RESUMO
Colorectal cancer (CRC) is the third most prevalent cancer to be diagnosed, and it has a substantial mortality rate. Despite numerous studies being conducted on CRC, it remains a significant health concern. The disease-free survival rates notably decrease as CRC progresses, emphasizing the urgency for effective diagnostic and therapeutic approaches. CRC development is caused by environmental factors, which mostly lead to the disruption of signaling pathways. Among these pathways, the Wingless/Integrated (Wnt) signaling pathway, Phosphatidylinositol 3-kinase/protein kinase B/mammalian target of rapamycin (PI3K/AKT/mTOR) signaling pathway, Mitogen-Activated Protein Kinase (MAPK) signaling pathway, Transforming Growth Factor-ß (TGF-ß) signaling pathway, and p53 signaling pathway are considered to be important. These signaling pathways are also regulated by non-coding RNAs (ncRNAs), including microRNAs (miRNAs), long non-coding RNAs (lncRNAs), and circular RNAs (circRNAs). They have emerged as crucial regulators of gene expression in CRC by changing their expression levels. The altered expression patterns of these ncRNAs have been implicated in CRC progression and development, suggesting their potential as diagnostic and therapeutic targets. This review provides an overview of the five key signaling pathways and regulation of ncRNAs involved in CRC pathogenesis that are studied to identify promising avenues for diagnosis and treatment strategies.
Assuntos
Neoplasias Colorretais , Regulação Neoplásica da Expressão Gênica , RNA não Traduzido , Transdução de Sinais , Humanos , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/genética , Neoplasias Colorretais/patologia , RNA não Traduzido/genética , RNA não Traduzido/metabolismo , MicroRNAs/genética , MicroRNAs/metabolismo , RNA Longo não Codificante/genética , RNA Longo não Codificante/metabolismo , AnimaisRESUMO
Dementia, a multifaceted neurological syndrome characterized by cognitive decline, poses significant challenges to daily functioning. The main causes of dementia, including Alzheimer's disease (AD), frontotemporal dementia (FTD), Lewy body dementia (LBD), and vascular dementia (VD), have different symptoms and etiologies. Genetic regulators, specifically non-coding RNAs (ncRNAs) such as microRNAs (miRNAs), long non-coding RNAs (lncRNAs), and circular RNAs (circRNAs), are known to play important roles in dementia pathogenesis. MiRNAs, small non-coding RNAs, regulate gene expression by binding to the 3' untranslated regions of target messenger RNAs (mRNAs), while lncRNAs and circRNAs act as molecular sponges for miRNAs, thereby regulating gene expression. The emerging concept of competing endogenous RNA (ceRNA) interactions, involving lncRNAs and circRNAs as competitors for miRNA binding, has gained attention as potential biomarkers and therapeutic targets in dementia-related disorders. This review explores the regulatory roles of ncRNAs, particularly miRNAs, and the intricate dynamics of ceRNA interactions, providing insights into dementia pathogenesis and potential therapeutic avenues.
Assuntos
Demência , Regulação da Expressão Gênica , MicroRNAs , RNA Circular , RNA Longo não Codificante , RNA não Traduzido , Humanos , Demência/genética , Demência/metabolismo , MicroRNAs/genética , MicroRNAs/metabolismo , RNA Circular/genética , RNA Circular/metabolismo , RNA Longo não Codificante/genética , RNA Longo não Codificante/metabolismo , RNA não Traduzido/genética , RNA não Traduzido/metabolismo , Animais , Biomarcadores , Doença de Alzheimer/genética , Doença de Alzheimer/metabolismoRESUMO
STATEMENT OF PROBLEM: Tooth preparation is an essential part of prosthetic dentistry; however, traditional evaluation methods involve subjective visual inspection that is prone to examiner variability. PURPOSE: The purpose of this study was to investigate a newly developed automated scoring and augmented reality (ASAR) visualization software program for evaluating tooth preparations. MATERIAL AND METHODS: A total of 122 tooth models (61 anterior and 61 posterior teeth) prepared by dental students were evaluated by using visual assessments that were conducted by students and an expert, and auto assessment that was performed with an ASAR software program by using a 3-dimensional (3D) point-cloud comparison method. The software program offered comprehensive functions, including generating detailed reports for individual test models, producing a simultaneous summary score report for all tested models, creating 3D color-coded deviation maps, and forming augmented reality quick-response (AR-QR) codes for online data storage with AR visualization. The reliability and efficiency of the evaluation methods were measured by comparing tooth preparation assessment scores and evaluation time. The data underwent statistical analysis using the Kruskal-Wallis test, followed by Mann-Whitney U tests for pairwise comparisons adjusted with the Benjamini-Hochberg method (α=.05). RESULTS: Significant differences were found across the evaluation methods and tooth types in terms of preparation scores and evaluation time (P<.001). A significant difference was observed between the auto- and student self-assessment methods (P<.001) in scoring both the anterior and posterior tooth preparations. However, no significant difference was found between the auto- and expert-assessment methods for the anterior (P=.085) or posterior (P=.14) tooth preparation scores. Notably, the auto-assessment method required significantly shorter time than the expert- and self-assessment methods (P<.001) for both tooth types. Additionally, significant differences in evaluation time between the anterior and posterior tooth were observed in both self- and expert-assessment methods (P<.001), whereas the evaluation times for both the tooth types with the auto-assessment method were statistically similar (P=.32). CONCLUSIONS: ASAR-based evaluation is comparable with expert-assessment while exhibiting significantly higher time efficiency. Moreover, AR-QR codes enhance learning and training experiences by facilitating online data storage and AR visualization.
Assuntos
Realidade Aumentada , Software , Humanos , Imageamento Tridimensional/métodos , Preparo Prostodôntico do Dente/métodos , Reprodutibilidade dos Testes , Modelos Dentários , Preparo do Dente/métodosRESUMO
INTRODUCTION: Virtual reality-based interactive simulation (VRIS) provides a safe and controlled environment for dental students and professionals to develop skills and knowledge. This study aimed to investigate the effectiveness of using the VRIS for prosthodontic practice and to explore the trends, application areas, and users' attitudes towards VRIS. MATERIALS AND METHODS: This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for searching studies published until 21 March 2023 that reported quantitative or qualitative learning outcomes related to the use of VRIS for dental prosthodontic practice and clinical training. The quality of the included studies was assessed using the Medical Education Research Study Quality Instrument (MERSQI) and Newcastle-Ottawa Scale-Education (NOS-E) tools. A random-effects meta-analysis was conducted to compare the intervention group (utilizing VRIS) and the control group (employing conventional prosthodontic training methods) based on performance skill scores and task completion time, with a significance level set at <.05. RESULTS: The meta-analysis revealed that the utilization of VRIS generally improves students' performance scores (SMD = 1.04; 95% CI, -0.35 to 2.44; I2 > 50%; p = .13) and reduces task completion time (SMD = -0.03; 95% CI, 1.39-7.72; I2 > 50%; p = .93). Notably, using VRIS significantly enhanced the performance scores in implant surgery practice (SMD = 0.26; 95% CI, 0.09-0.42; p < .05). Additionally, the VRIS method significantly reduced task completion time in the cavity restorative preparation task (SMD = -1.19; 95% CI, -1.85 to -0.53; p < .05). CONCLUSION: Engaging in practice with VRIS has the potential to enhance learning proficiency in prosthodontic education. The advantages associated with VRIS encompass the provision of immediate feedback, decreased task completion time, heightened confidence and motivation, accelerated skill acquisition, improved performance scores, and increased learning engagement.
RESUMO
AIM: The current study aimed to compare the responses and satisfaction reported by users with varying levels of experience when using different types of computer-aided design (CAD) software programs to design crowns. MATERIALS AND METHODS: A questionnaire was used to evaluate user responses to five domains (software visibility, 3Dscanned data preparation, crown design and adjustment, finish line registration, and overall experience) of various CAD software programs. The study included 50 undergraduate dental students (inexperienced group) and 50 dentists or dental technicians from two hospitals (experienced group). The participants used four different CAD software programs (Meshmixer, Exocad, BlueSkyPlan, and Dentbird) to design crowns and recorded the features using the questionnaire. Statistical analyses included one-way and two-way analysis of variance (ANOVA) tests to compare scores and verify the interaction between user response and experience. RESULT: User evaluation scores in the domains of software visibility and 3D-scanned data preparation varied between software programs (P < 0.001), with Exocad being favored by the experienced group. When evaluating crown design and finish line registration, Dentbird and Exocad scored significantly higher than the other software in both groups as they offered automation of the process using deep learning (P < 0.001). Two-way ANOVA showed that prior experience of using CAD significantly affected the users' responses to all queries (P < 0.001). CONCLUSION: User response and satisfaction varied with the type of CAD software used to design dental prostheses, with prior experience of using CAD playing a significant role. Automation of design functions can enhance user satisfaction with the software.
RESUMO
This technique presents a workflow that designs the custom surgical guide to cover a trephine bur using simple slicer software and three-dimensional (3D) printing to perform the semilunar technique. This method in autogenous bone grafting surgery harvests a thin layer of cortical bone in the donor site with a trephine bur. Its biologically favorable, round shape can be used as a shell to reconstruct the ridge with a 3D contour acceptable for future implant placement. A 78-year-old female patient required vertical and horizontal bone grafting for future implant placement due to the infection caused by the vertically fractured root of a premolar. The patient's cone beam computed tomography (CBCT) file was translated into a standard tessellation language (STL) file, and recipient and donor site models were created. Simulated surgery was done using the software first to detect any possible complications during surgery. The trephine bur planned for use in surgery was measured in necessary dimensions, and the values were added to create a guide for surgery in slicer software. Then, it was 3D-printed with a stereolithography (SLA) printer. After testing the fit of the guide, it was further tested on a fused filament fabrication (FFF) printed donor site model to check if the desired shape and size of the plate were acquired after harvest. Then, the plates were used for model surgery on the recipient site model. After no issues from the previous steps, the final patient surgery was approved and completed with success. This technique utilizes the SLA printing method to create the custom surgical guide for a trephine bur without using commercially available products. Moreover, it could be tested on FFF 3D-printed anatomical models to ensure its validity. With this innovative technique, clinicians can efficiently perform a semilunar technique, facilitating the surgery and improving patient care.
RESUMO
PURPOSE: This study aimed to examine the satisfaction of dental professionals, including dental students, dentists, and dental technicians, with computer-aided design (CAD) software performance using deep learning (DL) and explainable artificial intelligence (XAI)-based behavioral analysis concepts. MATERIALS AND METHODS: This study involved 436 dental professionals with diverse CAD experiences to assess their satisfaction with various dental CAD software programs. Through exploratory factor analysis, latent factors affecting user satisfaction were extracted from the observed variables. A multilayer perceptron artificial neural network (MLP-ANN) model was developed along with permutation feature importance analysis (PFIA) and the Shapley additive explanation (Shapley) method to gain XAI-based insights into individual factors' significance and contributions. RESULTS: The MLP-ANN model outperformed a standard logistic linear regression model, demonstrating high accuracy (95%), precision (84%), and recall rates (84%) in capturing complex psychological problems related to human attitudes. PFIA revealed that design adjustability was the most important factor impacting dental CAD software users' satisfaction. XAI analysis highlighted the positive impacts of features supporting the finish line and crown design, while the number of design steps and installation time had negative impacts. Notably, finish-line design-related features and the number of design steps emerged as the most significant factors. CONCLUSIONS: This study sheds light on the factors influencing dental professionals' decisions in using and selecting CAD software. This approach can serve as a proof-of-concept for applying DL-XAI-based behavioral analysis in dentistry and medicine, facilitating informed software selection and development.
RESUMO
BACKGROUND: The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently developed AR-assisted dental implant navigation system (AR navigation), which uses innovative image technology to directly visualize and track a presurgical plan over an actual surgical site, has attracted great interest. OBJECTIVE: This study is the first systematic review and meta-analysis study that aimed to assess the accuracy of dental implants placed by AR navigation and compare it with that of the widely used implant placement methods, including the freehand method (FH), template-based static guidance (TG), and conventional navigation (CN). METHODS: Individual search strategies were used in PubMed (MEDLINE), Scopus, ScienceDirect, Cochrane Library, and Google Scholar to search for articles published until March 21, 2022. This study was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered in the International Prospective Register of Systematic Reviews (PROSPERO) database. Peer-reviewed journal articles evaluating the positional deviations of dental implants placed using AR-assisted implant navigation systems were included. Cohen d statistical power analysis was used to investigate the effect size estimate and CIs of standardized mean differences (SMDs) between data sets. RESULTS: Among the 425 articles retrieved, 15 articles were considered eligible for narrative review, 8 articles were considered for single-arm meta-analysis, and 4 were included in a 2-arm meta-analysis. The mean lateral, global, depth, and angular deviations of the dental implant placed using AR navigation were 0.90 (95% CI 0.78-1.02) mm, 1.18 (95% CI 0.95-1.41) mm, 0.78 (95% CI 0.48-1.08) mm, and 3.96° (95% CI 3.45°-4.48°), respectively. The accuracy of AR navigation was significantly higher than that of the FH method (SMD=-1.01; 95% CI -1.47 to -0.55; P<.001) and CN method (SMD=-0.46; 95% CI -0.64 to -0.29; P<.001). However, the accuracies of the AR navigation and TG methods were similar (SMD=0.06; 95% CI -0.62 to 0.74; P=.73). CONCLUSIONS: The positional deviations of AR-navigated implant placements were within the safety zone, suggesting clinically acceptable accuracy of the AR navigation method. Moreover, the accuracy of AR implant navigation was comparable with that of the highly recommended dental implant-guided surgery method, TG, and superior to that of the conventional FH and CN methods. This review highlights the possibility of using AR navigation as an effective and accurate immersive surgical guide for dental implant placement.
Assuntos
Realidade Aumentada , Implantes Dentários , Cirurgiões , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , TecnologiaRESUMO
Circular RNAs (circRNAs) are a class of endogenous RNAs that control gene expression at the transcriptional and post-transcriptional levels. Recent studies have increasingly demonstrated that circRNAs act as novel diagnostic biomarkers and promising therapeutic targets for numerous cancer types by interacting with other non-coding RNAs such as microRNAs (miRNAs). The miRNAs are presented as crucial risk factors and regulatory elements in cancer by regulating the expression of their target genes. Some miRNAs are derived from transposable elements (MDTEs) that can transfer their location to another region of the genome. Genetic interactions between miRNAs and circular RNAs can form complex regulatory networks with various carcinogenic processes that play critical roles in tumorigenesis and cancer progression. This review focuses on the biological regulation of the correlative axis among circular RNAs, miRNAs, and their target genes in various cancer types and suggests the biological importance of MDTEs interacting with oncogenic or tumor-suppressive circRNAs in tumor progression.
Assuntos
MicroRNAs , Neoplasias , Humanos , MicroRNAs/genética , MicroRNAs/metabolismo , RNA Circular/genética , Neoplasias/patologia , Carcinogênese/genéticaRESUMO
AIM: The present study aimed to evaluate the accuracy of automated detection of preparation finish lines in teeth with defective margins. MATERIALS AND METHODS: An extracted first molar was prepared for a full veneer crown, and marginal defects were created and scanned (discontinuity of finish line: 0.5, 1.0, and 1.5 mm; additional line angle: connected, partially connected, and disconnected). Six virtual defect models were entered into CAD software and the preparation finish line was designated by 20 clinicians (CAD-experienced group: n = 10; CAD-inexperienced group: n = 10) using the automated finish line detection method. The accuracy of automatic detection was evaluated by calculating the 3D deviation of the registered finish line. The Kruskal-Wallis and Mann-Whitney U tests were used for between-group comparisons (α = 0.05). RESULTS: The deviation values of the registered finish lines were significantly different according to conditions with different amounts of finish line discontinuity (P < 0.001). There was no statistical difference in the deviation of the registered finish line between models with additional line angles around the margin. Moreover, no statistical difference was found in the results between CAD-experienced and CAD-inexperienced operators. CONCLUSIONS: The accuracy of automated finish line detection for tooth preparation can differ when the finish line is discontinuous. The presence of an additional line angle around the preparation margin and prior experience in dental CAD software do not affect the accuracy of automated finish line detection.
Assuntos
Coroas , Preparo Prostodôntico do Dente , Humanos , Preparo Prostodôntico do Dente/métodos , Planejamento de Prótese Dentária , Desenho Assistido por Computador , Adaptação Marginal Dentária , Zircônio , Preparo do DenteRESUMO
Background and Objectives: The purpose of this study is to assess the long-term maintenance of each approach of sinus elevation, the crestal approach and lateral approach, by comparing the radiographic results of each technique. Materials and Methods: In total, 103 patients who had undergone an implant procedure with either the crestal approach or lateral approach method applied to their maxillary molar edentulous area were included. Using orthopantomographs, the radiographic changes were consistently evaluated over 3 years after the procedure (immediately after procedure and 1 year, 2 years and 3 years after implant placement) Results: The radiographic evaluation after 3 years of implantation with sinus elevation showed a significant amount of bone formation (8.07 mm for crestal approach and 12.00 mm for lateral approach method). The largest amount of grafted height loss occurred during the 1 year, but the resorption was minimal (0.98 mm for crestal approach and 0.95 mm for lateral approach method) over the entire 3 years. Conclusions: Although the lateral approach showed more bone growth, the amount of bone resorption was similar to that of the crestal approach. Both methods showed the highest amount of bone resorption in the first year, and the amount of change thereafter was insignificant. It is judged that both methods can be used according to the situation to help implant placement.
Assuntos
Perda do Osso Alveolar , Levantamento do Assoalho do Seio Maxilar , Humanos , Estudos Longitudinais , Levantamento do Assoalho do Seio Maxilar/métodos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Osteogênese , Perda do Osso Alveolar/diagnóstico por imagem , Maxila/diagnóstico por imagem , Maxila/cirurgiaRESUMO
MicroRNAs (miRNAs) are small non-coding RNAs that participate in various biological and cellular processes by regulating target gene expression. miRNAs are also known to play vital roles in the pathogenesis of various diseases, including infections, as well as the disease progression and defense responses. In this study, we examined the expression levels of pol-miR-140-3p and its target gene, kinesin family member 5A (KIF5A), in association with the Streptococcus parauberis (S. parauberis) infection, a major bacterial pathogen that causes streptococcosis in olive flounder (Paralichthys olivaceus). KIF5A is a heavy chain isoform of kinesin-1, which is known to be brain-specific, and this study is the first examination of KIF5A expression related to the regulation of miRNA in olive flounder (named PoKIF5A). There were significant differences in expression levels between infected and healthy olive flounder as the expression of pol-miR-140-3p in the infected fish was lower than that in the control, while the expression of PoKIF5A was higher in the infected fish than in the healthy controls. These contradictory results suggest that downregulated pol-miR-140-3p induces the expression of PoKIF5A against S. parauberis infection in olive flounder.
Assuntos
Doenças dos Peixes , Linguado , MicroRNAs , Infecções Estreptocócicas , Animais , Família , Doenças dos Peixes/microbiologia , Linguado/genética , Linguado/microbiologia , Cinesinas/genética , MicroRNAs/genética , Infecções Estreptocócicas/microbiologia , Infecções Estreptocócicas/veterinária , StreptococcusRESUMO
It is estimated that up to 80% of the human genome is transcribed into RNA molecules but less than 2% of the genome encodes the proteins, and the rest of the RNA transcripts that are not translated into protein are called non-coding RNAs (ncRNAs). Many studies have revealed that ncRNAs have biochemical activities as epigenetic regulators at the post-transcriptional level. Growing evidence has demonstrated that transposable elements (TEs) contribute to a large percentage of ncRNAs' transcription. The TEs inserted into certain parts of the genome can act as alternative promoters, enhancers, and insulators, and the accumulation of TEs increases genetic diversity in the human genome. The TEs can also generate microRNAs, so-called miRNA-derived from transposable elements (MDTEs), and are also implicated in disease progression, such as infectious diseases and cancer. Here, we analyzed the origin of ncRNAs and reviewed the published literature on MDTEs related to disease progression.
Assuntos
Elementos de DNA Transponíveis , MicroRNAs , Elementos de DNA Transponíveis/genética , Progressão da Doença , Genômica , Humanos , MicroRNAs/genética , MicroRNAs/metabolismo , RNA não Traduzido/genéticaRESUMO
Alternative splicing of messenger RNA (mRNA) precursors contributes to genetic diversity by generating structurally and functionally distinct transcripts. In a disease state, alternative splicing promotes incidence and development of several cancer types through regulation of cancer-related biological processes. Transposable elements (TEs), having the genetic ability to jump to other regions of the genome, can bring about alternative splicing events in cancer. TEs can integrate into the genome, mostly in the intronic regions, and induce cancer-specific alternative splicing by adjusting various mechanisms, such as exonization, providing splicing donor/acceptor sites, alternative regulatory sequences or stop codons, and driving exon disruption or epigenetic regulation. Moreover, TEs can produce microRNAs (miRNAs) that control the proportion of transcripts by repressing translation or stimulating the degradation of transcripts at the post-transcriptional level. Notably, TE insertion creates a cancer-friendly environment by controlling the overall process of gene expression before and after transcription in cancer cells. This review emphasizes the correlative interaction between alternative splicing by TE integration and cancer-associated biological processes, suggesting a macroscopic mechanism controlling alternative splicing by TE insertion in cancer.
Assuntos
MicroRNAs , Neoplasias , Processamento Alternativo , Códon de Terminação , Elementos de DNA Transponíveis/genética , Epigênese Genética , Humanos , MicroRNAs/genética , Neoplasias/genéticaRESUMO
STATEMENT OF PROBLEM: Accurate intraoral preparation of screw channels in cement-retained implant prostheses could be a treatment challenge for tilted or badly positioned implants. PURPOSE: The purpose of this randomized clinical trial was to evaluate screw channel accuracy for retrieving cement-retained implant prostheses by using a digitally fabricated drilling guide. MATERIAL AND METHODS: Twenty-four participants requiring removal of cement-retained implant prostheses were recruited and consecutively assigned to 1 of 2 groups. In the first group, drilling guides were fabricated by using an intraoral scan, computer-aided design (CAD), and 3D printing to facilitate screw channel preparation (guide group). In the second group, screw channel preparation was based on panoramic radiographs without a drilling guide (freehand group). Screw channel accuracy was evaluated with a 3D analysis and subsequently compared with the ideal shape of the screw channel for linear deviation at coronal and apical levels, angular deviation, surface loss deviation, and volume loss deviation. The ideal shape of the screw-access channel was based on the Ø2.2-mm cylinder image marked along the long axis of the implant. The Mann-Whitney U and Kruskal-Wallis tests were used for statistical analyses (α=.05). RESULTS: The drilling guide group showed higher dimensional accuracy than the freehand group for angular deviation (9.45 degrees versus 15.69 degrees; P=.014) and surface loss deviation (7.40 mm versus 9.53 mm; P=.001), especially when the implant was tilted more than 30 degrees. The deviation values of the screw channels were not significantly different according to implant tilt in either group (P>.05). CONCLUSIONS: Digitally fabricated drilling guides for intraoral preparation of screw channels in cement-retained implant prostheses can improve accuracy and provide a less-destructive screw channel.
Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Humanos , Cimentos Dentários , Desenho Assistido por Computador , Parafusos Ósseos , Cimentos de Ionômeros de VidroRESUMO
STATEMENT OF PROBLEM: Although several manufacturers market soft metal milling blanks and systems, comprehensive comparative studies of differences in properties across commercially available soft metal milling alloys are lacking. PURPOSE: The purpose of this in vitro study was to compare the microstructures and mechanical properties of 3 soft metal milling cobalt-chromium (Co-Cr) alloys (Ceramill Sintron, Soft Metal, and Sintermetall). MATERIAL AND METHODS: Disk-shaped specimens (for surface characterization and hardness test) and dumbbell-shaped specimens (for tensile test as per International Organization for Standardization (ISO) 22674) were prepared by following each soft metal milling manufacturer's instructions. The crystal structures and microstructures of the 3 alloys were evaluated with optical microscopy, X-ray diffractometry (XRD), and scanning electron microscopy with electron backscattered diffraction (EBSD). The mechanical properties were investigated with a tensile test and Vickers hardness test (n=6). The results of the mechanical (tensile and hardness) tests were analyzed with 1-way ANOVA and the post hoc Tukey multiple comparison test (α=.05). RESULTS: The Sintermetall specimen showed a finer microstructure and more porosity than the other 2 alloys. The XRD and EBSD analyses showed that the γ (face-centered cubic, fcc) matrix phase was predominant in the Ceramill Sintron alloy and the ε (hexagonal close-packed, hcp) matrix phase was predominant in the Soft Metal alloy. The Sintermetall alloy showed a slightly higher amount of ε phase than γ phase, with more chromium carbide formation than the other 2 alloys. The Ceramill Sintron alloy showed a significantly higher tensile strength than the other 2 alloys (P<.05), but a significantly lower 2% offset yield strength than the other 2 alloys (P<.05). The highest elongation was found in the Ceramill Sintron alloy, followed by the Sintermetall and Soft Metal alloys. The elastic modulus was the highest in the Sintermetall alloy, followed by the Soft Metal and Ceramill Sintron alloys. No significant differences in Vickers hardness values were detected among the 3 alloys (P=.263). CONCLUSIONS: The different commercially available soft metal milling blanks and systems produced dissimilar alloys in terms of crystal structures and microstructures and, as a result, different mechanical properties.
Assuntos
Ligas , Ligas de Cromo , Ligas de Cromo/química , Teste de Materiais , Ligas Metalo-Cerâmicas/química , Propriedades de Superfície , Tecnologia , Resistência à TraçãoRESUMO
Non-nociceptive, persistent idiopathic facial pain (PIFP) is a poorly localized, continuous dull pain that occurs even in the absence of apparent pathological lesions or clinical neurologic deficiency. This study aimed to investigate the disease characteristics of PIFP that developed after dental implant treatment. The clinical characteristics of pain as well as treatment method and outcomes were retrospectively analyzed in 20 patients diagnosed with PIFP. The patients developed pain either after implant fixation or prosthetic treatment. In most patients, the pain persisted not only around the implant region but also at a distant site from the related implant (13/20, 65%). Many patients desired removal of the implants to manage the pain although the pain was not considered to be related to the implant treatment. In 12 patients, the related implants were removed, but 67% (n = 8/12) of the patients still experienced chronic pain after implant removal. Medication helped decrease the pain in most patients (n = 17). Pregabalin and clonazepam showed relatively higher efficiency than other medications for controlling the pain. The results showed that although the onset of PIFP was related to dental implant treatment, implant removal could not be considered a reliable option for the management of PIFP. Although medication controls the pain at least partially, complete pain control with medication should not be expected. These results demonstrate that an accurate diagnosis of PIFP is important for the selection of appropriate treatment.
Assuntos
Dor Crônica , Implantes Dentários , Dor Crônica/etiologia , Implantes Dentários/efeitos adversos , Dor Facial/diagnóstico , Dor Facial/tratamento farmacológico , Dor Facial/etiologia , Humanos , Estudos RetrospectivosRESUMO
Progress with additive 3D printing is revolutionizing biomaterial manufacturing, including clinical dentistry and prosthodontics. Among the several 3D additive printing technologies, stereolithography is very popular as it utilizes light-activated resin for precise resolution. A simplified digital technique was used to fabricate two designs of a surgical guide for crown lengthening. Two cases are presented that utilized digital imaging and communications in medicine (DICOM) files obtained with computed tomography (CT) imaging and processed using four CAD software (Blue Sky Plan, Exocad, Meshmixer and 3D Slicer). The final models were converted to standard tessellation (STL) files and the guides were 3D printed with an additive stereolithography (SLA) printer. The first case was fabricated with a bone model from cone beam computed tomography (CBCT) data, and the second case was generated with intraoral and wax-up scans alone. Both methods appear to be equally effective compared to using a conventional method of guide frabication. However, proximal bone reduction was a concern with both designs. Digitally fabricated 3D printed surgical guide for crown lengthening has merit and a practical design is needed for future clinical validation.
Assuntos
Desenho Assistido por Computador , Implantes Dentários , Aumento da Coroa Clínica , Humanos , Impressão Tridimensional , EstereolitografiaRESUMO
OBJECTIVE: This systematic review and meta-analysis aimed to investigate the accuracy of removable partial denture (RPD) frameworks fabricated by computer-aided design/ computer-aided manufacturing (CAD/CAM) systems compared to frameworks produced by conventional casting methods. METHODS: A systematic literature search was conducted in electronic databases following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines, using formulated Boolean operator for searching articles evaluating the fit accuracy of CAD/CAM-fabricated RPD metal frameworks. The agreement of data collection among the reviewers was confirmed using the Cohen kappa coefficient. The modified methodological index for non-randomized studies (MINORS) scale was used to assess the quality of the included studies. Heterogeneity among studies was evaluated, and meta-analyses with global and subgroup analyses were performed. RESULTS: A total of 208 articles were identified with 18 articles available for the narrative review and 7 studies available for meta-analysis on the 3D-printed frameworks for RPD (the overall Cohen kappa coefficientâ¯=â¯0.944). There was no article on the accuracy of RPD frameworks made by milling method. The meta-analysis revealed that the misfit of frameworks obtained with the CAD/CAM method was significantly higher than that of the conventional lost wax and casting method (SMDâ¯=â¯1.23⯵m, 95% CIâ¯=â¯0.3610-2.0981⯵m, zâ¯=â¯2.77, Pâ¯=â¯.0055). Regarding the CAD/CAM techniques used for fabricating RPD metal frameworks, the within subgroup analysis showed that the CAD/CAM-based indirect fabrication method produced frameworks with fit accuracy more similar to the conventional lost-wax and casting method (SMDâ¯=â¯1.15⯵m, 95% CIâ¯=â¯- 0.06136-2.9192⯵m, zâ¯=â¯1.28, P < .01) than the CAD/CAM-based direct fabrication method (SMDâ¯=â¯1.35⯵m, 95% CIâ¯=â¯-0.2722-2.4381⯵m, zâ¯=â¯2.45, P < .01), even though there was no statistical difference between the techniques (Pâ¯=â¯.8482). CONCLUSIONS: The fit accuracy of RPD metal frameworks fabricated by the CAD/CAM method was lower than that of frameworks fabricated by the conventional casting method, but it was within the clinically acceptable range in dimensional misfit. The indirect metal 3D printing technique based on pattern printing and subsequent casting produced frameworks with fit accuracy more similar to the conventional method than the direct fabrication technique.
Assuntos
Prótese Parcial Removível , Desenho Assistido por Computador , Coleta de Dados , Humanos , Impressão TridimensionalRESUMO
BACKGROUND: The accurate assessment and acquisition of facial anatomical information significantly contributes to enhancing the reliability of treatments in dental and medical fields, and has applications in fields such as craniomaxillofacial surgery, orthodontics, prosthodontics, orthopedics, and forensic medicine. Mobile device-compatible 3D facial scanners have been reported to be an effective tool for clinical use, but the accuracy of digital facial impressions obtained with the scanners has not been explored. OBJECTIVE: We aimed to review comparisons of the accuracy of mobile device-compatible face scanners for facial digitization with that of systems for professional 3D facial scanning. METHODS: Individual search strategies were employed in PubMed (MEDLINE), Scopus, Science Direct, and Cochrane Library databases to search for articles published up to May 27, 2020. Peer-reviewed journal articles evaluating the accuracy of 3D facial models generated by mobile device-compatible face scanners were included. Cohen d effect size estimates and confidence intervals of standardized mean difference (SMD) data sets were used for meta-analysis. RESULTS: By automatic database searching, 3942 articles were identified, of which 11 articles were considered eligible for narrative review, with 6 studies included in the meta-analysis. Overall, the accuracy of face models obtained using mobile device-compatible face scanners was significantly lower than that of face models obtained using professional 3D facial scanners (SMD 3.96 mm, 95% CI 2.81-5.10 mm; z=6.78; P<.001). The difference between face scanning when performed on inanimate facial models was significantly higher (SMD 10.53 mm, 95% CI 6.29-14.77 mm) than that when performed on living participants (SMD 2.58 mm, 95% CI 1.70-3.47 mm, P<.001, df=12.94). CONCLUSIONS: Overall, mobile device-compatible face scanners did not perform as well as professional scanning systems in 3D facial acquisition, but the deviations were within the clinically acceptable range of <1.5 mm. Significant differences between results when 3D facial scans were performed on inanimate facial objects and when performed on the faces of living participants were found; thus, caution should be exercised when interpreting results from studies conducted on inanimate objects.