Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Analyst ; 147(14): 3315-3327, 2022 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-35762367

RESUMO

The COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of virologic failure and HIV-associated illness. Often this population is at high risk for exposure to SARS-CoV-2 infection, and once infected, for severe disease. Therefore, close monitoring of HIV plasma viral load (VL) and screening for SARS-CoV-2 infection are needed. We developed a non-proprietary method to isolate RNA from plasma, nasal secretions (NS), or both. The extracted RNA is then submitted to RT-qPCR to estimate the VL and classify HIV/SARS-CoV-2 status (i.e., HIV virologic failure or suppressed; SARS-CoV-2 as positive, presumptive positive, negative, or indeterminate). In contrived samples, the in-house RNA extraction workflow achieved a detection limit of 200-copies per mL for HIV RNA in plasma and 100-copies per mL for SARS-CoV-2 RNA in NS. Similar detection limits were observed for HIV and SARS-CoV-2 in pooled plasma/NS contrived samples. When comparing in-house with standard extraction methods, we found high agreement (>0.91) between input and measured RNA copies for HIV LTR in contrived plasma; SARS-CoV-2 N1/N2 in contrived NS; and LTR, N1, and N2 in pooled plasma/NS samples. We further evaluated this workflow on 133 clinical specimens: 40 plasma specimens (30 HIV-positive), 67 NS specimens (31 SARS-CoV-2-positive), and 26 combined plasma/NS specimens (26 HIV-positive with 10 SARS-CoV-2-positive), and compared the results obtained using the in-house RNA extraction to those using a commercial kit (standard extraction method). The in-house extraction and standard extraction of clinical specimens were positively correlated: plasma HIV VL (R2 of 0.81) and NS SARS-CoV-2 VL (R2 of 0.95 and 0.99 for N1 and N2 genes, respectively); and pooled plasma/NS HIV VL (R2 of 0.71) and SARS-CoV-2 VL (R2 of 1 both for N1 and N2 genes). Our low-cost molecular test workflow ($1.85 per pooled sample extraction) for HIV RNA and SARS-CoV-2 RNA could serve as an alternative to current standard assays ($12 per pooled sample extraction) for laboratories in low-resource settings.


Assuntos
COVID-19 , Infecções por HIV , COVID-19/diagnóstico , Infecções por HIV/diagnóstico , Humanos , Pandemias , RNA Viral/análise , SARS-CoV-2/genética , Sensibilidade e Especificidade , Carga Viral/métodos , Fluxo de Trabalho
2.
Anal Chem ; 88(21): 10404-10410, 2016 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-27686335

RESUMO

Magnetic microbeads exhibit rapid separation characteristics and are widely employed for biomolecule and cell isolations in research laboratories, clinical diagnostics assays, and cell therapy manufacturing. However, micrometer particle diameters compromise biomarker recognition, which leads to long incubation times and significant reagent demands. Here, a stimuli-responsive binary reagent system is presented that combines the nanoscale benefits of efficient biomarker recognition and the microscale benefits of rapid magnetic separation. This system comprises magnetic nanoparticles and polymer-antibody (Ab) conjugates that transition from hydrophilic nanoscale reagents to microscale aggregates in response to temperature stimuli. The binary reagent system was benchmarked against Ab-labeled Dynabeads in terms of biomarker isolation kinetics, assay speed, and reagent needs. Surface plasmon resonance (SPR) measurements showed that polymer conjugation did not significantly alter the Ab's binding affinity or kinetics. ELISA analysis showed that the unconjugated Ab, polymer-Ab conjugates, and Ab-labeled Dynabeads exhibited similar equilibrium dissociation constants (Kd), ∼2 nM. However, the binary reagent system isolated HIV p24 antigen from spiked serum specimens (150 pg/mL) much more quickly than Dynabeads, which resulted in shorter binding times by tens of minutes, or about 30-50% shorter overall assay times. The binary reagent system showed improved performance because the Ab molecules were not conjugated to large, solid microparticle surfaces. This stimuli-responsive binary reagent system illustrates the potential advantages of nanoscale reagents in molecule and cell isolations for both research and clinical applications.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Proteína do Núcleo p24 do HIV/sangue , Imunoconjugados/química , Nanopartículas de Magnetita/química , Polímeros/química , Ressonância de Plasmônio de Superfície/métodos , Biomarcadores/sangue , HIV/isolamento & purificação , Proteína do Núcleo p24 do HIV/análise , Infecções por HIV/sangue , Humanos , Interações Hidrofóbicas e Hidrofílicas , Indicadores e Reagentes , Multimerização Proteica , Temperatura
3.
Pharm Res ; 33(10): 2411-20, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27401412

RESUMO

PURPOSE: In order to improve the detection limit of existing HIV diagnostic assays, we explored the use of a temperature-responsive magnetic nanoparticle reagent system in conjunction with cyanovirin-N for HIV recognition to rapidly and efficiently concentrate viral particles from larger sample volumes, ~ 1 ml. METHODS: Cyanovirin-N (CVN) mutant, Q62C, was expressed, biotinylated, and then complexed with a thermally responsive polymer-streptavidin conjugate. Confirmation of protein expression/activity was performed using matrix assisted laser desorption/ionization (MALDI) and a TZM-bl HIV inhibition assay. Biotinylated CVN mutant recognition with gp120 was characterized using surface plasmon resonance (SPR). Virus separation and enrichment using a thermoresponsive magnetic nanoparticle reagent system were measured using RT-PCR. RESULTS: Biotinylated Q62C exhibited a KD of 0.6 nM to gp120. The temperature-responsive binary reagent system achieved a maximum viral capture of nearly 100% HIV, 1 × 10(5) virus copies in 100 µl, using pNIPAAm-Q62C within 30 minutes. Additionally, the same reagent system achieved nearly 9-fold enrichment by processing a 10-times larger sample of 1000 µl (Fig. 3). CONCLUSION: This work demonstrated a temperature-responsive reagent system that provides enrichment of HIV using antiviral lectin CVN for recognition, which is potentially amenable for use in point-of-care settings.


Assuntos
Antivirais/metabolismo , Proteínas de Bactérias/metabolismo , Proteínas de Transporte/metabolismo , HIV-1/metabolismo , Lectinas/metabolismo , HIV-1/isolamento & purificação , Humanos , Ligação Proteica/fisiologia , Ressonância de Plasmônio de Superfície/métodos , Temperatura
4.
Bioconjug Chem ; 26(1): 29-38, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25405605

RESUMO

Immunoassays have been translated into microfluidic device formats, but significant challenges relating to upstream sample processing still limit their applications. Here, stimuli-responsive polymer-antibody conjugates are utilized in a microfluidic immunoassay to enable rapid biomarker purification and enrichment as well as sensitive detection. The conjugates were constructed by covalently grafting poly(N-isopropylacrylamide) (PNIPAAm), a thermally responsive polymer, to the lysine residues of anti-prostate specific antigen (PSA) Immunoglobulin G (IgG) using carbodiimide chemistry via the polymer end-carboxylate. The antibody-PNIPAAm (capture) conjugates and antibody-alkaline phosphatase (detection) conjugates formed sandwich immunocomplexes via PSA binding in 50% human plasma. The complexes were loaded into a recirculating poly(dimethylsiloxane) microreactor, equipped with micropumps and transverse flow features, for subsequent separation, enrichment, and quantification. The immunocomplexes were captured by heating the solution to 39 °C, mixed over the transverse features for 2 min, and washed with warm buffer. In one approach, the assay utilized immunocomplex solution that was contained in an 80 nL microreactor, which was loaded with solution at room temperature and subsequently heated to 39 °C. The assay took 25 min and resulted in 37 pM PSA limit of detection (LOD), which is comparable to a plate ELISA employing the same antibody pair. In another approach, the microreactor was preheated to 39 °C, and immunocomplex solution was flowed through the reactor, mixed, and washed. When the specimen volume was increased to 7.5 µL by repeating the capture process three times, the higher specimen volume led to immunocomplex enrichment within the microreactor. The resulting assay LOD was 0.5 pM, which is 2 orders of magnitude lower than the plate ELISA. Both approaches generate antigen specific signal over a clinically significant range. The sample processing capabilities and subsequent utility in a biomarker assay demonstrate the opportunity for stimuli-responsive polymer-protein conjugates in novel diagnostic technologies.


Assuntos
Imunoensaio/métodos , Técnicas Analíticas Microfluídicas/métodos , Resinas Acrílicas/química , Biomarcadores/sangue , Biomarcadores/química , Dimetilpolisiloxanos/química , Humanos , Imunoglobulina G/química , Imunoglobulina G/imunologia , Indicadores e Reagentes/química , Antígeno Prostático Específico/sangue , Antígeno Prostático Específico/química , Antígeno Prostático Específico/imunologia , Antígeno Prostático Específico/isolamento & purificação
5.
J Nanosci Nanotechnol ; 14(3): 2557-62, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24745263

RESUMO

Herein, we report the synthesis and characterization of monodisperse 'smart' nanogels that exhibit a sharp volume phase transition at physiologically relevant temperatures and pH values. The nanogels were prepared by precipitation copolymerization of N-isopropylacrylamide (NIPAAm) and propylacrylic acid (PAA). Briefly, the reaction was performed using a PAA feed of between 0 and 10 mol% in the presence of a crosslinker at 70 degrees C. The size of the nanogel particles was determined as a function of pH and temperature using dynamic light scattering (DLS). At room temperature, the NIPAAm-PAA nanogels were discrete, spherical structures with diameters ranging from 200 to 250 nm. The hydrodynamic diameter of the nanogels decreased to ca. 100-150 nm when the solution temperature was increased to 37 degrees C. At 37 degrees C, when the pKa was below that of the NIPAAm-PAA (ca. 6.0), the gels collapsed and aggregated. However, at 37 degrees C and a physiological pH of 7.4, the nanogels did not fully collapse due to the charge-charge repulsion derived from the ionized carboxyl groups of the PAA. Similar phase transition behavior was observed with the corresponding linear copolymers. Thus, such nanogel particles could be useful for releasing drugs in regions of local acidosis, including sites of infection, tumors, ischemia, and intracellular endosomes.


Assuntos
Nanopartículas/química , Nanotecnologia/métodos , Acrilamidas/química , Acrilatos/química , Sistemas de Liberação de Medicamentos , Géis , Concentração de Íons de Hidrogênio , Luz , Microscopia Eletrônica de Transmissão , Tamanho da Partícula , Espalhamento de Radiação , Temperatura
6.
Chonnam Med J ; 60(1): 1-12, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38304124

RESUMO

Extracellular vesicles (EVs) function as potent mediators of intercellular communication for many in vivo processes, contributing to both health and disease related conditions. Given their biological origins and diverse functionality from correspondingly unique "cargo" compositions, both endogenous and modified EVs are garnering attention as promising therapeutic modalities and vehicles for targeted therapeutic delivery applications. Their diversity in composition, however, has revealed a significant need for more comprehensive analytical-based characterization methods, and manufacturing processes that are consistent and scalable. In this review, we explore the dynamic landscape of EV research and development efforts, ranging from novel isolation approaches, to their analytical assessment through novel characterization techniques, and to their production by industrial-scale manufacturing process considerations. Expanding the horizon of these topics to EVs for in-human applications, we underscore the need for stringent development and adherence to Good Manufacturing Practice (GMP) guidelines. Wherein, the intricate interplay of raw materials, production in bioreactors, and isolation practices, along with analytical assessments compliant with the Minimal Information for Studies of Extracellular Vesicles (MISEV) guidelines, in conjunction with reference standard materials, collectively pave the way for standardized and consistent GMP production processes.

7.
Anal Chim Acta ; 1307: 342560, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719398

RESUMO

BACKGROUND: Point-of-care (POC) nucleic acid amplification tests (NAAT) can significantly expand testing coverage, which is critical for infectious disease diagnostics and monitoring. The development of various isothermal amplification techniques greatly simplifies NAATs, but the cumbersome nucleic acid extraction step remains a bottleneck for the POC. Alternatively, extraction-free amplification, where crude samples are directly added into the assay, substantially simplifies the workflow. However, sample dilution is often needed in extraction-free amplification to reduce assay inhibition from sample matrices. Since NAATs are typically run at small volumes around 20 µL, the input sample quantity is therefore limited, resulting in an inevitable sensitivity loss. RESULTS: Here we explore the potential to perform isothermal amplification in larger reaction volumes to accommodate larger sample quantities, thereby improving sensitivity in extraction-free amplification. We demonstrated the approach by developing large-volume reverse transcription loop-mediated isothermal amplification (RT-LAMP) for HIV RNA detection from fingerstick plasma. We found that LAMP at reaction volumes up to 1 mL maintained the same performance. We then identified plasma dilution conditions needed to maintain the limit of detection in RT-LAMP. Subsequently, using inactivated HIV virus, we showed the successful detection of 24 HIV RNA copies in a 500 µL RT-LAMP reaction in the presence of 20 µL plasma (fingerstick volumes), translating to a viral load of 1200 copies per mL. To reduce the increased reagent cost with expanded reaction volumes, we further identified lower-cost reagents with maintained assay performance. Moreover, we showed that large-volume LAMP, compared to 20 µL reactions, could tolerate higher concentrations of various inhibitors in the sample, such as albumin and GuSCN. SIGNIFICANCE AND NOVELTY: NAATs are conventionally conducted at small reaction volumes. Here we demonstrated that LAMP can be run at large reaction volumes (over 100 µL) with maintained assay performance, allowing sample inhibition to be mitigated while accommodating larger sample quantities. The same strategy of expanding reaction volumes could be applied to other isothermal amplification methods and various POC applications, to streamline test workflows and/or improve assay sensitivity.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , RNA Viral , Técnicas de Amplificação de Ácido Nucleico/métodos , Humanos , RNA Viral/sangue , Infecções por HIV/sangue , Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV-1/genética , HIV-1/isolamento & purificação , Limite de Detecção , Técnicas de Diagnóstico Molecular
8.
medRxiv ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38633802

RESUMO

Pathogens encapsulate or encode their own suite of enzymes to facilitate replication in the host. The pathogen-derived enzymes possess specialized activities that are essential for pathogen replication and have naturally been candidates for drug targets. Phenotypic assays detecting the activities of pathogen-derived enzymes and characterizing their inhibition under drugs offer an opportunity for pathogen detection, drug resistance testing for individual patients, and as a research tool for new drug development. Here, we used HIV as an example to develop assays targeting the reverse transcriptase (RT) enzyme encapsulated in HIV for sensitive detection and phenotypic characterization, with the potential for point-of-care (POC) applications. Specifically, we targeted the complementary (cDNA) generation activity of the HIV RT enzyme by adding engineered RNA as substrates for HIV RT enzyme to generate cDNA products, followed by cDNA amplification and detection facilitated by loop-mediated isothermal amplification (LAMP) or CRISPR-Cas systems. To guide the assay design, we first used qPCR to characterize the cDNA generation activity of HIV RT enzyme. In the LAMP-mediated Product-Amplified RT activity assay (LamPART), the cDNA generation and LAMP amplification were combined into one pot with novel assay designs. When coupled with direct immunocapture of HIV RT enzyme for sample preparation and endpoint lateral flow assays for detection, LamPART detected as few as 20 copies of HIV RT enzyme spiked into 25µL plasma (fingerstick volume), equivalent to a single virion. In the Cas-mediated Product-Amplified RT activity assay (CasPART), we tailored the substrate design to achieve a LoD of 2e4 copies (1.67fM) of HIV RT enzyme. Furthermore, with its phenotypic characterization capability, CasPART was used to characterize the inhibition of HIV RT enzyme under antiretroviral drugs and differentiate between wild-type and mutant HIV RT enzyme for potential phenotypic drug resistance testing. Moreover, the CasPART assay can be readily adapted to target the activity of other pathogen-derived enzymes. As a proof-of-concept, we successfully adapted CasPART to detect HIV integrase with a sensitivity of 83nM. We anticipate the developed approach of detecting enzyme activity with product amplification has the potential for a wide range of pathogen detection and phenotypic characterization.

9.
Langmuir ; 29(18): 5388-93, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23581256

RESUMO

A microfluidic surface trap was developed for capturing pH-sensitive nanoparticles via a photoinitiated proton-releasing reaction of o-nitrobenzaldehyde (o-NBA) that reduces the solution pH in microchannels. The surface trap and nanoparticles were both modified with a pH-responsive polymer-poly(N-isorpopylacylamide-co-propylacrylic acid), P(NIPAAm-co-PAA). The o-NBA-coated microchannel walls demonstrated rapid proton release upon UV light irradiation, allowing the buffered solution pH in the microchannel to decrease from 7.4 to 4.5 in 60 s. The low solution pH switched the polymer-modified surfaces to be more hydrophobic, which enabled the capture of the pH-sensitive nanobeads onto the trap. When a photomask was utilized to limit the UV irradiation to a specific channel region, we were able to restrict the particle separation to only the exposed region. Via control of the UV irradiation, this technique enables not only prompt pH changes within the channel but also the capture of target molecules at specific channel locations.


Assuntos
Nanopartículas/química , Raios Ultravioleta , Benzaldeídos/química , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Técnicas Analíticas Microfluídicas/instrumentação , Processos Fotoquímicos , Polímeros/química , Propriedades de Superfície
10.
Anal Chim Acta ; 1277: 341674, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37604625

RESUMO

Lateral flow assays (LFAs) provide a simple and quick option for diagnosis and are widely adopted for point-of-care or at-home tests. However, their sensitivity is often limited. Most LFAs only allow 50 µL samples while various sample types such as saliva could be collected in much larger volumes. Adapting LFAs to accommodate larger sample volumes can improve assay sensitivity by increasing the number of target analytes available for detection. Here, a simple agglutination system comprising biotinylated antibody (Ab) and streptavidin (SA) is presented. The Ab and SA agglutinate into large aggregates due to multiple biotins per Ab and multiple biotin binding sites per SA. Dynamic light scattering (DLS) measurements showed that the agglutinated aggregate could reach a diameter of over 0.5 µm and over 1.5 µm using poly-SA. Through both experiments and Monte Carlo modeling, we found that high valency and equivalent concentrations of the two aggregating components were critical for successful agglutination. The simple agglutination system enables antigen capture from large sample volumes with biotinylated Ab and a swift transition into aggregates that can be collected via filtration. Combining the agglutination system with conventional immunoassays, an agglutination assay is proposed that enables antigen detection from large sample volumes using an in-house 3D-printed device. As a proof-of-concept, we developed an agglutination assay targeting SARS-CoV-2 nucleocapsid antigen for COVID-19 diagnosis from saliva. The assay showed a 10-fold sensitivity enhancement when increasing sample volume from 50 µL to 2 mL, with a final limit of detection (LoD) of 10 pg mL-1 (∼250 fM). The assay was further validated in negative saliva spiked with gamma-irradiated SARS-CoV-2 and showed an LoD of 250 genome copies per µL. The proposed agglutination assay can be easily developed from existing LFAs to facilitate the processing of large sample volumes for improved sensitivity.


Assuntos
Teste para COVID-19 , COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Anticorpos , Biotina , Aglutinação
11.
J Extracell Biol ; 2(5): e86, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-38938283

RESUMO

Calorie restriction (CR) and fasting affect lifespan, disease susceptibility and response to acute injury across multiple animal models, including ischaemic injuries such as myocardial infarction or kidney hypoxia. The cargo and function of circulating extracellular vesicles (EV) respond to changes in host physiology, including exercise, injury, and other interventions. Thus, we hypothesised that EVs induced following CR may reflect some of the beneficial properties of CR itself. In a pilot study, EVs were isolated from mice following 21 days of 30 % CR, and from eight human donors after 72 h water-only fasting. EV size, concentration and morphology were profiled by NTA, western blot and cryoEM, and their function was assessed using multiple assays related to ischaemic diseases. We found that EVs from post-fasting samples better protected cardiac cells from hypoxia/reperfusion (H/R) injury compared to pre-fasting EVs. However, there was no difference when used to treat H/R-injured kidney epithelial cells. Post-fasting derived EVs slowed the rate of fibroblast migration and slightly reduced macrophage inflammatory gene expression compared to pre-fasting derived EVs. Lastly, we compared miRNA cargos of pre- and post-fasting human serum EVs and found significant changes in a small number of miRNAs. We conclude that fasting appears to influence EV cargo and function, with varied effects worthy of further exploration.

12.
Front Bioeng Biotechnol ; 10: 884271, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35721843

RESUMO

Urine is an attractive biospecimen for in vitro diagnostics, and urine-based lateral flow assays are low-cost devices suitable for point-of-care testing, particularly in low-resource settings. However, some of the lateral flow assays exhibit limited diagnostic utility because the urinary biomarker concentration is significantly lower than the assay detection limit, which compromises the sensitivity. To address the challenge, we developed an osmotic processor that statically and spontaneously concentrated biomarkers. The specimen in the device interfaces with the aqueous polymer solution via a dialysis membrane. The polymer solution induces an osmotic pressure difference that extracts water from the specimen, while the membrane retains the biomarkers. The evaluation demonstrated that osmosis induced by various water-soluble polymers efficiently extracted water from the specimens, ca. 5-15 ml/h. The osmotic processor concentrated the specimens to improve the lateral flow assays' detection limits for the model analytes-human chorionic gonadotropin and SARS-CoV-2 nucleocapsid protein. After the treatment via the osmotic processor, the lateral flow assays detected the corresponding biomarkers in the concentrated specimens. The test band intensities of the assays with the concentrated specimens were very similar to the reference assays with 100-fold concentrations. The mass spectrometry analysis estimated the SARS-CoV-2 nucleocapsid protein concentration increased ca. 200-fold after the osmosis. With its simplicity and flexibility, this device demonstrates a great potential to be utilized in conjunction with the existing lateral flow assays for enabling highly sensitive detection of dilute target analytes in urine.

13.
Biomaterials ; 289: 121807, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36166894

RESUMO

We hypothesized that the host microbiome may influence foreign body responses following biomaterial implantation. To test this, we implanted a variety of clinically relevant biomaterials into germ-free or antibiotic-treated mice. Surprisingly, these mice displayed less fibrous tissue deposition, reduced host cell recruitment to the implant site, and differential expression of angiogenic and inflammatory markers. These observations were reversed upon fecal microbiome reconstitution, confirming a causal role of the host microbiome. In a clinically relevant disease model, microbiome-depleted mice cleared hyaluronic acid and bone marrow mononuclear cells from ischemic hind limb tissues more slowly, resulting in an improved therapeutic response. Findings were confirmed in pigs which showed reduced fibrotic responses to a variety of implanted materials. Lastly, we profiled changes in the host microbiome following material implantation, implicating several key bacteria phyla.


Assuntos
Materiais Biocompatíveis , Microbioma Gastrointestinal , Animais , Antibacterianos , Reação a Corpo Estranho , Ácido Hialurônico , Camundongos , Suínos
14.
Adv Sci (Weinh) ; 9(15): e2103222, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35332686

RESUMO

Exosomes are extracellular vesicles that share components of their parent cells and are attractive in biotechnology and biomedical research as potential disease biomarkers as well as therapeutic agents. Crucial to realizing this potential is the ability to manufacture high-quality exosomes; however, unlike biologics such as proteins, exosomes lack standardized Good Manufacturing Practices for their processing and characterization. Furthermore, there is a lack of well-characterized reference exosome materials to aid in selection of methods for exosome isolation, purification, and analysis. This review informs exosome research and technology development by comparing exosome processing and characterization methods and recommending exosome workflows. This review also provides a detailed introduction to exosomes, including their physical and chemical properties, roles in normal biological processes and in disease progression, and summarizes some of the on-going clinical trials.


Assuntos
Exossomos , Vesículas Extracelulares , Exossomos/química , Exossomos/metabolismo , Desenvolvimento Industrial , Proteínas/metabolismo
15.
PLOS Glob Public Health ; 2(2): e0000185, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36962187

RESUMO

Usability is an overlooked aspect of implementing lab-based assays, particularly novel assays in low-resource-settings. Esoteric instructions can lead to irreproducible test results and patient harm. To address these issues, we developed a software application based on "Aquarium", a laboratory-operating system run on a computer tablet that provides step-by-step digital interactive instructions, protocol management, and sample tracking. Aquarium was paired with a near point-of-care HIV drug resistance test, "OLA-Simple", that detects mutations associated with virologic failure. In this observational study we evaluated the performance of Aquarium in guiding untrained users through the multi-step laboratory protocol with little supervision. To evaluate the training by Aquarium software we conducted a feasibility study in a laboratory at Coptic Hope Center in Nairobi, Kenya. Twelve volunteers who were unfamiliar with the kit performed the test on blinded samples (2 blood specimens; 5 codons/sample). Steps guided by Aquarium included: CD4+ T-Cell separation, PCR, ligation, detection, and interpretation of test results. Participants filled out a short survey regarding their demographics and experience with the software and kit. None of the laboratory technicians had prior experience performing CD4+ separation and 7/12 had no experience performing laboratory-based molecular assays. 12/12 isolated CD4+ T cells from whole blood with yields comparable to isolations performed by trained personnel. The OLA-Simple workflow was completed by all, with genotyping results interpreted correctly by unaided-eye in 108/120 (90%) and by software in 116/120 (97%) of codons analyzed. In the surveys, participants favorably assessed the use of software guidance. The Aquarium digital instructions enabled first-time users in Kenya to complete the OLA-simple kit workflow with minimal training. Aquarium could increase the accessibility of laboratory assays in low-resource-settings and potentially standardize implementation of clinical laboratory tests.

16.
Nano Lett ; 10(1): 85-91, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20017498

RESUMO

We report a new strategy for synthesizing temperature-responsive gamma-Fe(2)O(3)-core/Au-shell nanoparticles (Au-mNPs) from diblock copolymer micelles. The amphiphilic diblock copolymer chains were synthesized using reversible addition-fragmentation chain-transfer (RAFT) with a thermally responsive "smart" poly(N-isopropylacrylamide) (pNIPAAm) block and an amine-containing poly(N,N-dimethylaminoethylacrylamide) (DMAEAm) block that acted as a reducing agent during gold shell formation. The Au-mNPs reversibly aggregated upon heating the solution above the transition temperature of pNIPAAm, resulting in a red-shifted localized surface plasmon resonance.


Assuntos
Ouro/química , Nanopartículas Metálicas/química , Micelas , Nanotecnologia/métodos , Acrilamidas/química , Resinas Acrílicas/química , Biotecnologia/métodos , Magnetismo , Microscopia Eletrônica de Transmissão/métodos , Nanopartículas/química , Nanotecnologia/instrumentação , Polímeros/química , Ressonância de Plasmônio de Superfície , Temperatura
17.
ACS Appl Mater Interfaces ; 13(22): 25663-25673, 2021 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-34032419

RESUMO

Nanoscale coordination polymers are promising vehicles for anticancer drug delivery because their surface composition and particle size can be tuned to exploit the enhanced permeability and retention effect, and their reversible interaction with metal cations enables triggered drug release at the tumor site. Here, we develop a novel nanoscale coordination polymer using the diblock copolymer poly(2-methacryloyloxyethyl phosphorylcholine)-block-poly(serinyl acrylate) (PMPC-b-PserA) and demonstrate its use for encapsulation of a hydrophobic drug and triggered drug release to induce breast cancer cell apoptosis in vitro. The zwitterionic PMPC block was inspired by the antifouling structure of cell membranes, and the PserA block was inspired by the amphoteric amino acids of proteins. The polymer was synthesized by reversible addition-fragmentation chain transfer polymerization, and a mixture of the polymer and FeCl3 self-assembled into nanoparticles via complexation of Fe3+ with PserA, with the hydrophilic PMPC block at the particle surface. At a molar ratio of Fe3+ to serA of 3:1, the hydrodynamic diameter of the particles was 22.2 nm. Curcumin, a natural water-insoluble polyphenol used to enhance the effects of chemotherapeutics, was encapsulated in the particles as an oil-in-water emulsion, with an encapsulation efficiency of 99.6% and a particle loading capacity of 32%. Triggered release of curcumin was achieved by adding deferoxamine, an FDA-approved Fe3+ chelating agent; curcumin release efficiency increased at higher deferoxamine concentrations and lower pH. Triggered release of curcumin induced apoptosis in human triple-negative breast cancer cells; cell viability decreased to 34.3% after 24 h of treatment with the curcumin-loaded nanoparticles and deferoxamine, versus >80% viability without deferoxamine to trigger drug release. The biocompatibility, tunable composition and size, high hydrophobic drug loading, and triggered-release capability of this nanoscale coordination polymer make it well-suited for use in anticancer drug delivery.


Assuntos
Curcumina/farmacologia , Sistemas de Liberação de Medicamentos , Liberação Controlada de Fármacos , Metais/química , Nanopartículas/administração & dosagem , Polímeros/química , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Antineoplásicos/química , Antineoplásicos/farmacologia , Sobrevivência Celular , Curcumina/química , Portadores de Fármacos/química , Feminino , Humanos , Concentração de Íons de Hidrogênio , Nanopartículas/química , Polietilenoglicóis , Neoplasias de Mama Triplo Negativas/metabolismo , Neoplasias de Mama Triplo Negativas/patologia , Células Tumorais Cultivadas
18.
Biomater Sci ; 9(14): 4870-4879, 2021 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-33904566

RESUMO

Early diagnosis of infectious diseases is one of the current prevalent challenges, especially in low and limited resource settings where simple, fast, portable, cheap, and sensitive diagnostic approaches are needed. Lateral flow immunoassay (LFIA) is a common, rapid screening assay. However, the low assay sensitivity limits the utility of LFIA for specimens with low pathogenic loads (early infection stages). Antibodies conjugated with stimulus-responsive polymers have been previously utilized to improve assay sensitivity for detection of biomarkers at low concentrations. However, the loss of antibody affinity after polymer conjugation remains a significant challenge. In this study, we developed poly(N-isopropylacrylamide-co-N-(2-hydroxyisopropyl)acrylamide-co-strained alkyne-isopropylacrylamide), a novel polymer for biomarker enrichment, by polymer conjugation after antibody-antigen recognition. We employed and promoted the click chemistry in situ, to facilitate highly specific conjugation between novel temperature-responsive polymers and antibody-antigen complexes. This method could suppress the decrease in the binding constant associated with polymer conjugation (>20-fold). The conjugation was successfully demonstrated in body fluids such as urine and saliva. We achieved >5-fold antigen enrichment via thermal precipitation by conjugating polymers to the antibodies after antigen recognition. Concentrated biomarkers resulted in improved LFIA detection. This approach can potentially be utilized to improve diagnostic tests for infectious diseases in low and limited resource settings.


Assuntos
Testes Diagnósticos de Rotina , Polímeros , Anticorpos , Biomarcadores , Temperatura
19.
medRxiv ; 2021 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-34462759

RESUMO

BACKGROUND: COVID-19 pandemic interrupted routine care for individuals living with HIV, putting them at risk of becoming virologically unsuppressed and ill. Often they are at high risk for exposure to SARS-CoV-2 infection and severe disease once infected. For this population, it is urgent to closely monitor HIV plasma viral load ( VL ) and screen for SARS-COV-2 infection. METHOD: We have developed a non-proprietary method to isolate RNA from plasma, nasal secretions ( NS ), or both. HIV, SARS-CoV-2, and human RP targets in extracted RNA are then RT-qPCR to estimate the VL and classify HIV/SARS-CoV-2 status ( i . e ., HIV as VL failure or suppressed; SARS-CoV-2 as positive, presumptive positive, negative, or indeterminate). We evaluated this workflow on 133 clinical specimens: 40 plasma specimens (30 HIV-seropositive), 67 NS specimens (31 SARS-CoV-2-positive), and 26 pooled plasma/NS specimens (26 HIV-positive with 10 SARS-CoV-2-positive), and compared the results obtained using the in-house extraction to those using a commercial extraction kit. RESULTS: In-house extraction had a detection limit of 200-copies/mL for HIV and 100-copies/mL for SARS-CoV-2. In-house and commercial methods yielded positively correlated HIV VL (R 2 : 0.98 for contrived samples; 0.81 for seropositive plasma). SARS-CoV-2 detection had 100% concordant classifications in contrived samples, and in clinical NS extracted by in-house method, excluding indeterminate results, was 95% concordant (25 positives, 6 presumptive positives, and 31 negatives) to those using the commercial method. Analysis of pooled plasma/NS showed R 2 of 0.91 (contrived samples) and 0.71 (clinical specimens) for HIV VL correlations obtained by both extraction methods, while SARS-CoV-2 detection showed 100% concordance in contrived and clinical specimens. INTERPRETATION: Our low-cost workflow for molecular testing of HIV and SARS-CoV-2 could serve as an alternative to current standard assays for laboratories in low-resource settings.

20.
Sci Adv ; 7(17)2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33893103

RESUMO

The delivery of therapeutics through the circulatory system is one of the least arduous and less invasive interventions; however, this approach is hampered by low vascular density or permeability. In this study, by exploiting the ability of monocytes to actively penetrate into diseased sites, we designed aptamer-based lipid nanovectors that actively bind onto the surface of monocytes and are released upon reaching the diseased sites. Our method was thoroughly assessed through treating two of the top causes of death in the world, cardiac ischemia-reperfusion injury and pancreatic ductal adenocarcinoma with or without liver metastasis, and showed a significant increase in survival and healing with no toxicity to the liver and kidneys in either case, indicating the success and ubiquity of our platform. We believe that this system provides a new therapeutic method, which can potentially be adapted to treat a myriad of diseases that involve monocyte recruitment in their pathophysiology.


Assuntos
Carcinoma Ductal Pancreático , Cardiopatias , Neoplasias Pancreáticas , Traumatismo por Reperfusão , Carcinoma Ductal Pancreático/patologia , Cardiopatias/metabolismo , Humanos , Monócitos/metabolismo , Neoplasias Pancreáticas/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa