RESUMO
Here we present a nuclear forensic study of uranium from German nuclear projects which used different geometries of metallic uranium fuel. Through measurement of the (230)Th/(234)U ratio, we could determine that the material had been produced in the period from 1940 to 1943. To determine the geographical origin of the uranium, the rare-earth-element content and the (87)Sr/(86)Sr ratio were measured. The results provide evidence that the uranium was mined in the Czech Republic. Trace amounts of (236)U and (239)Pu were detected at the level of their natural abundance, which indicates that the uranium fuel was not exposed to any major neutron fluence.
RESUMO
We have developed a surface ionization ion-source as part of the JAEA-ISOL (Isotope Separator On-Line) setup, which is coupled to a He/CdI2 gas-jet transport system to determine the first ionization potential of the heaviest actinide lawrencium (Lr, Z = 103). The new ion-source is an improved version of the previous source that provided good ionization efficiencies for lanthanides. An additional filament was newly installed to give better control over its operation. We report, here, on the development of the new gas-jet coupled surface ion-source and on the first successful ionization and mass separation of 27-s (256)Lr produced in the (249)Cf + (11)B reaction.
RESUMO
Capillary electrophoresis (CE) was coupled to ICPMS in order to combine the good performance of this separation technique with the high sensitivity of the ICPMS for the analysis of plutonium and neptunium oxidation states. The combination of a fused-silica capillary with a MicroMist AR 30-I-FM02 nebulizer and a Cinnabar small-volume cyclonic spray chamber yielded the best separation results. With this setup, it was possible to separate a model element mixture containing neptunium (NpO2(+)), uranium (UO2(2+)), lanthanum (La3+), and thorium (Th4+) in 1 M acetic acid. The same conditions were also suitable for the separation of various oxidation states of plutonium and neptunium in different aqueous samples. All separations were obtained within less than 15 min. A detection limit of 50 ppb identical with 2 x 10(-7) M (3-fold standard deviation of a blank) was achieved. To prove the negligible disturbance of the plutonium and neptunium redox equilibria during the CE separations, plutonium and neptunium speciation by CE-ICPMS in acidic solutions was compared with the results of UV/visible absorption spectroscopy and was found to be in good agreement. The CE-ICPMS system was also applied to study the reduction of Pu(VI) in a humic acid-containing groundwater at different pH values.