Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 24(1): 318, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080583

RESUMO

PURPOSE: Measurement of corneal endothelial cells is critical for postoperative evaluation of phakic intraocular lens (pIOL) surgery. However, inter-instrument differences in corneal endothelial cell density (ECD) after pIOL implantation have not yet been reported. This study aimed to compare automated corneal endothelial cell analysis between CellChek-20 (Konan Medical, Hyogo, Japan) and EM-4000 (Tomey, Nagoya, Japan) in healthy and postoperative eyes with pIOL. METHODS: We retrospectively analyzed 154 healthy and 236 postoperative eyes after pIOL surgery. Endothelial cell measurements were performed using CellChek-20 and EM-4000 with autofocusing and automated image analysis. ECD, percentage of hexagonal cells (HEX), coefficient of variation in cell size (CoV), and central corneal thickness (CCT) were compared between the two devices. RESULTS: The ECDs of the two devices were highly correlated in both healthy (Spearman's correlation coefficient [r] = 0.805; p < 0.001) and postoperative (r = 0.901; p < 0.001) groups. ECD from CellChek-20 was higher than EM-4000 in both healthy (mean difference = 228.9 cells/mm2; p < 0.001) and postoperative (mean difference = 115.6 cells/mm2; p < 0.001) groups. The CCT values also showed a strong correlation in healthy eyes (r = 0.974; p < 0.001) and in postoperative eyes (r = 0.936; p < 0.001); however, significant inter-instrument differences were observed. HEX and CV showed significant differences and relatively weak correlations (r < 0.7) between the two devices in both healthy and postoperative groups. CONCLUSION: The ECD values between the two instruments were correlated, but that of the CellChek-20 was significantly higher than that of the EM-4000 in both healthy and postoperative eyes after pIOL surgery. Most previous studies have also shown that the Konan software overestimated the ECD compared to other products in automatic measurement mode. The possibility of measurement bias should be considered when replacing equipment used for corneal endothelial cell measurements.


Assuntos
Endotélio Corneano , Lentes Intraoculares Fácicas , Humanos , Endotélio Corneano/patologia , Feminino , Contagem de Células , Masculino , Adulto , Estudos Retrospectivos , Estudos Transversais , Período Pós-Operatório , Adulto Jovem , Implante de Lente Intraocular , Pessoa de Meia-Idade , Miopia/cirurgia
2.
BMC Med Inform Decis Mak ; 24(1): 25, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38273286

RESUMO

BACKGROUND: The epiretinal membrane (ERM) is a common retinal disorder characterized by abnormal fibrocellular tissue at the vitreomacular interface. Most patients with ERM are asymptomatic at early stages. Therefore, screening for ERM will become increasingly important. Despite the high prevalence of ERM, few deep learning studies have investigated ERM detection in the color fundus photography (CFP) domain. In this study, we built a generative model to enhance ERM detection performance in the CFP. METHODS: This deep learning study retrospectively collected 302 ERM and 1,250 healthy CFP data points from a healthcare center. The generative model using StyleGAN2 was trained using single-center data. EfficientNetB0 with StyleGAN2-based augmentation was validated using independent internal single-center data and external datasets. We randomly assigned healthcare center data to the development (80%) and internal validation (20%) datasets. Data from two publicly accessible sources were used as external validation datasets. RESULTS: StyleGAN2 facilitated realistic CFP synthesis with the characteristic cellophane reflex features of the ERM. The proposed method with StyleGAN2-based augmentation outperformed the typical transfer learning without a generative adversarial network. The proposed model achieved an area under the receiver operating characteristic (AUC) curve of 0.926 for internal validation. AUCs of 0.951 and 0.914 were obtained for the two external validation datasets. Compared with the deep learning model without augmentation, StyleGAN2-based augmentation improved the detection performance and contributed to the focus on the location of the ERM. CONCLUSIONS: We proposed an ERM detection model by synthesizing realistic CFP images with the pathological features of ERM through generative deep learning. We believe that our deep learning framework will help achieve a more accurate detection of ERM in a limited data setting.


Assuntos
Aprendizado Profundo , Membrana Epirretiniana , Humanos , Membrana Epirretiniana/diagnóstico por imagem , Estudos Retrospectivos , Técnicas de Diagnóstico Oftalmológico , Fotografação/métodos
3.
Sci Rep ; 14(1): 11989, 2024 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-38796537

RESUMO

VISUMAX 800 was introduced to improve the patient experience and clinical outcomes of small incision lenticule extraction (SMILE). This was a retrospective, matched, and case-control study (1:2) controlled for preoperative central corneal thickness and refractive error that compared early refractive and visual outcomes after SMILE using VISUMAX 800 and VISUMAX 500 to treat myopia. We included 50 eyes that underwent the VISUMAX 800 SMILE and 100 eyes that underwent the VISUMAX 500 SMILE. SMILE using VISUMAX 800 was performed using the CentraLign aid for vertex centration. Cyclotorsion was controlled by an OcuLign assistant in the VISUMAX 800 group after corneal marking. Corneal higher-order aberrations (HOAs) were evaluated using a Pentacam 1 month after surgery. No differences were observed in the pre- and post-operative refractive and visual outcomes at 1 day, 1 month, and 6 months after surgery. VISUMAX 800 induced less total HOAs than VISUMAX 500 (P = 0.036). No statistically significant differences were observed in the amounts of induced spherical aberrations or vertical and horizontal comas. No differences were observed in the 1 month and 6 months refractive and visual outcomes between two SMILE procedures, except for VISUMAX 800, which resulted in lower postoperative total HOAs than VISUMAX 500.


Assuntos
Cirurgia da Córnea a Laser , Miopia , Acuidade Visual , Humanos , Miopia/cirurgia , Feminino , Estudos Retrospectivos , Masculino , Estudos de Casos e Controles , Adulto , Resultado do Tratamento , Cirurgia da Córnea a Laser/métodos , Adulto Jovem , Refração Ocular/fisiologia , Lasers de Excimer/uso terapêutico
4.
Sci Rep ; 14(1): 77, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167592

RESUMO

This study examined the link between fatty liver disease (FLD) and cataracts, as previous research has suggested that FLD may contribute to metabolic syndrome, systemic inflammation, and potentially cataracts. We studied a nationwide cross-sectional cohort of the Fifth Korean National Health and Nutrition Examination Survey 2010-2011. FLD was defined as nonalcoholic FLD (NAFLD) and metabolic dysfunction-associated FLD (MAFLD). Multinomial logistic regression was utilized to investigate the relationship between cataracts and FLD after adjustment for potential confounders. Participants with cataracts had higher liver fibrosis scores, including the NAFLD fibrosis score (NFS; P < 0.001), fibrosis-4 index (FIB4; P < 0.001), and fatty liver index (FLI; P = 0.001). NAFLD was not associated with a higher odds ratio (OR) for cataracts in the fully adjusted model (OR = 1.23, P = 0.058). MAFLD was significantly associated with a higher OR (OR = 1.34, P = 0.006). After adjusting for all factors, the severity of FLD was linked to an increased risk of cataracts, with significant linear trends (P values for linear trends of NFS, FIB4, and FLI < 0.05). After adjusting for well-known cataract risk factors, MAFLD was significantly associated with cataracts. Our analysis suggests that FLD may serve as an independent risk factor for cataracts.


Assuntos
Catarata , Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Estudos Transversais , Inquéritos Nutricionais , Catarata/epidemiologia , Catarata/complicações , República da Coreia/epidemiologia , Fibrose , Cirrose Hepática/complicações
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa