Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pediatr Res ; 79(6): 870-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26859363

RESUMO

BACKGROUND: International guidelines suggest that growth of preterm infants should match intrauterine rates. However, the trajectory for extrauterine growth may deviate from the birth percentile due to an irreversible, physiological loss of extracellular fluid during postnatal adaptation to extrauterine conditions. To which "new" physiological growth trajectory preterm infants should adjust to after completed postnatal adaptation is unknown. This study analyzes the postnatal growth trajectories of healthy preterm infants using prospective criteria defining minimal support, as a model for physiological adaptation. METHODS: International, multi-center, longitudinal, observational study at five neonatal intensive care units (NICUs). Daily weights until day of life (DoL) 21 of infants with undisturbed postnatal adaptation were analyzed (gestational ages: (i) 25-29 wk, (ii) 30-34 wk). RESULTS: 981 out of 3,703 admitted infants included. Maximum weight loss was 11% (i) and 7% (ii) by DoL 5, birth weight regained by DoL 15 (i) and 13 (ii). Infants transitioned to growth trajectories parallel to Fenton chart percentiles, 0.8 z-scores below their birth percentiles. The new trajectory after completed postnatal adaptation could be predicted for DoL 21 with R(2) = 0.96. CONCLUSION: This study provides a robust estimate for physiological growth trajectories of infants after undisturbed postnatal adaptation. In the future, the concept of a target postnatal trajectory during NICU care may be useful.


Assuntos
Peso ao Nascer/fisiologia , Idade Gestacional , Recém-Nascido Prematuro/crescimento & desenvolvimento , Biomarcadores/metabolismo , Composição Corporal , Peso Corporal , Feminino , Humanos , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Unidades de Terapia Intensiva Neonatal , Terapia Intensiva Neonatal , Cooperação Internacional , Estudos Longitudinais , Masculino , Estudos Prospectivos , Análise de Regressão
2.
Int J Artif Organs ; 41(7): 393-399, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29562805

RESUMO

INTRODUCTION: A lung assist device, which acts as an artificial placenta, can provide additional gas exchange for preterm and term newborns with respiratory failure. The concept of the lung assist device requires a large bore access via umbilical vessels to allow pumpless extracorporeal blood flow rates up to 30 mL/kg/min. After birth, constricted umbilical vessels need to be reopened for vascular access. The objective is to study the impact of umbilical vessel expansion on vessel integrity for achieving large bore access. METHODS: Umbilical cords from healthy term deliveries were cannulated and dilatated with percutaneous transluminal angioplasty catheters in 1 mm increments from 4 to 8 mm for umbilical artery and from 4 to 15 mm for umbilical vein, n = 6 per expansion diameter. Paraffin-embedded transverse sections of dilated and control samples were HE & Van Gieson stained. Effects of dilatation, shown by splitting, were measured. RESULTS: Umbilical vessel expansion led to concentric splitting, shown by areas devoid of extracellular matrix and nuclei in the tunica intima and media. No radial splitting was observed. Results suggest an expansion threshold of umbilical artery at 6 mm and umbilical vein at 7 mm, while maximal splitting was observed above this threshold (3.6 ± 0.8%, p = 0.043 for umbilical artery 7 mm and 6.3 ± 1.8%, p = 0.048 for umbilical vein 8 mm). Endothelial cell sloughing was present in all dilated samples but not in the control samples. CONCLUSION: The suggested thresholds for safe expansions are similar to in utero umbilical vessel diameters and demonstrate a proof of concept for attaining large bore access for the lung assist device.


Assuntos
Órgãos Artificiais , Pulmão/fisiopatologia , Placenta , Insuficiência Respiratória/terapia , Cordão Umbilical/fisiopatologia , Veias Umbilicais/fisiopatologia , Cateterismo , Dilatação , Feminino , Humanos , Recém-Nascido , Gravidez , Insuficiência Respiratória/fisiopatologia
3.
PLoS One ; 11(8): e0161030, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27508499

RESUMO

AIM: To investigate how two different strategies to form larger neonatal intensive care units (NICU) impact neonatal mortality rates. METHODS: Cross-sectional study modeling admission volumes and mortality rates of 177,086 VLBW infants aggregated into 862 NICUs. Cumulative 3-year data was abstracted from Vermont Oxford Network. The model simulated a reduction in number of NICUs by stepwise exclusion using either admission volume (VOL) or quality (QUAL) cut-offs. After randomly redirecting infants of excluded to remaining NICUs resulting system mortality rates were calculated with and without adjusting for effects of experience levels (EL) using published data to reflect effects of different team-to-patient exposure. RESULTS: The quality-based strategy is more effective in reducing mortality; while VOL alone was not able to reduce system mortality, QUAL already achieved a 5% improvement after reducing 8% of NICUs and redirecting 6% of infants. Including "EL", a 5% improvement of mortality was achieved by reducing 77% (VOL) vs. 7% (QUAL) of NICUs and redirecting 54% (VOL) vs. 5% (QUAL) of VLBW infants, respectively. CONCLUSION: While a critical number of admissions is needed to maintain skills this study emphasizes the importance of including quality parameters to restructure neonatal care. The findings can be generalized to other medical fields.


Assuntos
Mortalidade Infantil , Recém-Nascido Prematuro , Terapia Intensiva Neonatal/estatística & dados numéricos , Indicadores de Qualidade em Assistência à Saúde , Estudos Transversais , Humanos , Lactente , Recém-Nascido , Recém-Nascido de muito Baixo Peso , Mortalidade , Admissão do Paciente/estatística & dados numéricos , Vermont
4.
Clin Nutr ; 34(3): 465-76, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24912866

RESUMO

BACKGROUND & AIMS: Significant biological variation in macronutrient content of breast milk is an important barrier that needs to be overcome to meet nutritional needs of preterm infants. To analyze macronutrient content, commercial infrared milk analyzers have been proposed as efficient and practical tools in terms of efficiency and practicality. Since milk analyzers were originally developed for the dairy industry, they must be validated using a significant number of human milk samples that represent the broad range of variation in macronutrient content in preterm and term milk. Aim of this study was to validate two milk analyzers for breast milk analysis with reference methods and to determine an effective sample pretreatment. Current evidence for the influence of (i) aliquoting, (ii) storage time and (iii) temperature, and (iv) vessel wall adsorption on stability and availability of macronutrients in frozen breast milk is reviewed. METHODS: Breast milk samples (n = 1188) were collected from 63 mothers of preterm and term infants. Milk analyzers: (A) Near-infrared milk analyzer (Unity SpectraStar, USA) and (B) Mid-infrared milk analyzer (Miris, Sweden) were compared to reference methods, e.g. ether extraction, elemental analysis, and UPLC-MS/MS for fat, protein, and lactose, respectively. RESULTS: For fat analysis, (A) measured precisely but not accurately (y = 0.55x + 1.25, r(2) = 0.85), whereas (B) measured precisely and accurately (y = 0.93x + 0.18, r(2) = 0.86). For protein analysis, (A) was precise but not accurate (y = 0.55x + 0.54, r(2) = 0.67) while (B) was both precise and accurate (y = 0.78x + 0.05, r(2) = 0.73). For lactose analysis, both devices (A) and (B) showed two distinct concentration levels and measured therefore neither accurately nor precisely (y = 0.02x + 5.69, r(2) = 0.01 and y = -0.09x + 6.62, r(2) = 0.02 respectively). Macronutrient levels were unchanged in two independent samples of stored breast milk (-20 °C measured with IR; -80 °C measured with wet chemistry) over a period of 14 months. CONCLUSIONS: Milk analyzers in the current configuration have the potential to be introduced in clinical routine to measure fat and protein content, but will need major adjustments.


Assuntos
Gorduras na Dieta/análise , Proteínas Alimentares/análise , Lactose/análise , Leite Humano/química , Cromatografia Líquida de Alta Pressão , Feminino , Congelamento , Humanos , Modelos Lineares , Valor Nutritivo , Reprodutibilidade dos Testes , Espectroscopia de Luz Próxima ao Infravermelho , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa