RESUMO
Background Optimal haemostasis management in orthotropic liver transplant (OLT) could reduce blood loss and transfusion volume, improve patient outcomes and reduce cost. Methods We performed a study including 336 OLTs to evaluate the clinical and cost effectiveness of a new point-of-care (POC)-based haemostatic management approach in OLT patients. Results In terms of health benefit we found that the new approach showed a significant reduction in transfusion requirements (red blood cell transfusion units were reduced from 5.3±4.6 to 2.8±2.9 [p<0.001], free frozen plasma from 3.1±3.3 to 0.4±1.0 [p<0.001] and platelets from 2.9±3.9 to 0.4±0.9 [p<0.001], transfusion avoidance, 9.7% vs. 29.1% [p<0.001] and massive transfusion, 14.5% vs. 3.8% [p=0.001]); we also found a significant improvement in patient outcomes, such, reoperation for bleeding or acute-kidney-failure (8.3% vs. 2.4%, p=0.015; 33.6% vs. 5.4%, p<0.001), with a significant reduction in the length of the hospital total stay (40.6±13.8 days vs. 38.2±14.4 days, p=0.001). The lowest cost incurred was observed with the new approach (73,038.80 vs. 158,912.90) with significant patient saving associated to transfusion avoidance (1278.36), ICU-stay (3037.26), total-stay (3800.76) and reoperation for bleeding (80,899.64). Conclusions POC haemostatic monitoring during OLT is cost effective.