Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
J Card Fail ; 27(3): 327-337, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33347997

RESUMO

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) is increasingly used as a life-saving therapy for patients with cardiovascular collapse, but identifying patients unlikely to benefit remains a challenge. METHODS AND RESULTS: We created the RESCUE registry, a retrospective, observational registry of adult patients treated with VA-ECMO between January 2007 and June 2017 at 3 high-volume centers (Columbia University, Duke University, and Washington University) to describe short-term patient outcomes. In 723 patients treated with VA-ECMO, the most common indications for deployment were postcardiotomy shock (31%), cardiomyopathy (including acute heart failure) (26%), and myocardial infarction (17%). Patients frequently suffered in-hospital complications, including acute renal dysfunction (45%), major bleeding (41%), and infection (33%). Only 40% of patients (n = 290) survived to discharge, with a minority receiving durable cardiac support (left ventricular assist device [n = 48] or heart transplantation [n = 7]). Multivariable regression analysis identified risk factors for mortality on ECMO as older age (odds ratio [OR], 1.26; 95% confidence interval [CI], 1.12-1.42) and female sex (OR, 1.44; 95% CI, 1.02-2.02) and risk factors for mortality after decannulation as higher body mass index (OR 1.17; 95% CI, 1.01-1.35) and major bleeding while on ECMO support (OR, 1.92; 95% CI, 1.23-2.99). CONCLUSIONS: Despite contemporary care at high-volume centers, patients treated with VA-ECMO continue to have significant in-hospital morbidity and mortality. The optimization of outcomes will require refinements in patient selection and improvement of care delivery.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Adulto , Idoso , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Humanos , Sistema de Registros , Estudos Retrospectivos , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia
2.
J Card Surg ; 36(4): 1219-1225, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33462900

RESUMO

BACKGROUND: Port-access (PORT) and robotic (ROBO) mitral repair are well established, but differences in patient selection and outcomes are not well documented. METHODS: A retrospective analysis was performed on 129 ROBO and 628 PORT mitral repairs at one institution. ROBO patients had 4 cm nonrib spreading incisions with robotic assistance, while PORT patients had 6-8 cm rib spreading incisions with thoracoscopic assistance. Propensity score analysis matched patients for differences in baseline characteristics. RESULTS: Unmatched ROBO patients were younger (58 ± 11 vs. 61 ± 13, p = .05), had a higher percentage of males (77% vs. 63%, p = .003) and had less NYHA Class 3-4 symptoms (11% vs. 21%, p < .01), less atrial fibrillation (19% vs. 29%, p = .02) and less tricuspid regurgitation (14% vs. 24%, p = .01). Propensity score analysis of matched patients showed that pump time (275 ± 57 vs. 207 ± 55, p < .0001) and clamp time (152 ± 38 vs. 130 ± 34, p < .0001) were longer for ROBO patients. However, length of stay, postoperative morbidity, and 5-year survival (97 ± 1% vs. 96 ± 3%, p = .7) were not different. For matched patients with degenerative valve disease, 5-year incidence of mitral reoperation (3 ± 2% vs. 1 ± 1%), severe mitral regurgitation (MR) (6 ± 4% vs. 1 ± 1%), or ≥2 + MR (12 ± 5% vs. 12 ± 4%), were not significantly different between ROBO versus PORT approaches. Predictors of recurrent moderate MR were connective tissue disease, functional etiology, and non-White race, but not surgical approach. CONCLUSIONS: In this first comparison out to 5 years, robotic versus port-access approach to mitral repair had longer pump and clamp times. Perioperative morbidity, 5-year survival, and 5-year repair durability were otherwise similar.


Assuntos
Insuficiência da Valva Mitral , Valva Mitral , Procedimentos Cirúrgicos Robóticos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento
3.
Am Heart J ; 222: 26-29, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32004797

RESUMO

Atrial arrhythmias commonly occur in patients with cardiac amyloidosis (CA), but there is limited data on safety or efficacy of cardioversion (DCCV) for management of these rhythms in CA. We identified 25 patients with CA (20 with transthyretin (TTR) and 5 with light-chain (AL) amyloidosis) at Duke University who underwent DCCV for atrial arrhythmias and documented procedural success, complications, and long-term morbidity and mortality. While DCCV successfully restored sinus rhythm in 96% of patients, 36% of patients experienced immediate procedural complications (primarily bradycardia and hypotension), 80% had recurrence of atrial arrhythmias at 1 year, and 52% died at 3 years, highlighting short-term safety concerns, long-term inefficacy, and poor prognosis associated with symptomatic atrial arrhythmias requiring DCCV in CA.


Assuntos
Amiloidose/complicações , Fibrilação Atrial/terapia , Flutter Atrial/terapia , Cardiomiopatias/complicações , Cardioversão Elétrica/métodos , Idoso , Amiloidose/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Flutter Atrial/epidemiologia , Flutter Atrial/etiologia , Biópsia , Cardiomiopatias/diagnóstico , Causas de Morte/tendências , Feminino , Seguimentos , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Morbidade/tendências , Miocárdio/patologia , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
4.
Am Heart J ; 225: 3-9, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32417526

RESUMO

The infection caused by severe acute respiratory syndrome coronavirus-2, or COVID-19, can result in myocardial injury, heart failure, and arrhythmias. In addition to the viral infection itself, investigational therapies for the infection can interact with the cardiovascular system. As cardiologists and cardiovascular service lines will be heavily involved in the care of patients with COVID-19, our division organized an approach to manage these complications, attempting to balance resource utilization and risk to personnel with optimal cardiovascular care. The model presented can provide a framework for other institutions to organize their own approaches and can be adapted to local constraints, resource availability, and emerging knowledge.


Assuntos
Arritmias Cardíacas , Infecções por Coronavirus , Procedimentos Clínicos , Cardiopatias , Insuficiência Cardíaca , Controle de Infecções , Pandemias , Pneumonia Viral , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/complicações , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/fisiopatologia , Infecções por Coronavirus/terapia , Procedimentos Clínicos/organização & administração , Procedimentos Clínicos/normas , Prática Clínica Baseada em Evidências/tendências , Cardiopatias/diagnóstico , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Cardiopatias/virologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Administração dos Cuidados ao Paciente/métodos , Pneumonia Viral/complicações , Pneumonia Viral/epidemiologia , Pneumonia Viral/fisiopatologia , Pneumonia Viral/terapia , SARS-CoV-2 , Estados Unidos
5.
J Cardiovasc Electrophysiol ; 31(6): 1509-1518, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32275340

RESUMO

INTRODUCTION: Lead dysfunction can lead to serious consequences including failure to treat ventricular tachycardia or fibrillation (VT/VF). The incidence and mechanisms of lead dysfunction following left ventricular assist device (LVAD) implantation are not well-described. We sought to determine the incidence, mechanisms, timing, and complications of right ventricular lead dysfunction requiring revision following LVAD implantation. METHODS: Retrospective observational chart review of all LVAD recipients with pre-existing implantable cardioverter-defibrillator (ICD) from 2009 to 2018 was performed including device interrogation reports, laboratory and imaging data, procedural reports, and clinical outcomes. RESULTS: Among 583 patients with an ICD in situ undergoing LVAD implant, the median (interquartile range) age was 62.5 (15.7) years, 21% were female, and the types of LVADs included HeartWare HVAD (26%), HeartMate II (52%), and HeartMate III (22%). Right ventricular lead revision was performed in 38 patients (6.5%) at a median (25th, 75th) of 16.4 (3.6, 29.2) months following LVAD. Mechanisms of lead dysfunction included macrodislodgement (n = 4), surgical lead injury (n = 4), recall (n = 3), insulation failure (n = 8) or conductor fracture (n = 7), and alterations in the lead-myocardial interface (n = 12). Undersensing requiring revision occurred in 22 (58%) cases. Clinical sequelae of undersensing included failure to detect VT/VF (n = 4) and pacing-induced torsade de pointes (n = 1). Oversensing occurred in 12 (32%) and sequelae included inappropriate antitachycardia pacing ([ATP], n = 8), inappropriate ICD shock (n = 6), and ATP-induced VT (n = 1). CONCLUSION: The incidence of right ventricular lead dysfunction following LVAD implantation is significant and has important clinical sequelae. Physicians should remain vigilant for lead dysfunction after LVAD surgery and test lead function before discharge.


Assuntos
Arritmias Cardíacas/terapia , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese/instrumentação , Função Ventricular Esquerda , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Implantação de Prótese/efeitos adversos , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 43(9): 913-921, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32573789

RESUMO

BACKGROUND: Cardiac amyloidosis is a progressive infiltrative disease involving deposition of amyloid fibrils in the myocardium and cardiac conduction system that frequently manifests with heart failure (HF) and arrhythmias, most frequently atrial fibrillation (AF), atrial flutter (AFL), and atrial tachycardia (AT). METHODS: We performed an observational retrospective study of patients with a diagnosis of cardiac amyloid who underwent catheter ablation at our institution between January 1, 2011 and December 1, 2018. Patient demographics, procedural characteristics, and outcomes were determined by manual chart review. RESULTS: A total of 13 catheter ablations were performed over the study period in patients with cardiac amyloidosis, including 10 AT/AF/AFL ablations and three atrioventricular nodal ablations. Left ventricular ejection fraction was lower at the time of AV node ablation than catheter ablation of AT/AF/AFL (23% vs 40%, P = .003). Cardiac amyloid was diagnosed based on the results of preablation cardiac MRI results in the majority of patients (n = 7, 70%). The HV interval was prolonged at 60 ± 15 ms and did not differ significantly between AV nodal ablation patients and AT/AF/AFL ablation patients (69 ± 18 ms vs 57 ± 14 ms, P = .36). The majority of patients undergoing AT/AF/AFL ablation had persistent AF (n = 7, 70%) and NYHA class II (n = 5, 50%) or III (n = 5, 50%) HF symptoms, whereas patients undergoing AV node ablation were more likely to have class IV HF (n = 2, 66%, P = .014). Arrhythmia-free survival in CA patients after catheter ablation of AT/AF/AFL was 40% at 1 year and 20% at 2 years. CONCLUSIONS: Catheter ablation of AT/AF/AFL may be a feasible strategy for appropriately selected patients with early to mid-stage CA, whereas AV node ablation may be more appropriate in patients with advanced-stage CA.


Assuntos
Amiloidose/cirurgia , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos , Idoso , Amiloidose/complicações , Cardiomiopatias/complicações , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Recidiva , Estudos Retrospectivos
7.
Am Heart J ; 204: 163-173, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30121018

RESUMO

INTRODUCTION: Worsening renal function (WRF) can occur throughout a hospitalization for acute heart failure (HF). However, decongestion can be measured in different ways and the prognostic implications of WRF in the setting of different measures of decongestion are unclear. METHODS: Patients (N = 433) from the ESCAPE were classified by measures of decongestion during hospitalization: hemodynamic (right atrial pressure ≤8 mmHg and/or wedge pressure ≤15 mmHg at discharge), clinical (≤1 sign of congestion at discharge), hemoconcentration (any increase in hemoglobin) and estimated plasma volume using the Hakim formula (5% reduction in plasma volume). WRF was defined as creatinine increase ≥0.3 mg/dl during hospitalization. The association between WRF and 180-day all-cause death was assessed. RESULTS: Successful decongestion was observed in 124 (60%) patients by hemodynamics, 204 (49%) by clinical exam, 173 (47%) by hemoconcentration, and 165 (45%) by plasma volume. There was no agreement between the hemodynamic assessment and other decongestion measures in up to 43% of cases. Persistent congestion with concomitant WRF at discharge was associated with worse outcomes compared to patients without congestion and WRF. Among patients decongested at discharge, in-hospital WRF was not significantly associated with 180-day all-cause death, when using hemodynamic, clinical or estimated plasma volume as measures of decongestion (P > .05 for all markers). CONCLUSIONS: In patients hospitalized for HF, although there was disagreement across common measures of decongestion, in-hospital WRF was not associated with increased hazard of all-cause mortality among patients successfully decongested at discharge.


Assuntos
Cateterismo de Swan-Ganz , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Hemodinâmica , Rim/fisiopatologia , Monitorização Fisiológica/métodos , Idoso , Creatinina/sangue , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Hemoglobinas/metabolismo , Hospitalização , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Volume Plasmático , Insuficiência Renal/etiologia , Resultado do Tratamento
8.
J Robot Surg ; 16(1): 199-206, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33761097

RESUMO

The literature for robotic mitral repair is dominated by a small number of large volume institutions, and intermediate-term outcomes out to 5 years are rare. Whether and under what circumstances a lower volume institution could obtain durable outcomes is not known. A retrospective review was performed on all 133 patients undergoing robotically assisted mitral repair from 2011 to 2019 at a single institution. Mean volume of robotic mitral repair was 16 ± 7 cases per year, while mean institutional total volume of mitral repair was 116 ± 16 cases per year. Mean age was 58 ± 12 years, 77% were men, and mitral etiology was prolapse in 90%. Comorbidity was infrequent with atrial fibrillation in 20% and moderate tricuspid regurgitation in 14%. Central aortic cannulation was used in 97% with concurrent tricuspid operation in 5% and concurrent maze in 14%. Median clamp time, pump time, and length of stay were 146 min, 265 min, and 5 days, respectively, but none improved with experience. There were no deaths or stroke. At 5 years, the cumulative incidence of moderate mitral regurgitation was 18 ± 6% (prolapse patients 11 ± 5%), severe regurgitation 4 ± 3%, and mitral replacement 9 ± 5% (prolapse patients 5 ± 3%). 5-year survival was 96 ± 3%. At centers with significant mitral repair volume, a volume of 16 robotic mitral cases/year can yield good clinical outcomes durable out to 5 years. A case volume of 16 cases per year was not sufficient to improve pump time or length of stay over time.


Assuntos
Insuficiência da Valva Mitral , Procedimentos Cirúrgicos Robóticos , Robótica , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento
9.
JACC Heart Fail ; 10(2): 129-138, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35115086

RESUMO

OBJECTIVES: This study evaluated the association of transthyretin (TTR) gene variant, in which isoleucine substitutes for valine at position 122 (V142I), with cardiac structure, function, and heart failure (HF) risk among middle-aged Black adults. BACKGROUND: The valine-to-isoleucine substitution in the TTR protein is prevalent in Black individuals and causes cardiac amyloidosis. METHODS: Jackson Heart Study participants without HF at baseline who had available data on the TTR V142I variant were included. The association of the TTR V142I variant with baseline echocardiographic parameters and repeated measures of high-sensitivity cardiac troponin-I (hs-cTnI) was assessed using adjusted linear regression models and linear mixed models, respectively. Adjusted Cox models, restricted mean survival time analysis, and Anderson-Gill models were constructed to determine the association of TTR V142I variant with the risk of incident HF, survival free of HF, and total HF hospitalizations. RESULTS: A total of 119 of 2,960 participants (4%) were heterozygous carriers of the TTR V142I variant. The TTR V142I variant was not associated with measures of cardiac parameters at baseline but was associated with a greater increase in high-sensitivity troponin I (hs-TnI) levels over time. In adjusted Cox models, TTR V142I variant carriers had significantly higher risk of incident HF (HR: 1.80; 95% CI: 1.07-3.05; P = 0.03), lower survival free of HF (mean difference: 4.0 year; 95% CI: 0.6-6.2 years); P = 0.02), and higher risk of overall HF hospitalizations (HR: 2.12; 95% CI: 1.23-3.63; P = 0.007). CONCLUSIONS: The TTR V142I variant in middle-aged Black adults is not associated with adverse cardiac remodeling but was associated with a significantly higher burden of chronic myocardial injury, and greater risk of incident HF and overall HF hospitalizations.


Assuntos
Insuficiência Cardíaca , Pré-Albumina , Adulto , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/genética , Humanos , Isoleucina , Pessoa de Meia-Idade , Pré-Albumina/genética , Troponina I , Valina , Remodelação Ventricular/genética
10.
Heart Rhythm ; 18(8): 1263-1271, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33839327

RESUMO

BACKGROUND: Ventricular arrhythmias (VAs) and electrical storm (ES) are recognized complications following left ventricular assist device (LVAD) implantation; however, their association with long term-outcomes remains poorly understood. OBJECTIVE: The purpose of this study was to describe the clinical impact of ES in a population of patients undergoing LVAD implantation at a quaternary care center in the United States. METHODS: This was an observational retrospective study of patients undergoing LVAD implantation from 2009 to 2020 at Duke University Hospital. The incidence of ES (≥3 sustained VA episodes over a 24-hour period without an identifiable reversible cause) was determined from patient records. Risk factors for ES were identified using multivariable Cox proportional hazards modeling. RESULTS: Among 730 patients undergoing LVAD implant, 78 (10.7%) developed ES at a median of 269 (interquartile range [IQR] 7-766) days following surgery. Twenty-seven patients (34.6%) developed ES within 30 days, while 51 (65.4%) presented with ES at a median 639 (IQR 281-1017) days after implant. Following ES, 41% of patients died within 1 year. Patients who developed ES were more likely to have a history of VAs, ventricular tachycardia ablation, antiarrhythmic drug use, and perioperative mechanical circulatory support around the time of LVAD implant than patients without ES. CONCLUSION: ES occurs in 1 in 10 patients after LVAD and is associated with higher mortality. Risk factors for ES include a history of VAs, VT ablation, antiarrhythmic drug use, and perioperative mechanical circulatory support. Optimal management of ES surrounding LVAD implant, including escalation of medical therapy, catheter ablation, or adjunctive sympatholytic therapies, remains uncertain.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Idoso , Falha de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Ventrículos do Coração/fisiopatologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Taquicardia Ventricular/epidemiologia , Fatores de Tempo , Estados Unidos/epidemiologia
11.
JACC Clin Electrophysiol ; 6(9): 1144-1154, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32972550

RESUMO

OBJECTIVES: This study characterized the relationship between conduction disease and cardiac amyloidosis (CA) through longitudinal analysis of cardiac implantable electronic device (CIED) data. BACKGROUND: Bradyarrhythmias and tachyarrhythmias are commonly reported in CA and may precede a CA diagnosis, although the natural history of conduction disease in CA is not well-described. METHODS: Patients with CA (transthyretin amyloidosis cardiomyopathy [ATTR-CM] and light-chain amyloidosis [AL-CA]) and a CIED were identified within the Duke University Health System. Patient characteristics at the time of implantation, including demographics and data relevant to CA diagnosis, cardiac imaging, and CIED were recorded. CIED interrogations were analyzed for pacing and atrial fibrillation (AF) burden, activity level, lead parameters, and ventricular arrhythmia incidence and/or therapy. RESULTS: Thirty-four patients with CA (7 with AL-CA, 27 with ATTR-CM [78% with wild-type]; 82% men) with median age of 75 years and a mean ejection fraction of 42 ± 13% had a CIED implanted for bradycardia (65%) or prevention of sudden cardiac death (35%). CIED implantation preceded CA diagnosis in 14 patients (41%). Over a mean follow-up of 3.1 ± 4.0 years, right ventricular sensing amplitudes decreased but did not result in device malfunction; lead impedances and capture thresholds remained stable. Between post-implantation years 1 and 5, mean ventricular pacing increased from 56 ± 9% to 96 ± 1% (p = 0.003) and AF burden increased from 2 ± 1.3 to 17 ± 3 h/day (p = 0.0002). Ventricular arrhythmias were common (mean episodes per patient per year: 6.7 ± 2.3 [ATTR-CM] and 5.1 ± 3.2 [AL-CA]) but predominately nonsustained; only 1 patient with AL-CA required implantable cardioverter-defibrillator therapy. CONCLUSIONS: Longitudinal analysis of CIED data in patients with CA revealed progressive conduction disease, with high AF burden and eventual dependence on ventricular pacing, although lead parameters remained stable. Ventricular arrhythmias were common but predominantly nonsustained, particularly in ATTR-CM.


Assuntos
Neuropatias Amiloides Familiares , Desfibriladores Implantáveis , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Doença do Sistema de Condução Cardíaco , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Feminino , Humanos , Masculino
12.
JACC Case Rep ; 2(11): 1662-1666, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34317029

RESUMO

A 69-year-old man with a history of coronary artery ectasia, potentially resulting from an underlying heritable connective tissue disorder, presented with ventricular fibrillation. Despite medical management of ischemia, he developed recurrent ventricular tachycardia with poor neurological recovery. We highlight challenges in the management of coronary artery ectasia. (Level of Difficulty: Beginner.).

13.
Circ Heart Fail ; 13(7): e006840, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32660322

RESUMO

Biomarkers have a well-defined role in the diagnosis and management of chronic heart failure, but their role in patients with left ventricular assist devices and cardiac transplant is uncertain. In this review, we summarize the available literature in this patient population, with a focus on clinical application. Some ubiquitous biomarkers, for example, natriuretic peptides and cardiac troponin, may assist in the diagnosis of left ventricular assist device complications and transplant rejection. Novel biomarkers focused on specific pathological processes, such as left ventricular assist device thrombosis and profiling of leukocyte activation, continue to be developed and show promise in altering the management of the advanced heart failure patient. Few biomarkers at this time have been assessed with sufficient scrutiny to warrant broad, universal application, but encouraging limited data and large potential for impact should prompt ongoing investigation.


Assuntos
Biomarcadores/sangue , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/terapia , Doença Crônica , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Implantação de Prótese/efeitos adversos
14.
JACC Clin Electrophysiol ; 6(9): 1131-1139, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32972548

RESUMO

OBJECTIVES: This study sought to determine the indications, characteristics, and outcomes of cardiovascular implantable electronic device (CIED) surgery in patients with LVAD. BACKGROUND: Many patients with a left ventricular assist device (LVAD) will require implantable cardioverter-defibrillator generator change or device revision or are candidates for de novo implantable cardioverter-defibrillator implantation following LVAD implantation. METHODS: We performed an observational retrospective study of all LVAD recipients who subsequently underwent CIED surgery at Duke University Hospital from 2009 to 2019. RESULTS: A total of 159 patients underwent CIED surgery following LVAD implantation, including generator change (n = 93), device revision (n = 38), and de novo implant (n = 28). The median (interquartile range) time from LVAD implantation to CIED surgery was 18.1 months (5.5 to 35.1 months). Pre-operative risk for infection was elevated in the overall cohort with a median (interquartile range) Prevention of Arrhythmia Device Infection Trial (PADIT) score of 7.0 (5.0 to 9.0). Pocket hematoma occurred in 21 patients (13.2%) following CIED surgery. Antimicrobial envelops were used in 43 patients (27%). Device infection due to CIED surgery occurred in 5 (3.1%) patients and occurred only in patients who developed post-operative pocket hematoma (p < 0.001). Mortality at 1 year following CIED surgery was 20% (n = 32). CONCLUSIONS: CIED surgery following LVAD implantation is associated with an increased risk for pocket hematoma and CIED infection. Further studies are needed to determine the risk-benefit ratio of CIED surgery in patients with LVADs.


Assuntos
Desfibriladores Implantáveis , Coração Auxiliar , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos
15.
JACC Heart Fail ; 8(12): 999-1008, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33189635

RESUMO

OBJECTIVES: This study sought to better understand the discrepant results of 2 trials of serelaxin on acute heart failure (AHF) and short-term mortality after AHF by analyzing causes of death of patients in the RELAX-AHF-2 (Efficacy, Safety and Tolerability of Serelaxin When Added to Standard Therapy in AHF-2) trial. BACKGROUND: Patients with AHF continue to suffer significant short-term mortality, but limited systematic analyses of causes of death in this patient population are available. METHODS: Adjudicated cause of death of patients in RELAX-AHF-2, a randomized, double-blind, placebo-controlled trial of serelaxin in patients with AHF across the spectrum of ejection fraction (EF), was analyzed. RESULTS: By 180 days of follow-up, 11.5% of patients in RELAX-AHF-2 died, primarily due to heart failure (HF) (38% of all deaths). Unlike RELAX-AHF, there was no apparent effect of treatment with serelaxin on any category of cause of death. Older patients (≥75 years) had higher rates of mortality (14.2% vs. 8.8%) and noncardiovascular (CV) death (27% vs. 19%) compared to younger patients. Patients with preserved EF (≥50%) had lower rates of HF-related mortality (30% vs. 40%) but higher non-CV mortality (36% vs. 20%) compared to patients with reduced EF. CONCLUSIONS: Despite previous data suggesting benefit of serelaxin in AHF, treatment with serelaxin was not found to improve overall mortality or have an effect on any category of cause of death in RELAX-AHF-2. Careful adjudication of events in the serelaxin trials showed that older patients and those with preserved EF had fewer deaths from HF or sudden death and more deaths from other CV causes and from noncardiac causes. (Efficacy, Safety and Tolerability of Serelaxin When Added to Standard Therapy in AHF [RELAX-AHF-2]; NCT01870778).


Assuntos
Insuficiência Cardíaca , Relaxina , Doença Aguda , Causas de Morte , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Proteínas Recombinantes , Resultado do Tratamento
16.
Macromol Rapid Commun ; 30(16): 1399-405, 2009 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-21638397

RESUMO

A sterically encumbered m-terphenyl oxacyclophane substituted with two aryl iodide substituents has been prepared as a versatile monomer for the preparation of π-conjugated polymers. The monomer has been used to prepare a poly(p-phenylene ethynylene) derivative (P1) incorporating oxacyclophane units as canopies that shield one side of the π-system from inter-chain interactions. The photophysical properties of P1 in dilute solution compare well to those of a poly(p-phenylene ethynylene) derivative (P2) that lacks the canopy. The presence of the steric canopy leads to a diminished inter-chain interaction in the solid state and enhances the kinetic response of P1 to vapors of nitro-organics such as TNT, presumably by increasing the permeability of P1 to these analytes over that of P2.

17.
JACC CardioOncol ; 1(2): 273-279, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34396189

RESUMO

Transthyretin amyloid cardiomyopathy (ATTR-CM) has emerged as an increasingly identified etiology of heart failure. Fortunately, the disease now has an approved therapy, with many others under development. Assessment of prognosis in ATTR-CM is critical to inform patients about the disease course and guide clinical decisions. This review discusses the evidence behind clinical, biomarker, and imaging findings that inform prognosis in patients with ATTR-CM and can assist providers in the shared decision-making process during management of this disease.

18.
J Heart Lung Transplant ; 35(7): 868-76, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27041496

RESUMO

BACKGROUND: Right ventricular (RV) failure is a source of morbidity and mortality after left ventricular assist device (LVAD) implantation. In this study we sought to define hemodynamic changes in afterload and RV adaptation to afterload both early after implantation and with prolonged LVAD support. METHODS: We reviewed right heart catheterization (RHC) data from participants who underwent continuous-flow LVAD implantation at our institutions (n = 244), excluding those on inotropic or vasopressor agents, pulmonary vasodilators or additional mechanical support at any RHC assessment. Hemodynamic data were assessed at 5 time intervals: (1) pre-LVAD (within 6 months); (2) early post-LVAD (0 to 6 months); (3) 7 to 12 months; (4) 13 to 18 months; and (5) very late post-LVAD (18 to 36 months). RESULTS: Sixty participants met the inclusion criteria. All measures of right ventricular load (effective arterial elastance, pulmonary vascular compliance and pulmonary vascular resistance) improved between the pre- and early post-LVAD time periods. Despite decreasing load and pulmonary artery wedge pressure (PAWP), RAP remained unchanged and the RAP:PAWP ratio worsened early post-LVAD (0.44 [0.38, 0.63] vs 0.77 [0.59, 1.0], p < 0.001), suggesting a worsening of RV adaptation to load. With continued LVAD support, both RV load and RAP:PAWP decreased in a steep, linear and dependent manner. CONCLUSIONS: Despite reducing RV load, LVAD implantation leads to worsened RV adaptation. With continued LVAD support, both RV afterload and RV adaptation improve, and their relationship remains constant over time post-LVAD. These findings suggest the RV afterload sensitivity increases after LVAD implantation, which has major clinical implications for patients struggling with RV failure.


Assuntos
Disfunção Ventricular Direita , Insuficiência Cardíaca , Coração Auxiliar , Hemodinâmica , Humanos , Estudos Retrospectivos
20.
J Plast Reconstr Aesthet Surg ; 67(1): e22-4, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23972536

RESUMO

We present a case study of a patient with a rare and disfiguring dermatologic condition known as cornu cutaneum, or giant cutaneous horn (GCH). While this condition has been well described in people of European and Asian ancestry, its presence in African populations is perceived to be rare and has not been reported in the literature until recently. We present the case of cornu cutaneum in a woman of African descent, contributing to the recent evidence that this condition may not be as rare in African populations as believed. Etiologic factors, epidemiology and management are also reviewed.


Assuntos
Couro Cabeludo/patologia , Dermatopatias/patologia , Negro ou Afro-Americano , Feminino , Humanos , Pessoa de Meia-Idade , Dermatopatias/complicações , Dermatopatias/etnologia , Dermatopatias/cirurgia , Transplante de Pele , Verrugas/complicações
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa