1.
Kyobu Geka ; 74(2): 99-102, 2021 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-33976012

RESUMO

Previously, we performed passive orthostatism using a tilt table for the purpose of early mobilization in intensive care unit patients after cardiovascular surgery. In this study, we introduced VitalGo Total Lift Bed( TLB), which does not require patient-transfer before passive orthostatism, to reduce the burden on patients and medical staff. No obvious adverse events were found throughout the study. In the TLB group, number of medical staff required to perform the passive orthostatism was significantly less compared to the conventional tilt table group.


Assuntos
Cuidados Críticos , Deambulação Precoce , Humanos
2.
Kyobu Geka ; 73(3): 183-186, 2020 Mar.
Artigo em Japonês | MEDLINE | ID: mdl-32393699

RESUMO

Passive orthostatism using a tilt table was introduced in patients with impaired oxygenation [Pao2/Fio(2 P/F) ratio < 300] after cardiovascular surgery. Our passive orthostatism protocol was as follows. Patient was transferred to a tilt table under endotracheal intubation with pulmonary artery catheter monitoring, and rested for 10 minutes in a supine position, followed by 45-degree tilt for 5 minutes, and then passive orthostatism at 60-degree for 25 minutes. P/F ratio was significantly improved during passive orthostatism. Improvement in P/F ratio was confirmed even 1 hour after completion of the protocol. No obvious adverse events were found throughout the protocol. On average, 15 hours (2~72 hours, median 4 hours) after the introduction of passive orthostatism, weaning from respirator was achieved.


Assuntos
Pulmão , Humanos , Oxigênio
3.
Kyobu Geka ; 72(11): 897-900, 2019 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-31588104

RESUMO

For safe and effective drainage in patients with pleural effusion after cardiac surgery, ultrasound-guided thoracocentesis was carried out under standing with assistance of a tilt table. Thoracocentesis was performed in 5( 11%) of the 44 patients who were treated under passive orthostatism using a tilt table. Four cases were under intubated-ventilator assist, and 2 cases were under intraaortic balloon pumping( IABP). No adverse events occurred. Thoracocentesis under standing with assistance of a tilt table can be safely performed.