Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Microsc Microanal ; : 1-9, 2022 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-35289265

RESUMO

The occurrence of multi-hit events and the separation distance between multi-hit ion pairs field evaporated from III-nitride semiconductors can potentially provide insights on neighboring chemistry, crystal structure, and field conditions. In this work, we quantify the range of variation in major III-N and III-III ion-pair separation to establish correlations with bulk composition, growth method, and ion-pair chemistry. The analysis of ion-pair separation along the AlGaN/GaN heterostructure system allows for comparison of Ga-N and Ga-Ga ion-pair separation between events evaporated from pure GaN and Al0.3Ga0.7N. From this, we aim to define a relative measure for the bond length of ion pairs within an AlGaN/GaN heterostructure. The distributions of pair separation revealed a distinct bimodal behavior that is unique to Al-N2+ ion pairs, suggesting the occurrence of both co-evaporation and molecular dissociation. Finally, we demonstrated that the two modes of ion-pair events align with the known variation in the surface electric field of the AlGaN(0001) structure. These findings demonstrate the utility of atom probe tomography in studying the crystallographic nature of nitride semiconductors.

2.
Microsc Microanal ; 26(1): 95-101, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32014067

RESUMO

In this work, the correlation between composition and relative evaporation field was investigated by tracking the statistics of multi-hit detector events in atom probe tomography (APT). This approach is applied systematically to a GaN-based nitride heterostructure with five AlxGa1-xN layers of varying Al composition. The relative field evaporation and the percentage of multi-hit events were found to increase with higher Al concentration. Furthermore, the comparison of the relative evaporation fields of AlN with respect to the constituent ions is found to be less than GaN with respect to its constituent ions. Despite equivalent compositions between opposing interfaces of the same AlxGa1-xN interlayer, the rate of change in multiplicity exhibits a consistent asymmetric trend with a steeper slope across the AlxGa1-xN/GaN interface compared to the GaN/AlxGa1-xN interface. The AlxGa1-xN/GaN heterostructure serves as a test structure for exploring field evaporation and neighborhood chemistry, which can be applied to any material chemistry and particularly other nitride systems.

3.
J Asthma ; 56(7): 719-730, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-29972657

RESUMO

OBJECTIVE: Nighttime wakening with asthma symptoms is a key to assessment and therapy decisions, with no gold standard objective measure. The study aims were to (1) determine the feasibility, (2) explore equivalence, and (3) test concordance of a consumer-based accelerometer with standard actigraphy for measurement of sleep patterns in women with asthma as an adjunct to self-report. METHODS: Panel study design of women with poorly controlled asthma from a university-affiliated primary care clinic system was used. We assessed sensitivity and specificity, equivalence and concordance of sleep time, sleep efficiency, and wake counts between the consumer-based accelerometer Fitbit Charge™ and Actigraph wGT3X+. We linked data between devices for comparison both automatically by 24-hour period and manually by sleep segment. RESULTS: Analysis included 424 938 minutes, 738 nights, and 833 unique sleep segments from 47 women. The fitness tracker demonstrated 97% sensitivity and 40% specificity to identify sleep. Between device equivalence for total sleep time (15 and 42-minute threshold) was demonstrated by sleep segment. Concordance improved for wake counts and sleep efficiency when adjusting for a linear trend. CONCLUSIONS: There were important differences in total sleep time, efficiency, and wake count measures when comparing individual sleep segments versus 24-hour measures of sleep. Fitbit overestimates sleep efficiency and underestimates wake counts in this population compared to actigraphy. Low levels of systematic bias indicate the potential for raw measurements from the devices to achieve equivalence and concordance with additional processing, algorithm modification, and modeling. Fitness trackers offer an accessible and inexpensive method to quantify sleep patterns in the home environment as an adjunct to subjective reports, and require further informatics development.


Assuntos
Actigrafia , Asma/fisiopatologia , Monitores de Aptidão Física , Polissonografia , Sono/fisiologia , Adolescente , Adulto , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Adulto Jovem
4.
Arch Oral Biol ; 112: 104682, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32126356

RESUMO

OBJECTIVE: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. DESIGN: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). These samples were analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. RESULTS: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ∼1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. CONCLUSION: The presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.


Assuntos
Esmalte Dentário/ultraestrutura , Tomografia , Animais , Bovinos , Incisivo , Microscopia Eletrônica de Varredura
5.
Heart Lung ; 49(5): 548-555, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32089295

RESUMO

BACKGROUND: Night-time wakening with asthma symptoms is an important indicator of disease control and severity, with no gold-standard objective measurement. OBJECTIVE: The study objective was to use fitness tracker sleep data to develop predictive models of daily disease control-related asthma-specific wakening and FEV1 in working-aged women with poorly controlled asthma. METHODS: A repeated measures panel design included data from 43 women with poorly controlled asthma. Two components of asthma control were the primary outcomes, measured daily as (1) self-reported asthma-specific wakening and (2) self-administered spirometry to measure FEV1. Data were analyzed using generalized linear mixed models. RESULTS: Our models demonstrated predictive value (AUC=0.77) for asthma-specific night-time wakening and good predictive value (AUC=0.83) for daily FEV1. CONCLUSIONS: Fitness tracker sleep efficiency and wake counts demonstrate clinical utility as predictive of asthma-specific night-time wakening and daily FEV1. Fitness tracker sleep data demonstrated predictive capability for daily asthma outcomes.


Assuntos
Asma , Monitores de Aptidão Física , Idoso , Asma/diagnóstico , Feminino , Volume Expiratório Forçado , Humanos , Testes de Função Respiratória , Sono , Espirometria
6.
Sci Rep ; 10(1): 1426, 2020 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-31996741

RESUMO

We report on the enhanced incorporation efficiency of magnesium dopants into facets of hexagonal hillock structures in N-polar GaN, studied by comparative analysis of GaN:Mg films grown by MOCVD on high and low hillock density GaN template layers. Total magnesium concentration in planar regions surrounding a hillock structure is comparable to that within hillock sidewall facets measured at 1.3 × 1019 cm-3 by atom probe tomography, and clustering of Mg atoms is seen in all regions of the film. Within individual hillock structures a decreased Mg cluster density is observed within hillock structures as opposed to the planar regions surrounding a hillock. Additionally, the Mg cluster radius is decreased within the hillock sidewall. The favorable incorporation of Mg is attributed to Mg dopants incorporating substitutionally for Ga during growth of semi-polar facets of the hillock structures. Enhanced p-type conductivity of GaN:Mg films grown on high hillock density template layers is verified by optical and electrical measurement.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa