Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Clin Pathol ; 133(6): 870-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20472844

RESUMO

Ensuring accurate patient identification is central to preventing medical errors, but it can be challenging. We implemented a bar code-based positive patient identification system for use in inpatient phlebotomy. A before-after design was used to evaluate the impact of the identification system on the frequency of mislabeled and unlabeled samples reported in our laboratory. Labeling errors fell from 5.45 in 10,000 before implementation to 3.2 in 10,000 afterward (P = .0013). An estimated 108 mislabeling events were prevented by the identification system in 1 year. Furthermore, a workflow step requiring manual preprinting of labels, which was accompanied by potential labeling errors in about one quarter of blood "draws," was removed as a result of the new system. After implementation, a higher percentage of patients reported having their wristband checked before phlebotomy. Bar code technology significantly reduced the rate of specimen identification errors.


Assuntos
Erros Médicos/prevenção & controle , Sistemas de Identificação de Pacientes , Flebotomia/métodos , Centros Médicos Acadêmicos , Boston , Processamento Eletrônico de Dados , Humanos , Manejo de Espécimes/métodos , Fluxo de Trabalho
2.
Am J Clin Pathol ; 132(6): 914-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19926584

RESUMO

Our goals were to improve the overall patient experience and optimize the blood collection process in outpatient phlebotomy using Lean principles. Elimination of non-value-added steps and modifications to operational processes resulted in increased capacity to handle workload during peak times without adding staff. The result was a reduction of average patient wait time from 21 to 5 minutes, with the goal of drawing blood samples within 10 minutes of arrival at the phlebotomy station met for 90% of patients. In addition, patient satisfaction increased noticeably as assessed by a 5-question survey. The results have been sustained for 10 months with staff continuing to make process improvements.


Assuntos
Eficiência Organizacional , Ambulatório Hospitalar/organização & administração , Satisfação do Paciente , Flebotomia/métodos , Fluxo de Trabalho , Humanos , Pacientes Ambulatoriais , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa