Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Dig Endosc ; 32(4): 557-564, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31483889

RESUMO

AIM: To compare feasibility and safety after gastrointestinal checkup by standing-type magnetically controlled capsule endoscopy (SMCE) and conventional gastroscopy. METHODS: This was a prospective multicenter, blinded study that compared SMCE with gastroscopy in patients from April 2018 to July 2018. All patients first underwent SMCE and then subsequently had gastroscopy with i.v. anesthesia. We calculated the compliance rates of gastric lesion detection by SMCE using gastroscopy as the standard. Capsule retention rate, incidence of adverse events, and patient satisfaction were documented throughout the study. RESULTS: One hundred and sixty-one patients who completed SMCE and gastroscopy were included in the analysis. Positive compliance rate among SMCE and gastroscopy was 92.0% (95% CI: 80.77%-97.78%). Negative compliance rate was 95.5% (89.80%, 98.52%). Moreover, overall compliance rate was 94.41% (89.65%, 97.41%). Sixty-four pathological outcomes were identified. Of these 64 outcomes, 50 were detected by both procedures. The gastroscopy method neglected seven findings (such as five erosions, one polyp, and one ulcer). Furthermore, SMCE also overlooked seven lesions (i.e. one erosion, two polyps, one atrophy, and three submucosal tumors). Capsule retention or related adverse events were not reported. CONCLUSION: Standing-type magnetically controlled capsule endoscopy provides equivalent agreement with gastroscopy and may be useful for screening of gastric illnesses without any anesthesia.


Assuntos
Cápsulas Endoscópicas , Endoscopia por Cápsula/instrumentação , Gastroscopia , Magnetismo , Gastropatias/diagnóstico , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Preferência do Paciente , Método Simples-Cego
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 26(8): 1377-81, 2006 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-17058926

RESUMO

In the present the authors are trying to work out how the quantum efficiency depends on the nanocrystalline size. Cubic nanocrystalline Y2O3 : Eu3+ samples were prepared by chemical self-combustion. The bulk Y2O3 : Eu3+ was obtained by annealing the nanocrystalline at 1 000 degrees C for 2 h. The emission spectra, XRD and fluorescence decay showed that the emission intensities are increased and fluorescence decay becomes slow with an increase in particle diameter of the samples. Two routes were used to estimate the quantum efficiency of the 5D0 level of Eu3+ at C2 site. The quantum efficiencies of 5D0 level of Eu3+ at C2 site in the samples depend on the nanocrystalline sizes. Finally, a detailed discussion about these two approaches for estimating the quantum efficiencies was made.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa