Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Phys ; 36(11): 5235-44, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19994534

RESUMO

PURPOSE: The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate brachytherapy treatment room. METHODS: This intraoperative detection allows a complete dosimetry calculation that can be performed right after an I-125 prostate seed implantation, while the patient is still under anesthesia. To accomplish this, a digital tomosynthesis-based algorithm was developed. This automatic filtered reconstruction of the 3D volume requires seven projections acquired over a total angle of 60 degrees with an isocentric imaging system. RESULTS: A phantom study was performed to validate the technique that was used in a retrospective clinical study involving 23 patients. In the patient study, the automatic tomosynthesis-based reconstruction yielded seed detection rates of 96.7% and 2.6% false positives. The seed localization error obtained with a phantom study is 0.4 +/- 0.4 mm. The average time needed for reconstruction is below 1 min. The reconstruction algorithm also provides the seed orientation with an uncertainty of 10 degrees +/- 8 degrees. The seed detection algorithm presented here is reliable and was efficiently used in the clinic. CONCLUSIONS: When combined with an appropriate coregistration technique to identify the organs in the seed coordinate system, this algorithm will offer new possibilities for a next generation of clinical brachytherapy systems.


Assuntos
Algoritmos , Braquiterapia/métodos , Monitorização Intraoperatória/métodos , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Automação , Humanos , Imageamento Tridimensional/métodos , Radioisótopos do Iodo/uso terapêutico , Masculino , Imagens de Fantasmas , Radiografia , Estudos Retrospectivos , Tomografia/métodos , Incerteza
2.
Int J Radiat Oncol Biol Phys ; 72(2): 605-9, 2008 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-18793964

RESUMO

PURPOSE: To identify dosimetric parameters predictive of a good prostate seed I(125) quality implant. We analyzed preimplant and postimplant realtime dosimetry in patients treated with intraoperative (IO) inverse planning. METHODS AND MATERIALS: We analyzed 127 consecutively treated patients with primarily low-risk prostate carcinoma who underwent prostate permanent seed I(125) brachytherapy using an IO planning approach. The implant was done using the three-dimensional transrectal ultrasound (PRE-TRUS)-guided IO interactive inverse preplanning system. The TRUS was repeated in the operating room after the implant procedure was complete (POST-TRUS). The prostate was recontoured and postimplant dosimetry was calculated. Each patient underwent computed tomography scan on Day 28 (CT-D28) to evaluate implant quality. Area under the receiver operating characteristic curves (AUROC) was evaluated for models predictive of a V100 of > or =90% and a D90 of > or =140 Gy on the basis of CT-D28 values. RESULTS: On CT-D28, 72.4% of patients had a V100 of > or =90% and 74.8% had a D90 of > or =140 Gy. AUROC for a V100 of > or =90% was 0.665 (p = 0.004) on PRE-TRUS and 0.619 (p = 0.039) on POST-TRUS. AUROC for D90 of > or =140 Gy was 0.602 (p = 0.086) on PRE-TRUS and 0.614 (p = 0.054) on POST-TRUS. Using PRE-TRUS V100 cutoff of >97% gives sensitivity of 88% and a false-positive rate of 63%. A POST-TRUS D90 cutoff of >170 Gy resulted in a sensitivity of 62% and a false-positive rate of 34%. CONCLUSIONS: Because of unacceptably high false-positive rates, IO preimplant and postimplant TRUS-based dosimetry are not accurate tools to predict for postimplant computed tomography-based dosimetry.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Próstata/radioterapia , Idoso , Área Sob a Curva , Reações Falso-Positivas , Humanos , Imageamento Tridimensional , Radioisótopos do Iodo/uso terapêutico , Masculino , Pessoa de Meia-Idade , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/diagnóstico por imagem , Radiometria , Dosagem Radioterapêutica , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa