Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 150(2): 1108, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34470286

RESUMO

This paper presents a circuit model of the thermoviscous acoustic wave propagation in waveguides with annular cross section. The model, validated against finite element method simulations of the input acoustic impedance, captures the annular waveguide behavior with good accuracy within a frequency bandwidth consistent with the lumped-element approximation. The cascading of multiple circuit models easily allows extending the bandwidth while preserving the same accuracy. The circuit model was derived from the low reduced frequency (LRF) wave propagation model in rectangular layers, representing a valid approximation of the complex LRF solution in annular waveguides. The simplified analytical description allows for the formulation of a compact T-network model comprised of standard circuit elements. This circuit model can be implemented in circuit simulators to accelerate both the analysis and engineering of devices having elements with annular cross section, such as micro-electro-mechanical systems devices or microphones.

2.
BMC Pulm Med ; 18(1): 103, 2018 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-29914454

RESUMO

BACKGROUND: "Velcro-type" crackles on chest auscultation are considered a typical acoustic finding of Fibrotic Interstitial Lung Disease (FILD), however whether they may have a role in the early detection of these disorders has been unknown. This study investigated how "Velcro-type" crackles correlate with the presence of distinct patterns of FILD and individual radiologic features of pulmonary fibrosis on High Resolution Computed Tomography (HRCT). METHODS: Lung sounds were digitally recorded from subjects immediately prior to undergoing clinically indicated chest HRCT. Audio files were independently assessed by two chest physicians and both full volume and single HRCT sections corresponding to the recording sites were extracted. The relationships between audible "Velcro-type" crackles and radiologic HRCT patterns and individual features of pulmonary fibrosis were investigated using multivariate regression models. RESULTS: 148 subjects were enrolled: bilateral "Velcro-type" crackles predicted the presence of FILD at HRCT (OR 13.46, 95% CI 5.85-30.96, p < 0.001) and most strongly the Usual Interstitial Pneumonia (UIP) pattern (OR 19.8, 95% CI 5.28-74.25, p < 0.001). Extent of isolated reticulation (OR 2.04, 95% CI 1.62-2.57, p < 0.001), honeycombing (OR 1.88, 95% CI 1.24-2.83, < 0.01), ground glass opacities (OR 1.74, 95% CI 1.29-2.32, p < 0.001) and traction bronchiectasis (OR 1.55, 95% CI 1.03-2.32, p < 0.05) were all independently associated with the presence of "Velcro-type" crackles. CONCLUSIONS: "Velcro-type" crackles predict the presence of FILD and directly correlate with the extent of distinct radiologic features of pulmonary fibrosis. Such evidence provides grounds for further investigation of lung sounds as an early identification tool in FILD.


Assuntos
Auscultação , Doenças Pulmonares Intersticiais/diagnóstico , Sons Respiratórios/etiologia , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Fibrose Pulmonar Idiopática/diagnóstico , Itália , Modelos Logísticos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos
3.
Phys Chem Chem Phys ; 19(18): 11318-11325, 2017 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-28418063

RESUMO

We report ab initio results for sub-stoichiometric HfOx with different oxygen vacancy densities, useful in exploring microscopic mechanisms that govern the operation of RRAM devices. We demonstrate that oxygen vacancy filaments are energetically more stable than randomly distributed defects. Furthermore, the stability of the filaments increases with the number of confined oxygen vacancies. Energetic and structural analyses show that bonds between neighboring coordinative unsaturated Hf atoms promote filament stability, and electron trapping, due to electron injection, increases the cohesive energy until the injection is moderate. The highly oxygen deficient configuration of the filaments leads to a substantial lowering of the HfOx band gap, which locally increases the conductivity of the system. Charge injection and electric fields modify the mobility of oxygen ions in the proximity of the filament. The simulations suggest that oxygen ion diffusion can lead to an asymmetric reduction of filament thickness and thus to its progressive disruption where the vacancy cohesion energy is lower.

4.
ACS Nano ; 15(11): 17214-17231, 2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34730935

RESUMO

Resistive switching (RS) devices are emerging electronic components that could have applications in multiple types of integrated circuits, including electronic memories, true random number generators, radiofrequency switches, neuromorphic vision sensors, and artificial neural networks. The main factor hindering the massive employment of RS devices in commercial circuits is related to variability and reliability issues, which are usually evaluated through switching endurance tests. However, we note that most studies that claimed high endurances >106 cycles were based on resistance versus cycle plots that contain very few data points (in many cases even <20), and which are collected in only one device. We recommend not to use such a characterization method because it is highly inaccurate and unreliable (i.e., it cannot reliably demonstrate that the device effectively switches in every cycle and it ignores cycle-to-cycle and device-to-device variability). This has created a blurry vision of the real performance of RS devices and in many cases has exaggerated their potential. This article proposes and describes a method for the correct characterization of switching endurance in RS devices; this method aims to construct endurance plots showing one data point per cycle and resistive state and combine data from multiple devices. Adopting this recommended method should result in more reliable literature in the field of RS technologies, which should accelerate their integration in commercial products.

5.
J Phys Condens Matter ; 32(5): 055706, 2020 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-31618727

RESUMO

Hexagonal boron nitride (hBN) is a wide gap 2D layered material with good insulating properties. Intrinsic point defects in hBN play an important role in its applications as a dielectric in 2D electronic devices. However, the electronic properties of these defects are still poorly understood. We have calculated the structure and properties of a wide range of intrinsic point defects in the bulk of hBN using hybrid density functional theory (DFT). These include vacancies and interstitial states of B and N as well as di- and tri-vacancies. For each isolated defect, multiple charge states are calculated, and for each charge state multiple spin states are investigated. Positions of defect charge transition levels in the band gap of hBN are calculated. In particular, we predict that B vacancies are likely to be negatively charged in contact with graphene and other metals. Calculations of the interaction between vacancies predict that divacancies in both B and N sublattices are strongly binding. Moreover, the interaction of single B and N vacancies in adjacent layers induces the creation of -N-N- and -B-B- molecular bridges, which greatly distort the local structure, leading to local bond weakening. These results provide further insight into the properties of defects which can be responsible for degradation of hBN based devices.

6.
Materials (Basel) ; 12(21)2019 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-31652682

RESUMO

Memristor-based neuromorphic systems have been proposed as a promising alternative to von Neumann computing architectures, which are currently challenged by the ever-increasing computational power required by modern artificial intelligence (AI) algorithms. The design and optimization of memristive devices for specific AI applications is thus of paramount importance, but still extremely complex, as many different physical mechanisms and their interactions have to be accounted for, which are, in many cases, not fully understood. The high complexity of the physical mechanisms involved and their partial comprehension are currently hampering the development of memristive devices and preventing their optimization. In this work, we tackle the application-oriented optimization of Resistive Random-Access Memory (RRAM) devices using a multiscale modeling platform. The considered platform includes all the involved physical mechanisms (i.e., charge transport and trapping, and ion generation, diffusion, and recombination) and accounts for the 3D electric and temperature field in the device. Thanks to its multiscale nature, the modeling platform allows RRAM devices to be simulated and the microscopic physical mechanisms involved to be investigated, the device performance to be connected to the material's microscopic properties and geometries, the device electrical characteristics to be predicted, the effect of the forming conditions (i.e., temperature, compliance current, and voltage stress) on the device's performance and variability to be evaluated, the analog resistance switching to be optimized, and the device's reliability and failure causes to be investigated. The discussion of the presented simulation results provides useful insights for supporting the application-oriented optimization of RRAM technology according to specific AI applications, for the implementation of either non-volatile memories, deep neural networks, or spiking neural networks.

7.
Materials (Basel) ; 12(3)2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30717254

RESUMO

: Conductive atomic force microscopy (CAFM) is one of the most powerful techniques in studying the electrical properties of various materials at the nanoscale. However, understanding current fluctuations within one study (due to degradation of the probe tips) and from one study to another (due to the use of probe tips with different characteristics), are still two major problems that may drive CAFM researchers to extract wrong conclusions. In this manuscript, these two issues are statistically analyzed by collecting experimental CAFM data and processing them using two different computational models. Our study indicates that: (i) before their complete degradation, CAFM tips show a stable state with degraded conductance, which is difficult to detect and it requires CAFM tip conductivity characterization before and after the CAFM experiments; and (ii) CAFM tips with low spring constants may unavoidably lead to the presence of a ~1.2 nm thick water film at the tip/sample junction, even if the maximum contact force allowed by the setup is applied. These two phenomena can easily drive CAFM users to overestimate the properties of the samples under test (e.g., oxide thickness). Our study can help researchers to better understand the current shifts that were observed during their CAFM experiments, as well as which probe tip to use and how it degrades. Ultimately, this work may contribute to enhancing the reliability of CAFM investigations.

8.
Nanomaterials (Basel) ; 8(10)2018 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-30322201

RESUMO

In this work, we investigate the thermal and acoustic frequency responses of nanostructured thermoacoustic loudspeakers. An opposite frequency dependence of thermal and acoustic responses was found independently of the device substrate (Kapton and glass) and the nanometric active film (silver nanowires and nm-thick metal films). The experimental results are interpreted with the support of a comprehensive electro-thermo-acoustic model, allowing for the separation of the purely thermal effects from the proper thermoacoustic (TA) transduction. The thermal interactions causing the reported opposite trends are understood, providing useful insights for the further development of the TA loudspeaker technology.

9.
Nanoscale ; 8(16): 8466-73, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-26593053

RESUMO

After more than a decade working with graphene there is still a preoccupying lack of commercial devices based on this wonder material. Here we report the use of high-quality solution-processed graphene sheets to fabricate ultra-sharp probes with superior performance. Nanoprobes are versatile tools used in many fields of science, but they can wear fast after some experiments, reducing the quality and increasing the cost of the research. As the market of nanoprobes is huge, providing a solution for this problem should be a priority for the nanotechnology industry. Our graphene-coated nanoprobes not only show enhanced lifetime, but also additional unique properties of graphene, such as hydrophobicity. Moreover, we have functionalized the surface of graphene to provide piezoelectric capability, and have fabricated a nano relay. The simplicity and low cost of this method, which can be used to coat any kind of sharp tip, make it suitable for the industry, allowing production on demand.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa