Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Vasc Surg ; 75(2): 651-659.e1, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34509588

RESUMO

BACKGROUND: Endovascular treatment has become the first-line strategy for peripheral arterial disease (PAD). Given the number of procedures required, any technology associated with a reduction in radiation exposure and contrast volume is highly relevant. In the present study, we evaluated whether two-dimensional (2D) fusion imaging could reduce the radiation exposure and contrast volume during endovascular treatment of occlusive PAD. METHODS: Our consecutive, retrospective, single-center, nonrandomized comparative trial included patients with PAD at the femoral, popliteal, and/or tibial level, at any clinical stage, if they were candidates for endovascular revascularization. Patients were treated with or without the EndoNaut 2D fusion imaging system (Therenva, Rennes, France) in a nonhybrid room with the same Cios Alpha mobile C-arm (Siemens, Munich, Germany). The indirect dose-area product and contrast medium volume were recorded. RESULTS: Between March 2018 and April 2020, 255 patients underwent endovascular femoropopliteal revascularization with (n = 124) or without (n = 131) 2D fusion imaging. The volume of injected contrast medium (34.7 ± 13.8 mL vs 51.3 ± 26.7 mL; P < .001) and dose-area product (8.9 ± 9.9 Gy/cm2 vs 13.5 ± 14.0 Gy/cm2; P = .003) were significantly lower for the 2D fusion imaging group than for the control group. A subgroup analysis of complex (TransAtlantic Inter-Society Consensus for the Management of Peripheral Arterial Disease C/D) lesions showed similar results. Stratification of the fusion imaging group into three subgroups, according to the procedure dates, showed no effect of a potential learning curve on the operative parameters. CONCLUSIONS: The results from the present study showed a significant reduction in the contrast volume and radiation dose for endovascular treatment of PAD when applying 2D fusion imaging technology. Overall, a reduction of >30% was observed for both operative parameters, without excessive training requirements, highlighting the potential benefits of using 2D fusion imaging when performing endovascular revascularization for PAD.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Computadores de Mão , Procedimentos Endovasculares/métodos , Artéria Femoral , Imageamento Tridimensional/instrumentação , Doença Arterial Periférica/cirurgia , Cirurgia Assistida por Computador/instrumentação , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Doença Arterial Periférica/diagnóstico , Estudos Retrospectivos
2.
Minim Invasive Ther Allied Technol ; 31(5): 737-746, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34355657

RESUMO

INTRODUCTION: Intra-arterial therapy is an effective way of performing chemotherapy or radiation therapy in patients with primary liver cancer (i.e. hepatocellular carcinoma). Although this minimally invasive approach is now an established treatment option, support tools for pre-operative planning and intra-operative assistance might be helpful. MATERIAL AND METHODS: We developed an approach for semi-automatic segmentation of computed tomography angiography images of the main arterial branches (required for access path to the treatment site), automatic segmentation of the liver, arterial and venous tree, and interactive segmentation of the tumors (required for procedure-specific planning). This approach was then integrated into a liver-specific workflow within EndoSize® solution, a planning software for endovascular procedures. The main branches extraction approach was qualitatively evaluated inside the software, while the automatic segmentation methods were quantitatively assessed. RESULTS: Main branches extraction provides a success rate of 85% (i.e. all arteries correctly extracted) in a dataset of 172 patients. On public databases, a mean DICE of 0.91, 0.47 and 0.92 was obtained for liver, venous and arterial trees segmentation, respectively. CONCLUSIONS: This pipeline is suitable for directly accessing the treatment site, giving anatomic measurements, and visualizing the hepatic trees, liver, and surrounding arteries during the pre-operative planning. ABBREVIATIONS: HCC: hepatocellular carcinoma; TACE: transarterial chemoembolization; SIRT: selective internal radiation therapy; CT: computed tomography; CTA: computed tomography angiography; AMS: superior mesenteric artery; LGA: left gastric artery; RHA: right hepatic artery; LHA: left hepatic artery; rbHA: right branch of the hepatic artery; lbHA: left branch of the hepatic artery; GDA: gastroduodenal artery; VOI: volume of interest; SD: standard deviation; MICCAI: medical image computing and computer assisted interventions; MR: magnetic resonance.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Artéria Hepática , Humanos , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/terapia , Software
3.
Ann Vasc Surg ; 71: 273-279, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32890647

RESUMO

BACKGROUND: Fusion imaging makes it possible to improve endovascular procedures and is mainly used in hybrid rooms for aortic procedures. The objective of this study was to evaluate the feasibility of fusion imaging for femoropopliteal endovascular procedures with a mobile flat plane sensor and dedicated software to assist endovascular navigation. MATERIALS AND METHODS: Between May and December 2017, 41 patients requiring femoropopliteal endovascular revascularization were included. Interventions were carried out in a conventional surgical room equipped with a mobile plane sensor (Cios Alpha, Siemens). The numerical video stream was transmitted to an angionavigation station (EndoNaut (EN), Therenva). The software created an osseous and arterial panorama of the treated limb from the angiographies carried out at the beginning of procedure. After each displacement of the table, the software relocated the current image on the osseous panorama, with 2D-2D resetting, and amalgamated the mask of the arterial panorama. The success rates of creation of osseous and arterial panorama and the success of relocation were evaluated. The data concerning irradiation, the volume of contrast (VC) injected, and operative times were recorded. RESULTS: Osseous panoramas could be automatically generated for the 41 procedures, without manual adjustment in 33 cases (80.5%). About 35 relocations based on a 2D-2D resetting could be obtained in the 41 procedures, with a success rate of 85%. The causes of failure were a change in table height or arch angulation. The average duration of intervention was 74.5 min. The irradiation parameters were duration of fluoroscopy 17.8 ± 13.1 min, air kerma 80.5 ± 68.4 mGy, and dose area product 2140 ± 1599 µGy m2. The average VC was 24.5 ± 14 mL. CONCLUSIONS: This preliminary study showed that fusion imaging is possible in a nonhybrid room for peripheral procedures. Imagery of mobile C-arms can be improved for femoropopliteal endovascular procedures without heavy equipment. These imagery tools bring an operative comfort and could probably reduce irradiation and the injected VC. The clinical benefit must be evaluated in more patients in a randomized comparative study with a rigorous methodology.


Assuntos
Angiografia/instrumentação , Procedimentos Endovasculares/instrumentação , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/instrumentação , Terapia Assistida por Computador/instrumentação , Idoso , Idoso de 80 Anos ou mais , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Salas Cirúrgicas , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Radiografia Intervencionista/efeitos adversos , Software , Fatores de Tempo , Resultado do Tratamento
4.
J Vasc Interv Radiol ; 30(9): 1386-1392, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31155497

RESUMO

PURPOSE: To quantify the displacement of the vascular structures after insertion of stiff devices during endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm and to identify potential parameters influencing this displacement. MATERIALS AND METHODS: A total of 50 patients from a single center undergoing EVAR were prospectively enrolled between January 2016 and December 2017. Fusion imaging was employed using the EndoNaut (Therenva, Rennnes, France) station through a 3-dimensional (3D)/2-dimensional (2D) technology synchronizing the 3D computed tomography scan to the live intraoperative fluoroscopy. The accuracy of the fusion roadmap was evaluated before deployment by conventional digital subtraction angiogram on a single plane (with different C-arm incidences). RESULTS: The mean displacement error of the ostium of the lowest renal artery was 4.1 ± 2.4 mm (range, 0-11.7 mm), with a left/right displacement of 1.6 ± 1.7 mm (range, 0-6.9 mm) and a craniocaudal displacement of 3.5 ± 2.4 mm (range, 0-11.3 mm). The correction required for the ostium of the lower renal artery was mostly cranial and to the left. Multiple linear regression analysis revealed only the sharpest angle between the aneurysm neck and sac as the factor influencing the accuracy of fusion imaging. All other parameters did not show any correlation. CONCLUSIONS: This study identified the sources of fusion error after insertion of rigid material during EVAR. As the sharpest angulation between aneurysm neck and sac increases, the overall accuracy of the fusion might be affected.


Assuntos
Angiografia Digital , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Stents , Resultado do Tratamento
5.
Ann Vasc Surg ; 61: 291-298, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31352087

RESUMO

BACKGROUND: During endovascular aneurysm repair (EVAR), complex iliac anatomy is a source of complications such as unintentional coverage of the hypogastric artery. The aim of our study was to evaluate ability to predict coverage of the hypogastric artery using a biomechanical model simulating arterial deformations caused by the delivery system. METHODS: The biomechanical model of deformation has been validated by many publications. The simulations were performed on 38 patients included retrospectively, for a total of 75 iliac arteries used for the study. On the basis of objective measurements, two groups were formed: one with "complex" iliac anatomy (n = 38 iliac arteries) and the other with "simple" iliac anatomy (n = 37 iliac arteries). The simulation enabled measurement of the lengths of the aorta and the iliac arteries once deformed by the device. Coverage of the hypogastric artery was predicted if the deformed renal/iliac bifurcation length (Lpre) was less than the length of the implanted device (Lstent-measured on the postoperative computed tomography [CT]) and nondeformed Lpre was greater than Lstent. RESULTS: Nine (12%) internal iliac arteries were covered unintentionally. Of the coverage attributed to perioperative deformations, 1 case (1.3%) occurred with simple anatomy and 6 (8.0%) with complex anatomy (P = 0.25). All cases of unintentional coverage were predicted by the simulation. The simulation predicted hypogastric coverage in 35 cases (46.7%). There were therefore 26 (34.6%) false positives. The simulation had a sensitivity of 100% and a specificity of 60.6%. On multivariate analysis, the factors significantly predictive of coverage were the iliac tortuosity index (P = 0.02) and the predicted margin between the termination of the graft limb and the origin of the hypogastric artery in nondeformed (P = 0.009) and deformed (P = 0.001) anatomy. CONCLUSIONS: Numerical simulation is a sensitive tool for predicting the risk of hypogastric coverage during EVAR and allows more precise preoperative sizing. Its specificity is liable to be improved by using a larger cohort.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Simulação por Computador , Procedimentos Endovasculares/efeitos adversos , Artéria Ilíaca/fisiopatologia , Modelos Cardiovasculares , Análise Numérica Assistida por Computador , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Fenômenos Biomecânicos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Feminino , Análise de Elementos Finitos , Humanos , Artéria Ilíaca/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/fisiopatologia , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
6.
Ann Vasc Surg ; 55: 166-174, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30092429

RESUMO

BACKGROUND: Fusion imaging is a technique that facilitates endovascular navigation but is only available in hybrid rooms. The goal of this study was to evaluate the feasibility of fusion imaging with a mobile C-arm in a conventional operating room through the use of an angionavigation station. METHODS: From May 2016 to June 2017, the study included all patients who underwent an aortic stent graft procedure in a conventional operating room with a mobile flat-panel detector (Cios Alpha, Siemens) connected to an angionavigation station (EndoNaut, Therenva). The intention was to perform preoperative 3D computerized tomography/perioperative 2D fluoroscopy fusion imaging using an automatic registration process. Registration was considered successful when the software was able to correctly overlay preoperative 3D vascular structures onto the fluoroscopy image. For EVAR, contrast dose, operation time, and fluoroscopy time (FT) were compared with those of a control group drawn from the department's database who underwent a procedure with a C-arm image intensifier. RESULTS: The study included 54 patients, and the procedures performed were 49 EVAR, 2 TEVAR, 2 IBD, and 1 FEVAR. Of the 178 registrations that were initialized, it was possible to use the fusion imaging in 170 cases, that is, a 95.5% success rate. In the EVAR comparison, there were no difference with the control group (n = 103) for FT (21.9 ± 12 vs. 19.5 ± 13 min; P = 0.27), but less contrast agent was used in the group undergoing a procedure with the angionavigation station (42.3 ± 22 mL vs. 81.2 ± 48 mL; P < 0.001), and operation time was shorter (114 ± 44 vs. 140.8 ± 38 min; P < 0.0001). CONCLUSIONS: Fusion imaging is feasible with a mobile C-arm in a conventional operating room and thus represents an alternative to hybrid rooms. Its clinical benefits should be evaluated in a randomized series, but our study already suggests that EVAR procedures might be facilitated with an angionavigation system.


Assuntos
Aneurisma Aórtico/cirurgia , Aortografia/instrumentação , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada/instrumentação , Procedimentos Endovasculares/instrumentação , Radiografia Intervencionista/instrumentação , Cirurgia Assistida por Computador/instrumentação , Tomógrafos Computadorizados , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/efeitos adversos , Angiografia por Tomografia Computadorizada/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia/instrumentação , Humanos , Masculino , Duração da Cirurgia , Modelagem Computacional Específica para o Paciente , Projetos Piloto , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Cirurgia Assistida por Computador/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
7.
Minim Invasive Ther Allied Technol ; 28(3): 157-164, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30039720

RESUMO

PURPOSE: Minimally invasive trans-catheter aortic valve implantation (TAVI) has emerged as a treatment of choice for high-risk patients with severe aortic stenosis. However, the planning of TAVI procedures would greatly benefit from automation to speed up, secure and guide the deployment of the prosthetic valve. We propose a hybrid approach allowing the computation of relevant anatomical measurements along with an enhanced visualization. MATERIAL AND METHODS: After an initial step of centerline detection and aorta segmentation, model-based and statistical-based methods are used in combination with 3 D active contour models to exploit the complementary aspects of these methods and automatically detect aortic leaflets and coronary ostia locations. Important anatomical measurements are then derived from these landmarks. RESULTS: A validation on 50 patients showed good precision with respect to expert sizing for the ascending aorta diameter calculation (2.2 ± 2.1 mm), the annulus diameter (1.31 ± 0.75 mm), and both the right and left coronary ostia detection (1.96 ± 0.87 mm and 1.80 ± 0.74 mm, respectively). The visualization is enhanced thanks to the aorta and aortic root segmentation, the latter showing good agreement with manual expert delineation (Jaccard index: 0.96 ± 0.03). CONCLUSION: This pipeline is promising and could greatly facilitate TAVI planning.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta/cirurgia , Automação , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino
8.
J Vasc Surg ; 65(6): 1830-1838, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28359714

RESUMO

OBJECTIVE: Sac shrinkage is considered a reliable surrogate marker of success after endovascular aneurysm repair (EVAR). Whereas sac shrinkage is the best expected outcome, predictive factors of sac shrinkage remain unclear. The aim of this study was to identify the role of preoperative and postoperative influencing factors of sac reduction after EVAR. METHODS: Online searches across MEDLINE, Embase, and Cochrane Library medical databases were simultaneously performed. Study effects were pooled using a random-effects model, and forest plots were generated for every potential influencing factor. RESULTS: A total of 24 studies with 14,754 patients were included (mean age, 73.4 years; 76% male). At a mean follow-up of 24 months, the pooled shrinkage proportion was 47%. Random-effects meta-analysis revealed that renal impairment (odds ratio [OR], 0.74; 95% confidence interval [CI], 0.57-0.96), type I endoleaks (OR, 0.17; 95% CI, 0.08-0.39), type II endoleaks (OR, 0.21; 95% CI, 0.14-0.33), and combined type I and type II endoleaks (OR, 0.32; 95% CI, 0.22-0.47) were found to prevent sac shrinkage, whereas hypercholesterolemia (OR, 1.24; 95% CI, 1.02-1.51) and smoking (OR, 1.32; 95% CI, 1.17-1.49) have a significant positive impact on sac shrinkage. In addition, there was a trend toward the association between shrinkage and statin therapy (OR, 4.07; 95% CI, 1.02-16.32) and nearly significant negative impacts of coronary artery disease (OR, 0.84; 95% CI, 0.70-1.01), diabetes (OR, 0.79; 95% CI, 0.60-1.04), and sac thrombus (OR, 0.88; 95% CI, 0.77-1.01) on sac shrinkage. CONCLUSIONS: In this large meta-analysis of patients undergoing EVAR, we found that several comorbidity and postoperative factors were associated with postoperative sac shrinkage. These findings may contribute to a better understanding of the shrinkage process of patients undergoing EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Comorbidade , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Razão de Chances , Indução de Remissão , Fatores de Risco , Resultado do Tratamento
9.
Ann Vasc Surg ; 41: 284-293, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27903482

RESUMO

BACKGROUND: Type II endoleaks (T2Es) remain the Achilles heel of endovascular aneurysm repair (EVAR), involving a close follow-up and sometimes leading to reintervention. Identifying risk factors impacting T2Es is of concern to improve decision making and optimize follow-up. However, it has led to contradictory results, with supporting evidence for the majority of factors being weak. METHODS: A systematic review and meta-analysis was conducted to study risk factors of T2Es following EVAR to identify risk factors and measure their dedicated strength of association. Using a literature search of MEDLINE, EMBASE, and the Cochrane Library, 31 retrospective studies including a total of 15,793 patients were identified and fulfilled the strict specified inclusion criteria. Random-effects meta-analysis was conducted for each factor to combine effect estimate across studies. A total of 21 factors related to demography, preoperative treatment, comorbidity, and morphology were statistically pooled. RESULTS: On the basis of the pooled odds ratios and their 95% confidence intervals, patency of aortic side branches, represented by the patency of the inferior mesenteric artery, lumbar arteries, or total number of aortic side branches, were found to be significant harmful risk factors of T2Es. Women were also found to have nearly significant higher risk of developing T2Es than men. On the contrary, the following were found to have a significant protective role: smoking, peripheral artery disease, and thrombus load, represented by the maximum thickness at the maximum aneurysm diameter, the presence of circumferential thrombus, or the presence of thrombus at the level of inferior mesenteric artery. CONCLUSION: Identifying significant risk factors of development of T2Es is mandatory to improve decision making and optimize surveillance planning in EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Aneurisma da Aorta Abdominal/fisiopatologia , Endoleak/fisiopatologia , Feminino , Humanos , Modelos Logísticos , Masculino , Razão de Chances , Medição de Risco , Fatores de Risco , Resultado do Tratamento
10.
Ann Vasc Surg ; 40: 19-27, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27903486

RESUMO

BACKGROUND: The risk of long-term complications after endovascular aneurysm repair (EVAR) is still higher than open surgery and is a critical issue. This study aims to make available reliable statistical predictive models of complications after EVAR. METHODS: Two hundred and thirteen patients who underwent EVAR between 2002 and 2012 were included in this study. The preoperative computed tomography scans were analyzed with a dedicated workstation to provide spatially correct 3-dimensional data. Age, gender, operation-related factors, and 21 morphologic variables were measured and included in the analyses. Five postoperative outcomes were studied. After an initial selection of predictors based on univariate analysis, binomial logistic regression models were proposed for each outcome. The ability to predict each outcome was assessed with receiver operating characteristic curves considering that an area under the curve (AUC) > 0.70 is generally considered sufficiently accurate. RESULTS: The mean age was 74.8 ± 8.6 years with a mean follow-up of 43.8 ± 22.1 months. Respectively, rates and risk factors of each outcome were 25.3% (n = 51) for abdominal aortic aneurysm (AAA) enlargement (age, number of patent sac branches, iliac calcifications and tortuosity, aneurysmal thrombus), 7% (n = 15) for type IA endoleak (neck calcification and AAA diameter), 3.7% (n = 8) for type IB endoleak (iliac tortuosity, AAA diameter, neck thrombus), 19.8% (n = 40) for type II endoleak (female, number of patent sac branches), and 25.9% (n = 55) for reintervention from any cause (neck calcification). The risk associated to each outcome can be calculated with a combination of these different preoperative variables. AUC for each outcome were 79.6% for AAA enlargement, 70.4% for reintervention, 81.3% for type IA endoleak, 92.3% for type IB endoleak, 70.6% for type II endoleak. CONCLUSIONS: This study shows that an exhaustive description of the preoperative anatomy before EVAR is a powerful and reliable tool to predict the risk of developing the most common complications after EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Área Sob a Curva , Distribuição de Qui-Quadrado , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/etiologia
11.
Hum Brain Mapp ; 35(9): 4330-44, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24652699

RESUMO

Subthalamic nucleus (STN) deep brain stimulation (DBS) is an effective surgical therapy to treat Parkinson's disease (PD). Conventional methods employ standard atlas coordinates to target the STN, which, along with the adjacent red nucleus (RN) and substantia nigra (SN), are not well visualized on conventional T1w MRIs. However, the positions and sizes of the nuclei may be more variable than the standard atlas, thus making the pre-surgical plans inaccurate. We investigated the morphometric variability of the STN, RN and SN by using label-fusion segmentation results from 3T high resolution T2w MRIs of 33 advanced PD patients. In addition to comparing the size and position measurements of the cohort to the Talairach atlas, principal component analysis (PCA) was performed to acquire more intuitive and detailed perspectives of the measured variability. Lastly, the potential correlation between the variability shown by PCA results and the clinical scores was explored.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/patologia , Núcleo Rubro/patologia , Substância Negra/patologia , Núcleo Subtalâmico/patologia , Atlas como Assunto , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos , Análise de Componente Principal
12.
Mov Disord ; 29(14): 1781-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25382049

RESUMO

Several hypotheses have been put forward to explain weight gain after deep brain stimulation (DBS), but none provides a fully satisfactory account of this adverse effect. We analyzed the correlation between changes in brain metabolism (using positron emission tomography [PET] imaging) and weight gain after bilateral subthalamic nucleus DBS in patients with Parkinson's disease. Body mass index was calculated and brain activity prospectively measured using 2-deoxy-2[18F]fluoro-D-glucose 3 months before and 4 months after the start of subthalamic nucleus deep brain stimulation in 23 patients with Parkinson's disease. Motor complications (United Parkinson's Disease Rating Scale [UPDRS]-IV scores) and dopaminergic medication were included in the analysis to control for their possible influence on brain metabolism. Mean ± standard deviation (SD) body mass index increased significantly by 0.8 ± 1.5 kg/m(2) (P = 0.03). Correlations were found between weight gain and changes in brain metabolism in limbic and associative areas, including the orbitofrontal cortex (Brodmann areas [BAs] 10 and 11), lateral and medial parts of the temporal lobe (BAs 20, 21, 22,39 and 42), anterior cingulate cortex (BA 32), and retrosplenial cortex (BA 30). However, we found no correlation between weight gain and metabolic changes in sensorimotor areas. These findings suggest that changes in associative and limbic processes contribute to weight gain after subthalamic nucleus DBS in Parkinson's disease.


Assuntos
Estimulação Encefálica Profunda , Tomografia por Emissão de Pósitrons , Núcleo Subtalâmico/fisiologia , Aumento de Peso/fisiologia , Índice de Massa Corporal , Córtex Cerebral/metabolismo , Estimulação Encefálica Profunda/métodos , Glucose/metabolismo , Humanos , Doença de Parkinson/metabolismo , Doença de Parkinson/terapia , Tomografia por Emissão de Pósitrons/métodos
13.
J Biomed Inform ; 46(5): 822-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23810856

RESUMO

Surgical Process Modelling (SPM) was introduced to improve understanding the different parameters that influence the performance of a Surgical Process (SP). Data acquired from SPM methodology is enormous and complex. Several analysis methods based on comparison or classification of Surgical Process Models (SPMs) have previously been proposed. Such methods compare a set of SPMs to highlight specific parameters explaining differences between populations of patients, surgeons or systems. In this study, procedures performed at three different international University hospitals were compared using SPM methodology based on a similarity metric focusing on the sequence of activities occurring during surgery. The proposed approach is based on Dynamic Time Warping (DTW) algorithm combined with a clustering algorithm. SPMs of 41 Anterior Cervical Discectomy (ACD) surgeries were acquired at three Neurosurgical departments; in France, Germany, and Canada. The proposed approach distinguished the different surgical behaviors according to the location where surgery was performed as well as between the categorized surgical experience of individual surgeons. We also propose the use of Multidimensional Scaling to induce a new space of representation of the sequences of activities. The approach was compared to a time-based approach (e.g. duration of surgeries) and has been shown to be more precise. We also discuss the integration of other criteria in order to better understand what influences the way the surgeries are performed. This first multi-site study represents an important step towards the creation of robust analysis tools for processing SPMs. It opens new perspectives for the assessment of surgical approaches, tools or systems as well as objective assessment and comparison of surgeon's expertise.


Assuntos
Modelos Biológicos , Procedimentos Neurocirúrgicos , Análise por Conglomerados , Humanos
14.
J Biomed Inform ; 45(2): 255-64, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22120773

RESUMO

In the creation of new computer-assisted intervention systems, Surgical Process Models (SPMs) are an emerging concept used for analyzing and assessing surgical interventions. SPMs represent Surgical Processes (SPs) which are formalized as symbolic structured descriptions of surgical interventions using a pre-defined level of granularity and a dedicated terminology. In this context, one major challenge is the creation of new metrics for the comparison and the evaluation of SPs. Thus, correlations between these metrics and pre-operative data are used to classify surgeries and highlight specific information on the surgery itself and on the surgeon, such as his/her level of expertise. In this paper, we explore the automatic classification of a set of SPs based on the Dynamic Time Warping (DTW) algorithm. DTW is used to compute a similarity measure between two SPs that focuses on the different types of activities performed during surgery and their sequencing, by minimizing time differences. Indeed, it turns out to be a complementary approach to the classical methods that only focus on differences in the time and the number of activities. Experiments were carried out on 24 lumbar disk herniation surgeries to discriminate the surgeons level of expertise according to a prior classification of SPs. Supervised and unsupervised classification experiments have shown that this approach was able to automatically identify groups of surgeons according to their level of expertise (senior and junior), and opens many perspectives for the creation of new metrics for comparing and evaluating surgeries.


Assuntos
Algoritmos , Deslocamento do Disco Intervertebral/cirurgia , Competência Clínica , Humanos , Informática Médica , Modelos Anatômicos , Cirurgia Assistida por Computador/métodos
15.
Stud Health Technol Inform ; 173: 78-84, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22356962

RESUMO

In image-guided surgery, a new generation of Computer-Assisted-Surgical (CAS) systems based on information from the Operating Room (OR) has recently been developed to improve situation awareness in the OR. Our main project is to develop an application-dependant framework able to extract high-level tasks (surgical phases) using microscope videos data only. In this paper, we present two methods: one method to segment the pupil and one to extract and recognize surgical tools. We show how both methods improve the accuracy of the framework for analysis of cataract surgery videos, to detect eight surgical phases.


Assuntos
Extração de Catarata , Pupila , Cirurgia Assistida por Computador/métodos , Instrumentos Cirúrgicos , Alemanha , Humanos , Microscopia de Vídeo
16.
Int J Comput Assist Radiol Surg ; 17(7): 1281-1288, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35486303

RESUMO

PURPOSE: Endovascular revascularization is becoming the established first-line treatment of peripheral artery disease (PAD). Ultrasound (US) imaging is used pre-operatively to make the first diagnosis and is often followed by a CT angiography (CTA). US provides a non-invasive and non-ionizing method for the visualization of arteries and lesion(s). This paper proposes to generate a 3D stretched reconstruction of the femoral artery from a sequence of 2D US B-mode frames. METHODS: The proposed method is solely image-based. A Mask-RCNN is used to segment the femoral artery on the 2D US frames. In-plane registration is achieved by aligning the artery segmentation masks. Subsequently, a convolutional neural network (CNN) predicts the out-of-plane translation. After processing all input frames and re-sampling the volume according to the vessel's centerline, the whole femoral artery can be visualized on a single slice of the resulting stretched view. RESULTS: 111 tracked US sequences of the left or right femoral arteries have been acquired on 18 healthy volunteers. fivefold cross-validation was used to validate our method and achieve an absolute mean error of 0.28 ± 0.28 mm and a median drift error of 8.98%. CONCLUSION: This study demonstrates the feasibility of freehand US stretched reconstruction following a deep learning strategy for imaging the femoral artery. Stretched views are generated and can give rich diagnosis information in the pre-operative planning of PAD procedures. This visualization could replace traditional 3D imaging in the pre-operative planning process, and during the pre-operative diagnosis phase, to identify, locate, and size stenosis/thrombosis lesions.


Assuntos
Imageamento Tridimensional , Doença Arterial Periférica , Artérias , Angiografia por Tomografia Computadorizada , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Redes Neurais de Computação , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Ultrassonografia/métodos
17.
J Cardiovasc Transl Res ; 15(2): 427-437, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34448116

RESUMO

The aim of this study is to develop an automated deep-learning-based whole heart segmentation of ECG-gated computed tomography data. After 21 exclusions, CT acquired before transcatheter aortic valve implantation in 71 patients were reviewed and randomly split in a training (n = 55 patients), validation (n = 8 patients), and a test set (n = 8 patients). A fully automatic deep-learning method combining two convolutional neural networks performed segmentation of 10 cardiovascular structures, which was compared with the manually segmented reference by the Dice index. Correlations and agreement between myocardial volumes and mass were assessed. The algorithm demonstrated high accuracy (Dice score = 0.920; interquartile range: 0.906-0.925) and a low computing time (13.4 s, range 11.9-14.9). Correlations and agreement of volumes and mass were satisfactory for most structures. Six of ten structures were well segmented. Deep-learning-based method allowed automated WHS from ECG-gated CT data with a high accuracy. Challenges remain to improve right-sided structures segmentation and achieve daily clinical application.


Assuntos
Aprendizado Profundo , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X
18.
Neuroimage ; 49(1): 345-54, 2010 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-19682582

RESUMO

New MR imaging protocols enable visualization of brain structures. However, for dedicated clinical applications such as targeting deep brain stimulation (DBS), a more accurate localization requires the use of atlases. We developed a three-dimensional digitized mono-subject anatomical template of the human brain based on 3-T magnetic resonance images (MRI). By averaging 15 registered T1 image acquisitions, we have shown that the final image corresponds to an optimal image, limited by the performance of the 3-T MR machine. We compared different preprocessing workflows for template construction. With the optimal strategy, along with validated existing processing methods, one T1 template and one T1-T2 mixing template were created in order to improve visualization of spatially complex deep structures. Reduction of voxel size to 0.25 mm(3) was also advantageous to observe fine structures and white matter/gray matter intensity crossings. Results demonstrated that such a template also improved inter-patient registration for population comparison in DBS. These MR templates are made freely available to our community (http://www.vmip.org/mritemplate) to serve as a reference for neuroimage processing methods.


Assuntos
Encéfalo/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Gânglios da Base/anatomia & histologia , Estimulação Encefálica Profunda , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Dinâmica não Linear , Reprodutibilidade dos Testes
19.
Int J Comput Assist Radiol Surg ; 15(11): 1881-1894, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32870445

RESUMO

PURPOSE: The fusion of pre/intraoperative images may improve catheter manipulation during radioembolization (RE) interventions by adding relevant information. The objective of this work is to propose and evaluate the performance of a RE guidance strategy relying on structure-driven intensity-based registration between preoperative CTA and intraoperative X-ray images. METHODS: The navigation strategy is decomposed into three image fusion steps, supporting the catheter navigation from the femoral artery till reaching the injection site (IS). During the pretreatment assessment intervention, the aorta and the origins of its side branches are projected on the intraoperative 2D fluoroscopy following a 3D/2D bone-based registration process, to assist the celiac trunk access. Subsequently, a similar approach consisting in projecting the hepatic vasculature on intraoperative DSA through 3D/2D vessel-based registration is performed to assist the IS location. Lastly, the selected IS is reproduced during the treatment intervention by employing 2D/2D image-based registration between pretreatment and treatment fluoroscopic images. RESULTS: The three fusion steps were independently evaluated on subsets of 20, 19 and 5 patient cases, respectively. Best results were obtained with gradient difference as similarity measure and with a delimited preoperative vascular structure for vessel-based registration. The approach resulted in qualitatively appropriate anatomical correspondences when projecting the preoperative structures on intraoperative images. With the best configuration, the registration steps showed accuracy and feasibility in aligning data, with global mean landmarks errors of 1.59 mm, 2.32 mm and 2.17 mm, respectively, a computation time that never exceeded 5 s, 25 s and 11 s, respectively, and a user interaction limited to manual initialization of the 3D/2D registration. CONCLUSION: An image fusion-based approach has been specifically proposed for RE procedures guidance. The catheter manipulation strategy based on the fusion of pre- and intraoperative images has the potential to support different steps of the RE clinical workflow and to guide the overall procedure.


Assuntos
Embolização Terapêutica/métodos , Fluoroscopia/métodos , Neoplasias Hepáticas/terapia , Fígado/cirurgia , Catéteres , Estudos de Viabilidade , Humanos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem
20.
PLoS One ; 15(9): e0238463, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32881919

RESUMO

In a clinical decision support system, the purpose of case-based reasoning is to help clinicians make convenient decisions for diagnoses or interventional gestures. Past experience, which is represented by a case-base of previous patients, is exploited to solve similar current problems using four steps-retrieve, reuse, revise, and retain. The proposed case-based reasoning has been focused on transcatheter aortic valve implantation to respond to clinical issues pertaining vascular access and prosthesis choices. The computation of a relevant similarity measure is an essential processing step employed to obtain a set of retrieved cases from a case-base. A hierarchical similarity measure that is based on a clinical decision tree is proposed to better integrate the clinical knowledge, especially in terms of case representation, case selection and attributes weighting. A case-base of 138 patients is used to evaluate the case-based reasoning performance, and retrieve- and reuse-based criteria have been considered. The sensitivity for the vascular access and the prosthesis choice is found to 0.88 and 0.94, respectively, with the use of the hierarchical similarity measure as opposed to 0.53 and 0.79 for the standard similarity measure. Ninety percent of the suggested solutions are correctly classified for the proposed metric when four cases are retrieved. Using a dedicated similarity measure, with relevant and weighted attributes selected through a clinical decision tree, the set of retrieved cases, and consequently, the decision suggested by the case-based reasoning are substantially improved over state-of-the-art similarity measures.


Assuntos
Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Algoritmos , Valva Aórtica/fisiologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Sistemas de Apoio a Decisões Clínicas , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Seleção de Pacientes , Resolução de Problemas , Desenho de Prótese , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa