Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
IEEE Trans Control Syst Technol ; 28(1): 3-15, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32699492

RESUMO

Streaming data from continuous glucose monitoring (CGM) systems enable the recursive identification of models to improve estimation accuracy for effective predictive glycemic control in patients with type-1 diabetes. A drawback of conventional recursive identification techniques is the increase in computational requirements, which is a concern for online and real-time applications such as the artificial pancreas systems implemented on handheld devices and smartphones where computational resources and memory are limited. To improve predictions in such computationally constrained hardware settings, efficient adaptive kernel filtering algorithms are developed in this paper to characterize the nonlinear glycemic variability by employing a sparsification criterion based on the information theory to reduce the computation time and complexity of the kernel filters without adversely deteriorating the predictive performance. Furthermore, the adaptive kernel filtering algorithms are designed to be insensitive to abnormal CGM measurements, thus compensating for measurement noise and disturbances. As such, the sparsification-based real-time model update framework can adapt the prediction models to accurately characterize the time-varying and nonlinear dynamics of glycemic measurements. The proposed recursive kernel filtering algorithms leveraging sparsity for improved computational efficiency are applied to both in-silico and clinical subjects, and the results demonstrate the effectiveness of the proposed methods.

2.
Comput Chem Eng ; 112: 57-69, 2018 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-30287976

RESUMO

Artificial pancreas (AP) systems provide automated regulation of blood glucose concentration (BGC) for people with type 1 diabetes (T1D). An AP includes three components: a continuous glucose monitoring (CGM) sensor, a controller calculating insulin infusion rate based on the CGM signal, and a pump delivering the insulin amount calculated by the controller to the patient. The performance of the AP system depends on successful operation of these three components. Many APs use model predictive controllers that rely on models to predict BGC and to calculate the optimal insulin infusion rate. The performance of model-based controllers depends on the accuracy of the models that is affected by large dynamic changes in glucose-insulin metabolism or equipment performance that may move the operating conditions away from those used in developing the models and designing the control system. Sensor errors and missing signals will cause calculation of erroneous insulin infusion rates. And the performance of the controller may vary at each sampling step and each period (meal, exercise, and sleep), and from day to day. Here we describe a multi-level supervision and controller modification (ML-SCM) module is developed to supervise the performance of the AP system and retune the controller. It supervises AP performance in 3 time windows: sample level, period level, and day level. At sample level, an online controller performance assessment sub-module will generate controller performance indexes to evaluate various components of the AP system and conservatively modify the controller. A sensor error detection and signal reconciliation module will detect sensor error and reconcile the CGM sensor signal at each sample. At period level, the controller performance is evaluated with information collected during a certain time period and the controller is tuned more aggressively. At the day level, the daily CGM ranges are further analyzed to determine the adjustable range of controller parameters used for sample level and period level. Thirty subjects in the UVa/Padova metabolic simulator were used to evaluate the performance of the ML-SCM module and one clinical experiment is used to illustrate its performance in a clinical environment. The results indicate that the AP system with an ML-SCM module has a safer range of glucose concentration distribution and more appropriate insulin infusion rate suggestions than an AP system without the ML-SCM module.

3.
Control Eng Pract ; 71: 129-141, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29276347

RESUMO

Accurate predictions of glucose concentrations are necessary to develop an artificial pancreas (AP) system for people with type 1 diabetes (T1D). In this work, a novel glucose forecasting paradigm based on a model fusion strategy is developed to accurately characterize the variability and transient dynamics of glycemic measurements. To this end, four different adaptive filters and a fusion mechanism are proposed for use in the online prediction of future glucose trajectories. The filter fusion mechanism is developed based on various prediction performance indexes to guide the overall output of the forecasting paradigm. The efficiency of the proposed model fusion based forecasting method is evaluated using simulated and clinical datasets, and the results demonstrate the capability and prediction accuracy of the data-based fusion filters, especially in the case of limited data availability. The model fusion framework may be used in the development of an AP system for glucose regulation in patients with T1D.

4.
AIChE J ; 65(2): 629-639, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31447487

RESUMO

Erroneous information from sensors affect process monitoring and control. An algorithm with multiple model identification methods will improve the sensitivity and accuracy of sensor fault detection and data reconciliation (SFD&DR). A novel SFD&DR algorithm with four types of models including outlier robust Kalman filter, locally weighted partial least squares, predictor-based subspace identification, and approximate linear dependency-based kernel recursive least squares is proposed. The residuals are further analyzed by artificial neural networks and a voting algorithm. The performance of the SFD&DR algorithm is illustrated by clinical data from artificial pancreas experiments with people with diabetes. The glucose-insulin metabolism has time-varying parameters and nonlinearities, providing a challenging system for fault detection and data reconciliation. Data from 17 clinical experiments collected over 896 hours were analyzed; the results indicate that the proposed SFD&DR algorithm is capable of detecting and diagnosing sensor faults and reconciling the erroneous sensor signals with better model-estimated values.

5.
J Diabetes Sci Technol ; 12(3): 639-649, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29566547

RESUMO

BACKGROUND: The artificial pancreas (AP) system, a technology that automatically administers exogenous insulin in people with type 1 diabetes mellitus (T1DM) to regulate their blood glucose concentrations, necessitates the estimation of the amount of active insulin already present in the body to avoid overdosing. METHOD: An adaptive and personalized plasma insulin concentration (PIC) estimator is designed in this work to accurately quantify the insulin present in the bloodstream. The proposed PIC estimation approach incorporates Hovorka's glucose-insulin model with the unscented Kalman filtering algorithm. Methods for the personalized initialization of the time-varying model parameters to individual patients for improved estimator convergence are developed. Data from 20 three-days-long closed-loop clinical experiments conducted involving subjects with T1DM are used to evaluate the proposed PIC estimation approach. RESULTS: The proposed methods are applied to the clinical data containing significant disturbances, such as unannounced meals and exercise, and the results demonstrate the accurate real-time estimation of the PIC with the root mean square error of 7.15 and 9.25 mU/L for the optimization-based fitted parameters and partial least squares regression-based testing parameters, respectively. CONCLUSIONS: The accurate real-time estimation of PIC will benefit the AP systems by preventing overdelivery of insulin when significant insulin is present in the bloodstream.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/sangue , Modelos Teóricos , Pâncreas Artificial , Adolescente , Adulto , Algoritmos , Glicemia/análise , Automonitorização da Glicemia , Simulação por Computador , Feminino , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Masculino , Adulto Jovem
6.
J Diabetes Sci Technol ; 12(5): 953-966, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30060699

RESUMO

BACKGROUND: Despite the recent advancements in the modeling of glycemic dynamics for type 1 diabetes mellitus, automatically considering unannounced meals and exercise without manual user inputs remains challenging. METHOD: An adaptive model identification technique that incorporates exercise information and estimates of the effects of unannounced meals obtained automatically without user input is proposed in this work. The effects of the unknown consumed carbohydrates are estimated using an individualized unscented Kalman filtering algorithm employing an augmented glucose-insulin dynamic model, and exercise information is acquired from noninvasive physiological measurements. The additional information on meals and exercise is incorporated with personalized estimates of plasma insulin concentration and glucose measurement data in an adaptive model identification algorithm. RESULTS: The efficacy of the proposed personalized and adaptive modeling algorithm is demonstrated using clinical data involving closed-loop experiments of the artificial pancreas system, and the results demonstrate accurate glycemic modeling with the average root-mean-square error (mean absolute error) of 25.50 mg/dL (18.18 mg/dL) for six-step (30 minutes ahead) predictions. CONCLUSIONS: The approach presented is able to identify reliable time-varying individualized glucose-insulin models.


Assuntos
Algoritmos , Aprendizado de Máquina , Pâncreas Artificial , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Exercício Físico/fisiologia , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Sistemas de Infusão de Insulina , Refeições
7.
Diabetes Technol Ther ; 20(10): 662-671, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30188192

RESUMO

BACKGROUND: Exercise challenges people with type 1 diabetes in controlling their glucose concentration (GC). A multivariable adaptive artificial pancreas (MAAP) may lessen the burden. METHODS: The MAAP operates without any user input and computes insulin based on continuous glucose monitor and physical activity signals. To analyze performance, 18 60-h closed-loop experiments with 96 exercise sessions with three different protocols were completed. Each day, the subjects completed one resistance and one treadmill exercise (moderate continuous training [MCT] or high-intensity interval training [HIIT]). The primary outcome is time spent in each glycemic range during the exercise + recovery period. Secondary measures include average GC and average change in GC during each exercise modality. RESULTS: The GC during exercise + recovery periods were within the euglycemic range (70-180 mg/dL) for 69.9% of the time and within a safe glycemic range for exercise (70-250 mg/dL) for 93.0% of the time. The exercise sessions are defined to begin 30 min before the start of exercise and end 2 h after start of exercise. The GC were within the severe hypoglycemia (<55 mg/dL), moderate hypoglycemia (55-70 mg/dL), moderate hyperglycemia (180-250 mg/dL), and severe hyperglycemia (>250 mg/dL) for 0.9%, 1.3%, 23.1%, and 4.8% of the time, respectively. The average GC decline during exercise differed with exercise type (P = 0.0097) with a significant difference between the MCT and resistance (P = 0.0075). To prevent large GC decreases leading to hypoglycemia, MAAP recommended carbohydrates in 59% of MCT, 50% of HIIT, and 39% of resistance sessions. CONCLUSIONS: A consistent GC decline occurred in exercise and recovery periods, which differed with exercise type. The average GC at the start of exercise was above target (185.5 ± 56.6 mg/dL for MCT, 166.9 ± 61.9 mg/dL for resistance training, and 171.7 ± 41.4 mg/dL HIIT), making a small decrease desirable. Hypoglycemic events occurred in 14.6% of exercise sessions and represented only 2.22% of the exercise and recovery period.


Assuntos
Exercício Físico/fisiologia , Pâncreas Artificial , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/terapia , Feminino , Humanos , Hipoglicemia/sangue , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Bombas de Infusão , Insulina/administração & dosagem , Insulina/uso terapêutico , Masculino , Treinamento Resistido , Resultado do Tratamento , Adulto Jovem
8.
Diabetes Technol Ther ; 20(3): 235-246, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29406789

RESUMO

BACKGROUND: Automatically attenuating the postprandial rise in the blood glucose concentration without manual meal announcement is a significant challenge for artificial pancreas (AP) systems. In this study, a meal module is proposed to detect the consumption of a meal and to estimate the amount of carbohydrate (CHO) intake. METHODS: The meals are detected based on qualitative variables describing variation of continuous glucose monitoring (CGM) readings. The CHO content of the meals/snacks is estimated by a fuzzy system using CGM and subcutaneous insulin delivery data. The meal bolus amount is computed according to the patient's insulin to CHO ratio. Integration of the meal module into a multivariable AP system allows revision of estimated CHO based on knowledge about physical activity, sleep, and the risk of hypoglycemia before the final decision for a meal bolus is made. RESULTS: The algorithm is evaluated by using 117 meals/snacks in retrospective data from 11 subjects with type 1 diabetes. Sensitivity, defined as the percentage of correctly detected meals and snacks, is 93.5% for meals and 68.0% for snacks. The percentage of false positives, defined as the proportion of false detections relative to the total number of detected meals and snacks, is 20.8%. CONCLUSIONS: Integration of a meal detection module in an AP system is a further step toward an automated AP without manual entries. Detection of a consumed meal/snack and infusion of insulin boluses using an estimate of CHO enables the AP system to automatically prevent postprandial hyperglycemia.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Refeições , Pâncreas Artificial , Adolescente , Adulto , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Masculino , Período Pós-Prandial , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
9.
J Diabetes Sci Technol ; 10(6): 1236-1244, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27464755

RESUMO

Fear of hypoglycemia is a major concern for many patients with type 1 diabetes and affects patient decisions for use of an artificial pancreas system. We propose an alternative way for prevention of hypoglycemia by issuing predictive hypoglycemia alarms and encouraging patients to consume carbohydrates in a timely manner. The algorithm has been tested on 6 subjects (3 males and 3 females, age 24.2 ± 4.5 years, weight 79.2 ± 16.2 kg, height 172.7 ± 9.4 cm, HbA1C 7.3 ± 0.48%, duration of diabetes 209.2 ± 87.9 months) over 3-day closed-loop clinical experiments as part of a multivariable artificial pancreas control system. Over 6 three-day clinical experiments, there were only 5 real hypoglycemia episodes, of which only 1 hypoglycemia episode occurred due to being missed by the proposed algorithm. The average hypoglycemia alarms per day and per subject was 3. Average glucose value when the first alarms were triggered was recorded to be 117 ± 30.6 mg/dl. Average carbohydrate consumption per alarm was 14 ± 7.8 grams. Our results have shown that most low glucose concentrations can be predicted in advance and the glucose levels can be raised back to the desired levels by consuming an appropriate amount of carbohydrate. The proposed algorithm is able to prevent most hypoglycemic events by suggesting appropriate levels of carbohydrate consumption before the actual occurrence of hypoglycemia.


Assuntos
Algoritmos , Glicemia/análise , Alarmes Clínicos , Diabetes Mellitus Tipo 1/sangue , Hipoglicemia/prevenção & controle , Pâncreas Artificial , Adulto , Diabetes Mellitus Tipo 1/terapia , Carboidratos da Dieta , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa