Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Opt Express ; 31(21): 34391-34403, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37859196

RESUMO

Spiral-phase-contrast imaging, which utilizes a spiral phase optical element, has proven to be effective in enhancing various aspects of imaging, such as edge contrast and shadow imaging. Typically, the implementation of spiral-phase-contrast imaging requires the formation of a Fourier plane through a 4f optical configuration in addition to an existing optical microscope. In this study, we present what we believe to be a novel single spiral-phase-objective, integrating a spiral phase plate, which can be easily and simply applied to a standard microscope, such as a conventional objective. Using a new hybrid design approach that combines ray-tracing and field-tracing simulations, we theoretically realized a well-defined and high-quality vortex beam through the spiral-phase-objective. The spiral-phase-objective was designed to have conditions that are practically manufacturable while providing predictable performance. To evaluate its capabilities, we utilized the designed spiral-phase-objective to investigate isotropic spiral phase contrast and anisotropic shadow imaging through field-tracing simulations, and explored the variation of edge contrast caused by changes in the thickness of the imaging object.

2.
Opt Express ; 31(6): 10500-10511, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-37157595

RESUMO

Spectrally encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technique. Here, we present a method to integrate optical coherence tomography (OCT) and SECM for complementary imaging by adding orthogonal scanning to the SECM configuration. The co-registration of SECM and OCT is automatic, as all system components are shared in the same order, eliminating the need for additional optical alignment. The proposed multimode imaging system is compact and cost-effective while providing the benefits of imaging aiming and guidance. Furthermore, speckle noise can be suppressed by averaging the speckles generated by shifting the spectral-encoded field in the direction of dispersion. Using a near infrared (NIR) card and a biological sample, we demonstrated the capability of the proposed system by showing SECM imaging at depths of interest guided by the OCT in real time and speckle noise reduction. Interfaced multimodal imaging of SECM and OCT was implemented at a speed of approximately 7 frames/s using fast-switching technology and GPU processing.

3.
Opt Express ; 30(15): 27273-27284, 2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-36236901

RESUMO

Wavelength-tunable spiral-phase-contrast (SPC) imaging was experimentally accomplished in the visible wavelengths spanning a broad bandwidth of ∼200 nm based on a single off-axis spiral phase mirror (OSPM). By the rotation of an OSPM, which was designed with an integer orbital angular momentum (OAM) of l = 1 at a wavelength of 561 nm and incidence angle of 45°, high-quality SPC imaging was obtained at different wavelengths. For the comparison with wavelength-tunable SPC imaging using an OSPM, SPC imaging using a spiral phase plate (manufactured to generate an OAM of l = 1 at 561 nm) was performed at three wavelengths (473, 561, and 660 nm), resulting in clear differences. Theoretically, based on field tracing simulations, high-quality wavelength-tunable SPC imaging could be demonstrated in a very broad bandwidth of ∼400 nm, which is beyond the bandwidth of ∼200 nm obtained experimentally. This technique contribute to developing high-performance wavelength-tunable SPC imaging by simply integrating an OSPM into the current optical imaging technologies.

4.
Opt Lett ; 46(19): 4887, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34598225

RESUMO

This publisher's note contains corrections to Opt. Lett.46, 4216 (2021)OPLEDP0146-959210.1364/OL.432413.

5.
Opt Lett ; 46(17): 4216-4219, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34469977

RESUMO

Wavelength-tunable optical vortices with a topological charge equal to l=1 of orbital angular momentum (OAM) were experimentally realized using a single off-axis spiral phase mirror (OSPM) with lasers of various visible-light wavelengths. Using an OSPM designed for 561 nm and an incidence angle of 45°, circular doughnut-shaped l=1 optical vortices were obtained at 561, 473, and 660 nm by rotating the OSPM to modify the laser incidence angle. Wavelength-tunable l=1 optical vortices were obtained at the respective incidence angles of 45°, 53.4°, and 33.7°, because the effective geometrical thickness of the OSPM, which determines the order of OAM, was identical at each wavelength. This flexible OSPM which operates over a wide wavelength range will provide continuously wavelength-tunable optical vortices for applications in the fields of advanced optics and photonics in which optical vortices with wide wavelength tunability are in demand.

6.
Opt Lett ; 45(12): 3200-3203, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32538942

RESUMO

We report a new, to the best of our knowledge, approach to correct image blurring due to the axial bulk motion of a sample in wavelength-sweeping Fourier domain parallel optical coherence tomography (OCT). This approach can estimate phase errors changing rapidly in time through direct measurements of the apparent axial shift during the sampling interval using common phase changes in parallel detection without additional hardware. To demonstrate the performance of the proposed algorithm, a single reflection and scattering sample were imaged with wavelength-sweeping parallel OCT implemented by scanning a spectrally dispersed line-field along the line direction. In addition, we quantitatively demonstrated that even a small axial movement of the sample could cause serious image blur at a high nonlinear degree of movement.

7.
Sensors (Basel) ; 20(20)2020 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-33076430

RESUMO

In this study, a portable and large-area blackbody system was developed following a series of processes including design, computational analysis, fabrication, and experimental analysis and evaluation. The blackbody system was designed to be lightweight (5 kg), and its temperature could exceed the ambient temperature by up to 15 °C under operation. A carbon-fiber-based heat source was used to achieve a uniform temperature distribution. A heat shield fabricated from an insulation material was embedded at the opposite side of the heating element to minimize heat loss. A prototype of the blackbody system was fabricated based on the design and transient coupled electro-thermal simulation results. The operation performance of this system, such as the thermal response, signal transfer function, and noise equivalent temperature difference, was evaluated by employing an infrared imaging system. In addition, emissivity was measured during operation. The results of this study show that the developed portable and large-area blackbody system can be expected to serve as a reliable reference source for the calibration of aerial infrared images for the application of aerial infrared techniques to remote sensing.

8.
Opt Express ; 27(15): 21677-21688, 2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31510240

RESUMO

The periodic structure on the optical surface affects the beam shape and its propagation. As the size of the optical elements becomes larger and its shape becomes complicated, the quantitative analysis of the effect of the periodic structure on the optical surface becomes indispensable given that it is very difficult to completely eliminate the microscopic periodic structures. Herein, we have experimentally investigated Bragg scattering from an optical surface with extremely small aspect ratios (~10-5) and groove densities (0.5 lines/mm). We observed the period of the constructive interference formed due to the propagation of the 0th, 1st, and -1st beam modes caused by Bragg scattering. When the periodic structure has a modulation depth of ± 50 nm, the intensity increase of constructive interference between the beam modes formed by Bragg scattering was > 10 times greater than the intensity of a flat surface at the propagation distance at which constructive interference was most pronounced. This study is envisaged to open new avenues for the quantification of the effect of periodic structures based on the observation of the interference on the beam profile formed by Bragg scattering during the beam propagation.

9.
Biochem Biophys Res Commun ; 503(1): 285-290, 2018 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-29890133

RESUMO

Mitochondrial uncoupling protein 1 (UCP1) is responsible for nonshivering thermogenesis in brown adipose tissue (BAT). UCP1 increases the conductance of the inner mitochondrial membrane (IMM) for protons to make BAT mitochondria generate heat rather than ATP. HDAC6 is a cytosolic deacetylase for non-histone substrates to regulate various cellular processes, including mitochondrial quality control and dynamics. Here, we showed that the body temperature of HDAC6 knockout mice is slightly decreased in normal hosing condition. Interestingly, UCP1 was downregulated in BAT of HDAC6 knockout mice, which extensively linked mitochondrial thermogenesis. Mechanistically, we showed that cAMP-PKA signaling plays a key role in HDAC6-dependent UCP1 expression. Notably, the size of brown adipocytes and lipid droplets in HDAC6 knockout BAT is increased. Taken together, our findings suggested that HDAC6 contributes to mitochondrial thermogenesis in BAT by increasing UCP1 expression through cAMP-PKA signaling pathway.


Assuntos
Adipócitos Marrons/metabolismo , Proteínas Quinases Dependentes de AMP Cíclico/metabolismo , Ativação Enzimática , Desacetilase 6 de Histona/metabolismo , Termogênese , Proteína Desacopladora 1/genética , Tecido Adiposo Marrom/fisiologia , Animais , Células Cultivadas , Regulação da Expressão Gênica , Desacetilase 6 de Histona/genética , Metabolismo dos Lipídeos , Masculino , Camundongos , Camundongos Knockout , Mitocôndrias/genética , Mitocôndrias/metabolismo , Transdução de Sinais , Proteína Desacopladora 1/metabolismo
10.
Sensors (Basel) ; 17(12)2017 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-29189725

RESUMO

In this paper, we report on a confocal thermoreflectance imaging system that can examine the thermal characteristics of microelectronic devices by penetrating the backside of a device through the substrate. In this system, the local reflectivity variations due to heat generation in the device are measured point by point by a laser scanning confocal microscope capable of eliminating out-of-focus reflections and the thermoreflectance is extracted via Fourier-domain signal processing. In comparison to the conventional widefield thermoreflectance microscope, the proposed laser scanning confocal thermoreflectance microscope improves the thermoreflectance sensitivity by ~23 times and the spatial resolution by ~25% in backside thermoreflectance measurements.

11.
Sensors (Basel) ; 17(10)2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-29027955

RESUMO

Micro-electronic devices are increasingly incorporating miniature multi-layered integrated architectures. However, the localization of faults in three-dimensional structure remains challenging. This study involved the experimental and numerical estimation of the depth of a thermally active heating source buried in multi-layered silicon wafer architecture by using both phase information from an infrared microscopy and finite element simulation. Infrared images were acquired and real-time processed by a lock-in method. It is well known that the lock-in method can increasingly improve detection performance by enhancing the spatial and thermal resolution of measurements. Operational principle of the lock-in method is discussed, and it is represented that phase shift of the thermal emission from a silicon wafer stacked heat source chip (SSHSC) specimen can provide good metrics for the depth of the heat source buried in SSHSCs. Depth was also estimated by analyzing the transient thermal responses using the coupled electro-thermal simulations. Furthermore, the effects of the volumetric heat source configuration mimicking the 3D through silicon via integration package were investigated. Both the infrared microscopic imaging with the lock-in method and FE simulation were potentially useful for 3D isolation of exothermic faults and their depth estimation for multi-layered structures, especially in packaged semiconductors.

12.
Opt Lett ; 41(18): 4241-4, 2016 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-27628367

RESUMO

We demonstrate a fiber-optic-based parallel optical coherence tomography (OCT) using spectrally encoded extended illumination with a common-path handheld probe, where the flexibility and robustness of the system are significantly improved, which is critical in the clinical environment. To the best of our knowledge, we present the first parallel OCT based on fiber optics including a fiber coupler with a sensitivity of 94 dB, which is comparable to that of point-scanning OCT. We also investigated the effect of the phase stability of the fiber-based interferometry on the parallel OCT system by comparing the common-path OCT with two-arm OCT. Using the homemade common-path handheld probe based on a Mirau interferometer, the phase stability was 32 times better than that of the two-arm OCT. The axial resolution of the common-path OCT was measured as 5.1±0.3 µm. To demonstrate the in vivo imaging performance of the fiber-optic-based parallel OCT, human skin was imaged.

13.
Opt Lett ; 38(10): 1721-3, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23938923

RESUMO

In this Letter, we implement a maximum-likelihood estimator to interpret optical coherence tomography (OCT) data for the first time, based on Fourier-domain OCT and a two-interface tear film model. We use the root mean square error as a figure of merit to quantify the system performance of estimating the tear film thickness. With the methodology of task-based assessment, we study the trade-off between system imaging speed (temporal resolution of the dynamics) and the precision of the estimation. Finally, the estimator is validated with a digital tear-film dynamics phantom.


Assuntos
Imagens de Fantasmas , Lágrimas , Tomografia de Coerência Óptica/instrumentação , Humanos , Funções Verossimilhança
14.
Sci Rep ; 13(1): 3625, 2023 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-36869084

RESUMO

Biochip-based research is currently evolving into a three-dimensional and large-scale basis similar to the in vivo microenvironment. For the long-term live and high-resolution imaging in these specimens, nonlinear microscopy capable of label-free and multiscale imaging is becoming increasingly important. Combination with non-destructive contrast imaging will be useful for effectively locating regions of interest (ROI) in large specimens and consequently minimizing photodamage. In this study, a label-free photothermal optical coherence microscopy (OCM) serves as a new approach to locate the desired ROI within biological samples which are under investigation by multiphoton microscopy (MPM). The weak photothermal perturbation in sample by the MPM laser with reduced power was detected at the endogenous photothermal particles within the ROI using the highly sensitive phase-differentiated photothermal (PD-PT) OCM. By monitoring the temporal change of the photothermal response signal of the PD-PT OCM, the hotspot generated within the sample focused by the MPM laser was located on the ROI. Combined with automated sample movement in the x-y axis, the focal plane of MPM could be effectively navigated to the desired portion of a volumetric sample for high-resolution targeted MPM imaging. We demonstrated the feasibility of the proposed method in second harmonic generation microscopy using two phantom samples and a biological sample, a fixed insect on microscope slide, with dimensions of 4 mm wide, 4 mm long, and 1 mm thick.


Assuntos
Microscopia , Movimento , Imagens de Fantasmas
15.
Appl Opt ; 51(15): 2902-8, 2012 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-22614592

RESUMO

The Gouy phase anomaly, well established for stigmatic beams, is validated here for astigmatic beams. We simulate the predicted Gouy phase anomaly near astigmatic foci using a beam propagation algorithm integrated within lens design software. We then compare computational results with experimental data acquired using a modified Mertz-Sagnac interferometer. Both in simulation and in experiment, results show that a π/2-phase change occurs as the beam passes through each of the astigmatic foci, experimentally validating results derived in a recent paper by Visser and Wolf [Opt. Commun. 283, 3371-3375 (2010)].

16.
Stud Health Technol Inform ; 173: 398-404, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22357025

RESUMO

We report in-vivo volumetric optical coherence microscopy images of the skin, with resolution at the cellular level. With resolution of 2 µm both laterally and axially, structures below the skin as deep as 1 mm may be imaged at various anatomic locations. Custom optical instrumentation was designed, built, and integrated to achieve this unprecedented optical imaging resolution, in three dimensions, at clinically feasible configuration and speed.


Assuntos
Biópsia , Simulação por Computador , Imageamento Tridimensional/métodos , Microscopia , Pele , Humanos , Modelos Anatômicos
17.
Opt Lett ; 36(12): 2221-3, 2011 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-21685973

RESUMO

In this Letter, we report for the first time (to our knowledge) in-vivo volumetric optical coherence microscopy images of skin epidermal cells. We achieved micrometer-class resolution, 2 µm laterally and axially, with an acquisition speed of 23 K A-scans/s and over 90 dB sensitivity to a depth of 1 mm by employing a custom, liquid-lens-based, dynamic-focusing objective, a broadband light source, and a custom, astigmatism-corrected Czerny-Turner spectrometer with a high-speed complementary metal-oxide-semiconductor camera.


Assuntos
Microscopia/métodos , Pele/citologia , Tomografia de Coerência Óptica/métodos , Células Epidérmicas , Humanos , Fatores de Tempo
18.
Appl Opt ; 50(29): 5735-49, 2011 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-22015369

RESUMO

We analyze the three most common profiles of scanning functions for galvanometer-based scanners (GSs): the sawtooth, triangular and sinusoidal functions. They are determined experimentally with regard to the scan parameters of the input signal (i.e., frequency and amplitude). We study the differences of the output function of the GS measured as the positional error of the oscillatory mirror from the ideal function given by the input signal of the device. The limits in achieving the different types of scanning functions in terms of duty cycle and linearity are determined experimentally for the possible range of scan parameters. Of particular importance are the preservation of an imposed duty cycle and profile for the sawtooth function, the quantification of the linearity for the sinusoidal function, and the effective duty cycle for the triangular, as well as for the other functions. The range of scan amplitudes for which the stability of the oscillatory regime of the galvo mirror is stable for different frequencies is also highlighted. While the use of the device in certain scanning regimes is studied, certain rules of thumb are deduced to make the best out of the galvoscanner. Finally, the three types of scanning functions are tested with a Fourier domain optical coherence tomography (FD OCT) setup and the conclusions of the study are demonstrated in an imaging application by correlating the determined limits of the scanning regimes with the requirements of OCT.

19.
Adv Healthc Mater ; 10(18): e2100636, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34235891

RESUMO

Plasmonic photothermal therapy (PPTT) using gold nanoparticles (AuNPs) has shown great potential for use in selective tumor treatment, because the AuNPs can generate destructive heat preferentially upon irradiation. However, PPTT using AuNPs has not been added to practice, owing to insufficient heating methods and tissue temperature measurement techniques, leading to unreliable and inaccurate treatments. Because the photothermal properties of AuNPs vary with laser power, particle optical density, and tissue depth, the accurate prediction of heat generation is indispensable for clinical treatment. In this report, bioprinted 3D complex tissue constructs comprising processed gel obtained from porcine skin and human decellularized adipose tissue are presented for characterization of the photothermal properties of gold nanorods (AuNRs) having an aspect ratio of 3.7 irradiated by a near-infrared laser. Moreover, an analytical function is suggested for achieving PPTT that can cause thermal damage selectively on early-stage human breast cancer by regulating the heat generation of the AuNRs in the tissue.


Assuntos
Neoplasias da Mama , Nanopartículas Metálicas , Nanotubos , Neoplasias da Mama/terapia , Linhagem Celular Tumoral , Feminino , Ouro , Humanos , Nanopartículas Metálicas/uso terapêutico , Fototerapia
20.
Opt Express ; 18(22): 23378-84, 2010 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-21164679

RESUMO

We report an optical design for a low-cost optics, broadband, astigmatism-corrected practical spectrometer. An off-the-shelf cylindrical lens is used to remove astigmatism over the full bandwidth. Results show that better than 0.1 nm spectral resolution and more than 50% throughput were achieved over a bandwidth of 400 nm centered at 800 nm.

SELEÇÃO DE REFERÊNCIAS