RESUMO
OBJECTIVES: We evaluated fetal cardiovascular physiology and mode of cardiac failure in premature miniature piglets on a pumped artificial placenta (AP) circuit. METHODS: Fetal pigs were cannulated via the umbilical vessels and transitioned to an AP circuit composed of a centrifugal pump and neonatal oxygenator and maintained in a fluid-filled biobag. Echocardiographic studies were conducted to measure ventricular function, umbilical blood flow, and fluid status. In utero scans were used as control data. RESULTS: AP fetuses (n = 13; 102±4d gestational age [term 115d]; 616 ± 139 g [g]; survival 46.4 ± 46.8 h) were tachycardic and hypertensive with initially supraphysiologic circuit flows. Increased myocardial wall thickness was observed. Signs of fetal hydrops were present in all piglets. Global longitudinal strain (GLS) measurements increased in the left ventricle (LV) after transition to the circuit. Right ventricle (RV) and LV strain rate decreased early during AP support compared with in utero measurements but recovered toward the end of the experiment. Fetuses supported for >24 h had similar RV GLS to in utero controls and significantly higher GLS compared to piglets surviving only up to 24 h. CONCLUSIONS: Fetuses on a pump-supported AP circuit experienced an increase in afterload, and redistribution of blood flow between the AP and systemic circulations, associated with elevated end-diastolic filling pressures. This resulted in heart failure and hydrops. These preterm fetuses were unable to tolerate the hemodynamic changes associated with connection to the current AP circuit. To better mimic the physiology of the native placenta and preserve normal fetal cardiovascular physiology, further optimization of the circuit will be required.
Assuntos
Órgãos Artificiais , Ecocardiografia , Placenta , Porco Miniatura , Animais , Feminino , Suínos , Gravidez , Placenta/diagnóstico por imagem , Placenta/irrigação sanguínea , Ecocardiografia/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico por imagem , Animais Recém-Nascidos , Fenômenos Fisiológicos Cardiovasculares , Hidropisia Fetal/diagnóstico por imagem , Hidropisia Fetal/fisiopatologiaRESUMO
KEY POINTS: The application of fetal cardiovascular magnetic resonance imaging (CMR) to assess fetal cardiovascular physiology and cardiac function through the quantification of ventricular volumes has previously been investigated, but the approach has not yet been fully validated. Ventricular output measurements calculated from heart rate and stroke volumes (SV) of the right and left ventricles measured by ventricular volumetry (VV) exhibited a high level of agreement with phase-contrast (PC) blood flow measurements in the main pulmonary artery and ascending aorta, respectively. Ejection fraction of the right ventricle, which is lower than that of the left ventricle in postnatal subjects, was similar to the left ventricular ejection fraction in the fetus; probably due to the different loading conditions present in the fetal circulation. This study provides evidence to support the reliability of VV in the sheep fetus, providing evidence for its use in animal models of human diseases affecting the fetal circulation. ABSTRACT: The application of ventricular volumetry (VV) by cardiovascular magnetic resonance imaging (CMR) in the fetus remains challenging due to the small size of the fetal heart and high heart rate. The reliability of this technique in utero has not yet been established. The aim of this study was to assess the feasibility and reliability of VV in a fetal sheep model of human pregnancy. Right and left ventricular outputs by stroke volume (SV) measured using VV were compared with 2D phase-contrast (PC) CMR measurements of blood flow in the main pulmonary artery (MPA) and ascending aorta (AAo). At 124-140 days (d) gestation, singleton bearing Merino ewes underwent CMR under general anaesthesia using fetal femoral artery catheters, implanted at 109-117d, to trigger cine steady state free precession acquisitions of ventricular short-axis stacks. The short-axis cine stacks were segmented at end-systole and end-diastole, yielding right and left ventricular SV, ejection fraction, and cardiac outputs (SV × heart rate). PC cine acquisitions of MPA and AAo were analysed to measure blood flow, which served as comparators for the right and left cardiac outputs by VV. There was good correlation and agreement between VV and PC measures of ventricular outputs with no significant bias (r2 = 0.926; P < 0.0001; Bias = -4.7 ± 10.5 ml min-1 kg-1 ; 95% limits of agreement: -15.9 to 25.2 ml min-1 kg-1 ). This study validates fetal VV by CMR in a large animal model of human pregnancy and provides preliminary reference values of fetal sheep right and left ventricles in late gestation.
Assuntos
Ventrículos do Coração , Função Ventricular Esquerda , Animais , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Gravidez , Artéria Pulmonar , Reprodutibilidade dos Testes , Ovinos , Volume SistólicoRESUMO
BACKGROUND: Brain injury, impaired brain growth, and long-term neurodevelopmental problems are common in children with transposition of the great arteries. We sought to identify clinical risk factors for brain injury and poor brain growth in infants with transposition of the great arteries undergoing the arterial switch operation, and to examine their relationship with neurodevelopmental outcome. METHODS: The brains of 45 infants with transposition of the great arteries undergoing surgical repair were imaged pre- and postoperatively using magnetic resonance imaging. Brain weight z scores were calculated based on brain volume and autopsy reference data. Brain injury scores were determined as previously described. Neurodevelopment was assessed at 18 months using the Bayley-III scores of infant development. The relationships between clinical variables, brain injury, perioperative brain growth, and 18-month Bayley-III scores were analyzed. RESULTS: On preoperative imaging, moderate or severe white matter injury was present in 10 of 45 patients, whereas stroke was seen in 4 of 45. A similar prevalence of injury was seen on postoperative imaging, and we were unable to identify any clinical risk factors for brain injury. Brain weight z scores decreased perioperatively in 35 of 45 patients. The presence of a ventricular septal defect ( P=0.009) and older age at surgery ( P=0.007) were associated with impaired perioperative brain growth. When patients were divided into those undergoing surgery during the first 2 weeks of life (32/45) versus those being repaired later (13/45), infants repaired later had significantly worse perioperative brain growth (late repair postoperative brain weight z = -1.0±0.90 versus early repair z = -0.33±0.64; P=0.008). Bayley-III testing scores fell within the normal range for all patients, although age at repair ( P=0.03) and days of open chest ( P=0.03) were associated with a lower composite language score, and length of stay was associated with a lower composite cognitive score ( P=0.02). CONCLUSIONS: Surgery beyond 2 weeks of age is associated with impaired brain growth and slower language development in infants with transposition of the great arteries cared for at our center. Although the mechanisms underlying this association are still unclear, extended periods of cyanosis and pulmonary overcirculation may adversely impact brain growth and subsequent neurodevelopment.
Assuntos
Transposição das Grandes Artérias , Encefalopatias/etiologia , Encéfalo/crescimento & desenvolvimento , Desenvolvimento Infantil , Transposição dos Grandes Vasos/cirurgia , Fatores Etários , Autopsia , Encéfalo/diagnóstico por imagem , Encefalopatias/diagnóstico por imagem , Encefalopatias/fisiopatologia , Linguagem Infantil , Imagem de Difusão por Ressonância Magnética , Humanos , Lactente , Comportamento do Lactente , Recém-Nascido , Ontário , Tamanho do Órgão , Estudos Prospectivos , Fatores de Tempo , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/diagnóstico por imagem , Resultado do TratamentoRESUMO
PURPOSE: To test and implement a motion-robust and respiratory-resolved 3D Radial Flow framework that addresses the need for rapid, high resolution imaging in neonatal patients with congenital heart disease. METHODS: A 4-point velocity encoding and 3D radial trajectory with double-golden angle ordering was combined with bulk motion correction (from projection center of mass) and respiration phase detection (from principal component analysis of heartbeat-averaged data) to create motion-robust 3D velocity cardiac time-averaged data. This framework was tested in a whole-chest digital phantom with simulated bulk and realistic physiological motion. In vivo imaging was performed in 20 congenital heart disease infants under feed-and-sleep with submillimeter isotropic resolution in ~3 min. Flows were validated against clinical 2D PCMRI and whole-heart visualizations of blood flow were performed. RESULTS: The proposed framework resolved all simulated digital phantom motion states (mean ± standard error: rotation - azimuthal = 0.29 ± 0.02°; translation - Ty = 1.29 ± 0.12 mm, Tz = -0.27 ± 0.13 mm; rotation+translation - polar = 0.49 ± 0.16°, Tx = -2.47 ± 0.51 mm, Tz = 5.78 ± 1.33 mm). Measured timing errors of peak expiration across all signal-to-noise ratio values were 22% of the true respiratory period (range = [404-489 ± 298-334] ms). For in vivo imaging, motion correction improved 3D Radial Flow measurements (no correction: R2 = 0.62, root mean square error = 0.80 L/min/m2 , Bland-Altman bias [limits of agreement] = -0.21 [-1.40, 0.94] L/min/m2 ; motion corrected, expiration: R2 = 0.90, root mean square error = 0.46 L/min/m2 , bias [limits of agreement] = 0.06 [-0.49, 0.62] L/min/m2 ). Respiratory-resolved 3D velocity visualizations were achieved in various neonatal pathologies pre- and postsurgical correction. CONCLUSION: 3D cardiac flow may be visualized and accurately quantified in neonatal subjects using the proposed framework. This technique may enable more comprehensive hemodynamic studies in small infants.
Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Movimento (Física) , Neonatologia , Algoritmos , Artefatos , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem de Sincronização Cardíaca , Feminino , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Lactente , Recém-Nascido , Masculino , Modelos Teóricos , Imagens de Fantasmas , Reprodutibilidade dos Testes , RespiraçãoRESUMO
BACKGROUND: Doppler ultrasound measurements of the peak systolic velocity of the middle cerebral artery can be used to noninvasively diagnose fetal anemia but are less precise following fetal blood transfusion and in late gestation. We have previously demonstrated the feasibility of estimating fetal hematocrit in vitro using magnetic resonance imaging relaxation times. Here we report the use of magnetic resonance imaging as a noninvasive tool to accurately detect fetal anemia in vivo. OBJECTIVES: This study has 2 objectives: (1) to determine the feasibility and accuracy of magnetic resonance imaging in estimating hematocrit in anemic fetuses and (2) to compare magnetic resonance imaging and middle cerebral artery Doppler in detecting moderate to severe fetal anemia. STUDY DESIGN: Fetuses undergoing fetal blood sampling or transfusion underwent magnetic resonance imaging examinations prior to and following their procedures at 1.5 Tesla (Siemens Avanto). A modified Look-Locker inversion pulse sequence and T2 preparation sequence were applied for T1 and T2 mapping of the intrahepatic umbilical vein. Estimated fetal hematocrit was calculated using a combination of T1 and T2 values and compared with conventional hematocrit obtained from fetal blood samples and middle cerebral artery Doppler measurements. RESULTS: Twenty-three fetuses were assessed during 33 magnetic resonance imaging scans. The mean absolute difference between the laboratory and magnetic resonance imaging-estimated hematocrit was 0.06 ± 0.05 with a correlation of 0.77 (P < .001) determined by a multilevel, mixed-effects model adjusting for the repeated measurements from the same participants, multiple gestation pregnancies, and the scan type (ie, before or after transfusion scan). Bland-Altman analysis revealed a systematic bias of -0.03 between the magnetic resonance imaging and fetal blood sampling measurements. Magnetic resonance imaging and middle cerebral artery Doppler had similar sensitivities of approximately 90% to detect moderate to severe anemia. However, magnetic resonance imaging had a higher specificity (93% [13/14], 95% confidence interval, 66-100%) than Doppler (71% [10/14], 95% confidence interval, 42-92%). CONCLUSION: Moderate to severe fetal anemia can be detected noninvasively by magnetic resonance imaging with high sensitivity and specificity. Our results suggest an adjunct role for magnetic resonance imaging in fetuses with suspected anemia, particularly following previous transfusion and in late gestation.
Assuntos
Anemia/diagnóstico por imagem , Doenças Fetais/diagnóstico por imagem , Hematócrito , Artéria Cerebral Média/diagnóstico por imagem , Anemia/diagnóstico , Anemia/terapia , Velocidade do Fluxo Sanguíneo , Incompatibilidade de Grupos Sanguíneos/complicações , Transfusão de Sangue Intrauterina , Estudos Transversais , Feminino , Sangue Fetal/metabolismo , Doenças Fetais/diagnóstico , Doenças Fetais/terapia , Transfusão Feto-Fetal/complicações , Transfusão Feto-Fetal/terapia , Humanos , Imageamento por Ressonância Magnética , Gravidez , Estudos Prospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Ultrassonografia DopplerRESUMO
OBJECTIVES: The aims of this study were to: i) determine the spectrum of brain injury and ii) compare brain volumes between pre- and postoperative brain MRI in the infants receiving extracorporeal membrane oxygenation compared with those who did not require extracorporeal membrane oxygenation. DESIGN: Cohort study of infants with D-transposition of the great arteries or single ventricle physiology. Brain volume (cm) was measured using a segmentation of a volumetric T1-weighted gradient echo sequence. Brain imaging findings (intraventricular hemorrhage, white matter injuries, and stroke) were analyzed with respect to known clinical risk factors for brain injury and adverse neurodevelopmental outcomes. Clinical factors were collected by retrospective chart review. The association between brain volume and extracorporeal membrane oxygenation was evaluated using generalized estimating equations to account for repeated measures. SETTING: Prospective and single-centered study. PATIENTS: One hundred nine infants (median gestational age, 39.1 wk) with D-transposition of the great arteries (n = 77) or single ventricle physiology (n = 32) were studied pre- and postoperatively with MRI as per clinical protocol. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Of the 28 infants (26%) receiving extracorporeal membrane oxygenation, 19 (68%) were supported with extracorporeal membrane oxygenation once, and nine (32%) were supported 2-4 times. On postoperative MRI, new white matter injury was found in only five (17%) of the extracorporeal membrane oxygenation infants versus 40 (49%) in the non-extracorporeal membrane oxygenation group (p = 0.073). The rate of stroke (9% vs 10%), intraventricular hemorrhage (24% vs 29%), and hypoxic ischemia (3% vs 14%) did not differ between the non-extracorporeal membrane oxygenation and extracorporeal membrane oxygenation groups (all p > 0.5). Accounting for D-transposition of the great arteries or single ventricle physiology diagnosis, infants requiring extracorporeal membrane oxygenation had slower brain volume with single (ß = -1.67) or multiple extracorporeal membrane oxygenation runs ([ß = -6.54]; overall interaction p = 0.012). CONCLUSIONS: Patients with d-transposition of the great arteries or single ventricle physiology undergoing extracorporeal membrane oxygenation at our center have a similar incidence of brain injury but more significant impairment of perioperative brain volumes than those not requiring extracorporeal membrane oxygenation.
Assuntos
Oxigenação por Membrana Extracorpórea , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Adulto , Encéfalo/diagnóstico por imagem , Estudos de Coortes , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Lactente , Estudos Prospectivos , Estudos RetrospectivosRESUMO
BACKGROUND: Fetuses with cyanotic congenital heart disease (CHD) exhibit profound fetal circulatory disturbances that may affect early outcomes. OBJECTIVES: This study sought to investigate the relationship between fetal hemodynamics and early survival and neurodevelopmental (ND) outcomes in patients with cyanotic CHD. METHODS: In this longitudinal observational study, fetuses with cyanotic CHD underwent late gestational fetal cardiovascular magnetic resonance (CMR) to measure vessel blood flow and oxygen content. Superior vena cava (SVC) flow was used as a proxy for cerebral blood flow. Primary outcomes were 18-month mortality and Bayley Scales of Infant Development-III assessment. RESULTS: A total of 144 fetuses with cyanotic CHD were assessed. By 18 months, 18 patients (12.5%) died. Early mortality was associated with reduced combined ventricular output (P = 0.01), descending aortic flow (P = 0.04), and umbilical vein flow (P = 0.03). Of the surviving patients, 71 had ND outcomes assessed. Cerebral oxygen delivery was the fetal hemodynamic variable most strongly associated with cognitive, language, and motor outcomes (P < 0.05). Fetal SVC flow was also associated with cognitive, language, and motor outcomes (P < 0.01), and it remained an independent predictor of cognitive (P = 0.002) and language (P = 0.04) outcomes after adjusting for diagnosis. Diminished SVC flow also performed better than other fetal CMR and echocardiographic predictors of cognitive ND delay (receiver-operating characteristic curve area: 0.85; SE 0.05). CONCLUSIONS: Among fetuses with cyanotic CHD, diminished fetal combined ventricular output is associated with mortality, whereas cerebral blood flow and oxygen delivery are associated with early cognitive, language, and motor development at 18 months of age. These results support the inclusion of fetal CMR to help identify patients at risk of adverse ND outcomes.
Assuntos
Cardiopatias Congênitas , Veia Cava Superior , Gravidez , Lactente , Feminino , Criança , Humanos , Veia Cava Superior/diagnóstico por imagem , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Hemodinâmica/fisiologia , Feto , OxigênioRESUMO
Continuous data capture technology is becoming more common. Establishing analytic approaches for continuous data could aid in understanding the relationship between physiology and clinical outcomes. OBJECTIVES: Our objective was to design a retrospective analysis for continuous physiologic measurements and their relationship with new brain injury over time after cardiac surgery. DESIGN SETTING AND PARTICIPANTS: Retrospective cohort study in the Cardiac Critical Care Unit at the Hospital for Sick Children in patients after repair of transposition of the great arteries (TGA) or single ventricle (SV) lesions. MAIN OUTCOMES AND MEASURES: Continuously acquired physiologic measurements for up to 72 hours after cardiac surgery were analyzed for association with new brain injury by MRI. Distributions of heart rate (HR), systolic blood pressure (BP), and oxygen saturation (Spo2) for SV and TGA were analyzed graphically and with descriptive statistics over postoperative time for data-driven variable selection. Mixed-effects regression analyses characterized relationships between HR, BP, and Spo2 and new brain injury over time while accounting for variation between patients, measurement heterogeneity, and missingness. RESULTS: Seventy-seven patients (60 TGA; 17 SV) were included. New brain injury was seen in 26 (34%). In SV patients, with and without new brain injury, respectively, in the first 24 hours after cardiac surgery, the median (interquartile range) HR was 172.0 beats/min (bpm) (169.7-176.0 bpm) versus 159.6 bpm (145.0-167.0 bpm); systolic BP 74.8 (67.9-78.5 mm Hg) versus 68.9 mm Hg (61.6-70.9 mm Hg). Higher postoperative HR (parameter estimate, 19.4; 95% CI, 7.8-31; p = 0.003 and BP, 8.6; 1.3-15.8; p = 0.024) were associated with new brain injury in SV patients. The strength of this relationship decreased with time. CONCLUSIONS AND RELEVANCE: Retrospective analysis of continuous physiologic measurements can provide insight into changes in postoperative physiology over time and their relationship with new brain injury. This technique could be applied to assess relationships between physiologic data and many patient interventions or outcomes.
RESUMO
The recent demonstration of normal development of preterm sheep in an artificial extrauterine environment has renewed interest in artificial placenta (AP) systems as a potential treatment strategy for extremely preterm human infants. However, the feasibility of translating this technology to the human preterm infant remains unknown. Here we report the support of 13 preterm fetal pigs delivered at 102 ± 4 days (d) gestation, weighing 616 ± 139 g with a circuit consisting of an oxygenator and a centrifugal pump, comparing these results with our previously reported pumpless circuit (n = 12; 98 ± 4 days; 743 ± 350 g). The umbilical vessels were cannulated, and fetuses were supported for 46.4 ± 46.8 h using the pumped AP versus 11 ± 13 h on the pumpless AP circuit. Upon initiation of AP support on the pumped system, we observed supraphysiologic circuit flows, tachycardia, and hypertension, while animals maintained on a pumpless AP circuit exhibited subphysiologic flows. On the pumped AP circuit, there was a progressive decline in umbilical vein (UV) flow and oxygen delivery. We conclude that the addition of a centrifugal pump to the AP circuit improves survival of preterm pigs by augmenting UV flow through the reduction of right ventricular afterload. However, we continued to observe the development of heart failure within a matter of days.
RESUMO
OBJECTIVE: To test the hypothesis that delayed brain development in fetuses with d-transposition of the great arteries or hypoplastic left heart syndrome heightens their postnatal susceptibility to acquired white matter injury. METHODS: This is a cohort study across 3 sites. Subjects underwent fetal (third trimester) and neonatal preoperative magnetic resonance imaging of the brain to measure total brain volume as a measure of brain maturity and the presence of acquired white matter injury after birth. White matter injury was categorized as no-mild or moderate-severe based on validated grading criteria. Comparisons were made between the injury groups. RESULTS: A total of 63 subjects were enrolled (d-transposition of the great arteries: 37; hypoplastic left heart syndrome: 26). White matter injury was present in 32.4% (n = 12) of d-transposition of the great arteries and 34.6% (n = 8) of those with hypoplastic left heart syndrome. Overall total brain volume (taking into account fetal and neonatal scan) was significantly lower in those with postnatal moderate-severe white matter injury compared with no-mild white matter injury after adjusting for age at scan and site in d-transposition of the great arteries (coefficient: 14.8 mL, 95% confidence interval, -28.8 to -0.73, P = .04). The rate of change in total brain volume from fetal to postnatal life did not differ by injury group. In hypoplastic left heart syndrome, no association was noted between overall total brain volume and change in total brain volume with postnatal white matter injury. CONCLUSIONS: Lower total brain volume beginning in late gestation is associated with increased risk of postnatal moderate-severe white matter injury in d-transposition of the great arteries but not hypoplastic left heart syndrome. Rate of brain growth was not a risk factor for white matter injury. The underlying fetal and perinatal physiology has different implications for postnatal risk of white matter injury.
Assuntos
Encéfalo/crescimento & desenvolvimento , Síndrome do Coração Esquerdo Hipoplásico/complicações , Leucoencefalopatias/etiologia , Transposição dos Grandes Vasos/complicações , Encéfalo/diagnóstico por imagem , Canadá , Feminino , Desenvolvimento Fetal , Idade Gestacional , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Recém-Nascido , Leucoencefalopatias/diagnóstico por imagem , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Tamanho do Órgão , Gravidez , Diagnóstico Pré-Natal , Estudos Prospectivos , Medição de Risco , Fatores de Risco , São Francisco , Transposição dos Grandes Vasos/diagnóstico por imagemRESUMO
Artificial placenta (AP) technology aims to maintain fetal circulation, while promoting the physiologic development of organs. Recent reports of experiments performed in sheep indicate the intrauterine environment can be recreated through the cannulation of umbilical vessels, replacement of the placenta with a low-resistance membrane oxygenator, and incubation of the fetus in fluid. However, it remains to be seen whether animal fetuses similar in size to the extremely preterm human infant that have been proposed as a potential target for this technology can be supported in this way. Preterm Yucatan miniature piglets are similar in size to extremely preterm human infants and share similar umbilical cord anatomy, raising the possibility to serve as a good model to investigate the AP. To characterize fetal cardiovascular physiology, the carotid artery (n = 24) was cannulated in utero and umbilical vein (UV) and umbilical artery were sampled. Fetal UV flow was measured by MRI (n = 16). Piglets were delivered at 98 ± 4 days gestation (term = 115 days), cannulated, and supported on the AP (n = 12) for 684 ± 228 min (range 195-3077 min). UV flow was subphysiologic (p = .002), while heart rate was elevated on the AP compared with in utero controls (p = .0007). We observed an inverse relationship between heart rate and UV flow (r2 = .4527; p < .001) with progressive right ventricular enlargement that was associated with reduced contractility and ultimately hydrops and circulatory collapse. We attribute this to excessive afterload imposed by supraphysiologic circuit resistance and augmented sympathetic activity. We conclude that short-term support of the preterm piglet on the AP is feasible, although we have not been able to attain normal fetal physiology. In the future, we propose to investigate the feasibility of an AP circuit that incorporates a centrifugal pump in our miniature pig model.
Assuntos
Feto/metabolismo , Insuficiência Cardíaca/metabolismo , Placenta/metabolismo , Cordão Umbilical/metabolismo , Animais , Feminino , Humanos , Modelos Animais , Gravidez , Cuidado Pré-Natal/métodos , SuínosRESUMO
OBJECTIVE: To investigate preoperative cerebral hemodynamics in newborns with congenital heart disease. We hypothesized that cerebral blood flow and oxygen delivery would be decreased in newborns with congenital heart disease compared with controls. METHODS: Using a "feed-and-sleep" approach to performing neonatal magnetic resonance imaging, we measured cerebral blood flow by using a slice prescription perpendicular to the right and left internal carotid arteries and basilar artery at the level of the clivus. We calculated brain volume by segmenting a 3-dimensional steady-state free procession acquisition of the whole brain, allowing quantification of cerebral blood flow indexed to brain volume. Cerebral oxygen delivery was calculated as the product of cerebral blood flow and preductal systemic arterial oxygen content obtained via a combination of conventional pulse oximetry and laboratory analysis of venous blood samples for hemoglobin concentration. RESULTS: A complete set of measurements were obtained in 32 newborns with heart disease and 31 controls. There was no difference in gestational age between the heart disease and control groups. There was no difference in cerebral blood flow compared with controls (103.5 ± 34.0 vs 119.7 ± 40.4 mL/min), whereas cerebral oxygen delivery was significantly lower in the congenital heart disease subjects (1881 ± 625.7 vs 2712 ± 915.7 mLO2/min). Ten newborns with congenital heart disease had diffuse excessive high signal intensity in their white matter and 2 had white matter injury whereas another 5 had both. CONCLUSIONS: Newborns with unrepaired cyanotic congenital heart disease have decreased cerebral oxygen delivery due to arterial desaturation. If brain growth and development are adversely affected through oxygen conformance, our findings could have clinical implications in terms of timing of surgical repair.