Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Circulation ; 104(6): 711-6, 2001 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-11489780

RESUMO

BACKGROUND: A variety of transcatheter atrial septal defect (ASD) occluders are currently in use around the world. Although for the most part effective, all of these devices lack features that would be desirable in a "perfect" device. The Helex septal occluder is a new type of device designed to improve the results of transcatheter ASD closure. This study was designed to examine the effectiveness and safety of this occluder in an animal model. METHODS AND RESULTS: The Helex was implanted into 24 dogs with surgically created ASDs. Procedural details focusing on deployment, removal, and early closure rates were examined. Follow-up consisted of sequential transesophageal echocardiography and fluoroscopy as well as epicardial contrast echocardiography and angiography at the time of death. Specimens were examined grossly and histologically, and devices were tested for metal fatigue. All animals had successful ASD closure. Implantation was uncomplicated (mean fluoroscopy time 11.7 minutes), and removal or repositioning was always possible. Closure rate as judged by transesophageal echocardiography was 88% initially and 100% at 2-week follow-up. Devices rapidly became infiltrated with connective tissue without inflammation and were endothelialized over time. There were no instances of thromboembolism. A single wire-frame fracture occurred secondary to a prototype delivery system malfunction. CONCLUSIONS: The Helex septal occluder proved safe and effective for ASD closure. Several advantages over currently available devices were evident in this model. Controlled prospective clinical trials are needed.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Animais , Cateterismo Cardíaco/métodos , Cães , Ecocardiografia , Desenho de Equipamento , Segurança de Equipamentos , Fluoroscopia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/patologia , Politetrafluoretileno
2.
J Am Coll Cardiol ; 30(7): 1847-52, 1997 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9385917

RESUMO

OBJECTIVES: In this study we report our preliminary results and intermediate-term follow-up (up to 3.5 years) of stent implantation for coarctation of the aorta (COA). BACKGROUND: Balloon angioplasty has gained acceptance as a modality of treatment for COA. Some patients do not respond optimally to balloon angioplasty alone. Balloon-expandable stents have been used in pulmonary arteries and large systemic arteries such as the femoroiliac vessels, with a significant improvement in vessel patency and a reduction in the pressure gradient compared with balloon angioplasty alone. METHODS: Nine patients (>10 years old) with COA in whom balloon dilation alone was thought to be ineffective underwent stent implantation. Seven patients had a previous operation or balloon dilation, or both, to relieve their coarctation but had a significant residual/recurrent gradient. RESULTS: At the time of stent implantation, the systolic and mean gradients decreased from a mean (+/-SEM) of 37 +/- 7 and 14 +/- 3 mm Hg to 4 +/- 1 and 2 +/- 0.6 mm Hg, respectively (p < or = 0.002). The coarctation diameter increased from a mean of 9 +/- 1 to 15 +/- 1 mm (p < 0.002). The patients have been followed for up to 42 months (mean 18, median 13) with no complications; the stents remain in position with no fracture. One patient underwent further successful dilation 3 years after stent implantation because of an exercise-induced gradient. No other intervention has been required. The systolic gradient at latest follow-up is 7 +/- 2 mm Hg. Only two (a 44-year old with diabetes and a 50-year old with long-standing hypertension) of five patients previously requiring antihypertensive treatment still remain on medications for blood pressure control. CONCLUSIONS: The use of stents in COA is a feasible alternative to surgical repair or balloon angioplasty in selected patients with an effective gradient reduction. Intermediate-term follow-up shows excellent gradient relief, with no complications in this group of patients.


Assuntos
Coartação Aórtica/terapia , Stents , Adolescente , Adulto , Angioplastia com Balão , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Cateterismo Cardíaco , Feminino , Seguimentos , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Fatores de Tempo , Resultado do Tratamento
3.
J Am Coll Cardiol ; 4(6): 1242-6, 1984 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-6501723

RESUMO

To determine the feasibility and accuracy of noninvasive assessment of pulmonary artery and aortic arch anatomy, a prospective two-dimensional echocardiographic evaluation was performed in 20 consecutive cyanotic infants before cardiac catheterization and angiography. The echocardiographic assessment was correct with the following frequency: detection of left aortic arch in 13 of 13 infants, detection of right aortic arch in 7 of 7, identification of patent ductus arteriosus in 13 of 13 (one false positive finding), identification of a right pulmonary artery in 20 of 20, identification of a left pulmonary artery in 19 of 20, identification of the confluence of the right and left pulmonary arteries in 19 of 20 and identification of a main pulmonary artery in 14 of 16 (two false positive diagnoses by echocardiography). Echocardiographic estimates of arterial diameters were slightly smaller than those obtained by angiography. Mean vessel size (echocardiographic/angiographic diameter) was as follows: transverse aortic arch 8.6/10.6 mm, main pulmonary artery 5.7/6.3 mm, right pulmonary artery 4.1/4.2 mm and left pulmonary artery 4.2/3.9 mm. It is concluded that although two-dimensional echocardiography tends to underestimate vessel size, the qualitative assessment is adequate for planning a systemic to pulmonary artery anastomosis in selected infants with cyanotic forms of congenital heart disease.


Assuntos
Aorta Torácica/patologia , Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico , Artéria Pulmonar/patologia , Cateterismo Cardíaco , Permeabilidade do Canal Arterial/diagnóstico , Cardiopatias Congênitas/patologia , Humanos , Lactente , Recém-Nascido , Cuidados Pré-Operatórios , Estudos Prospectivos
4.
J Am Coll Cardiol ; 2(3): 531-7, 1983 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-6875116

RESUMO

The results of two-dimensional echocardiography and biplane angiocardiography from 47 infants with congenital atrioventricular (AV) valve abnormalities were compared. Eleven patients had atresia of the right AV valve, 10 had atresia of the left AV valve, 4 had hypoplasia of the right AV valve and 5 had hypoplasia of the left AV valve. Twelve patients had endocardial cushion defect, three had single ventricle and two had straddling of the left AV valve. There was agreement between the two techniques as to the number of AV valves present in each patient. The echocardiographic estimate of valve anular diameter was below normal in seven of the eight patients thought to have a hypoplastic anulus by angiocardiography. In 10 of the 12 patients with endocardial cushion defect, there was agreement between the two techniques as to the presence or absence of atrial and ventricular septal defect. The chordal attachments of straddling valves were better visualized by echocardiography; flow patterns and effective orifice size were better demonstrated by angiocardiography. The subcostal four chamber echocardiographic views and cranially angulated oblique angiocardiographic views were comparable and provided the best images for determination of the size and number of AV valves and their relation to the atrial and ventricular septa.


Assuntos
Angiocardiografia , Ecocardiografia , Valva Mitral/anormalidades , Valva Tricúspide/anormalidades , Comunicação Atrioventricular/diagnóstico , Cardiopatias Congênitas/diagnóstico , Humanos , Lactente
5.
J Am Coll Cardiol ; 28(7): 1810-7, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8962571

RESUMO

OBJECTIVES: This study sought to compare the immediate results and risk factors for suboptimal outcomes of percutaneous balloon angioplasty for native versus recurrent aortic obstruction. BACKGROUND: Some cardiology centers have been reluctant to adopt balloon angioplasty for treatment of native aortic coarctation, while advocating balloon angioplasty over an operation for treatment of postsurgical or recurrent aortic obstruction. METHODS: Acute results were analyzed from 970 procedures (422 native and 548 recurrent lesions) performed between 1982 and 1995 in 907 patients from 25 centers. An acute suboptimal outcome was defined as one or more of the following: residual systolic pressure gradient > or = 20 mm Hg, residual proximal to distal systolic pressure ration > or = 1.33 or a major complication (death, aortic transmural tear, stroke). RESULTS: Bal loon angioplasty significantly (p = 0.0001) increased lesion diameter fo r both native (mean [+/= SD] 128 +/= 94%) and recurrent aortic obstruction (97 +/= 87%), with a significantly greater increase in the native group (p = 0.0001). A reduction in systolic pressure gradients was significant in both groups (p = 0.0001), but slightly higher (p = 0.01) for native (-74 +/- 24%) versus recurrent obstruction (-70 +/- 31%). Death associated with angioplasty was reported in 0.7% of patients with native and in 0.7% of patients with recurrent lesions (p = 1.00). An acute suboptimal outcome was noted with angioplasty in 19% of native and in 25% of recurrent lesions (p = 0.04). Significant independent risk factors included higher preangioplasty systolic gradient (odds ratio [OR] 1.39/10-mm Hg increment; 95% confidence interval [CI] 1.28 to 1.50, p = 0.0001), earlier study date (OR 0.92/1-year increment, 95% CI 1.02 to 1.26, p = 0.02) and recurrent obstruction (OR 1.39 vs. native lesions, 95% CI 1.00 to 1.94, p = 0.05). CONCLUSIONS: Acute results and complications of balloon angioplasty of native coarctation appear to be equivalent or slightly superior to those of recurrent aortic obstructions.


Assuntos
Angioplastia com Balão , Aorta Torácica/patologia , Coartação Aórtica/terapia , Adolescente , Adulto , Angioplastia com Balão/efeitos adversos , Aorta Torácica/cirurgia , Criança , Pré-Escolar , Constrição Patológica , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/terapia , Recidiva , Fatores de Risco
6.
J Nucl Med ; 25(9): 1003-12, 1984 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-6470803

RESUMO

A multiwire proportional counter gamma camera, specifically designed for nuclear medicine applications, is portable and weighs less than 50 lb including shielding and collimator. The basic operating characteristics have been investigated with various radioactive sealed sources. The camera demonstrates a peak count rate of 850,000 cps, an intrinsic spatial resolution of 2.5 mm, and excellent image uniformity when used with x-ray sources in the range of 22-81 keV. Tests of the device with Ta-178--a very promising, short half-life (9.3 min), low-energy radionuclide--using 20 mCi injections provided images of quality comparable to those obtained from 15 mCi Tc-99m studies with conventional imaging devices. The camera used with Ta-178 offers particular promise in first-pass nuclear cardiology studies. Considerably improved study quality will likely result in this area because of the increased injectable dose levels offered by Ta-178 combined with the high-count rate capability and improved resolution.


Assuntos
Medicina Nuclear/instrumentação , Fotografação/instrumentação , Contagem de Cintilação/instrumentação , Amerício , Animais , Cádmio , Computadores , Cães , Eletrônica , Estudos de Avaliação como Assunto , Ventrículos do Coração/diagnóstico por imagem , Radioisótopos , Cintilografia , Volume Sistólico , Suínos , Tantálio
7.
Am J Cardiol ; 50(3): 560-8, 1982 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7051799

RESUMO

The results of long-term follow-up studies of patients with five common congenital heart defects are reviewed. The lesions included are ventricular septal defect, atrial septal defect, patent ductus arteriosus, pulmonary stenosis and coarctation of the aorta. A definitive, rather than palliative, operation has been available for each of these lesions for more than 25 years. Therefore many patients who have undergone operation for one of these lesions are now reaching adulthood. Although most of these postoperative patients live a normal life, many have residuae or sequelae that require close observation or treatment. Other persistent abnormalities of the physical examination, electrocardiogram and chest radiogram are obvious but call for no precaution or treatment. We have drawn on our own experience and the published experience of others to identify those findings and historical factors that best reflect the long-term prognosis of these patients. In addition, recommendations concerning the need for continued prophylaxis against infective endocarditis, and the problems of insurability and employability of these postoperative patients are discussed.


Assuntos
Cardiopatias Congênitas/cirurgia , Adulto , Coartação Aórtica/cirurgia , Cateterismo Cardíaco , Criança , Permeabilidade do Canal Arterial/cirurgia , Eletrocardiografia , Emprego , Endocardite Bacteriana/prevenção & controle , Seguimentos , Cardiopatias Congênitas/epidemiologia , Comunicação Interatrial/cirurgia , Comunicação Interventricular/cirurgia , Humanos , Seguro de Vida , Exame Físico , Prognóstico , Estenose da Valva Pulmonar/cirurgia , Radiografia Torácica
8.
Am J Cardiol ; 76(10): 695-8, 1995 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-7572627

RESUMO

To evaluate whether transcatheter closure of secundum atrial septal defects (ASD) affected noninvasive electrophysiologic variables in children, we reviewed the pre-procedural and 1-year postprocedural electrocardiograms and Holter recordings of 18 consecutive children referred for ASD closure. Patients included in the study were a mean of 5.0 years old (SD 1.1) and weighed a mean of 17.9 kg (SD 4.1). ASDs had a mean diameter of 14.0 mm (SD 2.4) and average shunt ratio (pulmonary-to-systemic flow) of 2.1:1. One year after occluder device placement, 9 children (50%) had detectable residual shunts by transthoracic echocardiograms, but only 2 (11%) had shunts that were felt to be possibly significant. One or more fractured occluder legs were noted by chest roentgenogram in 15 patients (83%). Electrocardiograms at follow-up demonstrated improvement in right ventricular dilation in 4 of 7 patients, right atrial enlargement in 3 of 4 patients, and 1 degree atrioventricular block in 2 of 3 patients. Holter recordings showed a decreased incidence of accelerated atrial rhythm in 3 of 7 patients, prolonged junctional escape rhythm in 2 of 2 patients, and premature atrial contractions in 2 of 2 patients. No finding correlated with patient age, defect or occluder diameter, occluder leg fracture(s), or residual defects. These improvements in electrophysiologic abnormalities compare favorably with changes seen 1 year after surgical closure. In conclusion, placement of a transcatheter ASD device in children diminishes noninvasive electrophysiologic abnormalities at 1-year follow-up. By relieving hemodynamic stress caused by an ASD in childhood, a transcatheter device may prevent arrhythmia disturbance later in life.


Assuntos
Comunicação Interatrial/terapia , Próteses e Implantes , Cateterismo Cardíaco , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Eletrocardiografia , Eletrocardiografia Ambulatorial , Eletrofisiologia , Feminino , Seguimentos , Comunicação Interatrial/fisiopatologia , Humanos , Masculino
9.
Am J Cardiol ; 48(1): 106-10, 1981 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7246432

RESUMO

The resolution and accuracy of commercially available two dimensional echocardiographic systems were tested by imaging two types of in vitro test objects. One consisted of a series of fine parallel threads spaced at known intervals and the other was a tissue phantom in which a series of holes of known size had been cut. The echocardiographic systems tested included a mechanical single element sector scanner, a three element rotary sector scanner and a phased array system. Azimuthal resolution, lateral resolution and accuracy of horizontal distance measurements were assessed at depths of 2 and 6 cm. For each system, azimuthal resolution was better than lateral resolution, especially when assessed with use of the parallel threads. When the tissue phantom was imaged, the best resolution (2 mm in azimuthal and lateral directions) was obtained with the highest frequency transducer tested (3.5 MHz). The apparent size of a tissue defect was sensitive to gain settings, especially at a depth of 2 cm with lower frequency transducers; at a depth of 6 cm, echographic measurements of defect size were accurate to within 2.5 mm. Recent applications of two dimensional echocardiography require near the apparent limits of current equipment. It is recommended that the highest frequency transducer and lowest possible gain settings be used in these situations.


Assuntos
Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico , Cardiomiopatias/diagnóstico , Comunicação Interventricular/diagnóstico , Humanos
10.
Am J Cardiol ; 49(7): 1773-7, 1982 May.
Artigo em Inglês | MEDLINE | ID: mdl-6211077

RESUMO

M mode echocardiography was used to evaluate nine neonates with absent pulmonary valve syndrome. Six were also studied with two dimensional echocardiography and two with pulsed Doppler echocardiography. M mode echocardiography demonstrated a large, overriding great artery and right ventricular dilation in all nine patients and abnormal septal motion in eight. Two dimensional echocardiography demonstrated aneurysmal dilation of the main pulmonary artery in all six patients studied. Pulsed Doppler echocardiography in the two infants studied demonstrated anterograde systolic and retrograde diastolic flow in the main pulmonary artery and right ventricular outflow tract. The echocardiographic features of absent pulmonary valve syndrome appear to be unique and allow the diagnosis to be made noninvasively, thus obviating or delaying the need for potentially high risk cardiac catheterization.


Assuntos
Ecocardiografia/métodos , Valva Pulmonar/anormalidades , Aneurisma/congênito , Cardiomegalia/congênito , Diagnóstico Diferencial , Feminino , Insuficiência Cardíaca/etiologia , Comunicação Interventricular/diagnóstico , Humanos , Lactente , Recém-Nascido , Masculino , Artéria Pulmonar/anormalidades , Síndrome do Desconforto Respiratório do Recém-Nascido/etiologia , Síndrome
11.
Am J Cardiol ; 47(1): 85-9, 1981 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-7457414

RESUMO

To determine the sensitivity and specificity of two dimensional echocardiography in detecting ventricular septal defect two dimensional echocardiograms were performed on 53 infants under 1 year of age. The diagnosis of ventricular septal defect was confirmed by cardiac catheterization in 27 patients; an intact ventricular septum was confirmed by catheterization in 18 and clinically in 8. Using a 35 degree mechanical sector scanner with a 3.5 megahertz transducer, we imaged the ventricular septum in the long axis and in a four chamber view (apical or subcostal, or both). Images were recorded on videotape and reviewed independently by two observers unaware of the diagnosis. Interobserver agreement was 94 percent. Among the 27 patients with a ventricular septal defect, the lesion was correctly identified in 20 (74 percent) and was undetected in 7 (3 of whom had a defect less than 4 mm in diameter, as determined by angiography). No defect less than 4 mm in diameter was detected. Among the 26 patients with an intact septum, a defect was correctly excluded in 23 (88 percent); a false positive diagnosis was made in 3. The apical and subcostal views demonstrated the greatest number of defects (20 of 20), but also gave the highest number of false positive diagnoses (3 of 3). The long axis view was helpful when positive, but showed only 9 of 20 of the defects. In this study, two dimensional echocardiography detected approximately three fourths of ventricular septal defects large enough to warrant cardiac catheterization in the 1st year of life. False positive diagnoses were related to dropout of echoes in the membranous septum when imaged in the four chamber views.


Assuntos
Ecocardiografia , Comunicação Interventricular/diagnóstico , Cateterismo Cardíaco , Reações Falso-Positivas , Humanos , Lactente , Recém-Nascido
12.
Am J Cardiol ; 65(11): 802-3, 1990 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-2316464

RESUMO

Data on 111 lesions, in addition to pulmonary valve, aortic valve, branch pulmonary stenosis, native coarctation and recoarctation, were submitted to the Valvuloplasty and Angioplasty of Congenital Anomalies Registry. Because there was a very heterogenous group of lesions both in types of lesions and techniques of dilation, only minimal data can be offered concerning the efficacy of the dilation of any or all of these lesions. The registry data do, however, demonstrate the safety of these dilations compared to alternative surgical therapy.


Assuntos
Cateterismo , Cardiopatias Congênitas/terapia , Sistema de Registros , Constrição Patológica/terapia , Próteses Valvulares Cardíacas , Humanos , Complicações Pós-Operatórias/terapia , Estados Unidos
13.
Am J Cardiol ; 78(11): 1310-2, 1996 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-8960600

RESUMO

Of 31 patients who underwent transcatheter atrial septal defect occlusion with the Bard Clamshell Septal Umbrella, only 1 had a clinically significant residual atrial septal defect at a mean follow-up of 41 months. All patients were asymptomatic despite the occurrence of device arm fractures in 84% of these patients.


Assuntos
Comunicação Interatrial/cirurgia , Adolescente , Adulto , Criança , Pré-Escolar , Ecocardiografia , Eletrocardiografia Ambulatorial , Falha de Equipamento , Estudos de Avaliação como Assunto , Feminino , Seguimentos , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes/efeitos adversos , Resultado do Tratamento , Função Ventricular Direita
14.
Am J Cardiol ; 53(11): 1652-5, 1984 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-6731311

RESUMO

To study the accuracy of 2-dimensional echocardiography (2-D echo) in estimating mitral and tricuspid anular diameter, 2-D echo estimates were compared with autopsy measurements of anular diameter in 21 children studied by echo within 30 days of death. The mitral anulus was measured from the left parasternal long axis view and the apical or subcostal 4-chamber image and the tricuspid anulus from the 4-chamber view. Comparable measurements were made from the autopsy specimen with calipers. The correlation coefficient for echocardiographic vs autopsy measurements was 0.79 (standard error of the estimate 2.8 mm) (mitral long axis r = 0.76, mitral 4-chamber r = 0.85, tricuspid 4-chamber r = 0.76). Echo measurements exceeded the corresponding autopsy measurements by an average of 17%; this was at least partially attributed to shrinkage of the specimen during fixation. Thus, 2-D echo may be used to provide a reasonable estimate of mitral and tricuspid anular diameter.


Assuntos
Ecocardiografia , Valva Mitral/anatomia & histologia , Valva Tricúspide/anatomia & histologia , Adolescente , Adulto , Autopsia , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Valva Mitral/anormalidades , Valva Tricúspide/anormalidades
15.
Am J Cardiol ; 55(5): 514-8, 1985 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-3969891

RESUMO

To assess the accuracy of 2-dimensional (2-D) echocardiography in the evaluation of cardiac anatomy in patients with congenital heart disease, 2-D echocardiograms were performed in 126 infants and children before cardiac catheterization and angiocardiography. The segmental echocardiographic analysis included determination of intracardiac, great artery, systemic venous and pulmonary venous anatomy. The 126 patients had 259 separate cardiovascular abnormalities, of which 226 (87%) were prospectively identified by 2-D echocardiography. There were 8 false-positive diagnoses. The most common lesions and the sensitivity and specificity of echocardiography were: patent ductus arteriosus, 41 patients (83% and 100%, respectively), ventricular septal defect, 35 patients (86% and 100%); atrial septal defect, 26 patients (85% and 99%); pulmonary valve stenosis, 25 patients (77% and 97%), transposition of the great arteries, 16 patients (100% and 100%); and total anomalous pulmonary venous connection, 14 patients (85% and 100%). Less common defects and their rate of detection included coarctation of the aorta, 10 of 12 patients; atrioventricular canal, 10 of 10 patients; tetralogy of Fallot, 10 of 10 patients; aortic valve stenosis 8 of 8 patients; right aortic arch, 8 of 8 patients; interrupted aortic arch, 4 of 4 patients; and unilateral pulmonary vein atresia, 0 of 1 patient. In 33 patients (26%), the errors in echocardiographic analysis were judged to have surgical importance. Most errors were the result of overlooking or misinterpreting data that had been appropriately recorded on videotape. Pulmonary valve stenosis and patent ductus arteriosus are the lesions most likely to be misdiagnosed by ultrasound studies relying on imaging alone.


Assuntos
Ecocardiografia , Cardiopatias Congênitas/diagnóstico , Cateterismo Cardíaco , Criança , Erros de Diagnóstico , Permeabilidade do Canal Arterial/diagnóstico , Cardiopatias Congênitas/cirurgia , Comunicação Interatrial/diagnóstico , Comunicação Interventricular/diagnóstico , Humanos , Lactente , Estudos Prospectivos , Estenose da Valva Pulmonar/diagnóstico , Veias Pulmonares/anormalidades , Transposição dos Grandes Vasos/diagnóstico
16.
Am J Cardiol ; 83(6): 981-3, A10, 1999 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-10190426

RESUMO

A new type of delivery catheter, designed with a 0.033-inch distal tip that grips a 0.038-inch Gianturco coil, was used to occlude 61 abnormal vascular connections in 44 patients with a complete closure rate of 87%. Withdrawal (n = 6) or repositioning (n = 2) of an inappropriately positioned coil was necessary in 8 of 44 patients, and was successfully achieved in all by the delivery catheter without need for additional equipment.


Assuntos
Fístula Arteriovenosa/terapia , Malformações Arteriovenosas/terapia , Cateterismo , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Humanos
17.
Ann Thorac Surg ; 59(3): 738-40, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7887722

RESUMO

Management options for severe, bilateral branch pulmonary artery stenosis include percutaneous balloon dilation and direct surgical correction. Results with both balloon angioplasty and operation have been somewhat unpredictable. We report a case of staged surgical correction involving bilateral branch pulmonary artery reconstruction.


Assuntos
Arteriopatias Oclusivas/cirurgia , Artéria Pulmonar/cirurgia , Anastomose Cirúrgica , Angioplastia , Arteriopatias Oclusivas/congênito , Arteriopatias Oclusivas/patologia , Ponte Cardiopulmonar , Criança , Constrição Patológica , Feminino , Humanos , Artéria Pulmonar/patologia , Índice de Gravidade de Doença , Toracotomia
18.
Ann Thorac Surg ; 64(3): 836-8, 1997 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9307485

RESUMO

An infant with hypoplastic left heart syndrome presented for surgical repair at 9 months of age, the ductus having remained open in the presence of a restrictive atrial septal defect. In addition, an anomalous left coronary artery originating from the right pulmonary artery was found. After preliminary blade/balloon atrial septostomy, a successful modified Norwood procedure with concomitant reimplantation of the anomalous coronary artery was performed.


Assuntos
Anomalias dos Vasos Coronários/cirurgia , Síndrome do Coração Esquerdo Hipoplásico/complicações , Artéria Pulmonar/anormalidades , Permeabilidade do Canal Arterial/cirurgia , Comunicação Interatrial/complicações , Comunicação Interatrial/cirurgia , Septos Cardíacos/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Artéria Pulmonar/cirurgia , Reimplante
19.
Ann Thorac Surg ; 70(1): 100-5, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10921690

RESUMO

BACKGROUND: In patients with atrioventricular and arterioventricular discordance congenitally corrected transposition, the morphologically right ventricle may progressively deteriorate while functioning in the systemic circuit. The double switch operation has been proposed to limit this functional deterioration. METHODS: From October 1993 to August 1998, the records of 27 patients with congenitally corrected transposition were reviewed. Age at operation ranged from 3 months to 55 years. Associated defects included ventricular septal defects in 18, pulmonary atresia in 7, and pulmonary stenosis in 11 patients. Twenty-two patients had double switch operations (10 arterial switch plus Senning procedures and 12 Rastelli plus Senning procedures). Five patients were not candidates for the double switch. Before the double switch, 6 patients required pulmonary artery banding and 10 had functioning systemic to pulmonary artery or cavopulmonary shunts. RESULTS: There was no early or late mortality. Two patients required pacemaker implantation, both later regained normal sinus rhythm. Tricuspid valve function improved in all patients except one. Moderate left ventricular dysfunction developed 5 months postoperatively in 1 patient. CONCLUSIONS: The double switch operation can be performed in selected patients with minimal early morbidity and mortality. Longer follow-up is necessary to determine whether this complex approach is indeed warranted.


Assuntos
Transposição dos Grandes Vasos/cirurgia , Adolescente , Adulto , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Pré-Escolar , Seguimentos , Humanos , Lactente , Pessoa de Meia-Idade
20.
J Invasive Cardiol ; 13(1): 44-6, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11146688

RESUMO

During surgical repair of a neonatal coarctation it was recognized that this was a rare, previously undescribed form of stenosis of the entire descending thoracic aorta. A few hours after the end-to-end surgical repair, the child underwent successful balloon angioplasty, involving the entire descending thoracic aorta, and in which we intentionally avoided the surgical site.


Assuntos
Angioplastia com Balão , Aorta Torácica/anormalidades , Coartação Aórtica/cirurgia , Arteriopatias Oclusivas/terapia , Cuidados Pós-Operatórios/métodos , Anormalidades Múltiplas , Angiografia , Aorta Torácica/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Arteriopatias Oclusivas/congênito , Arteriopatias Oclusivas/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa