1.
Brachytherapy ; 23(1): 64-72, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37806788

RESUMO

PURPOSE: An electromagnetic tracking device (EMT) has been integrated in an HDR 3D ultrasound guidance system for prostate HDR. The aim of this study was to compare the efficiency of HDR workflows with and without EM tracking. METHODS AND MATERIALS: A total of 58 patients with a 15 Gy HDR prostate boost were randomized in two arms and two operation room (OR) procedures using: (1) the EMT investigational device, and (2) the Oncentra prostate system (OCP). OR times were compared for both techniques. RESULTS: The overall procedure median time was about 20% shorter for EMT (63 min) compared to OCP (79 min). The US acquisition and contouring was longer for OCP compared to EMT (23 min vs. 16 min). The catheter reconstruction's median times were 23 min and 13 min for OCP and EMT respectively. For the automatic reconstruction with EMT, 62% of cases required no or few manual corrections. Using the EM technology in an OR environment was challenging. In some cases, interferences or the stiffness of the stylet introduced errors in the reconstruction of catheters. The last step was the dosimetry with median times of 11 min (OCP) and 15.5 min (EMT). Finally, it was observed that there was no learning curve associated with the introduction of this new technology. CONCLUSIONS: The EMT device offers an efficient solution for automatic catheter reconstruction for HDR prostate while reducing the possibility of mis-reconstructed catheters caused by issues of visualization in the US images. Because of that, the overall OR times was shorter when using the EMT system.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Catéteres
2.
Brachytherapy ; 20(6): 1296-1304, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34272132

RESUMO

PURPOSE: Ultrasound-based planning for high-dose-rate prostate brachytherapy is commonly used in the clinic, mainly because it offers fast real-time image-guided capability at a relatively low cost. The main difficulty with US planning is the catheter reconstruction due to artefacts (from multiple catheters) and echogenicity. Electromagnetic tracking (EMT) system offers a fast and accurate solution for automatic reconstruction of catheters using the EMT technology. In this study, the commissioning and performance evaluation of the new real-time prostate high-dose-rate brachytherapy investigational system from Philips Disease Management Solutions integrating EMT was performed before its clinical integration. METHOD AND MATERIALS: The Philips' clinical investigational system includes a treatment planning software (TPS) that was commissioned based on AAPM TG53 and TG56 recommendations for the use of TPS in brachytherapy. First, the CIRS - model 045A - QA phantom was used to evaluate the ultrasound (US) image quality and 3D image handling. Distances, volumes, and dimensions of the structures inside the phantom were measured and compared to the actual values. The calibration reproducibility and accuracy of the electromagnetic (EM) sensor used to track the US probe (rotation and translation) were performed using a specifically designed QA tool mounted on the probe and immersed in a salted water tank. This was performed for 3 different B&K 8848 US probes to evaluate the sensitivity of EM calibration to the probe geometric properties (manufacturing process). The new TPS performance was compared to that in OncentraBrachy (OcB) V4.5.5 (Elekta) using 30 clinical cases as part of a retrospective study. Following the system commissioning, clinical workflows were explored; tests were performed with the brachytherapy team on phantoms and finally implemented in the clinic. RESULTS: US image quality evaluation showed a mean difference with actual dimensions (lengths, widths and distances) of 0.4 mm (±0.3 mm) and mean difference in volume sizes of 0.2 cc (±0.2 cc). Then, the calibration of the US-to-EM coordinate system was performed for 3 different probes. For each probe, 3 measurements were acquired for every position of the calibration tool and measurements were repeated 3 times for a total of 27 measurements per probe per plane. The error was slightly higher in transverse mode compared to sagittal mode with mean values of 0.6 ± 0.2 mm and 0.3 ± 0.1 mm respectively. 30 clinical cases were used to compare the new TPS performance to OcB (IPSA). Optimized plans obtained with both systems were all clinically acceptable, but the plans from the Philips system have slightly higher V150% values, V200% values and dose to organs at risk. In the case of organs at risk, plans could have been manually modified to reduce the dose. Philips' system had a larger number of active dwell positions and longer treatment times. CONCLUSIONS: The first clinical version of Philips' system was proven to be stable, accurate and precise. The fully integrated EM tracking technology opens the way for automated catheter reconstruction and on-the-fly dynamical replanning.


Assuntos
Braquiterapia , Próstata , Braquiterapia/métodos , Fenômenos Eletromagnéticos , Humanos , Masculino , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tecnologia , Ultrassonografia