Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 18(12)2018 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-30513838

RESUMO

Pulse transit time (PTT) has received considerable attention for noninvasive cuffless blood pressure measurement. However, this approach is inconvenient to deploy in wearable devices because two sensors are required for collecting two-channel physiological signals, such as electrocardiogram and pulse wave signals. In this study, we investigated the pressure pulse wave (PPW) signals collected from one piezoelectric-induced sensor located at a single site for cuffless blood pressure estimation. Twenty-one features were extracted from PPW that collected from the radial artery, and then a linear regression method was used to develop blood pressure estimation models by using the extracted PPW features. Sixty-five middle-aged and elderly participants were recruited to evaluate the performance of the constructed blood pressure estimation models, with oscillometric technique-based blood pressure as a reference. The experimental results indicated that the mean ± standard deviation errors for the estimated systolic blood pressure and diastolic blood pressure were 0.70 ± 7.78 mmHg and 0.83 ± 5.45 mmHg, which achieved a decrease of 1.33 ± 0.37 mmHg in systolic blood pressure and 1.14 ± 0.20 mmHg in diastolic blood pressure, compared with the conventional PTT-based method. The proposed model also demonstrated a high level of robustness in a maximum 60-day follow-up study. These results indicated that PPW obtained from the piezoelectric sensor has great feasibility for cuffless blood pressure estimation, and could serve as a promising method in home healthcare settings.

2.
IEEE J Biomed Health Inform ; 28(7): 3882-3894, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38687656

RESUMO

Biosignals collected by wearable devices, such as electrocardiogram and photoplethysmogram, exhibit redundancy and global temporal dependencies, posing a challenge in extracting discriminative features for blood pressure (BP) estimation. To address this challenge, we propose HGCTNet, a handcrafted feature-guided CNN and transformer network for cuffless BP measurement based on wearable devices. By leveraging convolutional operations and self-attention mechanisms, we design a CNN-Transformer hybrid architecture to learn features from biosignals that capture both local information and global temporal dependencies. Then, we introduce a handcrafted feature-guided attention module that utilizes handcrafted features extracted from biosignals as query vectors to eliminate redundant information within the learned features. Finally, we design a feature fusion module that integrates the learned features, handcrafted features, and demographics to enhance model performance. We validate our approach using two large wearable BP datasets: the CAS-BP dataset and the Aurora-BP dataset. Experimental results demonstrate that HGCTNet achieves an estimation error of 0.9 ± 6.5 mmHg for diastolic BP (DBP) and 0.7 ± 8.3 mmHg for systolic BP (SBP) on the CAS-BP dataset. On the Aurora-BP dataset, the corresponding errors are -0.4 ± 7.0 mmHg for DBP and -0.4 ± 8.6 mmHg for SBP. Compared to the current state-of-the-art approaches, HGCTNet reduces the mean absolute error of SBP estimation by 10.68% on the CAS-BP dataset and 9.84% on the Aurora-BP dataset. These results highlight the potential of HGCTNet in improving the performance of wearable cuffless BP measurements.


Assuntos
Determinação da Pressão Arterial , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis , Humanos , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea/fisiologia , Algoritmos , Adulto , Masculino
3.
IEEE J Biomed Health Inform ; 27(9): 4216-4227, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37204948

RESUMO

This study aimed to evaluate the performance of cuffless blood pressure (BP) measurement techniques in a large and diverse cohort of participants. We enrolled 3077 participants (aged 18-75, 65.16% women, 35.91% hypertensive participants) and conducted followed-up for approximately 1 month. Electrocardiogram, pulse pressure wave, and multiwavelength photoplethysmogram signals were simultaneously recorded using smartwatches; dual-observer auscultation systolic BP (SBP) and diastolic BP (DBP) reference measurements were also obtained. Pulse transit time, traditional machine learning (TML), and deep learning (DL) models were evaluated with calibration and calibration-free strategy. TML models were developed using ridge regression, support vector machine, adaptive boosting, and random forest; while DL models using convolutional and recurrent neural networks. The best-performing calibration-based model yielded estimation errors of 1.33 ± 6.43 mmHg for DBP and 2.31 ± 9.57 mmHg for SBP in the overall population, with reduced SBP estimation errors in normotensive (1.97 ± 7.85 mmHg) and young (0.24 ± 6.61 mmHg) subpopulations. The best-performing calibration-free model had estimation errors of -0.29 ± 8.78 mmHg for DBP and -0.71 ± 13.04 mmHg for SBP. We conclude that smartwatches are effective for measuring DBP for all participants and SBP for normotensive and younger participants with calibration; performance degrades significantly for heterogeneous populations including older and hypertensive participants. The availability of cuffless BP measurement without calibration is limited in routine settings. Our study provides a large-scale benchmark for emerging investigations on cuffless BP measurement, highlighting the need to explore additional signals or principles to enhance the accuracy in large-scale heterogeneous populations.


Assuntos
Hipertensão , Fotopletismografia , Humanos , Feminino , Masculino , Pressão Sanguínea/fisiologia , Fotopletismografia/métodos , Determinação da Pressão Arterial/métodos , Análise de Onda de Pulso/métodos
4.
Artif Intell Med ; 108: 101919, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32972654

RESUMO

Continuous blood pressure (BP) measurement is crucial for reliable and timely hypertension detection. State-of-the-art continuous BP measurement methods based on pulse transit time or multiple parameters require simultaneous electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Compared with PPG signals, ECG signals are easy to collect using wearable devices. This study examined a novel continuous BP estimation approach using one-channel ECG signals for unobtrusive BP monitoring. A BP model is developed based on the fusion of a residual network and long short-term memory to obtain the spatial-temporal information of ECG signals. The public multiparameter intelligent monitoring waveform database, which contains ECG, PPG, and invasive BP data of patients in intensive care units, is used to develop and verify the model. Experimental results demonstrated that the proposed approach exhibited an estimation error of 0.07 ± 7.77 mmHg for mean arterial pressure (MAP) and 0.01 ± 6.29 for diastolic BP (DBP), which comply with the Association for the Advancement of Medical Instrumentation standard. According to the British Hypertension Society standards, the results achieved grade A for MAP and DBP estimation and grade B for systolic BP (SBP) estimation. Furthermore, we verified the model with an independent dataset for arrhythmia patients. The experimental results exhibited an estimation error of -0.22 ± 5.82 mmHg, -0.57 ± 4.39 mmHg, and -0.75 ± 5.62 mmHg for SBP, MAP, and DBP measurements, respectively. These results indicate the feasibility of estimating BP by using a one-channel ECG signal, thus enabling continuous BP measurement for ubiquitous health care applications.


Assuntos
Aprendizado Profundo , Pressão Sanguínea , Determinação da Pressão Arterial , Eletrocardiografia , Humanos , Fotopletismografia
5.
IEEE J Biomed Health Inform ; 24(1): 79-91, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-30892255

RESUMO

Ambulatory blood pressure (BP) provides valuable information for cardiovascular risk assessment. The present cuff-based devices are intrusive for long-term BP monitoring, whereas cuff-less BP measurement methods based on pulse transit time or multi-parameter are inferior in robustness and reliability by using electrocardiogram (ECG) and photoplethysmogram signals. This study examined a multi-sensor fusion-based platform and algorithm for systolic BP (SBP), mean arterial pressure (MAP), and diastolic BP (DBP) estimation. The proposed multi-sensor platform was comprised of one ECG sensor and two pulse pressure wave sensors for simultaneous signal collection. After extracting 35 features from the collected signals, a weakly supervised feature selection method was proposed for dimension reduction because the reference oscillometric technique-based BP are intermittent and can be redeemed as coarse-grained labels. BP models were then established using a multi-instance regression algorithm. A total of 85 participants including 17 hypertensive and 12 hypotensive patients were enrolled. Experimental results showed that the proposed approach exhibited good accuracy for diverse population with an estimation error of 1.62 ± 7.76 mmHg for SBP, 1.53 ± 6.03 mmHg for MAP, and 1.49 ± 5.52 for DBP, which complied with the association for the advancement of medical instrumentation standards in BP estimation. Moreover, the estimation accuracy is with random daily fluctuations rather than long-term degradation through a maximum two-month follow-up period indicated good robustness performance. These results suggest that the proposed approach is with high reliability and robustness and thus provides a novel insight for cuff-less BP measurement.


Assuntos
Determinação da Pressão Arterial/métodos , Análise de Onda de Pulso/métodos , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Pressão Sanguínea/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa