Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
Eur Spine J ; 32(8): 2796-2804, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37067601

RESUMO

AIM: 2nd and 3rd generation endoscopic spine surgery techniques offer visualisation of familiar inter-laminar anatomy to spinal surgeons. We have prospectively evaluated the clinical outcome, complications and learning curve associated with these techniques in patients with lumbar spine radiculopathy. METHODS: This is a prospective study of 50 consecutive patients with radicular pain from disc herniation and/or lateral recess stenosis. In 6 patients, endoscopy couldn't be done. Operating times, PROM's (VAS, ODI and EQ-5D scores) and complication rates of 44 patients were evaluated after mean FU of 52 months (range 39-65). MRI was used to divide these into protrusions (n = 19), extrusions (n = 17) and lateral recess stenosis (n = 8). Evidence about the learning curve was gathered by curvilinear regression analyses. RESULTS: Using a composite clinical success criterion, 95% patients had a successful outcome, with no major complications. ODI, VAS and EQ-5D scores had a statistically significant improvement and achieved MCID. Revision discectomy rate was only 4.5% (n = 2). MRI based grouping, case sequence and degree of difficulty influenced the duration of surgery and a learning curve was found for protrusions and lateral recess decompressions, but not for extrusions. A learning curve effect was also observed with respect to the ODI. CONCLUSIONS: Although anatomy visualised in 2nd and 3rd generation endoscopy is familiar to spinal surgeons, our learning curve experience suggests a careful and MRI pathology based take up of this technique in clinical practice, despite its clinical safety in our series. LEVEL OF EVIDENCE: Level 3, prospective cohort study.


Assuntos
Discotomia Percutânea , Deslocamento do Disco Intervertebral , Radiculopatia , Humanos , Estudos Prospectivos , Constrição Patológica/cirurgia , Curva de Aprendizado , Endoscopia/efeitos adversos , Endoscopia/métodos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Radiculopatia/diagnóstico por imagem , Radiculopatia/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Discotomia Percutânea/métodos
2.
Knee Surg Sports Traumatol Arthrosc ; 31(8): 3381-3389, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37036473

RESUMO

PURPOSE: Medial patellofemoral ligament reconstruction (MPFL-R) is a recognised surgical procedure for the treatment of recurrent patellofemoral instability with excellent outcomes reported. The aim of this study is to determine if body mass index can influence these outcomes. METHODS: This is a single-centre retrospective analysis of a longitudinal patellofemoral database. Patients with recurrent patellar instability, without patellar alta or severe trochlear dysplasia were treated using a MPFL-R between 2015 and 2019 at The Robert Jones & Agnes Hunt Orthopaedic Hospital. The clinical efficacy following surgery was assessed by Kujula, International Knee Documentation Committee Score (IKDC), and EuroQol-5 score (EQ-5D) at baseline and up to 26 months post-operatively; their safety assessed by complication rate and requirement for further surgery. The effect of Body Mass Index (BMI) on clinical outcome was analysed using linear, curvilinear, and segmented models following propensity score weighting. RESULTS: A total of 97 patients (97 Knees, mean age 25y) were analysed. Of these, 61 patients had a BMI < 30 kg/m2 (mean age 23y, mean BMI 24) of which 7 patients (12.3%) required additional surgery. A further 36 patients had a BMI > 30 kg/m2 (mean age 27y, mean BMI 36) of which 2 patients (5.6%) required additional surgery. The re-dislocation rate was 0% in each BMI group. Both groups had a significantly improved mean outcome following surgery, with improvements in mean IKDC above the minimum clinical important differences (MCID) of 20.5. BMI had an inverted J-shaped association with functional outcome, showing peak outcomes at BMI of 20.5 (95% CI 18.5 to 22.4; IKDC and Kujala) or BMI of 28 (EQ-5D index). No evidence for an association between BMI and complication risk was found. CONCLUSION: BMI influences the functional outcomes in MPFL-R with an inverted J-shaped relation, without evidence it affected the complication or re-dislocation rate. In the absence of patella alta and severe trochlear dysplasia, an isolated MPFL reconstruction is a safe and effective procedure to treat patellar instability, with the best functional outcome in patients with a BMI around 20 to 21. LEVEL OF EVIDENCE: Level III.


Assuntos
Doenças Ósseas , Luxações Articulares , Instabilidade Articular , Luxação Patelar , Articulação Patelofemoral , Humanos , Adulto , Adulto Jovem , Luxação Patelar/cirurgia , Luxação Patelar/complicações , Índice de Massa Corporal , Articulação Patelofemoral/cirurgia , Instabilidade Articular/cirurgia , Instabilidade Articular/etiologia , Estudos Retrospectivos , Luxações Articulares/complicações , Ligamentos Articulares/cirurgia , Patela/cirurgia
3.
Inflammopharmacology ; 31(1): 77-87, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36508130

RESUMO

Psoriatic arthritis (PsA) is a chronic and painful inflammatory immune-mediated disease. It affects up to 40% of people with psoriasis and it is associated with several comorbidities such as obesity, diabetes, metabolic syndrome, and hypertension. PsA is difficult to diagnose because of its diverse symptoms, namely axial and peripheral arthritis, enthesitis, dactylitis, skin changes, and nail dystrophy. Different drugs exist to treat the inflammation and pain. When patients do not respond to conventional drugs, they are treated with biologic drugs. Tumour necrosis factor inhibitors (TNFi's) are commonly given as the first biologic drug; beside being expensive, they also lack efficacy in 50% of patients. A biomarker predicting individual patient's response to TNFi would help treating them earlier with an appropriate biologic drug. This study aimed to review the literature to identify potential biomarkers that should be investigated for their predictive ability. Several such biomarkers were identified, namely transmembrane TNFα (tmTNF), human serum albumin (HSA) and its half-life receptor, the neonatal Fc receptor (FcRn) which is also involved in IgG lifespan; calprotectin, high mobility group protein B1 (HMGB1) and advanced glycation end products (AGEs) whose overexpression lead to excessive production of pro-inflammatory cytokines; lymphotoxin α (LTα) which induces inflammation by binding to TNF receptor (TNFR); and T helper 17 (Th17) cells which induce inflammation by IL-17A secretion.


Assuntos
Antirreumáticos , Artrite Psoriásica , Produtos Biológicos , Recém-Nascido , Humanos , Artrite Psoriásica/diagnóstico , Artrite Psoriásica/tratamento farmacológico , Inibidores do Fator de Necrose Tumoral , Fator de Necrose Tumoral alfa/metabolismo , Inflamação/tratamento farmacológico , Biomarcadores , Produtos Biológicos/uso terapêutico , Antirreumáticos/uso terapêutico
4.
Spinal Cord ; 58(6): 711-715, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31959874

RESUMO

STUDY DESIGN: This is a retrospective longitudinal review. OBJECTIVE: The purpose of this review was to identify predictors of developing clinical scoliosis and compare between traumatic and neurological aetiologies of SCI. SETTING: This study was conducted at the Midland Centre of SCI. METHOD: Case notes of all patients injured at an age up to 18 years and admitted between 1971 and 2013 were reviewed. RESULTS: Sixty-nine individuals were identified, of which seven were excluded: three with pre-existing scoliosis and four with spina bifida. The remaining 62 (44 males, 18 females) had a median age at injury of 17 years (inter quartile range 13-17). Of these, 51 (82%) had traumatic and 11 (18%) had neurological injury. Most (42/51; 82%) of the children who had a traumatic injury were older than 13 years. The risk of developing scoliosis was lower for older patients (RR 0.68 per year, 95% CI 0.52-0.83) or following a traumatic injury (RR 0.36, 95% CI 0.20-0.66). A multivariable analysis based on age and trauma showed that only older age decreased the risk. A robust Receiver Operator Curve analysis suggested 14.6 years as the optimal threshold to predict development of scoliosis within 10 years (Area Under the Curve; AUC 0.83 (95% CI 0.73-0.93), sensitivity 70% (95% CI 50-89%), specificity 89% (95% CI 74-100%). CONCLUSION: Our results suggest that age below 14.6 years was a predictor for scoliosis. Once adjustment is made for age, the incidence of scoliosis does not differ between traumatic and neurological aetiologies of paediatric SCI injury.


Assuntos
Escoliose/etiologia , Traumatismos da Medula Espinal/complicações , Adolescente , Fatores Etários , Criança , Feminino , Humanos , Incidência , Estudos Longitudinais , Masculino , Prognóstico , Estudos Retrospectivos , Risco , Escoliose/diagnóstico , Escoliose/epidemiologia , Sensibilidade e Especificidade , Traumatismos da Medula Espinal/epidemiologia , Traumatismos da Medula Espinal/etiologia , Ferimentos e Lesões/complicações
5.
Eur Cell Mater ; 35: 255-267, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29714398

RESUMO

High hopes have been pinned on regenerative medicine strategies in order to prevent the progression of cartilage damage to osteoarthritis, particularly by autologous chondrocyte implantation (ACI). The loss of chondrocyte phenotype during in vitro monolayer expansion, a necessary step to obtain sufficient cell numbers, may be a key limitation in ACI. In this study, it was determined whether a shorter monolayer expansion approach could improve chondrogenic differentiation. The effects of two supplement types, foetal bovine serum (FBS) and Stemulate™ (a commercial source of human platelet lysate), on the expansion and re-differentiation potential of human chondrocytes, isolated from five individuals, were compared. Chondrocytes were expanded with 10 % FBS or 10 % Stemulate™. Pellets were cultured for 28 d in chondrogenic differentiation medium and assessed for the presence of cartilage matrix molecules and genes associated with chondrogenicity. Stemulate™ significantly enhanced the proliferation rate [average population doubling times: FBS, 25.07 ± 6.98 d (standard error of the mean, SEM) vs. Stemulate™, 13.10 ± 2.57 d (SEM)]. Sulphated glycosaminoglycans (sGAG), total collagen and qRT-PCR analyses of cartilage genes showed that FBS-expanded chondrocytes demonstrated significantly better chondrogenic capacity than Stemulate™-expanded chondrocytes. Histologically, FBS-expanded chondrocyte pellets appeared to be more stable, with a more intense staining for toluidine blue, indicating a greater chondrogenic capacity. Although Stemulate™ positively influenced chondrocyte proliferation, it had a negative effect on chondrogenic differentiation potential. This suggested that, in the treatment of cartilage defects, Stemulate™ might not be the ideal supplement for expanding chondrocytes (which maintained a chondrocyte phenotype) and, hence, for cell therapies (including ACI).


Assuntos
Plaquetas/metabolismo , Cartilagem Articular/citologia , Condrócitos/citologia , Condrogênese , Idoso , Contagem de Células , Diferenciação Celular , Proliferação de Células , Terapia Baseada em Transplante de Células e Tecidos , Células Cultivadas , Colágeno/metabolismo , Matriz Extracelular/metabolismo , Perfilação da Expressão Gênica , Glicosaminoglicanos/metabolismo , Humanos , Pessoa de Meia-Idade
6.
Acta Orthop Belg ; 82(4): 754-761, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29182116

RESUMO

The treatment of developmental dysplasia of the hip (DDH) in children remains controversial. We describe the clinical and radiological outcomes of  47 hips in 43 children treated with open surgery by one surgeon between 2004 and 2008 for DDH. The mean age at operation was 25 months (5 to 113) with a mean follow up of  89 months  (22 to 169). At the latest follow up 40 of the 45 hips where Severin grades were recordable (89%) were graded as excellent or good, Severin class I or II. Clinically significant AVN (grade II to III  according to the Kalamchi and MacEwen classification) was seen in 6  (13%) of the hips. We found a pelvic osteotomy to be a risk factor for AVN  (p 0.02) and age at operation to be a risk factor for poor morphology at final follow up (p 0.03). Over 18 months old a pelvic osteotomy should be performed in selective cases depending on intra-operative stability, but we will now consider doing this as a staged procedure and delaying the osteotomy for a period of time after open reduction to reduce the risk of AVN.


Assuntos
Necrose da Cabeça do Fêmur/epidemiologia , Luxação Congênita de Quadril/cirurgia , Osteotomia/métodos , Complicações Pós-Operatórias/epidemiologia , Criança , Pré-Escolar , Feminino , Seguimentos , Luxação Congênita de Quadril/diagnóstico por imagem , Humanos , Lactente , Masculino , Radiografia
7.
Osteoarthritis Cartilage ; 23(9): 1622-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26003949

RESUMO

OBJECTIVE: To evaluate the potential of ADAMTS-4 (aggrecanase -1) activity in synovial fluid (SF) as a biomarker of knee injury and joint disease. DESIGN: We have measured ADAMTS-4 activity in the synovial fluid of 170 orthopaedic patients with different degrees of joint pathology, using a commercial ADAMTS-4 fluorescence resonance energy transfer (FRET) substrate assay. Patients were classified at arthroscopy as (i) macroscopically normal, (ii) with an injury of the meniscus, anterior cruciate ligament or chondral/osteochondral defects or (iii) with osteoarthritis, and the influence of independent factors (age, patient group, effusion and synovial inflammation) on ADAMTS-4 activity levels was assessed. RESULTS: In most patients (106/170) ADAMTS-4 activity was undetectable; ADAMTS-4 ranged from 0 to 2.8 ng/mL in synovial fluid from patients with an injury, 0-4.1 ng/mL in osteoarthritic patients and 4.0-12.3 ng/mL in patients with large effusions. Four independent variables each significantly influenced ADAMTS-4 activity in synovial fluid (all P < 0.001): age (concordance = 0.69), presence of osteoarthritis (OA) (concordance = 0.66), level of effusion (concordance = 0.78) and inflammation (concordance = 0.68). Not only did effusion influence the amount of ADAMTS-4 activity most strongly, but it also did this in an ordered manner (P < 0.001). CONCLUSIONS: The main finding of this study is that ADAMTS-4 levels in synovial fluid are most strongly correlated with inflammation and severity of effusion in the knee. Further study is required to determine if it could provide a useful tool to aid clinical diagnoses, indicate treatment, to monitor progression of joint degeneration or OA or alternatively the success of treatment.


Assuntos
Proteínas ADAM/análise , Artropatias/enzimologia , Traumatismos do Joelho/enzimologia , Osteoartrite do Joelho/enzimologia , Pró-Colágeno N-Endopeptidase/análise , Líquido Sinovial/química , Proteína ADAMTS4 , Adulto , Biomarcadores/análise , Transferência Ressonante de Energia de Fluorescência , Humanos , Pessoa de Meia-Idade
8.
Acta Orthop Belg ; 80(3): 397-402, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26280614

RESUMO

Hip resurfacing had initially gained acceptance and popularity as it helps preserve femoral bone stock. In this study we tried to answer the following questions; 1. Whether there is a learning curve for hip resurfacing? 2. Is it present in surgeons from non-developer centres? 3. Is it present in surgeons from developer centres as well? The Oswestry outcome centre was setup to serve an independent international registry for collecting, analysing and reporting outcomes following hip resurfacing. Over a 10 year period, 4535 patients (5000 hips) were recruited from different countries and within the UK from different centres in this study by 139 surgeons from 37 different countries. Our study has shown that function can be used to assess the level of surgical competence. The results from this multilevel analysis have helped to answer the questions posed in the introduction. Hip resurfacing is a surgical procedure with a learning phase and this learning effect is more pronounced in non-developer surgeons as compared to developer surgeons. Hip scores can be used to assess proficiency and competence of surgeons undertaking hip resurfacing arthroplasty.


Assuntos
Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Prótese de Quadril , Curva de Aprendizado , Ortopedia/educação , Desenho de Prótese , Sistema de Registros , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Adulto Jovem
9.
Osteoarthritis Cartilage ; 20(9): 988-96, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22659601

RESUMO

OBJECTIVE: To investigate whether Fourier transform infrared imaging spectroscopy (FT-IRIS), a modality based on molecular vibrations, is a viable alternative to histology and immunohistochemistry (IHC) for assessment of tissue quality and patient clinical outcome. METHODS: Osteochondral biopsies were obtained from patients (9-65 months post-surgery) who underwent an autologous chondrocyte implantation (ACI) procedure to repair a cartilage defect (N = 14). The repair tissue was evaluated histologically by OsScore grading, for the presence of types I and II collagen by IHC, and for proteoglycan (PG) distribution and collagen quality parameters by FT-IRIS. Patient clinical outcome was assessed by the Lysholm score. RESULTS: Improvement in Lysholm score occurred in 79% of patients. IHC staining showed the presence of types I and II collagen in all samples, with a greater amount of collagen type II in the deep zone. The amount and location of immunostaining for type II collagen correlated to the FT-IRIS-derived parameters of relative PG content and collagen helical integrity. In addition, the improvement in Lysholm score post-ACI correlated positively with the OsScore, type II collagen (IHC score) and FT-IRIS-determined parameters. Regression models for the relation between improvement in Lysholm score and either OsScore, IHC area score or the FT-IRIS parameters all reached significance (p < 0.01). However, the FT-IRIS model was not significantly improved with inclusion of the OsScore and IHC score parameters. CONCLUSION: Demonstration of the correlation between FT-IRIS-derived molecular parameters of cartilage repair tissue and patient clinical outcome lays the groundwork for translation of this methodology to the clinical environment to aid in the management of cartilage disorders and their treatment.


Assuntos
Cartilagem Articular/cirurgia , Condrócitos/transplante , Procedimentos Ortopédicos/métodos , Adulto , Cartilagem Articular/metabolismo , Colágeno Tipo I/metabolismo , Colágeno Tipo II/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteoglicanas/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier , Transplante Autólogo , Resultado do Tratamento
10.
Osteoarthritis Cartilage ; 17(8): 1009-13, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19272855

RESUMO

OBJECTIVE: Our aim was to determine whether response shift (RS), a change in the internal standards of a patient, occurs in patients treated for full thickness knee cartilage defects. We have also evaluated the effect of functional scores on patient satisfaction after surgery. DESIGN: Self-administered questionnaires were used to evaluate pre- and post-operative and retrospective post-operative scores of 53 patients following knee microfracture. Patient satisfaction, Lysholm, Visual Analogue Scale (VAS) for pain and modified International Knee Documentation Committee (IKDC) scores were evaluated. RS (pre-test-then-test), unadjusted and adjusted treatment effects (UTE and ATE) and their effect sizes were calculated. RESULTS: All four functional outcome measures had a positive RS. The effect size of the RS ranged from around 0.35 for the Lysholm and IKDC2 score to over 0.9 for the VAS pain score. Gender, age, smoking status and time since follow-up did not significantly affect the RS. RS did not differ significantly between the three patient satisfaction groups (P>0.05). Post-operative Lysholm and IKDC1 scores differed most significantly between the satisfaction groups. CONCLUSIONS: All four scores had a significant shift, implying that patients thought they felt worse before the operation in retrospect than they did at the time. The traditional way of assessing treatment effect, difference between post-intervention and pre-intervention functional scores, may be confounded by change in the internal standards of the patient and should take this into account. RS did not affect the clinical interpretation in this case series. Patient-reported satisfaction after surgery is only related to post-operative scores.


Assuntos
Artroplastia Subcondral , Cartilagem Articular/lesões , Cartilagem Articular/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Adulto , Análise de Variância , Artroscopia/métodos , Cartilagem Articular/fisiologia , Feminino , Humanos , Articulação do Joelho/patologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Satisfação do Paciente , Inquéritos e Questionários , Suporte de Carga/fisiologia
11.
J R Soc Interface ; 5(25): 899-907, 2008 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-18077245

RESUMO

A number of bone tissue engineering strategies use porous three-dimensional scaffolds in combination with bioreactor regimes. The ability to understand cell behaviour relative to strain profile will allow for the effects of mechanical conditioning in bone tissue engineering to be realized and optimized. We have designed a model system to investigate the effects of strain profile on bone cell behaviour. This simplified model has been designed with a view to providing insight into the types of strain distribution occurring across a single pore of a scaffold subjected to perfusion-compression conditioning. Local strains were calculated at the surface of the pore model using finite-element analysis. Scanning electron microscopy was used in secondary electron mode to identify cell morphology within the pore relative to local strains, while backscattered electron detection in combination with X-ray microanalysis was used to identify calcium deposition. Morphology was altered according to the level of strain experienced by bone cells, where cells subjected to compressive strains (up to 0.61%) appeared extremely rounded while those experiencing zero and tensile strain (up to 0.81%) were well spread. Osteoid mineralization was similarly shown to be dose dependent with respect to substrate strain within the pore model, with the highest level of calcium deposition identified in the intermediate zones of tension/compression.


Assuntos
Reatores Biológicos , Osso e Ossos/fisiologia , Calcificação Fisiológica/fisiologia , Modelos Anatômicos , Osteócitos/ultraestrutura , Engenharia Tecidual/métodos , Animais , Fenômenos Biomecânicos , Osso e Ossos/ultraestrutura , Cálcio/metabolismo , Células Cultivadas , Análise de Elementos Finitos , Microscopia Eletrônica de Varredura , Ratos
12.
J Biomech ; 40(7): 1467-76, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-16930609

RESUMO

Bone fractures heal through a complex process involving several cellular events. This healing process can serve to study factors that control tissue growth and differentiation from mesenchymal stem cells. The mechanical environment at the fracture site is one of the factors influencing the healing process and controls size and differentiation patterns in the newly formed tissue. Mathematical models can be useful to unravel the complex relation between mechanical environment and tissue formation. In this study, we present a mathematical model that predicts tissue growth and differentiation patterns from local mechanical signals. Our aim was to investigate whether mechanical stimuli, through their influence on stem cell proliferation and chondrocyte hypertrophy, predict characteristic features of callus size and geometry. We found that the model predicted several geometric features of fracture calluses. For instance, callus size was predicted to increase with increasing movement. Also, increases in size were predicted to occur through increase in callus diameter but not callus length. These features agree with experimental observations. In addition, spatial and temporal tissue differentiation patterns were in qualitative agreement with well-known experimental results. We therefore conclude that local mechanical signals can probably explain the shape and size of fracture calluses.


Assuntos
Calo Ósseo/crescimento & desenvolvimento , Análise de Elementos Finitos , Consolidação da Fratura/fisiologia , Modelos Biológicos , Movimento/fisiologia , Calo Ósseo/citologia , Diferenciação Celular , Proliferação de Células , Condrócitos/citologia , Humanos , Células-Tronco Mesenquimais/citologia , Fatores de Tempo
13.
Proc Inst Mech Eng H ; 221(8): 929-42, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18161253

RESUMO

High levels of cobalt and chromium ions are detected in the blood and urine of patients with metal-on-metal (MoM) hip replacement. These elements are released as a result of wear at the bearing surfaces. Wear rates depend on a multitude of factors, which include the bearing geometry, carbon content, manufacturing processes, lubrication, speed and direction of sliding of the surfaces, pattern of loading, and orientation of the components. In-vivo wear of MoM bearings cannot be reliably measured on X-rays because no distinction can be made between the bearing surfaces. Hip simulator studies have shown that wear rates are higher during the initial bedding-in phase and subsequently drop to very low levels. Accordingly, metal ion levels would be expected to decrease with the use of the bearing, measured as implantation time following surgery. However, several clinical studies have found that metal ion levels either gradually rise or fluctuate instead of decreasing to lower levels. Moreover, hip simulator studies predict that large-diameter bearings have lower wear rates than small-diameter bearings. In clinical studies, however, metal levels in patients with large-diameter bearings are unexpectedly higher than those in patients with small-diameter bearings. As a consequence, high cobalt ion levels in patients do not necessarily imply that their MoM bearings produce much wear debris at the time that their levels were measured; it may simply be due to accumulation of wear debris from the preceding time. Exercise-related cobalt rise may overcome this limitation and give a better assessment of the current wear status of a MoM bearing surface than a measure of cobalt levels only.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Materiais Biocompatíveis/análise , Cobalto/análise , Análise de Falha de Equipamento/métodos , Prótese de Quadril , Falha de Equipamento , Humanos
14.
J Bone Joint Surg Br ; 88(6): 828-31, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16720782

RESUMO

The role of bone-graft extenders in impaction revision surgery is becoming increasingly important. Tricalcium phosphate and hydroxyapatite have been shown to be both biocompatible and osteoconductive, yet many surgeons remain reluctant to use them. The difficulty in handling bone-graft extenders can be partly alleviated by using porous particles and adding clotted blood. In an in vitro model we measured the cohesive properties of various impaction graft mixes. Several factors were evaluated including the use of pure bone graft compared with mixes with extender, washing the bone and the addition of clotted blood. Our findings showed that pure allograft bone particles had significantly higher cohesion than when mixed with extender (p < 0.001). Washing had no effect on cohesion. The addition of clotted blood significantly increased the cohesion of both pure bone (p < 0.019) and mixes with pure bone and with porous graft extender (p < 0.044).


Assuntos
Transplante Ósseo/métodos , Materiais Biocompatíveis , Substitutos Ósseos , Fosfatos de Cálcio , Força Compressiva , Durapatita , Cabeça do Fêmur , Humanos , Teste de Materiais/métodos , Reoperação , Estresse Mecânico
15.
J Bone Joint Surg Br ; 88(6): 832-6, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16720783

RESUMO

The use of impaction bone grafting during revision arthroplasty of the hip in the presence of cortical defects has a high risk of post-operative fracture. Our laboratory study addressed the effect of extramedullary augmentation and length of femoral stem on the initial stability of the prosthesis and the risk of fracture. Cortical defects in plastic femora were repaired using either surgical mesh without extramedullary augmentation, mesh with a strut graft or mesh with a plate. After bone impaction, standard or long-stem Exeter prostheses were inserted, which were tested by cyclical loading while measuring defect strain and migration of the stem. Compared with standard stems without extramedullary augmentation, defect strains were 31% lower with longer stems, 43% lower with a plate and 50% lower with a strut graft. Combining extramedullary augmentation with a long stem showed little additional benefit (p = 0.67). The type of repair did not affect the initial stability. Our results support the use of impaction bone grafting and extramedullary augmentation of diaphyseal defects after mesh containment.


Assuntos
Artroplastia de Quadril/métodos , Transplante Ósseo/métodos , Fraturas do Fêmur/etiologia , Fêmur/cirurgia , Complicações Pós-Operatórias/etiologia , Fraturas do Fêmur/fisiopatologia , Fêmur/fisiopatologia , Articulação do Quadril/cirurgia , Prótese de Quadril , Humanos , Complicações Pós-Operatórias/fisiopatologia , Falha de Prótese , Reoperação/métodos , Fatores de Risco , Estresse Mecânico
16.
J Hand Surg Br ; 31(2): 208-12, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16361004

RESUMO

A new bioresorbable composite cannulated screw has been developed for small bone fracture fixation. The LG ("Little Grafter") screw is manufactured from Biosteon, which is a composite of poly L-lactic acid and hydroxyapatite. This study aimed to compare interfragmentary compression generated by this new screw with conventional metal screws commonly used in scaphoid fracture fixation. Four small metallic screws were compared with the LG screw, using a bone model produced from rigid polyurethane foam. The screws included the Acutrak, Asnis III, Herbert and Herbert-Whipple screws. The mean maximum compression forces for the LG screw, the Asnis and the Acutrak were comparable (LG 32.3 N, Asnis 32.8 N, Acutrak 38.3 N), whereas those using the Herbert and the Herbert-Whipple screw were significantly lower (Herbert 21.8 N, Herbert-Whipple 19.9 N). The bioresorbable LG screw has been shown to have good compressive properties compared to commonly used small bone fragment compression screws.


Assuntos
Implantes Absorvíveis , Parafusos Ósseos , Força Compressiva/fisiologia , Durapatita , Ácido Láctico/análogos & derivados , Polímeros , Poliuretanos , Humanos , Osso Escafoide/cirurgia
17.
J Orthop ; 13(4): 450-454, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27857480

RESUMO

BACKGROUND/AIMS: Cobalt and chromium are released from MOM hips and their precise nature (ions/particles) is not known. Their distribution in serum, plasma, and whole blood may help to determine their nature. METHODS: We measured cobalt and chromium concentrations in plasma, serum, and whole blood samples of patients with resurfacing MOM hips. RESULTS: We found that chromium concentration was highest in plasma, followed by serum and whole blood. Chromium and cobalt concentrations were higher in serum and plasma, compared to whole blood. CONCLUSION: We, therefore, suggest that in future cobalt and chromium concentrations shall be reported using plasma samples.

18.
Bone Joint Res ; 5(8): 328-37, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27496913

RESUMO

OBJECTIVES: Wound complications are reported in up to 10% hip and knee arthroplasties and there is a proven association between wound complications and deep prosthetic infections. In this randomised controlled trial (RCT) we explore the potential benefits of a portable, single use, incisional negative pressure wound therapy dressing (iNPWTd) on wound exudate, length of stay (LOS), wound complications, dressing changes and cost-effectiveness following total hip and knee arthroplasties. METHODS: A total of 220 patients undergoing elective primary total hip and knee arthroplasties were recruited into in a non-blinded RCT. For the final analysis there were 102 patients in the study group and 107 in the control group. RESULTS: An improvement was seen in the study (iNPWTd) group compared to control in all areas. Peak post-surgical wound exudate was significantly reduced (p = 0.007). Overall LOS reduction (0.9 days, 95% confidence interval (CI) -0.2 to 2.5) was not significant (p = 0.07) but there was a significant reduction in patients with extreme values of LOS in the iNPWTd group (Moses test, p = 0.003). There was a significantly reduced number of dressing changes (mean difference 1.7, 95% CI 0.8 to 2.5, p = 0.002), and a trend to a significant four-fold reduction in reported post-operative surgical wound complications (8.4% control; 2.0% iNPWTd, p = 0.06). CONCLUSIONS: Based on the results of this RCT incisional negative pressure wound therapy dressings have a beneficial role in patients undergoing primary hip and knee arthroplasty to achieve predictable length of stay, especially to eliminate excessive hospital stay, and minimise wound complications.Cite this article: S. L. Karlakki, A. K. Hamad, C. Whittall, N. M. Graham, R. D. Banerjee, J. H. Kuiper. Incisional negative pressure wound therapy dressings (iNPWTd) in routine primary hip and knee arthroplasties: A randomised controlled trial. Bone Joint Res 2016;5:328-337. DOI: 10.1302/2046-3758.58.BJR-2016-0022.R1.

19.
Am J Sports Med ; 44(5): 1249-59, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26965681

RESUMO

BACKGROUND: Structural and functional outcome of bone graft with first- or second-generation autologous chondrocyte implantation (ACI) in treating cartilage and subchondral bone defect has not been reported previously. PURPOSE: To evaluate the outcome of simultaneous transplantation of an autologous bone plug with first- or second-generation ACI for restoration of concomitant subchondral bone and full-thickness cartilage defect in the femoral condyle of the knee. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Seventeen patients (mean ± SD age, 27 ± 7 years; range, 17-40 years)-12 with osteochondritis dissecans (International Cartilage Repair Society [ICRS] grades 3 and 4) and 5 with an isolated osteochondral defect (ICRS grade 4)-had the defect reconstructed with implantation of a unicortical autologous bone graft combined with ACI (the OsPlug technique). Functional outcome was assessed with Lysholm scores obtained preoperatively and at 1 and 5 years postoperatively. The repair site was evaluated with the Oswestry Arthroscopy Score (OAS), MOCART score (magnetic resonance observation of cartilage repair tissue), and ICRS II histology score. Formation of a subchondral lamina and lateral integration of the bone grafts were evaluated from magnetic resonance imaging scans. RESULTS: The mean defect size was 4.5 ± 2.6 cm(2) (range, 1-9 cm(2)), and the mean depth was 11.3 ± 5 mm (range, 5-18 mm). The preoperative Lysholm score improved from 45 (interquartile range [IQR], 24; range, 16-79) to 77 (IQR, 28; range, 41-100) at 1 year (P = .001) and 70 (IQR, 35; range, 33-91) at 5 years (P = .009). The mean OAS of the repair site was 6.2 (range, 0-9) at a mean of 1.3 years. The mean MOCART score was 61 ± 22 (range, 20-85) at 2.6 ± 1.8 years. Histology demonstrated generally good integration of the repair cartilage with the underlying bone. Poor lateral integration of the bone graft, as assessed on magnetic resonance imaging scan, and a low OAS were significantly associated with a poor Lysholm score and failure. A total of 3 patients had treatment failure, with 1 requiring total knee replacement at 5 years (Lysholm score of 33 at failure) and the other 2 requiring further surgical intervention because of persistent symptoms at 2 and 4 years, respectively (both had Lysholm score of 45 at failure). The Lysholm score in these patients before failure were still noted to be higher than at the preoperative level. CONCLUSION: The OsPlug technique shows significant improvement of functional outcome for up to 5 years in patients with high-grade osteochondritis dissecans or osteochondral defect. This is the first report describing association of bone graft integration with functional outcome after such a procedure. It also demonstrates histologic evidence of integration of the repair cartilage with the underlying bone graft.


Assuntos
Transplante Ósseo/métodos , Condrócitos/transplante , Articulação do Joelho/cirurgia , Osteocondrite Dissecante/cirurgia , Adolescente , Adulto , Humanos , Imageamento por Ressonância Magnética , Osteocondrite Dissecante/diagnóstico por imagem , Adulto Jovem
20.
J Bone Joint Surg Br ; 87(5): 656-63, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15855367

RESUMO

Clinical experience of impaction bone grafting for revision knee arthroplasty is limited, with initial stability of the tibial tray emerging as a major concern. The length of the stem and its diameter have been altered to improve stability. Our aim was to investigate the effect of the type of stem, support of the rim and graft impaction on early stability of the tray. We developed a system for impaction grafting of trays which we used with morsellised bone in artificial tibiae. Trays with short, long thick or long thin stems were implanted, with or without support of the rim. They were cyclically loaded while measuring relative movement. Long-stemmed trays migrated 4.5 times less than short-stemmed trays, regardless of diameter. Those with support migrated 2.8 times less than those without. The migration of short-stemmed trays correlated inversely with the density of the impacted groups. That of impaction-grafted tibial trays was in the range reported for uncemented primary trays. Movements of short-stemmed trays without cortical support were largest and sensitive to the degree of compaction of the graft. If support of the rim was sufficient or a long stem was used, impacted morsellised bone graft achieved adequate initial stability.


Assuntos
Transplante Ósseo/métodos , Prótese do Joelho , Tíbia/transplante , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Humanos , Desenho de Prótese , Reoperação , Estresse Mecânico , Tíbia/fisiologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa