Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem ; 55(12): 2207-13, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19850631

RESUMO

BACKGROUND: Succinylacetone (SUAC) is the primary metabolite accumulated in tyrosinemia type I--an inborn error of metabolism that, if untreated, can cause death from liver failure during the first months of life. Newborn screening laboratories measure SUAC in dried blood spot (DBS) samples to detect asymptomatic tyrosinemia type I. We used panels of SUAC-enriched DBSs to compare and evaluate the performance of these screening tests. METHODS: We prepared sets of DBS materials enriched with predetermined SUAC concentrations and distributed samples of these materials, along with a screening practices questionnaire, to laboratories that perform SUAC tests. We compared their reported SUAC concentrations and questionnaire responses to identify screening practices that affect SUAC test outcomes. RESULTS: Data from 2 pilot surveys showed large differences among laboratories in SUAC recoveries, reproducible within-laboratory recoveries, and stable performance of the DBS materials. Results from 257 proficiency test analyses contained a total of 6 false-negative misclassifications. Reported recoveries of added SUAC ranged from 0 to >200%. Low-biased SUAC recoveries were associated with 1 method used by 5 laboratories. All laboratories that reported SUAC recoveries > or =100% used DBS matrix calibrators. CONCLUSIONS: The wide ranges of SUAC concentrations reported for pilot and proficiency testing specimens demonstrate a need to harmonize quantitative results among laboratories. Although DBS matrix calibrators are important for optimizing SUAC recoveries, the preparation of these calibrators is not standardized among laboratories. Certified DBS-based SUAC calibrators are needed for accuracy and harmonization.


Assuntos
Heptanoatos/sangue , Triagem Neonatal/métodos , Tirosinemias/diagnóstico , Coleta de Amostras Sanguíneas , Humanos , Recém-Nascido , Laboratórios , Projetos Piloto , Garantia da Qualidade dos Cuidados de Saúde , Inquéritos e Questionários , Tirosinemias/sangue
2.
Clin Chim Acta ; 412(15-16): 1385-90, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21514290

RESUMO

BACKGROUND: Markers derived from dextrose (d-glucose) are observed in the MS/MS-based acylcarnitine profiles from dried-blood spots of some premature infants receiving intravenous nutrition. The presence of these markers at m/z 325, 399 and 473 are thought to arise from contamination of blood by total parenteral nutrition (TPN) solutions during specimen collection from premature infants. These solutions contain high concentrations of amino acids and as a result, false-positive screening results for amino acid disorders may occur. This study investigates quantitative parameters of dextrose and amino acids in blood samples enriched with different TPN solutions. METHODS: Whole blood collected in heparin was enriched with three different TPN solutions containing 5, 10 or 12.5% dextrose and amino acids that were originally prepared for delivery of 2.5, 3 or 4 g/kg/day of Premasol® then spotted onto filter paper cards. Acylcarnitine and amino acid profiles using MS/MS were obtained. Ion ratios of dextrose relative to specific acylcarnitine stable isotope internal standards and amino acid concentrations were obtained. RESULTS: The ion ratios for each of the dextrose markers at m/z 325, 399 and 473 exhibit linearity with the concentration of the dextrose component of TPN added to blood. The lowest detectable dextrose concentration added to blood was 7.6 mmol/l at 1:80 v/v TPN in blood. Furthermore, the concentrations of amino acids were linear with the concentration of the amino acid component of TPN added to blood. At the lowest detectable concentrations of dextrose marker, the amino acid concentrations were at or above the values considered abnormal in newborn screening laboratories. The molar ratios of amino acids approached the relative quantity of amino acid in the TPN solution with increasing enrichments in blood. CONCLUSIONS: Detection of the combinations of dextrose markers, very high elevations of amino acids and unusual molar ratios can be used to reject a specimen as improperly collected rather than declaring it a false positive and hence reduce false positive rates. This process enhances efficiency, reduces parental anxiety, and improves positive predictive values.


Assuntos
Aminoácidos/sangue , Coleta de Amostras Sanguíneas , Triagem Neonatal , Nutrição Parenteral Total/métodos , Humanos , Recém-Nascido , Sensibilidade e Especificidade
3.
Clin Chim Acta ; 412(7-8): 631-5, 2011 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-21185274

RESUMO

BACKGROUND: The use of tandem mass spectrometry (MS/MS) for the analysis of amino acids and acylcarnitines from dried-blood spots (DBS) has become routine practice in newborn screening laboratories. The Newborn Screening Quality Assurance Program (NSQAP) added 3-hydroxyisovalerylcarnitine (C5OH) into its routine quality control and proficiency testing (PT) DBS materials for MS/MS to assure the quality of C5OH screening. We report the results from NSQAP evaluations for C5OH-enriched DBS, and summarize participant screening practices based on their analytical methods. METHODS: NSQAP prepared C5OH-enriched DBS materials for its participants. Laboratories reported quantitative and qualitative results. Bias plots of quantitative results were constructed using reported data and the results were sorted by an analytical method. RESULTS: NSQAP participants reported PT specimen 3964 as outside of normal limits for C5OH. The mean C5OH value for derivatized and non-derivatized methods was 2.80 and 2.67 µmol/l, respectively. Reported data from other specimens showed a similar trend in derivatized vs. non-derivatized assay results. Differences in C5OH quantitative values were observed among laboratories using different internal standards. CONCLUSIONS: C5OH MS/MS measurements in DBS assays varied by method and the choice of internal standards. The use of NSQAP's DBS materials allows harmonization of C5OH measurements by newborn screening laboratories worldwide.


Assuntos
Carnitina/análogos & derivados , Triagem Neonatal , Espectrometria de Massas em Tandem/métodos , Carnitina/sangue , Humanos , Recém-Nascido , Projetos Piloto , Garantia da Qualidade dos Cuidados de Saúde , Valores de Referência
4.
Clin Chim Acta ; 411(21-22): 1806-16, 2010 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-20707991

RESUMO

BACKGROUND: The false positive rate for the newborn screening of disorders of amino acid metabolism for premature infants is higher than full term infants. This may be due to very low birth weight infants receiving high concentrations of amino acids from total parenteral nutrition (TPN) administration and/or immature metabolism. An investigation of the possible influence of TPN on screening of premature infants resulted in the detection of three unusual peaks in the tandem mass spectrometry (MS/MS) acylcarnitine profile. These markers were closely correlated with the detection of very high multiple amino acid increases in the profiles of newborns administered with TPN and who were ultimately found to be normal and free of inherited metabolic disorders. METHODS: TPN solutions contain a concentrated mixture of amino acids and dextrose and other nutrients in saline. Due to its high concentration and suggestion of a carbohydrate, it was hypothesized that dextrose (D-glucose) was the contaminant and source of the markers detected. Dextrose, stable isotope-labeled 13C6-dextrose and various TPN solutions were analyzed directly or after enrichment in whole blood by multiple MS/MS acquisition modes including MS-only, product and precursor ion and neutral loss scans. RESULTS: Analysis of dried-blood spots (DBS) prepared from whole blood spiked with TPN solutions containing 12.5% dextrose and amino acid formulations designed to deliver 2.5 gm/kg/day of an amino acid mixture had moderate increases of all 3 dextrose markers detected at m/z 325, 399 and 473 as compared to controls. MS-only scans, product and precursor ion scans of dextrose and 13C6-dextrose in positive ion mode confirmed that these 3 peaks are derived from dextrose. Mass spectral analysis of labeled and unlabeled dextrose suggested that these peaks were dimers derived from dextrose. CONCLUSION: The identification of dextrose markers in DBS indicates that high concentrations of dextrose were present in blood and the likely source was contamination by TPN solutions most likely occurring during a sample collection process.


Assuntos
Glucose/análise , Triagem Neonatal/normas , Nutrição Parenteral Total , Aminoácidos/administração & dosagem , Aminoácidos/análise , Biomarcadores/sangue , Isótopos de Carbono , Reações Falso-Positivas , Glucose/administração & dosagem , Humanos , Lactente , Recém-Nascido , Espectrometria de Massas em Tandem/métodos
5.
Clin Chim Acta ; 411(9-10): 684-9, 2010 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-20122909

RESUMO

BACKGROUND: The analysis of amino acids (AA) and acylcarnitines (AC) by tandem mass spectrometry (MS/MS) is performed in newborn screening laboratories worldwide. While butyl esterification assays are routine, it is possible to detect AAs and ACs as their native free acids (underivatized). The Centers for Disease Control and Prevention's Newborn Screening Quality Assurance Program provides dried blood spot (DBS) quality control (QC) and proficiency testing (PT) programs for numerous MS/MS analytes. We describe empirical differences between derivatization and non-derivatization techniques for selected AAs and ACs. METHODS: DBS materials were prepared at levels near, above and below mean domestic laboratory cut-offs, and distributed to program participants for MS/MS analysis. Laboratories reported quantitative and qualitative results. QC DBS materials were assayed in-house following established protocols. RESULT: Minor differences (<15%) between quantitative values resulting from butyl esters and free acid techniques were observed for the majority of the analytes. Mass spectrometric response from underivatized dicarboxylic acid acylcarnitines was less intense than their butyl esters. CONCLUSIONS: The use of underivatized techniques may also result in the inability to differentiate isobaric acylcarnitines. Laboratories should establish their own protocols by focusing on the decisions that identify test results requiring additional follow-up testing versus those that do not.


Assuntos
Aminoácidos/análise , Carnitina/análogos & derivados , Triagem Neonatal/métodos , Espectrometria de Massas em Tandem/métodos , Aminoácidos/sangue , Aminoácidos/química , Butanóis/química , Carnitina/análise , Carnitina/sangue , Carnitina/química , Humanos , Recém-Nascido , Leucina/análise , Leucina/sangue , Leucina/química , Doenças Metabólicas/diagnóstico , Metionina/análise , Metionina/sangue , Metionina/química , Palmitoilcarnitina/análise , Palmitoilcarnitina/sangue , Palmitoilcarnitina/química , Fenilalanina/análise , Fenilalanina/sangue , Fenilalanina/química , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa