Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Anat Sci Educ ; 17(4): 693-711, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38520153

RESUMO

Anatomical education is pivotal for medical students, and innovative technologies like augmented reality (AR) are transforming the field. This study aimed to enhance the interactive features of the AEducAR prototype, an AR tool developed by the University of Bologna, and explore its impact on human anatomy learning process in 130 second-year medical students at the International School of Medicine and Surgery of the University of Bologna. An interdisciplinary team of anatomists, maxillofacial surgeons, biomedical engineers, and educational scientists collaborated to ensure a comprehensive understanding of the study's objectives. Students used the updated version of AEducAR, named AEducAR 2.0, to study three anatomical topics, specifically the orbit zone, facial bones, and mimic muscles. AEducAR 2.0 offered two learning activities: one explorative and one interactive. Following each activity, students took a test to assess learning outcomes. Students also completed an anonymous questionnaire to provide background information and offer their perceptions of the activity. Additionally, 10 students participated in interviews for further insights. The results demonstrated that AEducAR 2.0 effectively facilitated learning and students' engagement. Students totalized high scores in both quizzes and declared to have appreciated the interactive features that were implemented. Moreover, interviews shed light on the interesting topic of blended learning. In particular, the present study suggests that incorporating AR into medical education alongside traditional methods might prove advantageous for students' academic and future professional endeavors. In this light, this study contributes to the growing research emphasizing the potential role of AR in shaping the future of medical education.


Assuntos
Anatomia , Realidade Aumentada , Educação de Graduação em Medicina , Avaliação Educacional , Aprendizagem , Estudantes de Medicina , Feminino , Humanos , Masculino , Adulto Jovem , Anatomia/educação , Instrução por Computador/métodos , Currículo , Educação de Graduação em Medicina/métodos , Avaliação Educacional/estatística & dados numéricos , Estudos Interdisciplinares , Estudantes de Medicina/psicologia , Estudantes de Medicina/estatística & dados numéricos , Inquéritos e Questionários/estatística & dados numéricos
2.
J Clin Med ; 12(24)2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38137603

RESUMO

Oral cavity defects occur after resection of lesions limited to the mucosa, alveolar gum, or minimally affecting the bone. Aiming at esthetical and functional improvements of intraoral reconstruction, the possibility of harvesting a new galeo-pericranial free flap was explored. The objective of this study was to assess the technical feasibility of flap harvesting through anatomical dissections and surgical procedure simulations. Ten head and neck specimens were dissected to simulate the surgical technique and evaluate the vascular calibers of temporal and cervical vessels. The procedure was therefore reproduced on a revascularized and ventilated donor cadaver. Anatomical dissections demonstrated that the mean cervical vascular calibers are compatible with superficial temporal ones, proving to be adequate for anastomosis. Perforating branches of the superficial temporal vascularization nourishing the pericranium were identified in all specimens. In conclusion, blood flow presence was recorded after anastomosing superficial temporal and facial vessels in the revascularized donor cadaver, demonstrating both this procedure's technical feasibility and the potential revascularization of the flap and therefore encouraging its potential in vivo application.

3.
Front Oncol ; 12: 1046505, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36338693

RESUMO

Objective: to evaluate the impact of 3D model for a comprehensive assessment of surgical planning and quality of partial nephrectomy (PN). Materials and methods: 195 patients with cT1-T2 renal mass scheduled for PN were enrolled in two groups: Study Group (n= 100), including patients referred to PN with revision of both 2D computed tomography (CT) imaging and 3D model; Control group (n= 95), including patients referred to PN with revision of 2D CT imaging. Overall, 20 individuals were switched to radical nephrectomy (RN). The primary outcome was the impact of 3D models-based surgical planning on Trifecta achievement (defined as the contemporary absence of positive surgical margin, major complications and ≤30% postoperative eGFR reduction). The secondary outcome was the impact of 3D models on surgical planning of PN. Multivariate logistic regressions were used to identify predictors of selective clamping and Trifecta's achievement in patients treated with PN (n=175). Results: Overall, 73 (80.2%) patients in Study group and 53 (63.1%) patients in Control group achieved the Trifecta (p=0.01). The preoperative plan of arterial clamping was recorded as clampless, main artery and selective in 22 (24.2%), 22 (24.2%) and 47 (51.6%) cases in Study group vs. 31 (36.9%), 46 (54.8%) and 7 (8.3%) cases in Control group, respectively (p<0.001). At multivariate logistic regressions, the use of 3D model was found to be independent predictor of both selective or super-selective clamping and Trifecta's achievement. Conclusion: 3D-guided approach to PN increase the adoption of selective clamping and better predict the achievement of Trifecta.

4.
Eur Urol Focus ; 7(6): 1260-1267, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32883625

RESUMO

BACKGROUND: Augmented reality (AR) is a novel technology adopted in prostatic surgery. OBJECTIVE: To evaluate the impact of a 3D model with AR (AR-3D model), to guide nerve sparing (NS) during robot-assisted radical prostatectomy (RARP), on surgical planning. DESIGN, SETTING, AND PARTICIPANTS: Twenty-six consecutive patients with diagnosis of prostate cancer (PCa) and multiparametric magnetic resonance imaging (mpMRI) results available were scheduled for AR-3D NS RARP. INTERVENTION: Segmentation of mpMRI and creation of 3D virtual models were achieved. To develop AR guidance, the surgical DaVinci video stream was sent to an AR-dedicated personal computer, and the 3D virtual model was superimposed and manipulated in real time on the robotic console. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The concordance of localisation of the index lesion between the 3D model and the pathological specimen was evaluated using a prostate map of 32 specific areas. A preliminary surgical plan to determinate the extent of the NS approach was recorded based on mpMRI. The final surgical plan was reassessed during surgery by implementation of the AR-3D model guidance. RESULTS AND LIMITATIONS: The positive surgical margin (PSM) rate was 15.4% in the overall patient population; three patients (11.5%) had PSMs at the level of the index lesion. AR-3D technology changed the NS surgical plan in 38.5% of men on patient-based and in 34.6% of sides on side-based analysis, resulting in overall appropriateness of 94.4%. The 3D model revealed 70%, 100%, and 92% of sensitivity, specificity, and accuracy, respectively, at the 32-area map analysis. CONCLUSIONS: AR-3D guided surgery is useful for improving the real-time identification of the index lesion and allows changing of the NS approach in approximately one out of three cases, with overall appropriateness of 94.4%. PATIENT SUMMARY: Augmented reality three-dimensional guided robot-assisted radical prostatectomy allows identification of the index prostate cancer during surgery, to tailor the surgical dissection to the index lesion and to change the extent of nerve-sparing dissection.


Assuntos
Realidade Aumentada , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Próstata/cirurgia , Prostatectomia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos
5.
Eur Urol ; 80(4): 480-488, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34332759

RESUMO

BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) can guide the surgical plan during robot-assisted radical prostatectomy (RARP), and intraoperative frozen section (IFS) can facilitate real-time surgical margin assessment. OBJECTIVE: To assess a novel technique of IFS targeted to the index lesion by using augmented reality three-dimensional (AR-3D) models in patients scheduled for nerve-sparing RARP (NS-RARP). DESIGN, SETTING, AND PARTICIPANTS: Between March 2019 and July 2019, 20 consecutive prostate cancer patients underwent NS-RARP with IFS directed to the index lesion with the help of AR-3D models (study group). Control group consists of 20 patients matched with 1:1 propensity score for age, clinical stage, Prostate Imaging Reporting and Data System score v2, International Society of Urological Pathology grade, prostate volume, NS approach, and prostate-specific antigen in which RARP was performed by cognitive assessment of mpMRI. SURGICAL PROCEDURE: In the study group, an AR-3D model was superimposed to the surgical field to guide the surgical dissection. Tissue sampling for IFS was taken in the area in which the index lesion was projected by AR-3D guidance. MEASUREMENTS: Chi-square test, Student t test, and Mann-Whitney U test were used to compare, respectively, proportions, means, and medians between the two groups. RESULTS AND LIMITATIONS: Patients in the AR-3D group had comparable preoperative characteristics and those undergoing the NS approach were referred to as the control group (all p ≥ 0.06). Overall, positive surgical margin (PSM) rates were comparable between the two groups; PSMs at the level of the index lesion were significantly lower in patients referred to AR-3D guided IFS to the index lesion (5%) than those in the control group (20%; p = 0.01). CONCLUSIONS: The novel technique of AR-3D guidance for IFS analysis may allow for reducing PSMs at the level of the index lesion. PATIENT SUMMARY: Augmented reality three-dimensional guidance for intraoperative frozen section analysis during robot-assisted radical prostatectomy facilitates the real-time assessment of surgical margins and may reduce positive surgical margins at the index lesion.


Assuntos
Realidade Aumentada , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Secções Congeladas , Humanos , Masculino , Margens de Excisão , Próstata , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos
6.
Clin Genitourin Cancer ; 18(6): e669-e678, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32354617

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the impact of 3-dimensional (3D) digital reconstructions of renal models on the arterial clamping approach during partial nephrectomy (PN). PATIENTS AND METHODS: Fifty-seven patients with T1 renal mass, referred for PN, were prospectively enrolled in 2 groups: Group 1 (n = 32) with revision of both 2-dimensional (2D) computed tomography (CT) imaging and 3D virtual model before surgery; Group 2 (n = 25) with revision of 2D CT imaging. Segmentation of the 3D models from preoperative high-quality CT scan was achieved using D2P software. In a sub-analysis of patients treated with PN with the on-clamp approach (n = 36), the effective intraoperative level of arterial clamping was compared with the preoperative planning. RESULTS: In the sub-group of patients referred to PN with the on-clamp approach, the intraoperative selective clamping was performed in 12 (57.1%) patients of Group 1 and in 2 (13.3%) cases of Group 2 (P = .01). The intraoperative management of the renal pedicle was done as preoperatively planned in 61.9% of patients in Group 1 and in 86.6% of cases in Group 2 (P = .1). CONCLUSION: The 3D-guided plan of PN allows to perform selective clamping in higher proportion of patients compared with the standard 2D-guided approach without increasing intraoperative and postoperative complications.


Assuntos
Neoplasias Renais , Estudos de Casos e Controles , Humanos , Imageamento Tridimensional , Rim/diagnóstico por imagem , Rim/cirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Nefrectomia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa