RESUMO
Photorefractive keratectomy was performed at three centers using the 193-nm excimer laser on 31 sighted myopic eyes. Preoperative refractive errors (spherical equivalent) ranged from -12.00 to -4.00 diopters (D) (mean, -6.49 +/- 1.75 D). Peribulbar anesthesia, a 5.2- to 6.0-mm beam diameter, and topical corticosteroids were used for up to 6 months after surgery. The epithelium healed within 3 to 4 days, and all patients returned to their best corrected visual acuity within 1 line of their preoperative acuity. There was minimal subepithelial reticular haze, peaking at 3 weeks and diminishing over the next 3 to 4 months, which was not felt to be visually significant. At 6 months, the average residual refractive error was -1.85 +/- 2.5 D. Sixty-eight percent of eyes were corrected within 2 D and 55% within 1 D of attempted correction. There was no significant change in astigmatism, contrast sensitivity, corneal sensation, or endothelial cell counts. This preliminary work shows that photorefractive keratectomy has promise in the reduction of moderate myopia.
Assuntos
Córnea/cirurgia , Terapia a Laser , Miopia/cirurgia , Adulto , Contagem de Células , Sensibilidades de Contraste , Córnea/fisiologia , Endotélio Corneano/citologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Complicações Pós-Operatórias , Refração Ocular , Acuidade Visual , CicatrizaçãoRESUMO
We reviewed the outcome in 115 patients who underwent penetrating keratoplasty and transscleral fixation of a posterior chamber lens. One patient died soon after surgical procedures, and nine patients were lost to follow-up, leaving a cohort of 105 patients. Mean follow-up time was 26.8 months (range, six to 43 months). Visual acuity of 20/40 or better was found in 29 patients (27.6%) and 20/50 to 20/200 in 37 patients (35.2%). Reasons for poor visual outcome included cystoid macular edema in ten patients (9.5%), age-related macular degeneration in six patients (5.7%), and retinal detachment in four patients (3.8%). None of the patients developed lens decentration. There were no instances of hyphema and only one patient had a perioperative limited suprachoroidal hemorrhage. New-onset increase in intraocular pressure developed in 20 of 66 patients (30.3%). Analysis of the 39 patients with preoperative increase in intraocular pressure that required medical treatment demonstrated an improvement in 13 patients (33.3%), worsening in 12 patients (30.8%), and unchanged status in 14 patients (35.9%). The exposed haptic suture was covered by using one of the following three alternative methods: a conjunctival flap, a scleral flap, or a corneal tissue button. Exposure of the haptic suture through the conjunctiva was a complication in 21 patients (20%). Of these 16 (76.1%) occurred in the group with a conjunctival covering, five (23.8%) occurred in the group with a scleral flap, and none occurred in the corneal tissue button group. This study demonstrated that transscleral fixation of a posterior chamber lens is a viable option in the treatment of patients undergoing penetrating keratoplasty and intraocular lens implantation with absent capsular support.
Assuntos
Ceratoplastia Penetrante , Lentes Intraoculares , Esclera/cirurgia , Técnicas de Sutura , Adulto , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Resultado do Tratamento , Acuidade VisualRESUMO
The Brown-McLean syndrome is a clinical condition with corneal edema involving the peripheral 2 to 3 mm of the cornea. The edema typically starts inferiorly and progresses circumferentially, but spares the central portion of the cornea. Additionally, the edema is associated with a punctate orange-brown pigmentation on the endothelium underlying the edematous areas. Central cornea guttata is frequently seen. This condition occurs most frequently after intracapsular cataract extraction, but may also occur after extracapsular cataract extraction and phacoemulsification, or pars plana lensectomy and vitrectomy. Surgical complications and multiple intraocular procedures are frequently observed in these patients. Less frequently, the Brown-McLean syndrome can occur in eyes that have not had surgery. We studied the clinical characteristics of 43 affected eyes of 32 patients. New findings included Brown-McLean syndrome occurring in two eyes of a phakic patient with intermittent angle-closure glaucoma. Two eyes developed Brown-McLean syndrome after phacoemulsification and one eye developed peripheral edema after pars plana vitrectomy and lensectomy. Additionally, severe, infectious keratitis occurred after rupture of peripheral bullae in two eyes. Patients with this condition should be examined periodically and educated regarding the early clinical signs of corneal ulceration.
Assuntos
Edema da Córnea/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Extração de Catarata , Edema da Córnea/etiologia , Endotélio Corneano/patologia , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/complicações , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Síndrome , VitrectomiaRESUMO
As part of a clinical trial, photorefractive keratectomy using the VISX 2015 193-nm excimer laser was performed on 91 healthy eyes of 91 patients. Preoperative refractive errors (spherical equivalent) ranged from -1.00 to -7.50 diopters (mean, -4.16 +/- 1.41 diopters). No patient had more than 1 diopter of refractive astigmatism. Six months postoperatively, the average residual refractive error was +0.09 +/- 0.63 diopters (range, -2.13 to +1.63 diopters). Correction within 1 diopter of that attempted was attained in 85 eyes (93%). Uncorrected visual acuity of 20/40 or better was attained in 86 eyes (95%) and was 20/25 or better in 67 eyes (74%). At one year, follow-up information was available on 85 eyes of 85 patients. The average residual refractive error was -0.15 +/- 0.65 diopters (range, -2.50 to +1.63 diopters). Correction within 1 diopter of that attempted was attained in 85 eyes (93%). Uncorrected visual acuity was 20/40 or better in 83 eyes (98%) and was 20/25 or better in 68 eyes (80%). One patient lost three lines of best-corrected visual acuity because of corneal haze, dropping from 20/15 to 20/30, whereas all other patients returned to best-corrected visual acuity within one line of their preoperative best-corrected visual acuity. Photorefractive keratectomy with the 193-nm excimer laser appears to be a useful treatment modality for the reduction of mild to moderate myopia.
Assuntos
Córnea/cirurgia , Terapia a Laser , Miopia/cirurgia , Adolescente , Adulto , Córnea/fisiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Resultado do Tratamento , Acuidade VisualRESUMO
PURPOSE: To evaluate the safety and preliminary efficacy of a novel visual prosthetic device, the Implantable Miniature Telescope, IMT (by Dr Isaac Lipshitz) (IMT), in a phase I trial in patients with significant bilateral central vision impairment from late-stage age-related macular degeneration (AMD). The IMT is designed to reduce the relative size of the scotoma by rendering enlarged (threefold) central visual field images over the central and peripheral retina. DESIGN: Prospective, multicenter, open-label clinical trial. METHODS: In this prospective, multicenter phase I trial, 14 patients aged 60 or older with bilateral geographic atrophy or disciform scar AMD, cataract, and best-corrected visual acuity (BCVA) between 20/80 and 20/400 had an IMT implanted in one eye. Distance and near BCVA, endothelial cell density, and quality of life, measured as activities of daily life (ADL), were evaluated preoperatively and postoperatively. RESULTS: At 12 months, 10 (77%) of 13 patients gained 2 more lines of either distance or near BCVA, and eight (62%) of 13 patients gained 3 or more lines in either distance or near BCVA. Mean endothelial cell density decreased by 13%. All adverse events resolved without sequelae. ADL scores improved in the majority of patients. CONCLUSION: The results of this phase I trial support further evaluation of the IMT in a larger study population with late-stage AMD. A phase II/III trial is in progress.
Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Degeneração Macular/cirurgia , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Contagem de Células , Endotélio Corneano/patologia , Feminino , Humanos , Complicações Intraoperatórias , Degeneração Macular/complicações , Masculino , Óptica e Fotônica/instrumentação , Complicações Pós-Operatórias , Estudos Prospectivos , Qualidade de Vida , Segurança , Transtornos da Visão/etiologia , Transtornos da Visão/cirurgia , Acuidade Visual , Campos VisuaisRESUMO
A 45-year-old man was struck in the left eye by the edge of a paper shopping bag 3 weeks after having laser in situ keratomileusis (LASIK). The injury resulted in partial displacement of the LASIK flap. The patient developed diffuse lamellar keratitis (DLK) the day after the flap was repositioned. By day 4, visual acuity diminished to 20/60. By day 9, the clinical evidence of the DLK had resolved, and by day 15, uncorrected visual acuity was 20/20. Eye trauma 3 weeks after LASIK can result in displacement of the LASIK flap, and DLK can develop following flap replacement. Long-term anatomic and visual results are usually good.
Assuntos
Substância Própria/lesões , Traumatismos Oculares/complicações , Ceratite/etiologia , Ceratomileuse Assistida por Excimer Laser In Situ , Retalhos Cirúrgicos , Deiscência da Ferida Operatória/etiologia , Ferimentos não Penetrantes/complicações , Substância Própria/cirurgia , Humanos , Ceratite/cirurgia , Masculino , Pessoa de Meia-Idade , Reoperação , Deiscência da Ferida Operatória/cirurgia , Acuidade VisualRESUMO
We compared the effect of Occucoat (2% hydroxypropylmethyl-cellulose), Viscoat (sodium hyaluronate-chondroitin sulfate), and Healon (sodium hyaluronate) on postoperative intraocular pressure (IOP) and endothelial cell damage. One hundred fourteen patients having planned extracapsular cataract extraction with posterior chamber lens implantation using a viscomaterial were prospectively randomized into one of five groups. Group I received Occucoat which was removed from the anterior chamber at the conclusion of surgery. Group II received Occucoat which was not removed (retained). Group III received Viscoat which was removed, Group IV received Viscoat which was retained, and Group V received Healon which was removed. No prophylactic ocular hypotensive medications were given. Intraocular pressure was measured at four hours, 24 hours, one week, one month, three months, and one year postoperatively. Compared to preoperative IOP, all groups had a significant IOP increase at four hours. All but the Viscoat removed group (Group III) showed a statistically significant increase at 24 hours postoperatively (P less than .05). No group had a significant increase at one week or later. Specular microscopy showed no significant difference in cell loss between any of the groups at three months or within each group when compared to preoperative cell counts (P greater than .1).
Assuntos
Extração de Catarata , Condroitina/uso terapêutico , Endotélio Corneano/citologia , Ácido Hialurônico/uso terapêutico , Pressão Intraocular/efeitos dos fármacos , Metilcelulose/análogos & derivados , Contagem de Células/efeitos dos fármacos , Condroitina/administração & dosagem , Sulfatos de Condroitina , Combinação de Medicamentos , Humanos , Ácido Hialurônico/administração & dosagem , Derivados da Hipromelose , Lentes Intraoculares , Metilcelulose/administração & dosagem , Metilcelulose/uso terapêutico , Soluções Oftálmicas/uso terapêutico , Estudos Prospectivos , Distribuição AleatóriaRESUMO
As part of a Phase III clinical trial, photorefractive keratectomy using the VISX 2015 193 nm excimer laser was performed on 91 sighted eyes of 91 patients. Preoperative refractive errors (spherical equivalent) ranged from -1.00 diopters (D) to -7.50 D (mean -4.11 D +/- 1.43 D). At six months, average residual refractive error was 0.02 D +/- 0.64 D (range -2.21 D to +1.38 D). Ninety-three percent of eyes were within 1.00 D of attempted correction, 93% had uncorrected visual acuity of 20/40 or better, and 72% achieved uncorrected visual acuity of 20/25 or better. All patients returned to their best corrected visual acuity within one line of their preoperative best corrected visual acuity. Photorefractive keratectomy with the 193 nm excimer laser appears to be useful in reducing low to moderate myopia.
Assuntos
Córnea/cirurgia , Terapia a Laser , Miopia/cirurgia , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/classificação , Miopia/patologia , Complicações Pós-Operatórias , Prognóstico , Acuidade VisualRESUMO
Ovoid intraocular lenses (IOLs) accounted for approximately 35% of the lenses implanted in 1991. Despite their popularity among surgeons, patient observations and complaints suggest that ovoid lenses are associated with undesired optical images postoperatively. A pilot clinical study was carried out to test that hypothesis. A multicentered investigation of 289 cases with well-centered IOLs determined that 45% of 168 patients with ovoid lenses observed unwanted optical phenomena at some time after surgery, whereas 17% of 121 patients with round IOLs had similar complaints. Based upon the preliminary clinical study a laboratory investigation was designed to assess optical performance differences between ovoid and round IOLs. One testing system used scatterometry and a second, ray tracing analysis. Both methods determined that the truncated, thickened edge of ovoid lenses was associated with significant light scattering, possibly accounting for the extraneous light images observed by some patients. The results of the clinical and laboratory investigations suggest that undesired optical images produced by ovoid IOLs are due to lens shape rather than to the reduced dimension of the optic.
Assuntos
Lentes Intraoculares/efeitos adversos , Desenho de Prótese/efeitos adversos , Espalhamento de Radiação , Transtornos da Visão/etiologia , Extração de Catarata , Humanos , Incidência , Luz , Metilmetacrilato , Metilmetacrilatos , Óptica e Fotônica , Projetos Piloto , Estudos Retrospectivos , Inquéritos e QuestionáriosRESUMO
PURPOSE: To evaluate the long-term safety and efficacy of transsclerally sutured posterior chamber lenses in penetrating keratoplasty. METHODS: This was a retrospective review of 130 patients who underwent penetrating keratoplasty and placement of a transsclerally sutured posterior chamber lens with at least 1 year of follow-up. The mean follow-up period was 38.8 months. There were 61 patients who had been followed for at least 3 years (mean, 59 months). RESULTS: At follow-up the visual acuity was 20/40 or better in 40 patients (31%) and 20/50 to 20/200 in 48 patients (36%). The primary reasons for decreased visual acuity were age-related macular degeneration (18%) and graft failure (13%). New-onset glaucoma was found in 19 of 82 patients (23%). In the 48 patients who had elevated intraocular pressures preoperatively, the pressure improved in 13 patients (27%) and worsened in 12 patients (25%). Exposure of the haptic suture through the conjunctiva occurred in 14 patients (11%) at an average of 12 months after surgery. Of these, seven (19%) occurred in patients with conjunctival flaps, and seven (16%) in patients who had scleral flaps covering the haptic suture. No erosions occurred in the cases in which the suture was rotated inside the eye. CONCLUSION: Improvements in the surgical technique have made transsclerally sutured posterior chamber lenses safer in patients with inadequate capsular support. The long-term visual results in penetrating keratoplasty are acceptable and comparable to those of other techniques.
Assuntos
Ceratoplastia Penetrante , Implante de Lente Intraocular/métodos , Esclera/cirurgia , Técnicas de Sutura , Adulto , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Resultado do Tratamento , Acuidade VisualRESUMO
Twenty-four pair of eyes donated to the Minnesota Lions Eye Bank were studied to determine the effect of corneal procurement methods on tissue quality. Eyes studied were ineligible for transplantation because of a preexisting medical condition other than sepsis or age of > 75 years. The procurement technique was randomized for each donor. One cornea was procured in situ (IS), whereas the fellow eye was enucleated and processed in the laboratory (EN). Procurement protocols were standard Eye Bank Association of America methods. Tissue characteristics were scored according to standard eye bank protocols. Cultures were performed at the time of tissue procurement and following storage for 7 days in Dexol media. With the exception of endothelial striae, no statistical difference was found between groups for any tissue characteristics. The average score for endothelial striae in the IS group was greater than twice that of the EN group. Initial cultures were positive in 10 of 24 in the IS group and four of 24 in the EN group. Each group had three positive end-storage cultures. These results demonstrate superior tissue decontamination after initial processing and less endothelial cell trauma with standard enucleation when compared to in situ corneal excisions.
Assuntos
Córnea , Enucleação Ocular , Infecções Oculares Bacterianas/etiologia , Traumatismos Oculares/etiologia , Obtenção de Tecidos e Órgãos , Idoso , Bactérias/isolamento & purificação , Córnea/microbiologia , Córnea/patologia , Lesões da Córnea , Endotélio Corneano/patologia , Bancos de Olhos , Enucleação Ocular/efeitos adversos , Enucleação Ocular/métodos , Humanos , Estudos Prospectivos , Doadores de TecidosAssuntos
Córnea/cirurgia , Oftalmologia/normas , Procedimentos Cirúrgicos Refrativos , Transplante de Córnea/normas , Transplante de Córnea/tendências , Controle de Custos , Humanos , Ceratotomia Radial/normas , Ceratotomia Radial/tendências , Lasers de Excimer , Oftalmologia/tendências , Ceratectomia Fotorrefrativa/normas , Ceratectomia Fotorrefrativa/tendências , Erros de Refração/economiaAssuntos
Córnea/cirurgia , Polímeros , Próteses e Implantes , Sulfonas , Animais , Córnea/patologia , Desenho de Equipamento , HumanosAssuntos
Córnea/cirurgia , Lentes Intraoculares , Animais , Materiais Biocompatíveis , Gatos , Córnea/fisiologia , Córnea/ultraestrutura , Haplorrinos , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Terapia a Laser , Lentes Intraoculares/efeitos adversos , Membranas Artificiais , Polietilenoglicóis , Polímeros , Procedimentos Cirúrgicos Refrativos , SulfonasRESUMO
AIMS: To compare clinical outcomes of patients bilaterally implanted with SN60D3 intraocular lenses (IOLs) with outcomes of bilateral monofocal controls, and to determine the validity of implanting an apodised diffractive lens in a healthy patient population. METHODS: Six unmasked US investigators prospectively enrolled 72 patients aged =70 years with bilateral cataracts in otherwise healthy eyes. Patients underwent routine cataract extraction via phacoemulsification with SN60D3 implantation. Visual outcomes were assessed 1 week, 1 month and 6 months postoperatively. Patients completed two subjective surveys. As controls, 51 patients who were 6 months postoperative to bilateral implantation of AcrySof monofocal IOLs also were assessed. RESULTS: Corrected and uncorrected distance visual acuity was similar across groups. For uncorrected near and intermediate visual acuity, statistically significant differences were found favouring the SN60D3 group (p<0.0001). Contrast sensitivity was significantly better in monofocal patients at 6 cpd and 18 cpd under various lighting conditions. The Functional Evaluation and the Questionnaire demonstrated that SN60D3 patients achieved significantly higher levels of functional vision and spectacle freedom (p<0.0001). CONCLUSION: Despite mildly decreased contrast sensitivity when compared with a monofocal IOL, the SN60D3 provided high patient satisfaction, excellent functional vision, and high rates of spectacle freedom.