Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Mater Sci Mater Med ; 29(7): 104, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29961132

RESUMO

In the present study, a model for simulations of removal torque experiments was developed using finite element method. The interfacial retention and fracturing of the surrounding material caused by the surface features during torque was analyzed. It was hypothesized that the progression of removal torque and the phases identified in the torque response plot represents sequential fractures at the interface. The 3-dimensional finite element model fairly accurately predicts the torque required to break the fixation of acid-etched implants, and also provides insight to how sequential fractures progress downwards along the implant side.


Assuntos
Planejamento de Prótese Dentária , Imageamento Tridimensional , Modelos Dentários , Fraturas dos Dentes/fisiopatologia , Fenômenos Biomecânicos , Implantação Dentária Endóssea , Implantes Dentários , Progressão da Doença , Análise de Elementos Finitos , Humanos , Teste de Materiais , Osseointegração/fisiologia , Polímeros/química , Software , Propriedades de Superfície , Titânio/química , Torque
2.
Clin Oral Implants Res ; 24(9): 1009-17, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22697421

RESUMO

OBJECTIVES: The aim of this study was to investigate the correlation between coating thickness and the crystal structure of physical-vapour-deposited (PVD) titanium dioxide coatings, and to evaluate their in vivo biocompatibility. MATERIALS AND METHODS: The PVD TiO 2 coatings of different thickness were deposited on machined titanium grade 2 screw-shaped implants. Non-coated titanium implants were used as controls. Coating properties such as thickness, crystal structure, coating morphology and roughness were characterized. Forty-eight implants were placed randomly into both tibias of 16 rats. The animals were euthanized 7 and 28 days postsurgery and block biopsies were prepared for histology, histomorphometry and SEM analysis. RESULTS: The thicknesses of the PVDTiO 2 coatings were 120 and 1430 nm respectively. Histologically, new bone formed on all implant surfaces. The mean percentage of newly formed bone in contact with the implant (BIC) was significantly higher at early healing time (7 days) for the 120 nm thick PVD coating (39 ± 14%) than for both the 1430 nm thick PVD coating (22 ± 10%) (P = 0.043) and the machined surface (22 ± 9%) (P = 0.028). This difference was no longer evident after 28 days (P = 0.867). CONCLUSION: Bone formation and bone-to-implant contact are achieved to the same degree for TiO 2 surface modifications prepared by a PVD process as clinically used, machined titanium. Furthermore, a relatively thinner PVD coating promotes a higher degree of bone apposition shortly after implantation, thereby providing rationales for exploring the potential clinical use of these modifications.


Assuntos
Implantes Dentários , Osseointegração/fisiologia , Titânio/química , Animais , Fenômenos Biomecânicos , Materiais Revestidos Biocompatíveis/química , Cristalização , Implantação Dentária Endóssea , Implantes Experimentais , Masculino , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Ratos , Ratos Sprague-Dawley , Propriedades de Superfície , Tíbia/cirurgia
3.
Respiration ; 86(2): 135-42, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23816544

RESUMO

BACKGROUND: Smoking, along with many respiratory diseases, has been shown to induce airway inflammation and alter the composition of the respiratory tract lining fluid (RTLF). We have previously shown that the phospholipid and protein composition of particles in exhaled air (PEx) reflects that of RTLF. In this study, we hypothesized that the composition of PEx differs between smokers and non-smokers, reflecting inflammation in the airways. OBJECTIVE: It was the aim of this study to identify differences in the phospholipid composition of PEx from smokers and non-smokers. METHODS: PEx from 12 smokers and 13 non-smokers was collected using a system developed in-house. PEx was analysed using time-of-flight secondary ion mass spectrometry, and the mass spectral data were evaluated using multivariate analysis. Orthogonal partial least squares (OPLS) was used to relate smoking status, lung function and pack years to the chemical composition of RTLF. The discriminating ions identified by OPLS were then used as explanatory variables in traditional regression analysis. RESULTS: There was a clear discrimination between smokers and non-smokers according to the chemical composition, where phospholipids from smokers were protonated and sodiated to a larger extent. Poor lung function showed a strong association with higher response from all molecular phosphatidylcholine species in the samples. Furthermore, the accumulated amount of tobacco consumed was associated with variations in mass spectra, indicating a dose-response relationship. CONCLUSION: The chemical composition of PEx differs between smokers and non-smokers, reflecting differences in the RTLF. The results from this study may suggest that the composition of RTLF is affected by smoking and may be of importance for lung function.


Assuntos
Ar/análise , Testes Respiratórios/métodos , Óxido Nítrico/análise , Fumar/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Expiração , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Análise Multivariada
4.
Nanomedicine ; 9(7): 1048-56, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23639678

RESUMO

Nanometer scale surface features on implants and prostheses can potentially be used to enhance osseointegration and may also add further functionalities, such as infection resistance, to the implant. In this study, a nanostructured noble metal coating consisting of palladium, gold and silver, never previously used in bone applications, was applied to machined titanium screws to evaluate osseointegration after 6 and 12 weeks in rabbit tibiae and femurs. Infection resistance was confirmed by in vitro adhesion test. A qualitatively and quantitatively similar in vivo bone response was observed for the coated and uncoated control screws, using histology, histomorphometry and electron microscopy. The bone-implant interface analysis revealed an extensive bone formation and direct bone-implant contact. These results demonstrate that the nanostructured noble metal coating with antimicrobial properties promotes osseointegration and may therefore be used to add extra implant functionality in the form of increased resistance to infection without the use of antibiotics. FROM THE CLINICAL EDITOR: The authors of this paper demonstrate that nanostructured noble metal coating of implants and prostheses used in orthopedic procedures promotes osseointegration and may be used to add extra implant functionality in the form of increased resistance to infection without the use of antibiotics.


Assuntos
Anti-Infecciosos/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Metais/farmacologia , Nanoestruturas/química , Osseointegração/efeitos dos fármacos , Titânio/farmacologia , Animais , Aderência Bacteriana/efeitos dos fármacos , Contagem de Colônia Microbiana , Fêmur/efeitos dos fármacos , Fêmur/fisiologia , Fêmur/ultraestrutura , Implantes Experimentais , Interferometria , Nanoestruturas/ultraestrutura , Osteogênese/efeitos dos fármacos , Espectroscopia Fotoeletrônica , Coelhos , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/crescimento & desenvolvimento , Propriedades de Superfície , Tíbia/efeitos dos fármacos , Tíbia/fisiologia , Tíbia/ultraestrutura
5.
Biomed Mater ; 16(4)2021 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-34030145

RESUMO

The cancer microenvironment influences tumor progression and metastasis and is pivotal to consider when designingin vivo-like cancer models. Current preclinical testing platforms for cancer drug development are mainly limited to 2D cell culture systems that poorly mimic physiological environments and traditional, low throughput animal models. The aim of this work was to produce a tunable testing platform based on 3D printed scaffolds (3DPS) with a simple geometry that, by extracellular components and response of breast cancer reporter cells, mimics patient-derived scaffolds (PDS) of breast cancer. Here, the biocompatible polysaccharide alginate was used as base material to generate scaffolds consisting of a 3D grid containing periostin and hydroxyapatite. Breast cancer cell lines (MCF7 and MDA-MB-231) produced similar phenotypes and gene expression levels of cancer stem cell, epithelial-mesenchymal transition, differentiation and proliferation markers when cultured on 3DPS and PDS, contrasting conventional 2D cultures. Importantly, cells cultured on 3DPS and PDS showed scaffold-specific responses to cytotoxic drugs (doxorubicin and 5-fluorouracil) that were different from 2D cultured cells. In conclusion, the data presented support the use of a tunable alginate-based 3DPS as a tumor model in breast cancer drug discovery.


Assuntos
Antineoplásicos , Neoplasias da Mama/metabolismo , Impressão Tridimensional , Alicerces Teciduais/química , Microambiente Tumoral/efeitos dos fármacos , Alginatos/química , Antineoplásicos/química , Antineoplásicos/farmacologia , Ensaios de Seleção de Medicamentos Antitumorais , Feminino , Humanos , Medicina de Precisão , Células Tumorais Cultivadas
6.
J Mater Sci Mater Med ; 21(10): 2743-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20680412

RESUMO

Previous studies have shown that crystalline titanium oxide is in vitro bioactive and that there are differences in the HA formation mechanism depending on the crystalline direction of the titanium oxide surface. In the present study, the early adsorption of calcium and phosphate ions on three different surface directions of the single-crystal rutile TiO(2) substrate has been investigated. A crucial step in the nucleation of HA is believed to be the adsorption of Ca(2+) and PO(4)(3-) from phosphate buffer solutions. The (001), (100) and (110) single crystalline rutile surfaces were soaked in phosphate buffer saline solution for 10 min, 1 h and 24 h at 37°C. The surfaces were then analyzed using time-of-flight secondary ion mass spectrometry (TOF-SIMS) and X-ray photoelectron spectroscopy (XPS). The results show that the adsorption of Ca(2+) and PO(4)(3-) is faster on the (001) and (100) surfaces than on the (110) surface. This study also shows that TOF-SIMS can be used as a tool to better understand the adsorption of calcium and phosphate ions and the growth mechanism of HA. This knowledge could be used to tailor new bioactive surfaces for better biological reaction.


Assuntos
Materiais Biocompatíveis/síntese química , Durapatita/síntese química , Titânio/química , Adsorção , Materiais Biocompatíveis/química , Cristalização , Durapatita/química , Teste de Materiais , Modelos Químicos , Espectroscopia Fotoeletrônica , Espectrometria de Massa de Íon Secundário , Propriedades de Superfície
7.
Anal Chem ; 81(2): 662-8, 2009 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-19140778

RESUMO

We describe a new method for simultaneously collecting particles in exhaled air for subsequent chemical analysis and measuring their size distribution. After forced exhalation, particles were counted and collected in spots on silicon wafers with a cascade impactor. Several phospholipids were identified by time-of-flight secondary ion mass spectrometric analysis of the collected spots, suggesting that the particles originated from the lower airways. The amount of particles collected in ten exhalations was sufficient for characterizing the phospholipid composition. The feasibility of the technique in respiratory research is demonstrated by analysis of the phospholipid composition of exhaled particles from healthy controls, patients with asthma, and patients with cystic fibrosis. We believe this technology will be useful for monitoring patients with respiratory disease and has a high potential to detect new biomarkers in exhaled air.


Assuntos
Testes Respiratórios/métodos , Fosfolipídeos/análise , Adulto , Asma/diagnóstico , Biomarcadores/análise , Fibrose Cística/diagnóstico , Expiração , Feminino , Humanos , Masculino , Espectrometria de Massas/métodos , Pessoa de Meia-Idade , Monitorização Fisiológica , Testes de Função Respiratória
8.
Rapid Commun Mass Spectrom ; 23(17): 2741-53, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19639617

RESUMO

In recent years, time-of-flight secondary ion mass spectrometry (ToF-SIMS) with cluster ion sources has opened new perspectives for the analysis of lipid biomarkers in geobiology and organic geochemistry. However, published ToF-SIMS reference spectra of relevant compounds are still sparse, and the influence of the chemical environment (matrix) on the ionisation of molecules and their fragmentation is still not well explored. This study presents ToF-SIMS spectra of eight glycerolipids as common target compounds in biomarker studies, namely ester- and ether-bound phosphatidylethanolamine, ester- and ether-bound phosphatidylcholine, ester-bound phosphatidylglycerol, ester- and ether-bound diglycerides and archaeol, obtained with a Bi(3) (+) cluster ion source. For all of these compounds, the spectra obtained in positive and negative analytical modes showed characteristic fragments that could clearly be assigned to e.g. molecular ions, functional groups and alkyl chains. By comparison with the reference spectra, it was possible to track some of these lipids in a pre-characterised organic extract and in cryosections of microbial mats. The results highlight the potential of ToF-SIMS for the laterally resolved analysis of organic biomarkers in environmental materials. The identification of the target compounds, however, may be hampered by matrix effects (e.g. adduct formation) and often require careful consideration of all spectral features and taking advantage of the molecular imaging capability of ToF-SIMS.


Assuntos
Glicerofosfolipídeos/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Archaea/química , Bactérias/química , Células Eucarióticas/química
9.
J Orthop Res ; 35(5): 1113-1122, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27341064

RESUMO

Osseointegrated transfemoral amputation prostheses have proven successful as an alternative method to the conventional socket-type prostheses. The method improves prosthetic use and thus increases the demands imposed on the bone-implant system. The hypothesis of the present study was that the loads applied to the bone-anchored implant system of amputees would result in locations of high stress and strain transfer to the bone tissue and thus contribute to complications such as unfavourable bone remodeling and/or elevated inflammatory response and/or compromised sealing function at the tissue-abutment interface. In the study, site-specific loading measurements were made on amputees and used as input data in finite element analyses to predict the stress and strain distribution in the bone tissue. Furthermore, a tissue sample retrieved from a patient undergoing implant revision was characterized in order to evaluate the long-term tissue response around the abutment. Within the limit of the evaluated bone properties in the present experiments, it is concluded that the loads applied to the implant system may compromise the sealing function between the bone and the abutment, contributing to resorption of the bone in direct contact with the abutment at the most distal end. This was supported by observations in the retrieved clinical sample of bone resorption and the formation of a soft tissue lining along the abutment interface. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1113-1122, 2017.


Assuntos
Membros Artificiais , Fêmur/fisiologia , Perna (Membro)/fisiologia , Adulto , Idoso , Feminino , Fêmur/diagnóstico por imagem , Análise de Elementos Finitos , Humanos , Masculino , Pessoa de Meia-Idade , Suporte de Carga , Microtomografia por Raio-X
10.
Acta Biomater ; 36: 296-309, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27000553

RESUMO

UNLABELLED: In orthopaedic surgery, cobalt chromium (CoCr) based alloys are used extensively for their high strength and wear properties, but with concerns over stress shielding and bone resorption due to the high stiffness of CoCr. The structural stiffness, principally related to the bulk and the elastic modulus of the material, may be lowered by appropriate design modifications, to reduce the stiffness mismatch between metal/alloy implants and the adjacent bone. Here, 3D printed CoCr and Ti6Al4V implants of similar macro-geometry and interconnected open-pore architecture prepared by electron beam melting (EBM) were evaluated following 26week implantation in adult sheep femora. Despite higher total bone-implant contact for Ti6Al4V (39±4%) than CoCr (27±4%), bone formation patterns were similar, e.g., densification around the implant, and gradual ingrowth into the porous network, with more bone in the outer half (periphery) than the inner half (centre). Raman spectroscopy revealed no major differences in mineral crystallinity, the apatite-to-collagen ratio, or the carbonate-to-phosphate ratio. Energy dispersive X-ray spectroscopy showed similar Ca/P ratio of the interfacial tissue adjacent to both materials. Osteocytes made direct contact with CoCr and Ti6Al4V. While osteocyte density and distribution in the new-formed bone were largely similar for the two alloys, higher osteocyte density was observed at the periphery of the porous network for CoCr, attributable to slower remodelling and a different biomechanical environment. The results demonstrate the possibility to achieve bone ingrowth into open-pore CoCr constructs, and attest to the potential for fabricating customised osseointegrated CoCr implants for load-bearing applications. STATEMENT OF SIGNIFICANCE: Although cobalt chromium (CoCr) based alloys are used extensively in orthopaedic surgery, stress shielding due to the high stiffness of CoCr is of concern. To reduce the stiffness mismatch between CoCr and bone, CoCr and Ti6Al4V implants having an interconnected open-pore architecture were prepared by electron beam melting (EBM). After six months of submerged healing in sheep, both alloys showed similar patterns of bone formation, with densification around the implant and gradual ingrowth into the porous network. The molecular and elemental composition of the interfacial tissue was similar for both alloys. Osteocytes made direct contact with both alloys, with similar overall osteocyte density and distribution. The work attests to the potential for achieving osseointegration of EBM manufactured porous CoCr implants.


Assuntos
Substitutos Ósseos/química , Interface Osso-Implante , Ligas de Cromo/química , Fêmur/metabolismo , Osteócitos/metabolismo , Ligas , Animais , Porosidade , Ovinos , Titânio/química
11.
Biomaterials ; 41: 106-21, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25522970

RESUMO

Infection constitutes a major risk for implant failure, but the reasons why biomaterial sites are more vulnerable than normal tissue are not fully elucidated. In this study, a soft tissue infection model was developed, allowing the analysis of cellular and molecular responses in each of the sub-compartments of the implant-tissue interface (on the implant surface, in the surrounding exudate and in the tissue). Smooth and nanostructured titanium disks with or without noble metal chemistry (silver, gold, palladium), and sham sites, were inoculated with Staphylococcus epidermidis and analysed with respect to number of viable bacteria, number, viability and gene expression of host cells, and using different morphological techniques after 4 h, 24 h and 72 h. Non-infected rats were controls. Results showed a transient inflammatory response at control sites, whereas bacterial administration resulted in higher recruitment of inflammatory cells (mainly polymorphonuclear), higher, continuous cell death and higher gene expression of tumour necrosis factor-alpha, interleukin-6, interleukin-8, Toll-like receptor 2 and elastase. At all time points, S. epidermidis was predominantly located in the interface zone, extra- and intracellularly, and lower levels were detected on the implants compared with surrounding exudate. This model allows detailed analysis of early events in inflammation and infection associated to biomaterials in vivo leading to insights into host defence mechanisms in biomaterial-associated infections.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Inflamação/patologia , Infecções Estafilocócicas/microbiologia , Infecções Estafilocócicas/patologia , Staphylococcus epidermidis/efeitos dos fármacos , Animais , Forma Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Contagem de Colônia Microbiana , Modelos Animais de Doenças , Feminino , Regulação da Expressão Gênica/efeitos dos fármacos , Teste de Materiais , Microscopia de Força Atômica , Nanoestruturas/ultraestrutura , Espectroscopia Fotoeletrônica , Projetos Piloto , Próteses e Implantes , Ratos Sprague-Dawley , Staphylococcus epidermidis/crescimento & desenvolvimento , Staphylococcus epidermidis/ultraestrutura , Propriedades de Superfície
12.
Acta Biomater ; 20: 165-175, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25848727

RESUMO

Commercially pure titanium (cp-Ti) is regarded as the state-of-the-art material for bone-anchored dental devices, whereas the mechanically stronger alloy (Ti-6Al-4V), made of titanium, aluminum (Al) and vanadium (V), is regarded as the material of choice for high-load applications. There is a call for the development of new alloys, not only to eliminate the potential toxic effect of Al and V but also to meet the challenges imposed on dental and maxillofacial reconstructive devices, for example. The present work evaluates a novel, dual-stage, acid-etched, Ti-Ta-Nb-Zr alloy implant, consisting of elements that create low toxicity, with the potential to promote osseointegration in vivo. The alloy implants (denoted Ti-Ta-Nb-Zr) were evaluated after 7 days and 28 days in a rat tibia model, with reference to commercially pure titanium grade 4 (denoted Ti). Analyses were performed with respect to removal torque, histomorphometry and gene expression. The Ti-Ta-Nb-Zr showed a significant increase in implant stability over time in contrast to the Ti. Further, the histological and gene expression analyses suggested faster healing around the Ti-Ta-Nb-Zr, as judged by the enhanced remodeling, and mineralization, of the early-formed woven bone and the multiple positive correlations between genes denoting inflammation, bone formation and remodeling. Based on the present experiments, it is concluded that the Ti-Ta-Nb-Zr alloy becomes osseointegrated to at least a similar degree to that of pure titanium implants. This alloy is therefore emerging as a novel implant material for clinical evaluation.


Assuntos
Ligas/farmacologia , Osso e Ossos/efeitos dos fármacos , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Calcificação Fisiológica/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Contagem de Células , Morte Celular/efeitos dos fármacos , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Regulação da Expressão Gênica/efeitos dos fármacos , Implantes Experimentais , Masculino , Camundongos , Microscopia Eletrônica de Varredura , Espectroscopia Fotoeletrônica , Ratos Sprague-Dawley , Propriedades de Superfície
13.
J Chromatogr A ; 1023(1): 49-56, 2004 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-14760849

RESUMO

In this paper, the novel application of time-of-flight secondary ion mass spectrometry (TOF-SIMS) for qualitative and semi-quantitative investigation of the surface chemistry of separation media based on beaded agarose is reported. Five different media were studied: DEAE Sepharose Fast Flow, Q Sepharose Fast Flow, SP Sepharose Fast Flow, Phenyl Sepharose Fast Flow at ligand densities between 7 and 33% (w/w) and the base matrix Sepharose 6 Fast Flow. The obtained TOF-SIMS spectra reveal significant chemical information regarding the ligands (DEAE, Q, SP and Phenyl) which are covalently attached to the agarose-based matrix Sepharose 6 Fast Flow. For the anion-exchange media (DEAE and Q Sepharose Fast Flow), the positive TOF-SIMS spectra yielded several strong characteristic fragment peaks from the amine ligands. Structural information was obtained, e.g. from the peak at m/z 173.20, originating from the ion structure [(C2H5)2NCH2CH2NH(C2H5)2l+, which shows that the ligand in DEAE Sepharose Fast Flow is composed of both tertiary and quaternary amines. The positive spectrum of Phenyl Sepharose Fast Flow contained major fragments both from the base matrix and the ligand. The cation-exchanger (SP Sepharose Fast Flow) gave rise to a positive spectrum resembling that of the base matrix (Sepharose 6 Fast Flow) but with a different intensity pattern of the matrix fragments. In addition, peaks with low intensity at m/z 109.94, 125.94 and 139.95 corresponding to Na2SO2+, Na2SO3+ and Na2SO3CH2+, respectively, were observed. The positive TOF-SIMS spectrum of Sepharose 6 Fast Flow contains a large number of fragments in the mass range up to m/z 200 identified as CxHyOz and CxHy structures. The results clearly show that positive TOF-SIMS spectra of different media based on Sepharose 6 Fast Flow are strongly influenced by the ligand coupled to the matrix. The negative TOF-SIMS spectra contained several ligand-specific, characteristic peaks for the cation-exchanger, having sulphonate as the ion-exchange group. Negative fragments such as S-, SO-, SO2-, SO3-, C2H3SO3-, C3H5SO3- and OC3H5SO3- were observed. Phenyl Sepharose Fast Flow, which has an uncharged group (Phenyl) coupled to the agarose matrix yielded one ligand-related peak corresponding to the C6H5O- fragment. DEAE and Q ligands could only be identified by the appearance of the fragments CN- and CNO- in the negative spectrum. However, a strong peak corresponding to the counter ion (Cl-) was observed. TOF-SIMS analysis can also be used for the investigation of residues from the coupling procedure that bonds the ligands to the matrix. One example is the observation of bromine peaks in the negative spectrum of Q Sepharose Fast Flow. Furthermore, it has also been shown that different ligand concentrations of Phenyl Sepharose Fast Flow can easily be detected by TOF-SIMS analysis. Information regarding the difference between the ligand density on the surface of the beads and in the bulk can also be obtained. However, spectra registered on the outermost surface and on the pore surface (crushed beads) of DEAE Sepharose Fast Flow clearly show that the agarose and the DEAE groups are homogeneously distributed in the beads.


Assuntos
Espectrometria de Massas/métodos , Sefarose/química
14.
J Mech Behav Biomed Mater ; 34: 83-92, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24566379

RESUMO

Osseointegration is a prerequisite for achieving a stable long-term fixation and load-bearing capacity of bone anchored implants. Removal torque measurements are often used experimentally to evaluate the fixation of osseointegrated screw-shaped implants. However, a detailed understanding of the way different factors influence the result of removal torque measurements is lacking. The present study aims to identify the main factors contributing to anchorage. Individual factors important for implant fixation were identified using a model system with an experimental design in which cylindrical or screw-shaped samples were embedded in thermosetting polymers, in order to eliminate biological variation. Within the limits of the present study, it is concluded that surface topography and the mechanical properties of the medium surrounding the implant affect the maximum removal torque. In addition to displaying effects individually, these factors demonstrate interplay between them. The rotational speed was found not to influence the removal torque measurements within the investigated range.


Assuntos
Próteses e Implantes , Torque , Osseointegração , Poliuretanos , Propriedades de Superfície , Temperatura
15.
Int J Nanomedicine ; 9: 775-94, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24550671

RESUMO

The role of material surface properties in the direct interaction with bacteria and the indirect route via host defense cells is not fully understood. Recently, it was suggested that nanostructured implant surfaces possess antimicrobial properties. In the current study, the adhesion and biofilm formation of Staphylococcus epidermidis and human monocyte adhesion and activation were studied separately and in coculture in different in vitro models using smooth gold and well-defined nanostructured gold surfaces. Two polystyrene surfaces were used as controls in the monocyte experiments. Fluorescent viability staining demonstrated a reduction in the viability of S. epidermidis close to the nanostructured gold surface, whereas the smooth gold correlated with more live biofilm. The results were supported by scanning electron microscopy observations, showing higher biofilm tower formations and more mature biofilms on smooth gold compared with nanostructured gold. Unstimulated monocytes on the different substrates demonstrated low activation, reduced gene expression of pro- and anti-inflammatory cytokines, and low cytokine secretion. In contrast, stimulation with opsonized zymosan or opsonized live S. epidermidis for 1 hour significantly increased the production of reactive oxygen species, the gene expression of tumor necrosis factor-α (TNF-α), interleukin-1ß (IL-1ß), IL-6, and IL-10, as well as the secretion of TNF-α, demonstrating the ability of the cells to elicit a response and actively phagocytose prey. In addition, cells cultured on the smooth gold and the nanostructured gold displayed a different adhesion pattern and a more rapid oxidative burst than those cultured on polystyrene upon stimulation. We conclude that S. epidermidis decreased its viability initially when adhering to nanostructured surfaces compared with smooth gold surfaces, especially in the bacterial cell layers closest to the surface. In contrast, material surface properties neither strongly promoted nor attenuated the activity of monocytes when exposed to zymosan particles or S. epidermidis.


Assuntos
Biofilmes/crescimento & desenvolvimento , Nanopartículas Metálicas , Monócitos/imunologia , Staphylococcus epidermidis/fisiologia , Aderência Bacteriana , Citocinas/genética , Expressão Gênica , Ouro , Humanos , Nanopartículas Metálicas/ultraestrutura , Microscopia Eletrônica de Varredura , Monócitos/fisiologia , Monócitos/ultraestrutura , Nanomedicina , Fagocitose , Poliestirenos , Staphylococcus epidermidis/imunologia , Propriedades de Superfície
16.
Int J Nanomedicine ; 9: 2499-515, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24904210

RESUMO

BACKGROUND: Patterning medical devices at the nanoscale level enables the manipulation of cell behavior and tissue regeneration, with topographic features recognized as playing a significant role in the osseointegration of implantable devices. METHODS: In this study, we assessed the ability of titanium-coated hemisphere-like topographic nanostructures of different sizes (approximately 50, 100, and 200 nm) to influence the morphology, proliferation, and osteogenic differentiation of human mesenchymal stem cells (hMSCs). RESULTS: We found that the proliferation and osteogenic differentiation of hMSCs was influenced by the size of the underlying structures, suggesting that size variations in topographic features at the nanoscale level, independently of chemistry, can be exploited to control hMSC behavior in a size-dependent fashion. CONCLUSION: Our studies demonstrate that colloidal lithography, in combination with coating technologies, can be exploited to investigate the cell response to well defined nanoscale topography and to develop next-generation surfaces that guide tissue regeneration and promote implant integration.


Assuntos
Regeneração Tecidual Guiada/métodos , Células-Tronco Mesenquimais/citologia , Osteoblastos/citologia , Osteogênese/fisiologia , Engenharia Tecidual/métodos , Titânio/química , Absorção Fisico-Química , Células Cultivadas , Humanos , Teste de Materiais , Impressão Molecular/métodos , Tamanho da Partícula , Fotografação/métodos , Propriedades de Superfície
17.
Biomed Mater ; 7(4): 045018, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22736143

RESUMO

The dissolution and release of active ions from ion-doped apatites is currently gaining interest due to indications of a beneficial biologic response. The release of ions from apatite coatings is important because it influences the biological effect of these types of materials. In this study the ion release from three different ion-doped apatite coatings (iHA coatings), SrCaP, SiHA and FHA, has been studied. The coatings were prepared by a mineralization method based on immersion in modified PBS solutions containing additions of Sr, Si or F. The kinetics of ion release from the iHA coatings were studied in two different media with and without calcium and phosphate ions (phosphate buffer saline solution (PBS) and Tris-HCl). The amount of cumulative release of Sr, Si and F ions from the iHA coatings was SrCaP>SiHA>FHA in Tris-HCl, which could be also be related to the solubility for these iHA coatings. According to analysis using the Korsmeyer-Peppas model, the release of ions from the coatings was in most cases controlled by a combination of Fickian diffusion and dissolution of the coatings. The morphologies of the iHA coatings were not markedly changed after immersion in Tris-HCl. In the phosphate buffer solution, there was a concurrent redeposition of new apatite crystals on the surface of all of the iHA coatings, which means there were both a dissolution and a remineralization process acting, ultimately controlling the ion release rate.


Assuntos
Fosfatos de Cálcio/química , Materiais Revestidos Biocompatíveis/química , Íons/análise , Apatitas/química , Materiais Biocompatíveis/química , Cálcio/química , Difusão , Durapatita/química , Flúor/química , Concentração de Íons de Hidrogênio , Cinética , Teste de Materiais , Silício/química , Estrôncio/química , Propriedades de Superfície , Fatores de Tempo , Titânio/química , Difração de Raios X
18.
J Biomed Mater Res B Appl Biomater ; 100(1): 75-81, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21954024

RESUMO

Biomolecules and surfactants are believed to be the key factors for reconstruction of tooth enamel and preparation of fluoride hydroxyapatite coating with enamel-like structure on dental implants. We have developed an alternative surfactant-free biomimetic method to stimulate growth of fluoride substituted hydroxyapatite coatings with highly packed and aligned structure on metallic substrates. Oxidized titanium plates were chosen as the substrates. The biomimetic fluoride hydroxyapatite was prepared by immersing the pretreated Ti plates into the phosphate-buffered solution with Ca(2+), H(2)PO(4)(-), HPO(4)(2-), and F(-). The pH value was controlled at 7.4 at the beginning. Every titanium plate (10 mm × 10 mm × 1 mm) was soaked into 20 mL of ion doped phosphate buffered solution in sealed plastic bottles, kept at 37°C or 60°C without stirring for time periods of 1 day to 2 weeks. After immersion, the samples were removed from the solution, rinsed with deionized water and allowed to dry in air. The fluoride substituted hydroxyapatite layer, composed of needle-like crystallites with the diameter of 10-20 nm, was well-organized and tightly packed. XRD results showed a sharper and stronger (002) peak, which could be used to explain that there was a preferable orientation along the c axis. The coating could be reconstructed on the former layer if the mineralization process was repeated, and the structure of the coating could be preserved. The method could be used to construct well organized fluoride substitute hydroxyapatite coating on metal implants.


Assuntos
Materiais Biomiméticos/síntese química , Materiais Revestidos Biocompatíveis/síntese química , Durapatita/síntese química , Fluoretos/síntese química , Materiais Biomiméticos/química , Materiais Revestidos Biocompatíveis/química , Durapatita/química , Fluoretos/química , Propriedades de Superfície , Titânio/química
19.
Case Rep Endocrinol ; 2012: 842357, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22953073

RESUMO

Patients with Graves' disease can be medically prepared before surgery in different ways, which may have various effects on iodine stores. Thyroid specimens were collected at surgery from two patients pretreated with propylthiouracil (PTU) and stable iodine, respectively. A quantitative analysis of iodine content was performed using X-ray fluorescence (XRF) in frozen tissue and a qualitative analysis of aldehyde-fixed material with Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS). Iodine concentrations were 0.9 mg/mL and 0.5 mg/mL in the thyroid tissue from the patients treated with PTU and stable iodine respectively. TOF-SIMS showed iodine in the follicle lumina in both. However, in the PTU case, iodine was also seen within the thyrocytes indicating accumulation of iodinated compounds from uninhibited hormone release. XRF and TOF-SIMS can be used to follow iodine distribution within the thyroid and the intricate processes following the different medical treatment alternatives in Graves' disease.

20.
J R Soc Interface ; 9(72): 1615-24, 2012 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-22279159

RESUMO

The aim of this study was to evaluate the bone tissue response to strontium- and silicon-substituted apatite (Sr-HA and Si-HA) modified titanium (Ti) implants. Sr-HA, Si-HA and HA were grown on thermally oxidized Ti implants by a biomimetic process. Oxidized implants were used as controls. Surface properties, i.e. chemical composition, surface thickness, morphology/pore characteristics, crystal structure and roughness, were characterized with various analytical techniques. The implants were inserted in rat tibiae and block biopsies were prepared for histology, histomorphometry and scanning electron microscopy analysis. Histologically, new bone formed on all implant surfaces. The bone was deposited directly onto the Sr-HA and Si-HA implants without any intervening soft tissue. The statistical analysis showed significant higher amount of bone-implant contact (BIC) for the Si-doped HA modification (P = 0.030), whereas significant higher bone area (BA) for the Sr-doped HA modification (P = 0.034), when compared with the non-doped HA modification. The differences were most pronounced at the early time point. The healing time had a significant impact for both BA and BIC (P < 0.001). The present results show that biomimetically prepared Si-HA and Sr-HA on Ti implants provided bioactivity and promoted early bone formation.


Assuntos
Apatitas , Materiais Biomiméticos , Substitutos Ósseos , Osso e Ossos/metabolismo , Materiais Revestidos Biocompatíveis , Osteogênese , Titânio , Animais , Masculino , Teste de Materiais/métodos , Ratos , Ratos Sprague-Dawley , Silício , Estrôncio , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa