Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Magn Reson Imaging ; 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38449389

RESUMO

BACKGROUND: Different MR elastography (MRE) systems may produce different stiffness measurements, making direct comparison difficult in multi-center investigations. PURPOSE: To assess the repeatability and reproducibility of liver stiffness measured by three typical MRE systems. STUDY TYPE: Prospective. POPULATION/PHANTOMS: Thirty volunteers without liver disease history (20 males, aged 21-28)/5 gel phantoms. FIELD STRENGTH/SEQUENCE: 3.0 T United Imaging Healthcare (UIH), 1.5 T Siemens Healthcare, 3.0 T General Electric Healthcare (GE)/Echo planar imaging-based MRE sequence. ASSESSMENT: Wave images of volunteers and phantoms were acquired by three MRE systems. Tissue stiffness was evaluated by two observers, while phantom stiffness was assessed automatically by code. The reproducibility across three MRE systems was quantified based on the mean stiffness of each volunteer and phantom. STATISTICAL TESTS: Intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman analyses were used to assess the interobserver reproducibility, the interscan repeatability, and the intersystem reproducibility. Paired t-tests were performed to assess the interobserver and interscan variation. Friedman tests with Dunn's multiple comparison correction were performed to assess the intersystem variation. P values less than 0.05 indicated significant difference. RESULTS: The reproducibility of stiffness measured by the two observers demonstrated consistency with ICC > 0.92, CV < 4.32%, Mean bias < 2.23%, and P > 0.06. The repeatability of measurements obtained using the electromagnetic system for the liver revealed ICC > 0.96, CV < 3.86%, Mean bias < 0.19%, P > 0.90. When considering the range of reproducibility across the three systems for liver evaluations, results ranged with ICCs from 0.70 to 0.87, CVs from 6.46% to 10.99%, and Mean biases between 1.89% and 6.30%. Phantom studies showed similar results. The values of measured stiffness differed across all three systems significantly. DATA CONCLUSION: Liver stiffness values measured from different MRE systems can be different, but the measurements across the three MRE systems produced consistent results with excellent reproducibility. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

2.
J Magn Reson Imaging ; 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38344910

RESUMO

BACKGROUND: Pretreatment identification of microvascular invasion (MVI) in hepatocellular carcinoma (HCC) is important when selecting treatment strategies. PURPOSE: To improve models for predicting MVI and recurrence-free survival (RFS) by developing nomograms containing three-dimensional (3D) MR elastography (MRE). STUDY TYPE: Prospective. POPULATION: 188 patients with HCC, divided into a training cohort (n = 150) and a validation cohort (n = 38). In the training cohort, 106/150 patients completed a 2-year follow-up. FIELD STRENGTH/SEQUENCE: 1.5T 3D multifrequency MRE with a single-shot spin-echo echo planar imaging sequence, and 3.0T multiparametric MRI (mp-MRI), consisting of diffusion-weighted echo planar imaging, T2-weighted fast spin echo, in-phase out-of-phase T1-weighted fast spoiled gradient-recalled dual-echo and dynamic contrast-enhanced gradient echo sequences. ASSESSMENT: Multivariable analysis was used to identify the independent predictors for MVI and RFS. Nomograms were constructed for visualization. Models for predicting MVI and RFS were built using mp-MRI parameters and a combination of mp-MRI and 3D MRE predictors. STATISTICAL TESTS: Student's t-test, Mann-Whitney U test, chi-squared or Fisher's exact tests, multivariable analysis, area under the receiver operating characteristic curve (AUC), DeLong test, Kaplan-Meier analysis and log rank tests. P < 0.05 was considered significant. RESULTS: Tumor c and liver c were independent predictors of MVI and RFS, respectively. Adding tumor c significantly improved the diagnostic performance of mp-MRI (AUC increased from 0.70 to 0.87) for MVI detection. Of the 106 patients in the training cohort who completed the 2-year follow up, 34 experienced recurrence. RFS was shorter for patients with MVI-positive histology than MVI-negative histology (27.1 months vs. >40 months). The MVI predicted by the 3D MRE model yielded similar results (26.9 months vs. >40 months). The MVI and RFS nomograms of the histologic-MVI and model-predicted MVI-positive showed good predictive performance. DATA CONCLUSION: Biomechanical properties of 3D MRE were biomarkers for MVI and RFS. MVI and RFS nomograms were established. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

3.
NMR Biomed ; 34(12): e4592, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34291510

RESUMO

Our goal is to design, test and verify an electromagnetic actuator for brain magnetic resonance elastography (MRE). We proposed a grappler-shaped design that can transmit stable vibrations into the brain. To validate its performance, simulations were carried out to ensure the electromagnetic field generated by the actuator did not interfere with the B0 field. The actuation vibration spectrum was analyzed to verify the actuation accuracy. Phantom and volunteer experiments were carried out to evaluate the performance of the actuator. Simulation of the magnetic field showed that the proposed actuator has a fringe field of less than 3 G in the imaging region. The phantom experiments showed that the proposed actuator did not interfere with the routine imaging sequences. The measured vibration spectra demonstrated that the frequency offset was about one third that of a pneumatic device and the transmission efficiency was three times higher. The shear moduli estimated from brain MRE were consistent with those from the literature. The actuation frequency of the proposed actuator has less frequency offset and off-center frequency components compared with the pneumatic counterpart. The whole actuator weighted only 980 g. The actuator can carry out multifrequency MRE on the brain with high accuracy. It is easy to use, comfortable for the patient and portable.


Assuntos
Encéfalo/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Fenômenos Eletromagnéticos , Humanos , Imageamento por Ressonância Magnética/métodos
4.
Eur Radiol ; 31(3): 1748-1759, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32897416

RESUMO

OBJECTIVES: To assess whole-liver texture analysis on T1 maps for risk stratification of advanced fibrosis in patients with suspected nonalcoholic fatty liver disease (NAFLD). METHODS: This retrospective study included 53 patients. Histogram and texture parameters (volume, mean, SD, median, 5th percentile, 95th percentile, skewness, kurtosis, diff-entropy, diff-variance, contrast, and entropy) of T1 maps were calculated based on the semi-automatically segmented whole-liver volume. A two-step approach combining the Nonalcoholic Fatty Liver Disease Fibrosis Score (NFS) and Fibrosis-4 Index (FIB-4) with the liver stiffness measurement (LSM) for the risk stratification was used. Univariate analysis was performed to identify significant parameters. Logistic regression models were then run on the significant features. Diagnostic performance was evaluated with receiver operating characteristic (ROC) analysis. RESULTS: In total, 33 (62%) subjects had a low risk and 20 (38%) subjects had an intermediate-to-high risk of advanced fibrosis. The following significantly different parameters with the best performance were diff-entropy, entropy, and diff-variance, with AUROC 0.837 (95% CI 0.73-0.95), 0.821 (95% CI 0.71-0.94), and 0.807 (95% CI 0.69-0.93). The optimal combination of median, 5th percentile, and diff-entropy as a multivariate model improved the diagnostic performance to diagnose an intermediate-to-high risk of advanced fibrosis with AUROC 0.902(95% CI 0.79-0.97). CONCLUSIONS: Parameters obtained by histogram and texture analysis of T1 maps may be a noninvasive analytical approach for stratifying the risk of advanced fibrosis in NAFLD. KEY POINTS: • Variable flip angle (VFA) T1 mapping can be used to acquire 3D T1 maps within a clinically acceptable duration. • Whole-liver histogram and texture parameters on T1 maps in patients with NAFLD can distinguish those with an intermediate-to-high risk of advanced fibrosis. • The multivariate model of combination of texture parameters improved the diagnostic performance for a high risk of advanced fibrosis and clinical parameters offer no added value to the multivariate model.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Retrospectivos , Medição de Risco
5.
J Magn Reson Imaging ; 48(2): 301-317, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29897645

RESUMO

Iron has long been implicated in many neurological and other organ diseases. It is known that over and above the normal increases in iron with age, in certain diseases there is an excessive iron accumulation in the brain and liver. MRI is a noninvasive means by which to image the various structures in the brain in three dimensions and quantify iron over the volume of the object of interest. The quantification of iron can provide information about the severity of iron-related diseases as well as quantify changes in iron for patient follow-up and treatment monitoring. This article provides an overview of current MRI-based methods for iron quantification, specifically for the brain and liver, including: signal intensity ratio, R2 , R2*, R2', phase, susceptibility weighted imaging and quantitative susceptibility mapping (QSM). Although there are numerous approaches to measuring iron, R2 and R2* are currently preferred methods in imaging the liver and QSM has become the preferred approach for imaging iron in the brain. LEVEL OF EVIDENCE: 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018. J. MAGN. RESON. IMAGING 2018;48:301-317.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Sobrecarga de Ferro/diagnóstico por imagem , Ferro/química , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Animais , Mapeamento Encefálico/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Camundongos , Doenças Neurodegenerativas/metabolismo
6.
J Comput Assist Tomogr ; 41(1): 18-24, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27893493

RESUMO

OBJECTIVE: The aim of this study was to investigate the value of susceptibility-weighted imaging (SWI) for detection and quantification of iron deposition in cirrhotic liver. METHODS: Fifty-five cirrhotic patients underwent hepatic magnetic resonance imaging examination including SWI and multiecho T2*-weighted imaging (T2*WI). Detection of iron deposition and number of siderotic nodules were compared between SWI and T2*WI. Correlation among SWI phase value, T2* value, and hepatic iron concentration were determined. RESULTS: Susceptibility-weighted imaging significantly improved detection of iron deposition compared with T2*WI (90.7% vs 66.7%, P = 0.002), attributing to grade 1 (73.3% vs 26.7%, P = 0.027) and grade 2 (93.8% vs 56.3%, P = 0.037). Iron deposition of grade 3 and 4 could be detected by both SWI and T2*WI. The number of siderotic nodules visualized on SWI was significantly larger than that on T2*WI (107.5 ± 7.4 vs 62.7 ± 4.6, P = 0.002). There were significantly negative correlation between phase value and iron score (r = -0.803), and positive correlation between phase value and T2* value (r = 0.771). CONCLUSIONS: Susceptibility-weighted imaging can improve detection of minimal and mild iron deposition in cirrhotic liver.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Ferro/metabolismo , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/metabolismo , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
7.
Insights Imaging ; 15(1): 91, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38530543

RESUMO

OBJECTIVES: The capability of MR elastography (MRE) to differentiate fibrosis and inflammation, and to provide precise diagnoses is crucial, whereas the coexistence of fibrosis and inflammation may obscure the diagnostic accuracy. METHODS: In this retrospective study, from June 2020 to December 2022, chronic viral hepatitis patients who underwent multifrequency MRE (mMRE) were included in, and further divided into, training and validation cohorts. The hepatic viscoelastic parameters [shear wave speed (c) and loss angle (φ) of the complex shear modulus] were obtained from mMRE. The logistic regression and receiver operating characteristic (ROC) curves were generated to evaluate performance of viscoelastic parameters for fibrosis and inflammation. RESULTS: A total of 233 patients were assigned to training cohort and validation cohorts (mean age, 52 years ± 13 (SD); 51 women; training cohort, n = 170 (73%), and validation cohort, n = 63 (27%)). Liver c exhibited superior performance in detecting fibrosis with ROC (95% confidence interval) of ≥ S1 (0.96 (0.92-0.99)), ≥ S2 (0.86 (0.78-0.92)), ≥ S3 (0.89 (0.84-0.95)), and S4 (0.88 (0.83-0.93)). Similarly, φ was effective in diagnosing inflammation with ROC values of ≥ G2 (0.72 (0.63-0.81)), ≥ G3 (0.88 (0.83-0.94)), and G4 (0.92 (0.87-0.98)). And great predictive discrimination for fibrosis and inflammation were shown in validation cohort (all AUCs > 0.75). CONCLUSION: The viscoelastic parameters derived from multifrequency MRE could realize simultaneous detection of hepatic fibrosis and inflammation. CRITICAL RELEVANCE STATEMENT: Fibrosis and inflammation coexist in chronic liver disease which obscures the diagnostic performance of MR elastography, whereas the viscoelastic parameters derived from multifrequency MR elastography could realize simultaneous detection of hepatic fibrosis and inflammation. KEY POINTS: • Hepatic biomechanical parameters derived from multifrequency MR elastography could effectively detect fibrosis and inflammation. • Liver stiffness is useful for detecting fibrosis independent of inflammatory activity. • Fibrosis could affect the diagnostic efficacy of liver viscosity in inflammation, especially in early-grade of inflammation.

8.
IEEE Trans Biomed Eng ; PP2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38530718

RESUMO

Magnetic resonance elastography (MRE) of brain relies on inducing and measuring shear waves in the brain. However, studies have shown vibration could induce changes in cerebral blood flow (CBF), which has a modulation effect and can affect the biomechanical properties measured. OBJECTIVE: This work demonstrates the initial prototype of the indirect excitation method, which can generate shear waves in the brain with minimal changes in CBF. METHODS: A simple system was designed to produce stable vibrations underneath the neck. Instead of directly stimulating the skull, shear waves were indirectly transmitted to the brain through the spine and brainstem. RESULTS: Phantom results showed that the proposed actuator did not interfere with the routine imaging sequence and successfully generated multifrequency shear waves. When compared with the conventional direct head stimulation method, brain MRE results from the proposed actuator showed no significant differences in terms of intraclass correlation coefficients (ICC) and coefficients of variation (CV). Moreover, the octahedral shear strain (OSS) generated by the indirect excitation in the frontal and parietal lobes decreased by 25.96% and 16.73% respectively. Evaluation of CBF in healthy volunteers revealed no significant changes for the indirect excitation method, whereas significant decreases in CBF were observed in four subregions when employing direct excitation. CONCLUSION: The proposed actuator offers a more accurate and comfortable approach to MRE measurements while causing minimal CBF alterations. SIGNIFICANCE: This work presents the first demonstration of an indirect excitation brain MRE system that minimizes CBF changes, thus holding potential for future applications of brain MRE.

9.
Abdom Imaging ; 38(6): 1269-76, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23942951

RESUMO

PURPOSE: To investigate MR imaging findings of primary hepatic neuroendocrine carcinoma (PHNEC) including preliminary observations on diffusion-weighted imaging (DWI). MATERIALS AND METHODS: MR images of eight patients with pathologically confirmed PHNEC were retrospectively analyzed. The morphological characteristics and dynamic enhancement patterns were evaluated. RESULTS: One case showed a well-defined solitary nodule with homogenous hypointensity on T1-weighted imaging (T1WI) and hyperintensity on T2-weighted imaging (T2WI) and DWI. The remaining seven cases appeared as well-defined dominant masses with multiple satellite nodules. The dominant masses demonstrated heterogeneous hypointensity on T1WI and hyperintensity on T2WI, which all appeared as a marked enhancement at arterial phase and rapid washout at portal venous phase. Six cases demonstrated rim-like enhancement at equilibrium phase. The satellite lesions showed heterogeneous hypointensity on T1WI and marked hyperintensity on T2WI with variable enhancements, such as homogeneous, rim-like enhancement. All the dominant masses and satellite nodules appeared as markedly hyperintensity and reduced apparent coefficient (ADCs) values on DWI. The mean ADC value of the tumors was significantly lower than that of surrounding liver parenchyma (1.02 ± 0.57 vs. 2.24 × 10(-3) mm(2)/s, p = 0.000). CONCLUSION: PHNECs typically appear as a large dominant hypervascular mass accompanied by satellite nodules, with rapid washout and capsular enhancement on dynamic MR imaging and restricted diffusion on DWI.


Assuntos
Carcinoma Neuroendócrino/patologia , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Idoso , Carcinoma Neuroendócrino/cirurgia , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Feminino , Hepatectomia , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
Front Oncol ; 13: 1095637, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845688

RESUMO

Introduction: Diffusion-weighted imaging (DWI) with parallel reconstruction may suffer from a mismatch between the coil calibration scan and imaging scan due to motions, especially for abdominal imaging. Methods: This study aimed to construct an iterative multichannel generative adversarial network (iMCGAN)-based framework for simultaneous sensitivity map estimation and calibration-free image reconstruction. The study included 106 healthy volunteers and 10 patients with tumors. Results: The performance of iMCGAN was evaluated in healthy participants and patients and compared with the SAKE, ALOHA-net, and DeepcomplexMRI reconstructions. The peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), root mean squared error (RMSE), and histograms of apparent diffusion coefficient (ADC) maps were calculated for assessing image qualities. The proposed iMCGAN outperformed the other methods in terms of the PSNR (iMCGAN: 41.82 ± 2.14; SAKE: 17.38 ± 1.78; ALOHA-net: 20.43 ± 2.11 and DeepcomplexMRI: 39.78 ± 2.78) for b = 800 DWI with an acceleration factor of 4. Besides, the ghosting artifacts in the SENSE due to the mismatch between the DW image and the sensitivity maps were avoided using the iMCGAN model. Discussion: The current model iteratively refined the sensitivity maps and the reconstructed images without additional acquisitions. Thus, the quality of the reconstructed image was improved, and the aliasing artifact was alleviated when motions occurred during the imaging procedure.

11.
Insights Imaging ; 14(1): 89, 2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37198348

RESUMO

BACKGROUND: To investigate the viscoelastic signatures of proliferative hepatocellular carcinoma (HCC) using three-dimensional (3D) magnetic resonance elastography (MRE). METHODS: This prospective study included 121 patients with 124 HCCs as training cohort, and validation cohort included 33 HCCs. They all underwent preoperative conventional magnetic resonance imaging (MRI) and tomoelastography based on 3D multifrequency MRE. Viscoelastic parameters of the tumor and liver were quantified as shear wave speed (c, m/s) and loss angle (φ, rad), representing stiffness and fluidity, respectively. Five MRI features were evaluated. Multivariate logistic regression analyses were used to determine predictors of proliferative HCC to construct corresponding nomograms. RESULTS: In training cohort, model 1 (Combining cirrhosis, hepatitis virus, rim APHE, peritumoral enhancement, and tumor margin) yielded an area under the curve (AUC), sensitivity, specificity, accuracy of 0.72, 58.73%,78.69%, 67.74%, respectively. When adding MRE properties (tumor c and tumor φ), established model 2, the AUC increased to 0.81 (95% CI 0.72-0.87), with sensitivity, specificity, accuracy of 71.43%, 81.97%, 75%, respectively. The C-index of nomogram of model 2 was 0.81, showing good performance for proliferative HCC. Therefore, integrating tumor c and tumor φ can significantly improve the performance of preoperative diagnosis of proliferative HCC (AUC increased from 0.72 to 0.81, p = 0.012). The same finding was observed in the validation cohort, with AUC increasing from 0.62 to 0.77 (p = 0.021). CONCLUSIONS: Proliferative HCC exhibits low stiffness and high fluidity. Adding MRE properties (tumor c and tumor φ) can improve performance of conventional MRI for preoperative diagnosis of proliferative HCC. CRITICAL RELEVANCE STATEMENT: We investigated the viscoelastic signatures of proliferative hepatocellular carcinoma (HCC) using three-dimensional (3D) magnetic resonance elastography (MRE), and find that adding MRE properties (tumor c and tumor φ) can improve performance of conventional MRI for preoperative diagnosis of proliferative HCC.

12.
IEEE Trans Med Imaging ; 42(9): 2631-2642, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37030683

RESUMO

Magnetic Resonance Elastography (MRE) can characterize biomechanical properties of soft tissue for disease diagnosis and treatment planning. However, complicated wavefields acquired from MRE coupled with noise pose challenges for accurate displacement extraction and modulus estimation. Using optimization-based displacement extraction and Traveling Wave Expansion-based Neural Network (TWENN) modulus estimation, we propose a new pipeline for processing MRE images. An objective function with Dual Data Consistency (Dual-DC) has been used to ensure accurate phase unwrapping and displacement extraction. For the estimation of complex wavenumbers, a complex-valued neural network with displacement covariance as an input has been developed. A model of traveling wave expansion is used to generate training datasets for the network with varying levels of noise. The complex shear modulus map is obtained through fusion of multifrequency and multidirectional data. Validation using brain and liver simulation images demonstrates the practical value of the proposed pipeline, which can estimate the biomechanical properties with minimal root-mean-square errors when compared to state-of-the-art methods. Applications of the proposed method for processing MRE images of phantom, brain, and liver reveal clear anatomical features, robustness to noise, and good generalizability of the pipeline.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
13.
Eur J Radiol ; 168: 111149, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37862927

RESUMO

PURPOSE: Diffusion-weighted imaging (DWI) of the liver suffers from low resolution, noise, and artifacts. This study aimed to investigate the effect of deep learning reconstruction (DLR) on image quality and apparent diffusion coefficient (ADC) quantification of liver DWI at 3 Tesla. METHOD: In this prospective study, images of the liver obtained at DWI with b-values of 0 (DWI0), 50 (DWI50) and 800 s/mm2 (DWI800) from consecutive patients with liver lesions from February 2022 to February 2023 were reconstructed with and without DLR (non-DLR). Image quality was assessed qualitatively using Likert scoring system and quantitatively using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and liver/parenchyma boundary sharpness from region-of-interest (ROI) analysis. ADC value of lesion were measured. Phantom experiment was also performed to investigate the factors that determine the effect of DLR on ADC value. Qualitative score, SNR, CNR, boundary sharpness, and apparent diffusion coefficients (ADCs) for DWI were compared using paired t-test and Wilcoxon signed rank test. P < 0.05 was considered statistically significant. RESULTS: A total of 85 patients with 170 lesions were included. DLR group showed a higher qualitative score than the non-DLR group. for example, with DWI800 the score was 4.77 ± 0.52 versus 4.30 ± 0.63 (P < 0.001). DLR group also showed higher SNRs, CNRs and boundary sharpness than the non-DLR group. DLR reduced the ADC of malignant tumors (1.105[0.904, 1.340] versus 1.114[0.904, 1.320]) (P < 0.001), but there was no significant difference in the diagnostic value of malignancy for DLR and non-DLR groups (P = 57.3). The phantom study confirmed a reduction of ADC in images with low resolution, and a stronger reduction of ADC in heterogeneous structures than in homogeneous ones (P < 0.001). CONCLUSIONS: DLR improved image quality of liver DWI. DLR reduced the ADC value of lesions, but did not affect the diagnostic performance of ADC in distinguishing malignant tumors on a 3.0-T MRI system.


Assuntos
Aprendizado Profundo , Neoplasias , Humanos , Estudos Prospectivos , Estudos de Viabilidade , Fígado/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos
14.
Hepatol Int ; 17(6): 1626-1636, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37188998

RESUMO

BACKGROUND AND AIMS: Some drug-induced liver injury (DILI) cases may become chronic, even after drug withdrawal. Radiomics can predict liver disease progression. We established and validated a predictive model incorporating the clinical characteristics and radiomics features for predicting chronic DILI. METHODS: One hundred sixty-eight DILI patients who underwent liver gadolinium-diethylenetriamine pentaacetate-enhanced magnetic resonance imaging were recruited. The patients were clinically diagnosed using the Roussel Uclaf causality assessment method. Patients who progressed to chronicity or recovery were randomly divided into the training (70%) and validation (30%) cohorts, respectively. Hepatic T1-weighted images were segmented to extract 1672 radiomics features. Least absolute shrinkage and selection operator regression was used for feature selection, and Rad-score was constructed using support vector machines. Multivariable logistic regression analysis was performed to build a clinic-radiomics model incorporating clinical characteristics and Rad-scores. The clinic-radiomics model was evaluated for its discrimination, calibration, and clinical usefulness in the independent validation set. RESULTS: Of 1672 radiomics features, 28 were selected to develop the Rad-score. Cholestatic/mixed patterns and Rad-score were independent risk factors of chronic DILI. The clinic-radiomics model, including the Rad-score and injury patterns, distinguished chronic from recovered DILI patients in the training (area under the receiver operating characteristic curve [AUROC]: 0.89, 95% confidence interval [95% CI]: 0.87-0.92) and validation (AUROC: 0.88, 95% CI: 0.83-0.91) cohorts with good calibration and great clinical utility. CONCLUSION: The clinic-radiomics model yielded sufficient accuracy for predicting chronic DILI, providing a practical and non-invasive tool for managing DILI patients.


Assuntos
Doença Hepática Induzida por Substâncias e Drogas , Colestase , Humanos , Área Sob a Curva , Doença Hepática Induzida por Substâncias e Drogas/diagnóstico por imagem , Doença Hepática Induzida por Substâncias e Drogas/etiologia , Imageamento por Ressonância Magnética , Estudos Retrospectivos
15.
J Magn Reson Imaging ; 36(4): 900-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22744981

RESUMO

PURPOSE: To assess the value of 2D multibreath-hold susceptibility-weighted imaging (SWI) for visualizing intratumoral hemorrhage of hepatocellular carcinoma (HCC) and correlate with pathological results. MATERIALS AND METHODS: Fifty-eight patients with 65 HCCs underwent T1-, T2-, T2-weighted imaging and SWI. The ability to detect intratumoral hemorrhage for each imaging technique was evaluated. A radiologic-pathological correlation was performed. RESULTS: The area under the receiver operator characteristic (ROC) curve (Az value) for SWI (Az = 0.941) was significantly greater than that for T1WI (Az = 0.748) and T2WI (Az = 0.700) (P = 0.000). When compared with T2, SWI had slightly higher sensitivity and equal specificity, but the Az value was not significantly different (P = 0.768). The total number of hemorrhages detected by SWI was greatest by factors of 13.3, 6.7, and 2.2 compared to T1WI, T2WI, and T2, respectively. SWI detected more microbleeds (585 in 25 HCCs) than T1WI (13 in 5 HCCs), T2WI (66 in 11 HCCs), and T2 (238 in 21 HCCs). CONCLUSION: SWI can accurately visualize internal hemorrhages and provide valuable information regarding the internal architecture of HCC.


Assuntos
Suspensão da Respiração , Carcinoma Hepatocelular/patologia , Hemorragia/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Carcinoma Hepatocelular/complicações , Feminino , Hemorragia/etiologia , Humanos , Aumento da Imagem/métodos , Neoplasias Hepáticas/complicações , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
16.
Ann Transl Med ; 10(6): 343, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35433934

RESUMO

Background: Controlled attenuation parameter (CAP) without the guidance of the grey scale sonogram was a classic method in the quantitative evaluation of liver steatosis, it is recommended by international guidelines. Our study aimed to compare the diagnostic efficiency of a new real-time visual liver steatosis analysis (LiSA) versus CAP in chronic hepatitis B patients with liver steatosis. Methods: Patients were enrolled who underwent liver biopsy and received both LiSA (Hepatus, Mindray, probe LFP5-1U/s, China) and CAP (FibroScan502, Echosens, probe M, France) measurement simultaneously in our hospital from November 2018 to December 2019. The obtained values were both expressed as dB/m. Based on the liver fat content validated by liver biopsy, these patients were divided into the S0 group (fat content <5%) and S1 group (fat content ≥5%). The efficiency of the LiSA and CAP value in the diagnosis of liver steatosis was evaluated. Independent factors influencing the LiSA value were predicted by correlation analysis and multiple linear regression analysis. Results: A total of 151 patients were included in the analysis according to the exclusion criteria from 304 enrolled liver biopsy chronic hepatitis B (CHB) patients. Both LiSA and CAP successfully differentiated the S0 group from the S1 group. Receiver operating characteristic (ROC) curves showed that both LiSA and CAP had good diagnostic performance [area under the ROC curve area under the curve (AUC) >0.7] in evaluating liver steatosis, while there was no significant difference between the 2 methods (AUC 0.825 vs. 0.798, P=0.067). Using the optimal cutoff point, the specificity and sensitivity of LiSA in diagnosing liver steatosis were 89.18% and 79.16%, respectively. The specificity and sensitivity of CAP in diagnosing liver steatosis were 87.20% and 76.31%, respectively. Conclusions: Both LiSA and CAP are efficient for evaluating liver steatosis noninvasively.

17.
Phys Med Biol ; 67(2)2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-35016159

RESUMO

Objective. To achieve fast magnetic resonance elastography (MRE) at a low frequency for better shear modulus estimation of the brain.Approach. We proposed a multiphase radial DENSE MRE (MRD-MRE) sequence and an improved GRASP algorithm utilizing the sparsity of the harmonic motion (SH-GRASP) for fast MRE at 20 Hz. For the MRD-MRE sequence, the initial position encoded by spatial modulation of magnetization (SPAMM) was decoded by an arbitrary number of readout blocks without increasing the number of phase offsets. Based on the harmonic motion, a modified total variation and temporal Fourier transform were introduced to utilize the sparsity in the temporal domain. Both phantom and brain experiments were carried out and compared with that from multiphase Cartesian DENSE-MRE (MCD-MRE), and conventional gradient echo sequence (GRE-MRE). Reconstruction performance was also compared with GRASP and compressed sensing.Main results. Results showed the scanning time of a fully sampled image with four phase offsets for MRD-MRE was only 1/5 of that from GRE-MRE. The wave patterns and estimated stiffness maps were similar to those from MCD-MRE and GRE-MRE. With SH-GRASP, the total scan time could be shortened by additional 4 folds, achieving a total acceleration factor of 20. Better metric values were also obtained using SH-GRASP for reconstruction compared with other algorithms.Significance. The MRD-MRE sequence and SH-GRASP algorithm can be used either in combination or independently to accelerate MRE, showing the potentials for imaging the brain as well as other organs.


Assuntos
Técnicas de Imagem por Elasticidade , Algoritmos , Encéfalo/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Movimento (Física) , Imagens de Fantasmas
18.
Cancers (Basel) ; 14(11)2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35681558

RESUMO

This study aimed to explore the added value of viscoelasticity measured by magnetic resonance elastography (MRE) in the prediction of Ki-67 expression in hepatocellular carcinoma (HCC) using a deep learning combined radiomics (DLCR) model. This retrospective study included 108 histopathology-proven HCC patients (93 males; age, 59.6 ± 11.0 years) who underwent preoperative MRI and MR elastography. They were divided into training (n = 87; 61.0 ± 9.8 years) and testing (n = 21; 60.6 ± 10.1 years) cohorts. An independent validation cohort including 43 patients (60.1 ± 11.3 years) was included for testing. A DLCR model was proposed to predict the expression of Ki-67 with cMRI, including T2W, DW, and dynamic contrast enhancement (DCE) images as inputs. The images of the shear wave speed (c-map) and phase angle (φ-map) derived from MRE were also fed into the DLCR model. The Ki-67 expression was classified into low and high groups with a threshold of 20%. Both c and φ values were ranked within the top six features for Ki-67 prediction with random forest selection, which revealed the value of MRE-based viscosity for the assessment of tumor proliferation status in HCC. When comparing the six CNN models, Xception showed the best performance for classifying the Ki-67 expression, with an AUC of 0.80 ± 0.03 (CI: 0.79-0.81) and accuracy of 0.77 ± 0.04 (CI: 0.76-0.78) when cMRI were fed into the model. The model with all modalities (MRE, AFP, and cMRI) as inputs achieved the highest AUC of 0.90 ± 0.03 (CI: 0.89-0.91) in the validation cohort. The same finding was observed in the independent testing cohort, with an AUC of 0.83 ± 0.03 (CI: 0.82-0.84). The shear wave speed and phase angle improved the performance of the DLCR model significantly for Ki-67 prediction, suggesting that MRE-based c and φ-maps can serve as important parameters to assess the tumor proliferation status in HCC.

19.
J Clin Transl Hepatol ; 10(6): 1077-1085, 2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36381093

RESUMO

Background and Aims: Liver stiffness (LS) measured by shear wave elastography (SWE) is often influenced by hepatic inflammation. The aim was to develop a dual-task convolutional neural network (DtCNN) model for the simultaneous staging of liver fibrosis and inflammation activity using 2D-SWE. Methods: A total of 532 patients with chronic hepatitis B (CHB) were included to develop and validate the DtCNN model. An additional 180 consecutive patients between December 2019 and April 2021 were prospectively included for further validation. All patients underwent 2D-SWE examination and serum biomarker assessment. A DtCNN model containing two pathways for the staging of fibrosis and inflammation was used to improve the classification of significant fibrosis (≥F2), advanced fibrosis (≥F3) as well as cirrhosis (F4). Results: Both fibrosis and inflammation affected LS measurements by 2D-SWE. The proposed DtCNN performed the best among all the classification models for fibrosis stage [significant fibrosis AUC=0.89 (95% CI: 0.87-0.92), advanced fibrosis AUC=0.87 (95% CI: 0.84-0.90), liver cirrhosis AUC=0.85 (95% CI: 0.81-0.89)]. The DtCNN-based prediction of inflammation activity achieved AUCs of 0.82 (95% CI: 0.78-0.86) for grade ≥A1, 0.88 (95% CI: 0.85-0.90) grade ≥A2 and 0.78 (95% CI: 0.75-0.81) for grade ≥A3, which were significantly higher than the AUCs of the single-task groups. Similar findings were observed in the prospective study. Conclusions: The proposed DtCNN improved diagnostic performance compared with existing fibrosis staging models by including inflammation in the model, which supports its potential clinical application.

20.
Front Oncol ; 12: 962272, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36518314

RESUMO

Background: Glypican-3 (GPC3) expression is investigated as a promising target for tumor-specific immunotherapy of hepatocellular carcinoma (HCC). This study aims to determine whether GPC3 alters the viscoelastic properties of HCC and whether tomoelastography, a multifrequency magnetic resonance elastography (MRE) technique, is sensitive to it. Methods: Ninety-five participants (mean age, 58 ± 1 years; 78 men and 17 women) with 100 pathologically confirmed HCC lesions were enrolled in this prospective study from July 2020 to August 2021. All patients underwent preoperative multiparametric MRI and tomoelastography. Tomoelastography provided shear wave speed (c, m/s) representing tissue stiffness and loss angle (φ, rad) relating to viscosity. Clinical, laboratory, and imaging parameters were compared between GPC3-positive and -negative groups. Univariable and multivariable logistic regression were performed to determine factors associated with GPC3-positive HCC. The diagnostic performance of combined biomarkers was established using logistic regression analysis. Area-under-the-curve (AUC) analysis was done to assess diagnostic performance in detecting GPC3-positive HCC. Findings: GPC3-positive HCCs (n=72) had reduced stiffness compared with GPC3-negative HCCs (n=23) while viscosity was not different (c: 2.34 ± 0.62 versus 2.72 ± 0.62 m/s, P=0.010, φ: 1.11 ± 0.21 vs 1.18 ± 0.27 rad, P=0.21). Logistic regression showed c and elevated serum alpha-fetoprotein (AFP) level above 20 ng/mL were independent factors for GPC3-positive HCC. Stiffness with a cutoff of c = 2.8 m/s in conjunction with an elevated AFP yielded a sensitivity of 80.3%, specificity of 70.8%, and AUC of 0.80. Interpretation: Reduced stiffness quantified by tomoelastography may be a mechanical signature of GPC3-positive HCC. Combining reduced tumor stiffness and elevated AFP level may provide potentially valuable biomarker for GPC3-targeted immunotherapy.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa