Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Ophthalmic Physiol Opt ; 44(4): 757-768, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38240175

RESUMO

PURPOSE: To assess the impact of 3 months of orthokeratology (ortho-k) contact lenses (CLs) for myopia correction on the corneoscleral profile, as changes in scleral geometry could serve as indirect evidence of alteration in the corneal biomechanical properties. METHODS: Twenty subjects (40 eyes) were recruited to wear ortho-k lenses overnight; however, after discontinuation (two CL fractures, one under-correction and two non-serious adverse events), 16 subjects (31 eyes) finished a 3-month follow-up. Corneoscleral topographies were acquired using the Eye Surface Profiler (ESP) system before and after 3 months of lens wear. Steep (SimKs) and flat (SimKf) simulated keratometry and scleral sagittal height measurements for 13-, 14- and 15-mm chord lengths were automatically calculated by the ESP software. Additionally, sagittal height and slope were calculated in polar format from 21 radii (0-10 mm from the corneal apex) at 12 angles (0-330°). Linear mixed models were fitted to determine the differences between visits. RESULTS: SimKs and SimKf were increased significantly (p ≤ 0.02). The sagittal height in polar format increased significantly (p = 0.046) at a radius of 2.5 mm for 150°, 180°, 210° and 240° orientations and at a radius of 3.0 mm for 210°. Additionally, the slope in polar format significantly decreased (p ≤ 0.04) at radii ranges of 0.0-0.5, 0.5-1.0 and 1.0-1.5 mm for multiple angles and at a radii range of 5.0-5.5 mm for 90°. It also increased significantly (p ≤ 0.045) at a radii range of 1.5-2.0 mm for 30° and at radii ranges of 2.0-2.5, 2.5-3.0 and 3.0-3.5 mm for multiple angles. No significant changes were found for any parameter measured from the scleral area. CONCLUSIONS: Three months of overnight ortho-k lens wear changed the central and mid-peripheral corneal geometry as expected, maintaining the peripheral cornea and the surrounding sclera stability.


Assuntos
Córnea , Topografia da Córnea , Miopia , Procedimentos Ortoceratológicos , Refração Ocular , Esclera , Humanos , Procedimentos Ortoceratológicos/métodos , Masculino , Feminino , Miopia/fisiopatologia , Miopia/terapia , Córnea/diagnóstico por imagem , Adulto Jovem , Refração Ocular/fisiologia , Lentes de Contato , Adolescente , Adulto , Seguimentos , Acuidade Visual/fisiologia , Fenômenos Biomecânicos
2.
Ophthalmic Physiol Opt ; 44(1): 124-130, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37974449

RESUMO

PURPOSE: To assess the reliability and agreement of non-invasive break-up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques. METHODS: In this prospective cross-sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire-8, underwent NIBUT assessment with the CL in situ. The CA-800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively. The within-subject repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between the devices was compared using the Bland-Altman method. RESULTS: A total of 141 CL wearers (51 male and 90 female) with a mean age of 33.6 (SD = 12.2) years were included. The repeatability and ICC values obtained with the CA-800 device when measuring NIBUT were 5.4 s and 58.6% across the whole sample, 4.2 s and 48.8% for the asymptomatic group and 7.1 s and 68.4% for the symptomatic group. When using the subjective method (EasyTear®), the respective repeatability and ICC values were 7.3 s and 32.7% for the whole sample, 6.5 s and 30.4% for the asymptomatic group and 8.6 s and 35.9% for the symptomatic group. The CA-800 device provided significantly (p < 0.001) shorter NIBUT values compared with EasyTear® for the whole sample (3.3 [2.9] vs. 8.1 [3.4] s), the asymptomatic (3.3 [3.0] vs. 7.7 [3.6] s) and the symptomatic (3.8 [2.9] vs. 8.6 [3.0] s) groups. CONCLUSION: Objective (CA-800) NIBUT assessment provides more reliable measurements than the conventional subjective technique using the EasyTear® device. However, CL practitioners should also be aware that the objective method indicates shorter NIBUT values. Symptomatic CL wearers may also need a higher number of NIBUT measurements to obtain reliable estimations.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Humanos , Masculino , Feminino , Adulto , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Transversais , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Lágrimas
3.
Eye Contact Lens ; 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39024060

RESUMO

OBJECTIVES: To evaluate the reliability and agreement of tear meniscus height (TMH) measurements performed with a corneal analyzer and optical coherence tomography (OCT) technology in contact lens (CL) wearers and its correlation with contact lens discomfort symptoms. METHODS: Asymptomatic and symptomatic CL wearers classified through the Contact Lens Dry Eye Questionnaire-8 were evaluated with the Corneal Analyzer (Topcon CA-800) and OCT technology (Topcon 3D OCT-2000). The repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between devices was calculated using the Bland-Altman method. The relationship between TMH measurements and the Contact Lens Dry Eye Questionnaire-8 and Contact Lens Discomfort Index scores was assessed through the Spearman correlation coefficient. RESULTS: Seventy-nine asymptomatic and 42 symptomatic CL wearers aged 34.24±12.50 years were enrolled. The repeatability values obtained for the CA-800 were 0.07 mm in all cases, and the ICC was 0.93 for the whole sample. The CA-800 provided significantly (P<0.01) higher TMH values than the OCT for the whole sample (0.22±0.08 vs. 0.17±0.06 mm). A weak indirect correlation (ρ=-0.22) between the OCT TMH measurement and Contact Lens Discomfort Index scores was found (P≤0.04). CONCLUSION: The CA-800 provides reliable TMH measurements during CL wear; however, they might not be interchangeable with OCT ones. Tear meniscus height measurements might be useful as a complementary sign to detect CL discomfort, but it cannot be used alone as a diagnostic tool.

4.
Eye Contact Lens ; 50(1): 29-34, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38124284

RESUMO

OBJECTIVE: The purpose of this study was to assess the visual performance and monochromatic higher-order aberrations (HOAs) obtained while wearing a MiSight dual-focus (DF) contact lenses (CL) in comparison with a single-vision contact lens (SVCL). METHODS: A randomized, double-masked, cross-over study was performed. Participants were fitted with a DFCL and a SVCL composed of the same material (omafilcon A) and parameters. Logarithm of the Minimum Angle of Resolution high-contrast (100%) and low-contrast (10%) visual acuity (VA) and contrast sensitivity (CS) for 3, 6, 12, and 18 cycles per degree were measured. Higher-order aberrations were also evaluated using a Hartmann-Shack aberrometer with the CLs on. RESULTS: Twenty-four subjects (21 females and 3 males) with a mean age of 21.9±1.9 years (range: 18-27) were included. Low-contrast VA was significantly lower with the DFCL regarding the SVCL design (0.39±0.23 vs 0.25±0.18, P=0.002). However, there were no differences in high-contrast VA between both CLs (-0.03±0.10 vs -0.09±0.14, P=0.187). Contrast sensitivity was lower with the DFCL under all spatial frequencies (P≤0.048). Second-, third-, fourth-, and fifth-order aberrations were significantly (P<0.001) higher for the DFCL. There were also significant differences between DFCL and SVCL in defocus (0.87±0.28 vs 0.16±0.35, P<0.001), oblique trefoil (-0.16±0.27 vs -0.01±0.08, P=0.005), vertical coma (0.13±0.17 vs 0.00±0.08, P=0.002), and spherical aberration (0.09±0.11 vs -0.02±0.05, P=0.002). CONCLUSION: Visual performance for detecting low-contrast targets is reduced when wearing MiSight DFCL compared with a SVCL with the same material. The main reason might be the induction of second-order and HOAs by the DFCL design.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Sensibilidades de Contraste , Estudos Cross-Over , Transtornos da Visão , Acuidade Visual , Adolescente
5.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 2853-2861, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37115266

RESUMO

PURPOSE: To assess the relationship between anterior chamber depth (ACD) and lens thickness (LT), as well as its three main components (anterior and posterior cortex and nucleus thickness), in cataractous and non-cataractous eyes, depending on the axial length (AxL). METHODS: Anterior and posterior cortex and nucleus thickness of the crystalline lens, ACD, and AxL were measured using optical low-coherence reflectometry in cataractous and non-cataractous eyes. They were also classified into hyperopia, emmetropia, myopia, and high myopia, depending on AxL; thus, eight subgroups were created. A minimum sample size of 44 eyes (of 44 patients) for each group was recruited. Linear models were fitted for the whole sample and each AxL subgroup to assess if there were differences in the relationships between the crystalline lens variables and ACD, including age as a covariate. RESULTS: Three hundred seventy cataract patients (237 females, 133 males) and 250 non-cataract controls (180 females, 70 males), aged 70.5 ± 9.4 and 41.9 ± 15.5 years, respectively, were recruited. The mean AxL, ACD, and LT for the cataractous and non-cataractous eyes were 23.90 ± 2.05, 24.11 ± 2.11, 2.64 ± 0.45, and 2.91 ± 0.49, 4.51 ± 0.38, 3.93 ± 0.44 mm, respectively. The inverse relationship of LT, anterior and posterior cortex, and nucleus thickness with ACD was not significantly (p ≥ 0.26) different between cataractous and non-cataractous eyes. Further subclassification of the sample depending on AxL showed that the inverse relationship between the posterior cortex and ACD was no longer significant (p > 0.05) for any non-cataractous AxL group. LT, anterior and posterior cortex, and nucleus thickness was not significantly (p ≥ 0.43) different between cataractous and non-cataractous eyes for the whole sample, and all AxL groups after adjusting for age. CONCLUSIONS: The presence of cataracts does not modify the inverse relationship of the LT, anterior and posterior cortex, and nucleus with ACD. And this relationship does not seem to depend importantly on AxL. Besides, the possible differences in LT, anterior and posterior cortex, and nucleus between cataractous and non-cataractous eyes may not be caused by lens opacification, but possibly by the progressive lens growth due to aging.


Assuntos
Catarata , Cristalino , Miopia , Masculino , Feminino , Humanos , Catarata/diagnóstico , Envelhecimento , Câmara Anterior , Biometria
6.
Int Ophthalmol ; 43(5): 1501-1510, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36260197

RESUMO

PURPOSE: To assess whether the postoperative outcomes of the implantation of an EVO + implantable collamer lens (ICL) in one eye can be used as a predictor of the vault of the fellow eye, and to evaluate the vault changes of the implantation in both eyes during the postoperative period. METHODS: A prospective study including 40 eyes of 20 patients with a bilateral EVO + ICL implantation was performed. Subjects were evaluated before the surgery and 1 day, 1 week and 1, 3 and 6 months postoperatively. Central vault was assessed using spectral-domain optical coherence tomography. The inter-eye and follow-up analyses were performed using lineal models and the Bland-Altman method. RESULTS: The vault of the first implanted eye at the 1-day visit highly predicts the vault of the second eye (R2 = .87; P < .001); the mean inter-eye difference was - 0.95 µm, and the superior and inferior limits of agreement were -50.27 µm and 148.37 µm, respectively. This relationship was maintained during the medium-term follow-up, not finding differences in the slopes among visits (P ≥ .09). A progressive decrease of vault was found during the follow-up (P < .001). Larger vault change 6 months after the surgery was associated with higher vault 1 day after the ICL implantation (R2 = .19;P = .005). CONCLUSION: One-day postoperative vault in the first eye can help to predict the optimal ICL sizing in the second eye. Vault tends to decrease during the first 6 months after EVO + ICL implantation. Eyes with higher initial vaults will also show larger reductions during the medium-term follow-up.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Miopia/diagnóstico , Miopia/cirurgia , Período Pós-Operatório , Estudos Retrospectivos
7.
Int Ophthalmol ; 43(12): 4711-4718, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37697080

RESUMO

PURPOSE: To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. METHODS: Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. RESULTS: Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). CONCLUSIONS: The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.


Assuntos
Implante de Lente Intraocular , Transtornos da Pigmentação , Masculino , Feminino , Humanos , Adulto , Reprodutibilidade dos Testes , Implante de Lente Intraocular/métodos , Câmara Anterior , Malha Trabecular/cirurgia , Iris/cirurgia , Pigmentação , Gonioscopia
8.
Ophthalmic Physiol Opt ; 39(5): 328-336, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31463969

RESUMO

PURPOSE: To investigate the effect of soft contact lens (CL) wear on the morphology of the epithelial-lamina propria junction as well as the possible association with symptoms of discomfort. METHODS: Ninety-two subjects were recruited, including 60 soft CL wearers, 16 previous wearers, and 16 non-wearers. Additionally, subjects were classified as symptomatic or asymptomatic using the Contact Lens Dry Eye Questionnaire 8 for the CL wearers (a score ≥ 12 was considered symptomatic) and the Dry Eye Questionnaire 5 for the previous wearers and non-wearers (a score ≥ 5 was considered symptomatic). In vivo confocal microscopy of the tarsal conjunctiva was performed on a single occasion. Papillae density, shortest diameter, longest diameter, area, circularity, lumen/wall brightness ratio, irregularity, reflectivity, inhomogeneous appearance of wall and inhomogeneous appearance of rete ridges were evaluated. Effects of CL wear, symptoms and their interaction were analysed using two-way analysis of variance. Correlations were investigated using Spearman's coefficient. Data are presented as mean (standard deviation) or median [interquartile range]. RESULTS: Contact lens wearers, compared to previous wearers and non-wearers, showed higher circularity [0.65 (0.08) vs 0.59 (0.10) vs 0.57 (0.11), p = 0.003]. Subjects with symptoms, compared to asymptomatic participants, showed higher circularity [0.64 (0.08) vs 0.61 (0.10), p < 0.001] and lower irregularity (1.0 [0.7-2.0] vs 1.3 [1.0-2.3], p = 0.009). For previous wearers, those with symptoms showed greater density (135.4 [107.3-183.3] vs 87.5 [85.4-116.7], p = 0.013) and circularity [0.64 (0.07) vs 0.54 (0.10), p = 0.016]. For non-wearers, those with symptoms showed higher circularity [0.65 (0.08) vs 0.50 (0.08), p < 0.001]. DEQ-5 correlated with circularity (ρ = 0.55, p = 0.001). CONCLUSIONS: Soft CL wear modifies papillae of the epithelial-lamina propria junction into a more rounded shape; however, CL cessation appears to resolve this alteration. Additionally, a more rounded papillae shape is associated with ocular symptoms in subjects not actively wearing CLs.


Assuntos
Túnica Conjuntiva/patologia , Lentes de Contato Hidrofílicas/efeitos adversos , Síndromes do Olho Seco/diagnóstico , Adulto , Análise de Variância , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Microscopia Confocal , Adulto Jovem
9.
Eye Contact Lens ; 44 Suppl 2: S227-S232, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29461299

RESUMO

OBJECTIVES: To determine the reliability of wet and modified dry blotting techniques used in the gravimetric method to assess contact lens (CL) water content (WC), the accuracy of both techniques in comparison with the nominal WC, and also their agreement. METHODS: We evaluated hydrated and dry CL mass values and WC using the gravimetric method in 440 daily disposable CLs. Samples assessed corresponded to Dailies Total 1, Dailies AquaComfort Plus, 1-Day Acuvue TruEye, and Biotrue ONEday. Back vertex power ranged from +3.00 diopters (D) to -6.00 D. Within-subject coefficient of variation (CVw) and intraclass correlation coefficients were calculated. Bland-Altman analysis was also performed. RESULTS: The modified dry blotting technique yielded significantly (P≤0.0001) higher hydrated CL mass values. The wet blotting technique provided significantly (P≤0.04) better consistency than the modified dry one. Values of CVw for wet and modified dry blotting techniques ranged from 1.2% to 2.1% and from 3.7% to 5.4%, respectively. As for dry CL mass values, CVw values were not significantly different (P≥0.05) between wet (range: 1.1%-1.9%) and dry (range: 1.0%-5.1%) blotting techniques, except for Dailies AquaComfort Plus (P=0.03). Bland-Altman analysis showed poor agreement between the techniques. The wet blotting technique yielded WC values close (around 1%) to nominal ones, in contrast to modified dry blotting technique (≥2.5%). CONCLUSIONS: The wet blotting technique is not only more reliable than the modified dry one when obtaining hydrated CL mass but also provides more accurate nominal WC measurements. Agreement between the techniques was poor.


Assuntos
Lentes de Contato Hidrofílicas , Teste de Materiais/métodos , Água/análise , Equipamentos Descartáveis , Humanos , Reprodutibilidade dos Testes
10.
Ophthalmic Physiol Opt ; 37(1): 60-70, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28030882

RESUMO

PURPOSE: To assess the influence of different indoor environments simulated in an environmental chamber on soft contact lens (CL) wearers. METHODS: Fifty-four CL wearers were grouped based on their symptoms while wearing their CLs. Subjects were fitted with two different CL types, conventional hydrogel (Omafilcon A) and silicone hydrogel (comfilcon A), and exposed to two controlled indoor environmental conditions, standard [50% relative humidity (RH), 23°C, 930 mb of atmospheric pressure] and adverse (in-flight air cabin environment: 5% RH, localised air flow, 23°C, 750 mb atmospheric pressure), for 90 min in an environmental chamber, making a total of four visits. Symptoms, tear osmolarity, pre-lens tear breakup time (PLBUT), phenol red thread test, visual acuity, bulbar and limbal hyperaemia, corneal and limbal staining, and CL dehydration were assessed using repeated measures analysis of variance. A linear mixed model was used to analyse the effect of environment, CL type, discomfort-based grouping, and time on blink rate. RESULTS: Environment was found to significantly (p ≤ 0.018) affect limbal and bulbar hyperaemia, PLBUT, tear osmolarity, and CL dehydration. Likewise, CL type significantly (p ≤ 0.04) affected nasal and total corneal staining, limbal conjunctival staining, CL dehydration, comfort, and blurred vision. The environment, CL type, and time had significant effects (p ≤ 0.0001) on the blink rate. CONCLUSIONS: Ocular surface integrity and blink rate in CL wearers depend on the environment CL users are exposed to, as well as on the soft CL type that they are wearing. Tight control of environmental conditions can contribute to a better understanding of CL-related discomfort.


Assuntos
Piscadela/fisiologia , Túnica Conjuntiva/diagnóstico por imagem , Lentes de Contato Hidrofílicas , Córnea/diagnóstico por imagem , Exposição Ambiental , Satisfação do Paciente , Acuidade Visual , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Inquéritos e Questionários , Adulto Jovem
11.
Eye Contact Lens ; 43(1): 57-63, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26783978

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of a new artificial tear containing 0.2% hyaluronic acid, as compared with 0.9% saline solution, in mild dry eye patients after 1-month use in a crossover study design with washout periods. METHODS: Overall, 16 mild dry eye patients were included. After a week of washout, every patient used the experimental product (Visaid 0.2%) and the control product (0.9% saline solution), each for a month (3-8 drops daily). Both products were preservative free. The percentage change for the following variables were calculated and analyzed: Ocular Surface Disease Index (OSDI) questionnaire, visual acuity, intraocular pressure, ophthalmoscopy evaluation, biomicroscopy findings, fluorescein corneal staining and lissamine green conjunctival staining, tear breakup time, contrast sensitivity, Schirmer's test, and subject satisfaction. RESULTS: Patients reported an improvement (a significant decrease of -19.5%±27.5%) in OSDI scores after using Visaid 0.2% and a worsening (a significant increase of 19.2%±32.4%) after using 0.9% saline solution; the difference was significant (P=0.0087, Student's t test). Significant changes (P≤0.04, Wilcoxon's test) were found comparing Visaid 0.2% with saline solution for bulbar hyperemia (-39.1%±50.8% vs. 7.8%±12.0%, respectively), corneal staining (-26.0%±53.0% vs. 36.5%±73.3%), conjunctival staining (-54.7%±53.4% vs. -7.8%±47.2%), and subjective satisfaction (26.8%±28.5% vs. -13.3%±22.5%). There were no significant differences in the safety parameters for either solution. CONCLUSION: This clinical trial demonstrates the safety of Visaid 0.2% and its clear benefit over 0.9% saline solution.


Assuntos
Síndromes do Olho Seco/tratamento farmacológico , Ácido Hialurônico/uso terapêutico , Lubrificantes Oftálmicos/uso terapêutico , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Método Duplo-Cego , Síndromes do Olho Seco/fisiopatologia , Feminino , Humanos , Ácido Hialurônico/efeitos adversos , Pressão Intraocular/fisiologia , Lubrificantes Oftálmicos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Estudos Prospectivos , Cloreto de Sódio , Inquéritos e Questionários , Resultado do Tratamento , Acuidade Visual/fisiologia
12.
Eye Contact Lens ; 43(6): 383-388, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27243353

RESUMO

PURPOSE: To evaluate the safety and efficacy of a new 0.3% hyaluronic acid artificial tear compared with 0.9% saline solution (0.9% NaCl) in moderate-to-severe dry eye patients after 1 month's use. METHODS: A total of 16 patients with moderate-to-severe dry eye were included in this crossover study. After a 1-week washout period, patients used the experimental (Visaid 0.3%) or control solution (0.9% NaCl), selected randomly, applying three to eight drops daily for a month. After another washout period, patients used the other solution in the same way. Percentage of change (ΔY) was calculated and analyzed for (1) safety variables: visual acuity, intraocular pressure, and ophthalmoscopy evaluation; (2) efficacy variable: Ocular Surface Disease Index (OSDI) questionnaire; and (3) secondary variables: biomicroscopy findings, fluorescein corneal staining, lissamine green conjunctival staining, tear breakup time (TBUT), contrast sensitivity, Schirmer test, and subject satisfaction. RESULTS: There were no significant differences in the safety parameters for either solution. After using Visaid 0.3%, patients showed significant improvements in OSDI score (ΔY: -9.66%±10.90), tarsal hyperemia (ΔY: -16.67%±27.89), corneal staining extension (ΔY: -34.90%±42.41), TBUT (ΔY: 13.98%±26.19), and subjective satisfaction (ΔY: 38.06%±47.06). When using 0.9% NaCl, Schirmer test results were significantly worse (ΔY: -11.47%±19.27). A significant difference between the 2 solutions was found in TBUT (ΔY: 13.98%±26.19 vs. 10.15%±42.34, respectively; P=0.0214). CONCLUSION: Visaid 0.3% is a safe product with some benefits over 0.9% NaCl in reducing ocular symptoms and improving some ocular signs in patients with moderate-to-severe dry eye.


Assuntos
Síndromes do Olho Seco/tratamento farmacológico , Ácido Hialurônico/uso terapêutico , Lubrificantes Oftálmicos/uso terapêutico , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Córnea/metabolismo , Estudos Cross-Over , Método Duplo-Cego , Síndromes do Olho Seco/fisiopatologia , Feminino , Humanos , Ácido Hialurônico/efeitos adversos , Pressão Intraocular/fisiologia , Lubrificantes Oftálmicos/efeitos adversos , Lubrificantes Oftálmicos/química , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Acuidade Visual/fisiologia
13.
Ophthalmology ; 123(1): 141-53, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26520171

RESUMO

PURPOSE: To assess the efficacy of topical 0.1% fluorometholone in dry eye disease (DED) patients for ameliorating the worsening of the ocular surface when exposed to adverse environments. DESIGN: Single-center, double-masked, randomized, vehicle-controlled clinical trial. PARTICIPANTS: Forty-one patients showing moderate to severe DED. METHODS: Patients randomly received 1 drop 4 times daily of either topical 0.1% fluorometholone (FML group) or topical polyvinyl alcohol (PA group) for 22 days. Corneal and conjunctival staining, conjunctival hyperemia, tear film breakup time (TBUT), tear osmolarity, and the Symptom Assessment in Dry Eye (SANDE) questionnaire scores were determined at baseline. Variables were reassessed on day 21 before and after undergoing a 2-hour controlled adverse environment exposure and again on day 22. MAIN OUTCOMES MEASURES: Percentage of patients showing an increase 1 point or more in corneal staining and a reduction of 2 points or more (0-10 scale) in SANDE score, after the controlled adverse environment exposure and 24 hours later. RESULTS: After 21 days of treatment, the FML group showed greater improvements in corneal and conjunctival staining, hyperemia, and TBUT than the PA group (P≤0.03). After the adverse exposure, the percentage of patients having a 1-grade or more increase in corneal staining was significantly (P = 0.03) higher in the PA group (63.1% vs. 23.8%, respectively). Additionally, the FML group showed no significant changes in corneal staining (mean, 0.86; 95% confidence interval [CI], 0.47-1.25; vs. mean, 1.05; 95% CI, 0.59-1.51, for visit 2 and 3, respectively), conjunctival staining (mean, 0.95; 95% CI, 0.54-1.37 vs. mean, 1.19; 95% CI, 0.75-1.63), and hyperemia (mean, 0.71; 95% CI, 0.41-1.02 vs. 1.14; 95% CI, 0.71-1.58) after the exposure, whereas for the PA group, there was significant worsening (P≤0.009) in these variables (corneal staining: mean, 1.95; 95% CI, 1.57-2.33 vs. mean, 2.58; 95% CI, 2.17-2.98; conjunctival staining: mean, 1.68; 95% CI, 1.29-2.08 vs. mean, 2.47; 95% CI, 2.07-2.88; hyperemia: mean, 1.95; 95% CI, 1.63-2.26 vs. mean, 2.84; 95% CI, 2.62-3.07). CONCLUSIONS: Three-week topical 0.1% fluorometholone therapy is effective not only in reducing ocular surface signs in DED patients, but also especially in preventing exacerbation caused by exposure to a desiccating stress.


Assuntos
Túnica Conjuntiva/efeitos dos fármacos , Córnea/efeitos dos fármacos , Desidratação/complicações , Síndromes do Olho Seco/tratamento farmacológico , Fluormetolona/administração & dosagem , Administração Tópica , Túnica Conjuntiva/patologia , Córnea/patologia , Desidratação/patologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/patologia , Feminino , Glucocorticoides/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
14.
Optom Vis Sci ; 93(8): 892-900, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26636403

RESUMO

PURPOSE: The aim of this study was to analyze whether symptoms of discomfort in hydrogel contact lens (HCL) wearers were associated with changes in corneal sensitivity or levels of tear inflammatory mediators. METHODS: Sixty-six subjects were included: 47 HCL wearers, further divided into 24 symptomatic and 23 asymptomatic wearers by the Contact Lens Dry Eye Questionnaire short form and 19 non-contact lens wearers. At least 24 h after HCL removal, we obtained scores from the Ocular Surface Disease Index and mechanical, hot, and cold corneal thresholds using a Belmonte esthesiometer. We collected 4 µl of tears with a capillary micropipette and measured levels of 12 inflammatory markers using a bead-based array: epidermal growth factor, fractalkine, interleukin-10 (IL-10), IL-1ß, IL-1 receptor antagonist, IL-2, IL-4, IL-6, IL-8, monocyte chemoattractant protein 1, tumor necrosis factor-α, and matrix metalloproteinase 9. RESULTS: There were no significant differences between groups in corneal sensitivity thresholds and levels of tear molecules. The following significant correlations were found in the total sample pooled: Ocular Surface Disease Index correlated with mechanical threshold (p < 0.01; rho = -0.324) and epidermal growth factor (p < 0.01, rho = -0.330), and mechanical threshold correlated with heat threshold (p < 0.01, rho = -0.321). CONCLUSIONS: Twenty-four hours after HCL removal, symptoms of discomfort in HCL wearers are not related to changes in corneal sensitivity or tear inflammatory mediator levels. This might indicate either that HCL wear has no effect on these parameters or that ocular surfaces recover from HCL-caused effects during the first hours after HCL removal. However, there were correlations for associations between symptoms, corneal sensitivity, and some molecules in tears.


Assuntos
Lentes de Contato/efeitos adversos , Córnea/inervação , Citocinas/metabolismo , Inflamação/metabolismo , Satisfação do Paciente , Sensação/fisiologia , Lágrimas/metabolismo , Adolescente , Adulto , Biomarcadores/metabolismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
15.
Ophthalmol Ther ; 13(3): 819-830, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38273047

RESUMO

INTRODUCTION: Characterizing lens thickness (LT) in patients with cataracts is important for better understanding the lens aging process and for designing new intraocular lens power formulas. This study aimed to analyze the influence of common senile cataract formation on the LT, anterior (ACS) and posterior (PCS) cortex space, and nuclear thickness (NT), controlling for sex, age, and axial length. METHODS: A cross-sectional study was performed. A consecutive sample of 603 volunteers (403 women, 200 men) aged 59.1 ± 18.8 years was recruited. The standardized Lens Opacification Classification System (LOCS)-III was used to classify eyes (randomly selected) into cataractous and non-cataractous groups. Also, they were classified according to the cataract location (presence or absence of cortical, nuclear, or posterior subcapsular cataract). Optical biometry was performed to measure LT, ACS, NT, and PCS. Propensity score was used to match participants one-to-one for sex, age, and axial length. Groups were compared using the Student's t test or Yuen's test. RESULTS: The four classifications divided unmatched eyes into: 361 cataractous lenses and 242 non-cataractous, 226 cortical and 377 non-cortical cataractous, 313 nuclear and 290 non-nuclear cataractous and 242 subcapsular and 361 non-subcapsular cataractous. Before matching, cataractous eyes showed significantly higher LT (4.52 ± 0.39 vs. 3.94 ± 0.46 mm, p < 0.001), ACS (0.75 ± 0.20 vs. 0.58 ± 0.23 mm, p < 0.001), NT (3.34 ± 0.23 vs. 3.18 ± 0.25 mm, p < 0.001) and PCS (0.42 ± 0.19 vs. 0.37 ± 0.19 mm, p = 0.003). Matched lens, cortical, nuclear, and subcapsular cataract samples comprised 146, 258, 182, and 226 eyes, respectively. After matching, no significant differences were observed in LT (4.34 ± 0.37 vs. 4.33 ± 0.36 mm, p = 0.94), ACS (0.72 ± 0.20 vs. 0.76 ± 0.19 mm, p = 0.08), NT (3.31 ± 0.22 vs. 3.30 ± 0.23 mm, p = 0.24) and PCS (0.42 ± 0.19 vs. 0.43 ± 0.16 mm, p = 0.79). CONCLUSIONS: The presence of senile cortical, nuclear, and posterior subcapsular cataract have no effect on LT, ACS, NT, and PCS. Confounding factors should be controlled for when measuring LT and its main components.

16.
Cont Lens Anterior Eye ; 47(1): 102096, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38097423

RESUMO

PURPOSE: This study aimed to assess the subjective and objective differences among the steps of the contact lens discomfort (CLD) progression classification established by the Tear Film & Ocular Surface Society (TFOS) using questionnaires and clinical signs, and to propose a simplified classification. METHODS: Contact lens (CL) wearers were evaluated in a single visit. The Contact Lens Dry Eye Questionnaire (CLDEQ)-8, the Contact Lens Discomfort Index, and Visual Analog Scales for discomfort and dryness were administered. The non-invasive break-up time, the tear film lipid layer thickness, conjunctival hyperaemia and papillae, lid-parallel conjunctival folds, the fluorescein tear film break-up time, corneal and conjunctival staining, lid wiper epitheliopathy, and the Schirmer test were assessed. Sign and symptom scores were compared among TFOS CLD progression steps using analysis of variance or the Kruskal-Wallis H test. Steps 1 and 2 (reduced comfort), and steps 3 and 4 (reduced wearing time) of the TFOS classification were combined to obtain a simplified classification, and the same comparison was performed. A p-value ≤ 0.05 was considered statistically significant. RESULTS: One hundred-fifty CL wearers (97 women and 53 men) aged 34.4 ± 12.6 years were included. In the TFOS classification, there were significant differences between step 0 (no CLD) and the rest of the severity steps for the scores obtained in all questionnaires (p ≤ 0.015). All steps were differentiated (p ≤ 0.032) based on the simplified classification for all questionnaires, except steps 1 and 2 for the CLDEQ-8 and dryness VAS (p = 0.089 and p = 0.051, respectively). There were no differences (all p ≥ 0.06) between the sign scores among the steps of either classification. CONCLUSION: CLD management is encouraged from its first appearance. Simplifying the phases of CLD severity may allow a more accurate classification and a better awareness of the problem by clinicians and CL wearers by using more straightforward simple messages.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Masculino , Humanos , Feminino , Lentes de Contato Hidrofílicas/efeitos adversos , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Túnica Conjuntiva , Córnea , Lágrimas
17.
Ocul Immunol Inflamm ; : 1-9, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38889385

RESUMO

PURPOSE: To analyze changes in tear levels of inflammatory mediators in symptomatic contact lens (CL) wearers after refitting with daily disposable CLs and to identify potential biomarkers of success in CL discomfort (CLD) management. METHODS: Symptomatic CL wearers (CLDEQ-8 ≥ 12) were refitted (V1) with daily disposable CLs (Delefilcon A). After one month (V2), participants were classified into the post-fitting non-symptomatic (CLDEQ <12) and symptomatic (CLDEQ ≥12) groups. At each visit, the participants were clinically evaluated, tears were collected, and 20 inflammatory mediators and substance P (SP) were measured using multiplex immunobead analysis and ELISA, respectively. The detection rates and concentrations were compared between visits and groups, and logistic regression models were performed. RESULTS: Forty-three subjects (32 women/11 men; mean age: 23.2 ± 4.9 years) were enrolled. The IL-1ß and IL-9 detection rates were higher at V2 (p ≤ 0.044). The detection rates of IL-1ß, IL-9, MIP-1α/CCL3, and MMP-9 at V1 (p ≤ 0.045) and IL-17A at V2 (p ≤ 0.014) were higher in the post-fitting symptomatic group. The tear IL-9 concentration was increased at V2 (p = 0.018). The tear concentrations of fractalkine/CX3CL1, IL-2, IL-6, IL-10, MCP-3/CCL7, MIP-1ß, NGF, RANTES/CCL5, and TNF-α were higher in the post-fitting symptomatic group (p ≤ 0.044). Additionally, levels of fractalkine/CX3CL1, IL-2, IL-6, IL-10, RANTES/CCL5, and TNF-α at V1 were significantly associated with the post-fitting grouping (p ≤ 0.044). CONCLUSIONS: Low tear concentrations of specific inflammatory mediators may be used as a predictive biomarker of success for refitting symptomatic CL wearers with daily disposable CLs. However, complementary treatments might be required for symptomatic CL wearers with higher levels of these inflammatory molecules.

18.
Orphanet J Rare Dis ; 19(1): 234, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872169

RESUMO

BACKGROUND: The low prevalence of rare diseases poses a significant challenge in advancing their understanding. This study aims to delineate the clinical and genetic characteristics of patients with rare eye diseases (RED) enrolled in the Spanish Rare Diseases Patient Registry. METHODS: A total of 864 patients from the registry database were included. Diseases were categorized into inherited retinal dystrophies (n=688); anterior segment diseases (n=48); congenital malformations (n=27); and syndromic diseases with ocular involvement including muscular (n=46), neurological (n=34), or metabolic (n=13); inflammatory diseases (n=4); and tumors (n=4). Data on visual acuity (VA) and/or visual field (VF), symptoms and signs, concurrent diseases in syndromic cases, age of onset and at diagnosis, affected genes, disability rating, inability to work and dependency grade recognition were collected. RESULTS: A mean diagnostic delay of 7 years from symptom onset was observed. Commonly reported symptoms included photophobia, night blindness, and progressive vision loss (≥57% of patients). Cataract was the most prevalent secondary disease (46%), with pseudophakia being the most common ocular surgery (26%). Hearing loss and cardiovascular diseases were the most prevalent concurrent systemic diseases (≥13%). Certificates of disability, incapacity for work, and dependency were held by 87%, 42%, and 19% of patients, respectively. Among the 719 patients with available VA data, 193 (27%) were blind, and 188 (26%) had moderate to severe visual impairment. Over half of the patients (54%) exhibited VF defects, and 216 (25%) had concentric contraction ≤5° or abolished VF. Most had genetic diseases with autosomal recessive (55%), autosomal dominant (30%), X-linked (9%), and mitochondrial (6%) patterns. One patient had mutations in both recessive USH2A and dominant RHO genes simultaneously. Of the 656 patients (75.7%) who underwent genetic testing, only 461 (70.3%) received a positive result (pathogenic or likely pathogenic mutations explaining the phenotype). We found 62 new gene variants related to RED not previously reported in databases of genetic variants related to specific phenotypes. CONCLUSIONS: This study delineates the clinical and genotypic profiles of RED in Spain. Genetic diseases, particularly retinal disorders, predominate, but a significant proportion of affected patients remain genetically undiagnosed, hindering potential gene therapy endeavors. Despite notable improvements in reducing diagnosis delays, it is still remarkable. RED frequently lead to disability and blindness among young populations.


Assuntos
Oftalmopatias , Doenças Raras , Sistema de Registros , Humanos , Masculino , Feminino , Oftalmopatias/genética , Oftalmopatias/epidemiologia , Espanha/epidemiologia , Adulto , Doenças Raras/genética , Pessoa de Meia-Idade , Adolescente , Criança , Adulto Jovem , Pré-Escolar , Idoso , Lactente , Acuidade Visual/fisiologia , Distrofias Retinianas/genética , Distrofias Retinianas/epidemiologia , Distrofias Retinianas/diagnóstico
19.
Ocul Surf ; 31: 31-42, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38128761

RESUMO

PURPOSE: This study aimed to analyze the differences in the expression of pain-related genes in conjunctival epithelial cells among symptomatic contact lens (CL) wearers (SCLWs), asymptomatic CL wearers (ACLWs), and non-CL wearers (non-CLWs). METHODS: For this study, 60 participants (20 non-CLWs, 40 CLWs) were enrolled. The CLW group comprised 20 ACLWs and 20 SCLWs according to the Contact Lens Dry Eye Questionnaire short form©. Conjunctival cells were collected using impression cytology, and RNA was isolated and used to determine the expression levels of 85 human genes involved in neuropathic and inflammatory pain. The effects of CL wear and discomfort were evaluated using mixed-effects ANOVA with partially nested fixed-effects model. Gene set enrichment analysis was performed to assign biological meaning to sets of differentially expressed genes. RESULTS: Six genes (CD200, EDN1, GRIN1, PTGS1, P2RX7, and TNF) were significantly upregulated in CLWs compared to non-CLWs. Eleven genes (ADORA1, BDKRB1, CACNA1B, DBH, GRIN1, GRM1, HTR1A, PDYN, PTGS1, P2RX3, and TNF) were downregulated in SCLWs compared to ACLWs. These genes were mainly related to pain, synaptic transmission and signaling, ion transport, calcium transport and concentration, and cell-cell signaling. CONCLUSIONS: CL wear modified the expression of pain- and inflammation-related genes in conjunctival epithelial cells. These changes may be in part, along with other mechanisms, responsible for CL discomfort in SCLWs.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Humanos , Túnica Conjuntiva/metabolismo , Células Epiteliais/metabolismo , Síndromes do Olho Seco/metabolismo , Dor , Expressão Gênica
20.
J Cataract Refract Surg ; 49(1): 21-28, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36573762

RESUMO

PURPOSE: To assess the repeatability and agreement of Cartesian coordinates and the length of apparent chord mu and pupil diameter measurements during static (Galilei G4) and dynamic (Topolyzer Vario) evaluations. SETTING: IOBA-Eye Institute, Valladolid, Spain. DESIGN: Case series. METHODS: 3 consecutive measurements per scenario (Galilei G4 and Topolyzer Vario under low mesopic and photopic conditions) were performed by the same clinician. The intrasession repeatability was assessed using the within-subject SD (Sw), the precision, the coefficient of variation, and the intraclass correlation coefficient (ICC). The agreement was analyzed using repeated-measures analysis of variance and the Bland-Altman method. RESULTS: Thirty-seven healthy participants were recruited. The Sw values for chord mu parameters and pupil diameter ranged from 0.01 to 0.03 and 0.08 to 0.21, respectively. The ICC was ≥0.89 for all parameters. Galilei G4 and Topolyzer Vario under low mesopic and photopic conditions provided significantly different measures of apparent chord mu length (0.23 ± 0.11 mm, 0.30 ± 0.10 mm, and 0.25 ± 0.11 mm, respectively, P ≤ .02), X-coordinate (-0.18 ± 0.12 mm, -0.27 ± 0.11 mm, and -0.21 ± 0.12 mm, respectively, P < .001), and pupil diameter (3.38 ± 0.50 mm, 6.29 ± 0.60 mm, and 3.04 ± 0.41 mm, respectively, P < .001). Y-coordinate values obtained by Galilei G4 and Topolyzer Vario under low mesopic conditions were significantly different (0.06 ± 0.13 mm vs 0.03 ± 0.11 mm, respectively, P = .02), in contrast to Galilei G4 and Topolyzer Vario under photopic conditions (0.05 ± 0.13 mm, P = .82) and both illumination conditions of Topolyzer Vario (P ≥ .23). CONCLUSIONS: Galilei G4 and Topolyzer Vario provide consistent measurements of apparent chord mu Cartesian coordinates and length, as well as pupil diameter; however, the measurements are not interchangeable. Ophthalmic surgeons should consider these findings when planning customized intraocular lens implantation and refractive surgery procedures.


Assuntos
Visão de Cores , Procedimentos Cirúrgicos Refrativos , Humanos , Reprodutibilidade dos Testes , Voluntários Saudáveis , Iluminação , Pupila
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa