Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(3): 773-785, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37723254

RESUMO

The National Institute of Standards and Technology (NIST) has prepared four seafood reference materials (RMs) for use in food safety and nutrition studies: wild-caught and aquacultured salmon (RM 8256 and RM 8257) and wild-caught and aquacultured shrimp (RM 8258 and RM 8259). These materials were characterized using genetic, metabolomic (1H-NMR, nuclear magnetic resonance and LC-HRMS/MS, liquid chromatography high-resolution tandem mass spectrometry), lipidomic, and proteomic methods to explore their use as matrix-matched, multi-omic differential materials for method development towards identifying product source and/or as quality control in untargeted omics studies. The results from experimental replicates were reproducible for each reference material and analytical method, with the most abundant features reported. Additionally, differences between the materials could be detected, where wild-caught and aquacultured seafood could be distinguished using untargeted metabolite, lipid, and protein analyses. Further processing of the fresh-frozen RMs by freeze-drying revealed the freeze-dried seafoods could still be reliably discerned. These results demonstrate the usefulness of these reference materials as tools for omics instrument validation and measurement harmonization in seafood-related studies. Furthermore, their use as differential quality control (QC) materials, regardless of preparation method, may also provide a tool for laboratories to demonstrate proficiency at discriminating between products based on source/species.


Assuntos
Multiômica , Proteômica , Padrões de Referência , Controle de Qualidade , Alimentos Marinhos/análise
2.
Molecules ; 25(6)2020 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-32214034

RESUMO

Explosives detection systems (EDS) based on X-ray are used at airports to screen baggage for the presence of explosives. Once EDS are installed in airports, however, it can be challenging to test the EDS equipment and verify that it continues to perform at the highest level, because of the impracticality of introducing bulk explosives into civil aviation airports. The problem is particularly acute for sensitive homemade explosives, such as triacetone triperoxide (TATP). This paper describes our work to develop a safe, accurate and stable simulant for TATP for EDS based on X-ray transmission. Bulk quantities of TATP were synthesised and characterised especially for this project, and we describe the unique challenges and safety considerations of collecting this data. Our calculations show that the expanded measurement uncertainty with a coverage factor of k = 2 is 5.7% for bulk density and 1.0% for Zeff at 24 months.


Assuntos
Compostos Heterocíclicos com 1 Anel/química , Peróxidos/química , Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa