p < 0.05) were found on L1-DWI compared to conv-DWI. In patients, image ratings were similar for all parameters except for "conspicuity of FLLs" which was rated significantly lower on L1-DWI vs. conv-DWI (4.7 ± 0.6 vs. 4.2 ± 0.9, p < 0.05) in group A. In five patients, 11/349 FLLs were not detectable on L1-DWI, but on conv-DWI. L1-regularized iterative reconstruction of single-shot EPI DWI can accelerate image acquisition or improve spatial resolution. However, our finding that FLLs were non-detectable on L1-DWI warrants further research.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
6.
Am J Sports Med ; 50(8): 2203-2210, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35666098

RESUMO

BACKGROUND: Retears after rotator cuff repair (RCR) have been associated with poor clinical results. Meaningful data regarding the role of arthroscopic revision RCR are sparse thus far. PURPOSE/HYPOTHESIS: To investigate results after arthroscopic revision RCR. We hypothesized that (1) arthroscopic revision RCR would lead to improved outcomes, (2) the clinical results would be dependent on tendon integrity and (3) tear pattern, tendon involvement, and repair technique would influence clinical and structural results. STUDY DESIGN: Case series; Level of evidence 4. METHODS: During a 40-month period, 100 patients who underwent arthroscopic revision RCR were prospectively enrolled in this multicenter study. Outcomes were evaluated preoperatively, at 6 months (6M), and at 24 months (24M) using the Constant score (CS), the Oxford Shoulder Score (OSS), and the Subjective Shoulder Value (SSV). Tendon integrity at 2 years was analyzed using magnetic resonance imaging. A total of 13 patients (13%) were lost to follow-up, and 14 patients (14%) had a symptomatic retear before the 24M follow-up. RESULTS: All clinical scores improved significantly during the study period (CS: preoperative, 44 ± 16; 6M, 58 ± 22; 24M, 69 ± 19 points; OSS: preoperative, 27 ± 8; 6M, 36 ± 11; 24M, 40 ± 9 points; SSV: preoperative, 43% ± 18%; 6M, 66% ± 24%; 24M, 75% ± 22%) (P < .01). At 2 years, a retear rate of 51.8% (43/83) and a surgical revision rate of 12.6% (11/87) were observed. Mean full-thickness tear size decreased from 5.00 ± 1.61 cm2 to 3.25 ± 1.92 cm2 (P = .041). Although the Sugaya score improved from 4.5 ± 0.9 to 3.7 ± 1.4 (P = .043), tendon integrity did not correlate with better outcome scores. Previous open RCR, involvement of the subscapularis, chondral lesions of Outerbridge grade ≥2, and medial cuff failure were correlated with poorer SSV scores at 2 years (P≤ .047). Patients with traumatic retears had better CS and OSS scores at 2 years (P≤ .039). CONCLUSION: Although arthroscopic revision RCR improved shoulder function, retears were frequent but usually smaller. Patients with retears, however, did not necessarily have poorer shoulder function. Patient satisfaction at 2 years was lower when primary open RCR was performed, when a subscapularis tear or osteoarthritis was present, and when the rotator cuff retear was located at the musculotendinous junction. Patients with traumatic retears showed better functional improvement after revision.


Assuntos
Lacerações , Lesões do Manguito Rotador , Artroscopia/métodos , Humanos , Lacerações/cirurgia , Imageamento por Ressonância Magnética , Estudos Prospectivos , Amplitude de Movimento Articular , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Ruptura/cirurgia , Resultado do Tratamento
7.
Radiology ; 258(2): 446-54, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21079200

RESUMO

PURPOSE: To evaluate the feasibility of magnetic resonance (MR) imaging-guided placement of an active vena cava filter (AVCF) in a swine model, the effectiveness of the system in filtering thrombi, and the detection of thrombi with MR imaging. MATERIALS AND METHODS: This study was approved by the government committee on animal investigations. An AVCF tuned to the Larmor frequency of a 1.5-T MR unit was placed in the inferior vena cava (IVC) of seven pigs under real-time MR imaging guidance. Steady-state free precession sequences with four different flip angles (90°, 40°, 25°, and 15°), T1-weighted turbo spin-echo sequences with two flip angles (90° and 15°), and black-blood proton-density-weighted sequences with a flip angle of 90° were performed before and after filter placement. In six cases, extracorporeally produced thrombi were injected through the femoral access to test filter function. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed before and after filter deployment and compared by using the signed-rank test. RESULTS: All AVCFs were successfully deployed. Significant differences (P < .05) in the SNR and CNR of the IVC were found before and after AVCF placement and between sequences with different flip angles. Intravenous thrombi were caught in all cases and clearly depicted with MR imaging. On black-blood proton-density-weighted images, high-signal-intensity thrombi inside the filter were clearly detectable without any overlaying artifacts. CONCLUSION: MR imaging-guided deployment and monitoring of an AVCF is feasible. The AVCF enhances the SNR and CNR, resulting in clear depiction of thrombi inside the filter without the need for contrast material. Design modifications for improved intracaval fixation and retrieval of the prototype AVCF will be required.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Filtros de Veia Cava , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Suínos
8.
Clin Imaging ; 74: 149-155, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33607595

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the imaging capabilities of the REACT pulse sequence in pelvic venous vessels compared to conventional non-contrast pulse sequences. MATERIALS AND METHODS: In addition to routine MRI venography, non-contrast enhanced REACT pulse sequence was performed in 4 healthy volunteers and 21 patients with suspected or known deep venous thrombosis and post thrombotic syndrome. Acquired images were independently interpreted by two MRI radiologists. The sequence performance was subjectively evaluated on a four-point scale regarding the delineation of small peripheral, midsize and large proximal venous vessels, the imaging of vascular pathologies, and the degradation due to artifacts. To evaluate statistical differences in diagnostic accuracy Friedman's test with Dunn's correction was used. RESULTS: REACT depicted the peripheral veins superior to bTFE and T2-TSE with an average score of 3.39 compared to 2.33 in bTFE and 1.77 in T2-TSE. In midsize vessels REACT performed significantly better than T2-TSE (1.94) and bTFE (2.68) with a score of 3.64. For the large proximal vessels REACT (3.39), bTFE (3.33) and T2-TSE (3.56) performed equally without statistical difference. Visibility of venous pathologies was found to be equal between REACT (3.62), bTFE (3.51) and T2-TSE (3.52). The image degradation due to artifacts was rated best in T2-TSE (3.56), followed by REACT (3.39) and bTFE (3.33). CONCLUSIONS: REACT is a promising tool for the visualization of the pelvic venous system using magnetic resonance imaging.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Abdome , Humanos , Pelve/diagnóstico por imagem , Flebografia
10.
PLoS One ; 11(9): e0163630, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27648953

RESUMO

[This corrects the article DOI: 10.1371/journal.pone.0155717.].

11.
PLoS One ; 11(5): e0155717, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27192201

RESUMO

OBJECT: In MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients. MATERIAL AND METHODS: Five patients with iron-loaded MR-visible inguinal hernia mesh implants were examined at 1.5 Tesla. A gradient echo sequence (GRE; parameters: TR: 8.3ms; TE: 4.3ms; NSA:2; FA:20°; FOV:350mm²) and a PCSI sequence (parameters: TR: 25ms; TE: 4.6ms; NSA:4; FA:20°; FOV:350mm²) with on-resonant proton suppression were performed. SGM maps were calculated using two algorithms. Image quality and mesh delineation were independently evaluated by three radiologists. RESULTS: On GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely "sufficient". CONCLUSION: Both "positive contrast" techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient.

12.
Invest Radiol ; 50(6): 409-15, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25763526

RESUMO

OBJECTIVES: Patients with hepatic metastases who are candidates for Y90-radioembolization (Y90-RE) usually have advanced tumor stages with involvement of both liver lobes. Per current guidelines, these patients have usually undergone several cycles of potentially hepatotoxic systemic chemotherapy before Y90-RE is at all considered, requiring split (lobar) treatment sessions to reduce hepatic toxicity. Assessing response to Y90-RE early, that is, already after the first lobar session, would be helpful to avoid an ineffective and potentially hepatotoxic second lobar treatment. We investigated the accuracy with which diffusion- weighted magnetic resonance imaging (DWI-MRI) and positron emission tomography/computed tomography (PET/CT) can provide this information. METHODS: An institutional review board-approved prospective intraindividual comparison trial on 35 patients who underwent fluorodeoxyglucose PET/CT and DWI-MRI within 6 weeks before and 6 weeks after Y90-RE to treat secondary-progressive liver metastases from solid cancers (20 colorectal, 13 breast, 2 other) was performed. An increase of minimal apparent diffusion coefficient (ADCmin) or decrease of maximum standard uptake value (SUVmax) by at least 30% was regarded as positive response. Long-term clinical and imaging follow-up was used to distinguish true- from false-response classifications. RESULTS: On the basis of long-term follow-up, 23 (66%) of 35 patients responded to the Y90 treatment. No significant changes of metastases size or contrast enhancement were observable on pretreatment versus posttreatment CT or magnetic resonance images.However, overall SUVmax decreased from 8.0 ± 3.9 to 5.5 ± 2.2 (P < 0.0001), and ADCmin increased from 0.53 ± 0.13 × 10(-3) mm2/s to 0.77 ± 0.26 × 10(-3) mm2/s (P < 0.0001). Pretherapeutic versus posttherapeutic changes of ADCmin and SUVmax correlated moderately (r = -0.53). In 4 of the 35 patients (11%), metastases were fluorodeoxyglucose-negative such that no response assessment was possible by PET. In 25 (71%) of the 35 patients, response classification by PET and DWI-MRI was concordant; in 6 (17%) of the 35, it was discordant. In 5 of the 6 patients with discordant classifications, follow-up confirmed diagnoses made by DWI. The positive predictive value to predict response was 22 (96%) of 23 for MRI and 15 (88%) of 17 for PET. The negative predictive value to predict absence was 11 (92%) of 12 for MRI and 10 (56%) of 18 for PET. Sensitivity for detecting response was significantly higher for MRI (96%; 22/23) than for PET (65%; 15/23) (P < 0.02). CONCLUSIONS: Diffusion-weighted magnetic resonance imaging appears superior to PET/CT for early response assessment in patients with hepatic metastases of common solid tumors. It may be used in between lobar treatment sessions to guide further management of patients who undergo Y90-RE for hepatic metastases.


Assuntos
Braquiterapia/métodos , Imagem de Difusão por Ressonância Magnética , Neoplasias Hepáticas/radioterapia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Radioisótopos de Ítrio/uso terapêutico , Feminino , Seguimentos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
13.
J Biomed Mater Res B Appl Biomater ; 102(6): 1165-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24470265

RESUMO

BACKGROUND: Application of a mesh in presence of pneumoperitoneum may cause deformation or wave formation when gas is released. Moreover, mesh shrinkage during subsequent wound healing cannot be detected in vivo without invasive diagnostics. Using MRI-visible polyvinylidene fluoride (PVDF) mesh, the extend of mesh deformation and shrinkage could be objectified by MRI for the first time. MATERIALS AND METHODS: Laparoscopic intraperitoneal onlay mesh (IPOM) implantation was performed in 10 female rabbits using ferro-oxide loaded PVDF meshes. MRI measurements were performed postoperatively at days 1 and 90. After three-dimensional reconstruction of all MRI images the total surface and the effective surface of the implanted mesh were explored and calculated computer-assisted. RESULTS: In all cases, the mesh could be identified in MRI. The subsequent three-dimensional reconstruction always allowed a calculation of the mesh area. In relation to the original size of the used textile implant, we found neither a significant reduction of the effective mesh surface after release of the pneumoperitoneum at day 1 after laparoscopic surgery nor a significant change of the total surface of this large pore mesh by the end of the observation period. CONCLUSIONS: In vivo investigation of mesh surface via MRI could exclude a significant initial reduction of the effective mesh surface after release of pneumoperitoneum, in this IPOM rabbit model. A further subsequent shrinkage of these large pore PVDF meshes could be excluded, as well. Imaging of MRI-visible IPOM mesh turned out to be a sufficient tool to objectify mesh configuration and position in vivo.


Assuntos
Imageamento por Ressonância Magnética , Pneumoperitônio/diagnóstico por imagem , Pneumoperitônio/cirurgia , Polivinil , Telas Cirúrgicas , Animais , Modelos Animais de Doenças , Feminino , Teste de Materiais , Coelhos , Radiografia
14.
Invest Radiol ; 48(4): 200-5, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23344516

RESUMO

PURPOSE: Polymer-based textile meshes for abdominal hernia treatment are invisible by conventional imaging methods, including magnetic resonance imaging (MRI). Integration of iron particles in the mesh base material allows MRI visualization of meshes. Positive-contrast susceptibility imaging (PCSI) was implemented to separate susceptibility-induced voids from proton-deficient voids. The purpose of this study was to compare PCSI with conventional gradient echo and turbo spin echo (TSE) sequences for the in vivo assessment of superparamagnetic iron oxide particle-loaded surgical meshes in an animal model. METHODS AND MATERIALS: Iron-loaded polymer meshes were implanted into the abdominal wall of 10 rabbits. At days 1, 30, and 90 after surgery, conventional gradient echo, TSE, and PCSI were performed at 1.5 T in the sagittal and axial planes. Images were scored by 2 radiologists with respect to mesh visibility, delineation of the surrounding tissue, differentiation from other structures, and overall diagnostic use, on a 4-point scale ranging from 1 (insufficient) to 4 (excellent). The results were compared using Wilcoxon signed-rank tests. The mesh shape, possible deformation or fracture, and possible mesh migration were evaluated on the different pulse sequences and compared with the results at surgery and autopsy. RESULTS: The iron-loaded meshes appeared as hypointense signal voids on gradient echo sequences, as a hyperintense line on PCSI, and as a very thin dark line on TSE images. In all animals, a precise depiction of the mesh location and its spatial configuration and integrity was possible by MRI and confirmed by surgical and autopsy results. In all 4 categories and at all 3 time points of imaging, image quality scores were significantly higher for gradient echo imaging (range, 3.60-3.80) compared with PCSI (range, 3.12-3.42) and TSE (range, 1.64-1.89). At day 90, the image quality ratings of gradient echo and PCSI were comparable. In 2 cases, the complete delineation of mesh borders was impossible because of signal voids of adjacent anatomical structures, whereas PCSI helped achieve this differentiation. CONCLUSION: In this rabbit model of iron-loaded implanted abdominal meshes, standard gradient echo imaging was best suitable to assess implant location, integrity, and configuration. In 2 of 10 animals, PCSI helped achieve a complete delineation of mesh borders.


Assuntos
Hérnia Abdominal/cirurgia , Imageamento por Ressonância Magnética/métodos , Telas Cirúrgicas , Animais , Dextranos , Imageamento Tridimensional , Estudos Longitudinais , Nanopartículas de Magnetita , Polímeros , Coelhos , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa