Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 88(1): 51-9, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26331782

RESUMO

BACKGROUND: Scoring balloons produce excellent acute results in the treatment of in-stent restenosis (ISR), fibro-calcific and bifurcation lesions but have not been shown to affect the restenosis rate. A novel paclitaxel-coated scoring balloon (SB) was developed and tested to overcome this limitation. METHODS AND RESULTS: SB were coated with paclitaxel admixed with a specific excipient. Patients at four clinical sites in Germany and one in Brazil with ISR of coronary bare metal stent (BMS) were randomized 1:1 to treatment with either a drug-coated or uncoated SB. Baseline and 6-month follow-up quantitative coronary angiography was performed by an independent blinded core lab and all patients will be evaluated clinically for up to one year. The primary endpoint was angiographic in-segment late lumen loss (LLL). Secondary endpoints included the rate of clinically driven target lesion revascularization (TLR), composite of major adverse cardiovascular events (MACE), stent thrombosis and other variables. Sixty-one patients were randomized (28 uncoated and 33 drug-coated SB); mean age 65 years, males 72%, and presence of diabetes 39%. At 6-month angiography, in-segment LLL was 0.48 ± 0.51 mm in the uncoated SB group versus 0.17 ± 0.40 mm in the drug-coated SB group (P = 0.01; ITT analysis). The rate of binary restenosis was 41% in the uncoated SB group versus 7% in the drug-coated SB group (P = 0.004). The MACE rate was 32% with the uncoated SB vs. 6% in the drug-coated SB group (P = 0.016). This difference was primarily due to the reduced need for clinically driven TLR in the coated SB group (3% vs. 32% P = 0.004). CONCLUSIONS: A novel paclitaxel-coated coronary SB has been developed and successfully used in a first-in-human randomized controlled trial [ClinicalTrials.gov Identifier: NCT01495533]. © 2015 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Brasil , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Alemanha , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Retratamento , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento
2.
JACC Cardiovasc Interv ; 15(7): 770-779, 2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35305906

RESUMO

OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB). BACKGROUND: There is increasing clinical evidence for the treatment of coronary de novo disease using drug-coated balloons. However, it is unclear whether paclitaxel remains the drug of choice or if sirolimus is an alternative, in analogy to drug-eluting stents. METHODS: Seventy patients with coronary de novo lesions were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, B. Braun Melsungen; 4 µg/mm2) with a PCB (SeQuent Please, B. Braun Melsungen; 3 µg/mm2). The primary endpoint was angiographic late lumen loss (LLL) at 6 months. Secondary endpoints included major adverse cardiovascular events and individual clinical endpoints such as cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis. RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment LLL was 0.01 ± 0.33 mm in the PCB group versus 0.10 ± 0.32 mm in the SCB group. The mean difference between SCB and PCB was 0.08 (95% CI: -0.07 to 0.24). Noninferiority at a predefined margin of 0.35 was shown. However, negative LLL was more frequent in the PCB group (60% of lesions vs 32% in the SCB group; P = 0.019). Major adverse cardiovascular events up to 12 months also did not differ between the groups. CONCLUSIONS: This first-in-human comparison of a novel SCB with a crystalline coating showed similar angiographic outcomes in the treatment of coronary de novo disease compared with a clinically proven PCB. However, late luminal enlargement was more frequently observed after PCB treatment. (Treatment of Coronary De-Novo Stenosis by a Sirolimus Coated Balloon or a Paclitaxel Coated Balloon Catheter Malaysia [SCBDNMAL]; NCT04017364).


Assuntos
Angioplastia Coronária com Balão , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Reestenose Coronária , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Humanos , Paclitaxel/efeitos adversos , Estudos Prospectivos , Sirolimo/efeitos adversos , Resultado do Tratamento
3.
Cardiovasc Intervent Radiol ; 42(7): 949-955, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30843092

RESUMO

PURPOSE: In view of a recent meta-analysis reporting increased mortality following angioplasty with paclitaxel-coated devices in peripheral arteries, we performed a patient-level 2-year mortality analysis based on pooled original data of four randomized controlled trials (THUNDER, FEMPAC, PACIFIER and CONSEQUENT). METHODS AND RESULTS: Clinical data of four randomized controlled trial were pooled to assess 2-year mortality following paclitaxel-coated balloon (PCB) angioplasty compared to angioplasty without paclitaxel (control group). A logistic regression model was applied to identify potential predictors of mortality. At two years, 13 of 185 (7.0%) patients had died in the control group and 16/184 (8.7%) in the PBC group, p = 0.55. Kaplan-Meier analysis revealed no significant difference from all-cause death at 2 years (log rank p = 0.54). Causes of death were well balanced between the groups with no pattern or trend in favour of any specific causes in the PBC group. Logistic regression revealed that treatment groups (controls or PBC) were not a predictor of 2-year mortality. The only predictor for mortality was patient age ≥ 75 years. The delivered paclitaxel doses per patient were not significantly different in patients that died and those who did not die during the 24-month follow-up (5.300 ± 4.224 µg vs. 6.248 ± 4.629 µg, p = 0.433). CONCLUSIONS: Based on original patient-level data of four pooled randomized controlled trials, we found no increase in 2-year mortality in patients treated with PCB compared to control patients treated with uncoated balloons. Causes of death were well balanced between PCB and control patients.


Assuntos
Angioplastia com Balão/métodos , Materiais Revestidos Biocompatíveis/uso terapêutico , Artéria Femoral/patologia , Paclitaxel/uso terapêutico , Artéria Poplítea/patologia , Neoplasias Vasculares/terapia , Fatores Etários , Idoso , Antineoplásicos Fitogênicos/administração & dosagem , Antineoplásicos Fitogênicos/uso terapêutico , Materiais Revestidos Biocompatíveis/administração & dosagem , Bases de Dados Factuais , Desenho de Equipamento , Feminino , Seguimentos , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Paclitaxel/administração & dosagem , Estudos Prospectivos , Resultado do Tratamento , Neoplasias Vasculares/patologia
4.
Cardiovasc Intervent Radiol ; 42(7): 1055, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30863966

RESUMO

In their recently published pooled analysis of four drug-coated balloon (DCB) studies, which focused on the impact of patient and lesion characteristics on LLL at 6 months (Albrecht T et al. Cardiovasc Intervent Radiol. 2018 Dec 11. https://doi.org/10.1007/s00270-018-2137-3 ), the authors reported slightly inaccurate 2-year mortality rates.

5.
Cardiovasc Intervent Radiol ; 42(4): 495-504, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30539236

RESUMO

OBJECTIVES: The principal objective of this pooled analysis was to investigate various patient and lesion characteristics on late lumen loss (LLL) after drug-coated balloon (DCB) angioplasty. BACKGROUND: Four randomized controlled trials (THUNDER, FEMPAC, PACIFIER, CONSEQUENT) were pooled to investigate the influence of various patient and lesion characteristics on DCB angioplasty and on plain old balloon angioplasty (POBA) in patients with femoropopliteal artery disease. METHODS: Angiographic data from 355 patients were pooled to assess the impact of patient (demographics, cardiovascular risk factors, cardiovascular co-morbidities, Rutherford stages) and lesion-/procedure-related (location, occlusion, length, restenosis, calcification, subintimal crossing, post-dilatation, dissection, stenting) characteristics on LLL. Linear regression models were utilized with LLL as the dependent variable to determine the predictive value of cardiovascular and lesion-/procedure-related factors. RESULTS: Observational statistics revealed that LLL was lower in the DCB group as compared to POBA independent of all tested patient variables. LLL after DCB was also independent of most lesion and procedural characteristics except for lesion length and bailout stenting. LLL increased with lesion length in both treatment groups. Bailout stenting did not improve LLL in the DCB group but did so in the POBA group (0.74 ± 1.07 mm vs. 1.22 ± 1.36 mm, p = 0.043). CONCLUSIONS: DCB was superior to POBA for all tested patient subgroups and lesion subgroups. Our results suggest that all patients and lesions benefit to a similar degree from the use of DCB. DCB-PTA should therefore be preferred to POBA in all patients with steno-occlusive femoropopliteal lesions.


Assuntos
Angioplastia com Balão/métodos , Arteriopatias Oclusivas/cirurgia , Artéria Femoral/cirurgia , Artéria Poplítea/cirurgia , Fatores Etários , Idoso , Angiografia Digital , Arteriopatias Oclusivas/diagnóstico por imagem , Materiais Revestidos Biocompatíveis , Feminino , Artéria Femoral/diagnóstico por imagem , Nível de Saúde , Humanos , Masculino , Paclitaxel/administração & dosagem , Artéria Poplítea/diagnóstico por imagem , Estudos Prospectivos , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Moduladores de Tubulina/administração & dosagem
6.
Catheter Cardiovasc Interv ; 88(1): 51-59, 2016. ilus, tab, graf
Artigo em Inglês | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1061852

RESUMO

Scoring balloons produce excellent acute results in the treatment of instentrestenosis (ISR), fibro-calcific and bifurcation lesions but have not been shown toaffect the restenosis rate. A novel paclitaxel-coated scoring balloon (SB) was developedand tested to overcome this limitation. Methods and Results: SB were coatedwith paclitaxel admixed with a specific excipient. Patients at four clinical sites inGermany and one in Brazil with ISR of coronary bare metal stent (BMS) were randomized1:1 to treatment with either a drug-coated or uncoated SB. Baseline and 6-monthfollow-up quantitative coronary angiography was performed by an independent blindedcore lab and all patients will be evaluated clinically for up to one year. The primaryendpoint was angiographic in-segment late lumen loss (LLL). Secondary endpoints included the rate of clinically driven target lesion revascularization (TLR), composite ofmajor adverse cardiovascular events (MACE), stent thrombosis and other variables.Sixty-one patients were randomized (28 uncoated and 33 drug-coated SB); mean age65 years, males 72%, and presence of diabetes 39%. At 6-month angiography, insegmentLLL was 0.48 6 0.51 mm in the uncoated SB group versus 0.17 6 0.40 mm inthe drug-coated SB group (P 5 0.01; ITT analysis). The rate of binary restenosis was41% in the uncoated SB group versus 7% in the drug-coated SB group (P 5 0.004). TheMACE rate was 32% with the uncoated SB vs. 6% in the drug-coated SB group(P 5 0.016). This difference was primarily due to the reduced need for clinically drivenTLR in the coated SB group (3% vs. 32% P 5 0.004). Conclusions: A novel paclitaxelcoatedcoronary SB has been developed and successfully used in a first-in-human randomized controlled trial...


Assuntos
Difusão de Inovações , Doença das Coronárias
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa