Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Cardiothorac Vasc Anesth ; 38(3): 638-648, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38185565

RESUMO

OBJECTIVES: Left ventricular (LV) diastolic function strongly predicts outcomes after cardiac surgery, but there is no consensus about appropriate intraoperative assessment. Recently, intraoperative diastolic strain-based measurements assessed by transesophageal echocardiography (TEE) have shown a strong correlation with LV relaxation, compliance, and filling, but there are no reports about evaluation through the entire perioperative period. Therefore, the authors describe the intraoperative course of this novel assessment technique in patients who underwent coronary artery bypass grafting, and compare it with conventional echocardiographic measures and common grading algorithms of LV diastolic dysfunction (LVDD). DESIGN: Prospectively obtained data. SETTING: A single university hospital. PARTICIPANTS: Thirty adult patients scheduled for isolated on-pump coronary artery bypass grafting surgery with preoperative preserved left and right ventricular systolic function, without significant heart valve disease and pulmonary hypertension, and an uneventful intraoperative course were included. INTERVENTIONS: Transesophageal echocardiography was performed after induction of anesthesia (T1), after termination of cardiopulmonary bypass (T2), and after sternal closure (T3). Echocardiographic evaluation was performed in stable hemodynamic conditions, in sinus rhythm or atrial pacing, and vasopressor support with norepinephrine ≤0.1 µg/kg/min. MEASUREMENTS AND MAIN RESULTS: Strain-based measurements of peak longitudinal strain rate during isovolumetric relaxation (SR-IVR) and during early (SR-E) and late (SR-A) LV filling were assessed using EchoPAC v204 software (GE Vingmed Ultrasound AS, Norway). Evaluation of conventional echocardiographic parameters included transmitral Doppler measures of early (E) and late (A) LV filling, as well as lateral-tissue Doppler velocity assessed during early (e´) and late (a´) LV filling, tricuspid regurgitation, and left atrial dilatation. Evaluation and grading of LV diastolic function by myocardial strain was feasible in all included patients at all time points of assessment. Using conventional grading algorithms, however, a substantial number of patients could not be sufficiently graded, falling into an indeterminate zone and not reliably estimating LVDD (T1, 40%; T2, 33%; T3, 36%). There was significant impairment of LV diastolic function after bypass, as measured by SR-IVR (T1 v T2, 0.28 s-1 [IQR 0.23; 0.31) v 0.18 s-1 [IQR 0.14; 0.22]; p < 0.001), SR-E (T1 v T2, 0.95 ± 0.34 s-1v 1.28 ± 0.36 s-1; p < 0.001), and E/SR-IVR (T1 v T2, 2.3 ± 1.0 m v 4.5 ± 2.1 m; p < 0.001]. Conventional echocardiographic measures remained unchanged during the same period (E/A T1 v T2, 1.27 [IQR 0.94; 1.59] v 1.21 [IQR 1.03; 1.47] [p = 1] and E/e´ T1 v T2, 7.0 [IQR 5.3; 9.6] v 6.35 [IQR 5.7; 9.9] [p = 0.9]). There were no significant changes in the values of SR-IVR, SR-E, SR-A, E/SR-IVR, E/A, and E/e´ before and after sternal closure (T2 v T3). CONCLUSION: Intraoperative assessment of strain-based measurements of LV diastolic function and strain-based LVDD grading was feasible in this group of selected patients, whereas conventional parameters failed to describe LVDD sufficiently in a substantial number of patients. Diastolic strain-based measurements showed impairment of LV relaxation and compliance after bypass, which was not detected by conventional echocardiographic parameters. Therefore, diastolic myocardial strain analysis might be more sensitive in detecting myocardial diastolic dysfunction by TEE in the perioperative setting, with its dynamic changes of loading conditions, and might provide valuable and additional information on the perioperative changes of LV diastolic function.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Adulto , Humanos , Ponte de Artéria Coronária/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Ecocardiografia , Diástole
2.
Echocardiography ; 40(7): 615-622, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37229579

RESUMO

BACKGROUND: Data on intraoperative three-dimensionally derived right ventricular free-wall strain (3D-RV FWS) is sparse. OBJECTIVES: We sought to evaluate the normal range of intraoperative 3D-RV FWS in patients scheduled for coronary artery bypass graft (CABG) surgery and compared to conventional echocardiographic parameters. Prospective observational study. METHODS: A total of 150 patients with preserved left and right ventricular (RV) function and sinus rhythm, without significant heart valve disease or pulmonary hypertension undergoing isolated on-pump CABG surgery, with an uneventful, complication-free intraoperative course. 3D-RV FWS analysis and conventional echocardiographic assessment of RV function were performed intraoperatively in anesthetized and ventilated patients using transesophageal echocardiography (TEE). TomTec 4D RV-Function 2.0 software for assessment of 3D-RV FWS and three-dimensional right ventricular ejection fraction (3D-RV EF). Philips QLAB 10.8 was used to evaluate tissue velocity of the tricuspid annulus (RV S´), tricuspid annular systolic excursion (TAPSE), and RV fractional area change (FAC). All echocardiographic measurements were performed under stable hemodynamic conditions and predefined fluid management without any vasoactive support or pacing. The prospective observational study was performed in a single university hospital setting. RESULTS: Assessment of 3D-RV FWS was feasible in 95% of patients. No included patient experienced any serious perioperative complication. In our group of patients, median values with interquartile range (IQR) for 3D-RV FWS and 3D-RV EF were -25.2 (IQR -29.9 to -21.8) and 46.3% (IQR 41.0%-50.1%), respectively. RV FAC, RV S´, and TAPSE accounted for 39.7% (IQR 34.5%-44.4%), 14.8 cm/s (IQR 11.8-19.0 cm/s), and 22 mm (IQR 20-25 mm). The normal range (2.5% to 97.5% percentile) for 3D-RV FWS was -37.1 to -12.8. There was no relevant correlation of 3D-RV FWS to postoperative outcome in this group of CABG patients. CONCLUSION: We present distribution values for intraoperative 3D-RV FWS and conventional parameters of RV function assessment in a healthy on-pump CABG patient population without serious perioperative complications. We observed no correlations of these parameters with any of the outcome parameters considered. Therefore, we consider these values to be intraoperative TEE-assessed normal values, which can be expected in on-pump CABG patients.


Assuntos
Disfunção Ventricular Direita , Função Ventricular Direita , Humanos , Valores de Referência , Volume Sistólico , Ponte de Artéria Coronária/efeitos adversos , Ecocardiografia
3.
J Cardiothorac Vasc Anesth ; 37(2): 221-231, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36404229

RESUMO

OBJECTIVES: Noninvasive echocardiographic analysis of left ventricular (LV) myocardial work (MW) enables insights into cardiac mechanics, contractility, and efficacy beyond ejection fraction (EF) and global longitudinal strain (GLS). However, there are limited perioperative data on patients undergoing coronary artery bypass graft (CABG) surgery. The authors aimed to describe the feasibility and the intraoperative course of this novel assessment tool of ventricular function in these patients, and compare it to conventional 2-dimensional (2D) and 3-dimensional (3D) echocardiographic parameters and strain analysis. DESIGN: A prospective observational study. SETTING: At a single university hospital. PARTICIPANTS: Twenty-five patients with preoperative preserved LV and right ventricular function, sinus rhythm, without significant heart valve disease or pulmonary hypertension, and an uncomplicated intraoperative course scheduled for isolated on-pump CABG surgery. INTERVENTIONS: Transesophageal echocardiography (TEE) was performed intraoperatively after the induction of anesthesia (T1), after termination of cardiopulmonary bypass (T2), and after sternal closure (T3). All measurements were performed under stable hemodynamic conditions, in sinus rhythm or atrial pacing, and vasopressor support with norepinephrine ≤ 0.1 µg/kg/min. MEASUREMENTS AND MAIN RESULTS: The EchoPAC v204 software (GE Vingmed Ultrasound AS, Norway) was used for analysis of 2D and 3D LVEF, LV GLS, LV global work index (GWI), LV global constructive work (GCW), LV global wasted work (GWW), and LV global work efficiency (GWE). The MW analysis was feasible in all patients. Although there was no significant difference in the values of 2D and 3D EF during the intraoperative interval, GLS deteriorated significantly after CABG compared to assessment after induction of anesthesia (T1 v T2, -13.3 ± 3.0% v -11.6 ± 3.1%; p = 0.012). The GWI declined significantly after surgery (T1 v T2, 1,224 ± 312 mmHg% v 940 ± 267 mmHg%; p < 0.001), as well as GCW (T1 v T2, 1,460 ± 312 mmHg% v 1,244 ± 336 mmHg%; p = 0.005). The GWW increased after CABG (T1 v T2, 143 mmHg% (IQR 99-183) v 251 mmHg% (IQR 179-361); p < 0.001), and GWE decreased (T1 v T2, 89% (IQR 85-92) v 80% (IQR 75-87); p < 0.001). There were no significant changes in the values of 2D and 3D EF, GLS, GWI, GCW, GWW, and GWE before and after sternal closure (T2 v T3). CONCLUSION: The intraoperative analysis of noninvasive echocardiographically-assessed LV MW indices is feasible. In the short-term period after uncomplicated on-pump CABG, GLS, as well as global and constructive MW, decreased, whereas wasted work increased, resulting in a less efficient left ventricle. None of these aspects was detected by conventional echocardiographic parameters. Therefore, strain and MW analysis might be more sensitive parameters in detecting myocardial dysfunction by TEE in the perioperative setting, adding information on perioperative cardiac energetics.


Assuntos
Ecocardiografia , Função Ventricular Esquerda , Humanos , Volume Sistólico , Ecocardiografia/métodos , Ponte de Artéria Coronária , Ecocardiografia Transesofagiana/métodos
4.
J Cardiothorac Vasc Anesth ; 37(10): 1912-1921, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37393132

RESUMO

OBJECTIVES: Left ventricular (LV) longitudinal function is reduced after on-pump coronary artery bypass grafting (CABG), while global LV function often is preserved. There are only limited data on the underlying compensatory mechanism. Therefore, the authors aimed to describe intraoperative changes of LV contractile pattern by myocardial strain analysis. DESIGN: A prospective observational study. SETTING: At a single university hospital. PARTICIPANTS: A total of 30 patients scheduled for isolated on-pump CABG with an uneventful intraoperative course and preoperative preserved LV and RV function, sinus rhythm, without more-than-mild heart valve disease, or elevated pulmonary pressure. INTERVENTIONS: Transesophageal echocardiography was performed after induction of anesthesia (T1), after termination of cardiopulmonary bypass (T2), and after sternal closure (T3). Echocardiographic evaluation was performed under stable hemodynamics, in sinus rhythm or atrial pacing, and vasopressor support with norepinephrine ≤0.1 µg/kg/min. MEASUREMENTS AND MAIN RESULTS: EchoPAC v204 software (GE Vingmed Ultrasound AS, Norway) was used for analysis of 2-dimensional (2D) and 3-dimensional (3D) LV ejection fraction (EF), LV global longitudinal strain (GLS), LV global circumferential strain (GCS), LV global radial strain (GRS), LV apical rotation (aRot), LV basal rotation (bRot), and LV twist. Strain analysis was feasible in all included patients after termination of cardiopulmonary bypass (T2). Although there were no significant differences in the values of conventional echocardiographic parameters during the intraoperative interval, GLS deteriorated significantly after CABG compared to pre-bypass assessment (T1 v T2, -13.4% ± 2.9 v -11.8% ± 2.9; p = 0.007). GCS improved significantly after surgery (T1 v T2, -19.4% (IQR -17.1% to -21.2%) v -22.8% (IQR -21.1% to -24.7%); p < 0.001) as well as aRot (T1 v T2, -9.7° (IQR -7.1° to -14.1°) v -14.5° (IQR -12.1° to -17.1°); p < 0.001), bRot (T1 v T2, 5.1° (IQR 3.8°-6.7°) v 7.2° (IQR 5.6°-8.2°); p = 0.02), and twist (T1 v T2, 15.8° (IQR 11.7°-19.4°) v 21.6° (IQR 19.2°-25.1°); p < 0.001), while GRS remained unchanged. There were no significant changes in the values of GLS, GCS, GRS, aRot, bRot, or twist, as well as in the values of 2D and 3D LV EF before and after sternal closure (T2 v T3). CONCLUSION: Beyond evaluation of longitudinal LV strain, measurements of circumferential and radial strain, as well as LV rotation and twist mechanics, were feasible in the intraoperative course of this study. Reduction of longitudinal function after on-pump CABG was compensated intraoperatively by improvement of GCS and rotation in the authors' group of patients. Perioperative assessment of GCS, GRS, as well as rotation and twist, might provide deeper insight into perioperative changes of cardiac mechanics.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Rotação , Volume Sistólico , Ecocardiografia/métodos , Ponte de Artéria Coronária , Disfunção Ventricular Esquerda/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem
5.
J Cardiothorac Vasc Anesth ; 36(1): 166-174, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34526240

RESUMO

OBJECTIVES: There are limited data on perioperative left ventricular strain. The authors aimed to describe the entire perioperative course of two-dimensional left ventricular global longitudinal strain in patients undergoing coronary artery bypass graft (CABG) surgery and compare to common parameters of LV function assessment. DESIGN: Prospective observational study. SETTING: Single university hospital. PARTICIPANTS: Forty patients scheduled for isolated on-pump CABG surgery with preserved left and right ventricular function with an unremarkable, complication-free perioperative course. INTERVENTIONS: Two-dimensional strain analysis and standard echocardiographic assessment of left ventricular function were performed pre- (T1) and postoperatively (T4) by transthoracic echocardiography (TTE) and intraoperatively pre- (T2) and poststernotomy (T3) by transesophageal echocardiography (TEE). Echocardiography was performed under stable hemodynamics and predefined fluid management, in sinus rhythm without any vasoactive support. MEASUREMENTS AND MAIN RESULTS: Analysis of two-dimensional LV global longitudinal strain (2D-LV GLS) was performed using Tomtec 2D Cardiac Performance Analysis software. Philips QLAB 10.8 was used to analyze left ventricular ejection fraction (LV EF) and tissue velocity of the lateral mitral annulus (LV S ́). There were no significant differences (median with interquartile range [IQR]) after induction of anesthesia in values of LV EF and 2D-LV GLS (T1 v T2; 59% [IQR, 52 to 64] v 56% [IQR, 51.75 to 63] and -15.2 [IQR, -18.05 to -13.08] v -15.6 [IQR, -17.65 to -13.88]; both not significant [ns]), while LV S´ declined (T1 v T2, 7 cm/s [IQR, 5.25 to 8] v 5.25 cm/s [IQR, 4.6 to 6.83]; p < 0.001). Bland-Altman analysis for this comparison of 2D-LV GLS (T1 v T2) showed that bias was not significant between both techniques; however, there were limits of agreement. After sternotomy (T2 v T3) neither LV EF nor 2D-LV GLS or LV S´ declined. 2D-LV GLS deteriorated significantly after CABG (T1 v T4; -15.2 [IQR, -18.05 to -13.08] v -11.3 [IQR, -15.8 to -9.78]; p < 0.001). In contrast, LV EF and LV S´ did not change significantly in the perioperative interval (T1 v T4; 59% [IQR, 52 to 64] v 56% [IQR, 51.5 to 64.25] and 7 cm/s [IQR, 5.25 to 8] v 7 cm/s [IQR, 6 to 8]; both ns). CONCLUSION: Values of 2D-LV GLS did not differ in awake, spontaneously breathing patients assessed by TTE and in anesthetized and ventilated patients with stable hemodynamics measured by TEE. 2D-LV GLS did not change after sternotomy; however, it declined significantly after on-pump CABG, while LV EF and LV S´ remained unchanged.


Assuntos
Ecocardiografia Tridimensional , Disfunção Ventricular Esquerda , Ponte de Artéria Coronária , Humanos , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda
6.
J Cardiothorac Vasc Anesth ; 35(6): 1628-1637, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33582011

RESUMO

OBJECTIVES: Few data exist on perioperative three-dimensional-derived right ventricular strain. The authors aimed to describe the perioperative course of three-dimensional-derived right ventricular strain in coronary artery bypass graft (CABG) surgery patients. DESIGN: Prospective, observational, pilot trial. SETTING: Single university hospital. PARTICIPANTS: The study comprised 40 patients with preserved left ventricular and right ventricular (RV) function undergoing isolated on-pump CABG surgery. INTERVENTIONS: Three-dimensional strain analysis and standard echocardiographic evaluation of RV function were performed preoperatively (T1) and postoperatively (T4) with transthoracic echocardiography (TTE) and intraoperatively before sternotomy (T2) and after sternotomy (T3) with transesophageal echocardiography (TEE). All echocardiographic measurements were performed under stable hemodynamic conditions and predefined fluid management without any vasoactive support. MEASUREMENTS AND MAIN RESULTS: The measurements of three-dimensional-derived RV free-wall strain (3D-RV FWS) and RV ejection fraction were performed using TomTec 4D RV-Function 2.0 software. Philips QLAB 10.8 was used to analyze tissue velocity of the tricuspid annulus, tricuspid annular systolic excursion, and RV fractional area change. There were no significant differences (median [interquartile range {IQR}]) between preoperative TTE and intraoperative TEE measurements for 3D-RV FWS (T1 v T2: -22.35 [IQR -17.70 to -27.22] v -24.35 [IQR -20.63 to -29.88]; not significant). 3D-RV FWS remained unchanged after sternotomy (T2 v T3: -24.35 [IQR -20.63 to -29.88] v -23.75 [IQR -20.25 to -29.28]; not significant) but deteriorated significantly after CABG (T1 v T4: -22.35 [IQR -17.70 to -27.22] v -18.5 [IQR -16.90 to -21.65]; p = 0.004). CONCLUSION: In patients undergoing on-pump CABG, 3D-RV FWS values for awake, spontaneously breathing patients measured with TTE and values assessed in patients under general anesthesia with TEE did not significantly differ. Three-dimensional RV FWS did not change after sternotomy but deteriorated after on-pump CABG.


Assuntos
Disfunção Ventricular Direita , Ponte de Artéria Coronária , Humanos , Projetos Piloto , Estudos Prospectivos , Função Ventricular Direita
7.
Artigo em Inglês | MEDLINE | ID: mdl-38880674
8.
A A Pract ; 18(7): e01826, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39008443

RESUMO

Right ventricular myocardial work is an echocardiographic technique yielding significant insights into cardiac mechanics, energetics, and efficiency. Combining right ventricular myocardial strain with loading conditions correlates with invasively measured myocardial work and myocardial oxygen consumption. This method has not yet been described intraoperatively by transesophageal echocardiography. We describe this technique during a left ventricular assist device implantation. This case demonstrates that right ventricular myocardial work indices can be monitored intraoperatively and might assist decisions during left ventricular assist device implantation.


Assuntos
Ecocardiografia Transesofagiana , Coração Auxiliar , Humanos , Masculino , Pessoa de Meia-Idade , Função Ventricular Direita/fisiologia , Ventrículos do Coração , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia
9.
Curr Anesthesiol Rep ; 11(3): 275-283, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34276252

RESUMO

PURPOSE OF THE REVIEW: The present review addresses clinicians and gives an overview about the experimental rationale for pharmacological conditioning associated with volatile anesthetics, opioids, and propofol; the current clinical data; and the technical considerations regarding the clinical routine in cardiac anesthesia. RECENT FINDINGS: Volatile anesthetics have been standard of care for general anesthesia for cardiac surgery, especially while using cardiopulmonary bypass. The 2019 published MYRIAD trial was not able to show a difference in mortality or cardiac biomarkers for volatile anesthetics compared to total intravenous anesthesia (TIVA), raising the question of equivalence with respect to patient outcome. SUMMARY: Reviewing the literature, the scientific foundation for the belief of clinically relevant conditioning by uninterrupted administration of a volatile anesthetic is weak. TIVA can also be performed safely in patients undergoing cardiac surgery.

10.
Laryngoscope ; 120(9): 1863-71, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20803741

RESUMO

OBJECTIVES: To estimate the effect of recovery of idiopathic sudden hearing loss under placebo (first aim) and under medical therapy (second aim). STUDY DESIGN: Systematic review and meta-analysis. METHODS: A total of 1,674 studies published between January 1974 and April 2009 were found following suggestions in the Cochrane Handbook for Systematic Reviews. After filtering by criteria of Cochrane Collaboration, four trials remained for continuous and two for dichotomous data. RESULTS: Using Review Manager, weighted mean difference as well as standardized mean effect of hearing recovery were calculated and pooled. The values for weighted mean difference of hearing gain in dB were 0.79, 95% confidence interval (CI) (-2.04-3.61) and for standardized mean effect 0.06, 95% CI (-0.13-0.24), respectively, which computationally favors active treatment, but statistically is not significantly different from no effect (0 dB). This was in accordance to the comparison of descriptive means between recovery under placebo with 14.3 dB and active treatment with 15.8 dB hearing gain. Treatment effect of dichotomous data (hearing gain vs. no hearing gain) suggested a statistically significant better outcome for active treatment; the odds ratio (OR) [fixed] is 2.18 (1.06-4.46). CONCLUSIONS: In five different statistical analysis methods used, treatment effect of medical therapy was slightly better than recovery under placebo in which spontaneous recovery could be assumed, but no significant effect was detected. Against the background of recovery under placebo of 14.3 dB vs. 15.8 dB hearing gain of active treatment as averages of all measured frequencies, recovery under placebo seems not to have worse outcome than recovery under medical therapy.


Assuntos
Perda Auditiva Súbita/tratamento farmacológico , Administração Oral , Citratos/administração & dosagem , Ensaios Clínicos Controlados como Assunto , Dexametasona/administração & dosagem , Dextranos/administração & dosagem , Epoprostenol/administração & dosagem , Epoprostenol/análogos & derivados , Seguimentos , Humanos , Infusões Intravenosas , Metilprednisolona/administração & dosagem , Pentoxifilina/administração & dosagem , Prednisona/administração & dosagem , Procaína/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa