Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Exp Physiol ; 104(5): 643-653, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30821049

RESUMO

NEW FINDINGS: What is the central question of this study? Visceral ischaemia is one of the most feared complications during use of an intra-aortic balloon pump. Using an animal model, we measured the flows at the abdominal level directly and examined flow patterns to enable investigation of flow patterns during the use of the intra-aortic balloon pump. What is the main finding and its importance? We show that there is a significant balloon-related reduction in superior mesenteric flow in both early and mid-diastole. ABSTRACT: A number of previous studies have shown that blood flow in the visceral arteries is altered during intra-aortic balloon pump (IABP) treatment. We used a porcine model to analyse the pattern of blood flow into the visceral arteries during IABP use. For this purpose, we measured the superior mesenteric, right renal and left renal flows before and during IABP support, using surgically placed flowmeters surrounding these visceral arteries. The superior mesenteric flow significantly decreased in early diastole (P < 0.001) and in mid-diastole (P = 0.003 versus early diastole), whereas in late diastole it increased again (P < 0.001 versus mid-diastole). During systole, the flow was not significantly increased compared with late diastole (P = 0.51), but it was significantly lower than at baseline (both P < 0.001). Flows did not differ between right and left kidneys. Perfusion of either kidney did not change significantly in early diastole (P > 0.05), whereas it decreased significantly in mid-diastole (P < 0.001), rising dramatically in late diastole (P < 0.001) and with an additional slight increase in systole (P = 0.054). This study provides important insights into abdominal flows during intra-aortic pump counterpulsation. Furthermore, it supports the need to rethink the balloon design to avoid visceral ischaemia during circulatory assistance.


Assuntos
Balão Intra-Aórtico , Artéria Mesentérica Superior/fisiologia , Circulação Renal/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Contrapulsação , Diástole/fisiologia , Eletrocardiografia , Hemodinâmica , Monitorização Fisiológica , Reologia , Suínos , Sístole/fisiologia
2.
Perfusion ; 33(2): 96-104, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28816093

RESUMO

BACKGROUND: The use of the intra-aortic balloon pump (IABP) as a support device remains controversial due to the fact that a number of studies have shown no benefit in end mortality whilst using this device. One of the reasons for this could be the increase in vascular complications when using the pump. Therefore, the aim of the present review was to assess the current literature available with regards to IABP vascular complications during the clinical situation. METHODS: A literature search was performed, searching for IABP complications in adult human studies between 1990 and 2016. RESULTS: A total of 20 reports were identified as fitting the criteria of this study. The majority of vascular complications were limb ischemia, bleeding or mesenteric ischemia. The overall incidence of vascular complications ranged from 0.94% to 31.1%. Diabetes, peripheral vascular disease and hypertension, as well as smoking were all identified as risk factors for complications following IABP. Furthermore, studies supported the use of sheathless balloon insertion to reduce the risk of complications. CONCLUSION: Major vascular complications, including limb and mesenteric ischemia as well as bleeding and hemorrhage, have been associated with IABP. However, the incidence of these complications was generally low. Further studies are still required to truly understand the risk/benefit associated with the use of IABP.


Assuntos
Doenças Cardiovasculares/etiologia , Coração Auxiliar/efeitos adversos , Hemorragia/etiologia , Balão Intra-Aórtico/instrumentação , Doenças Cardiovasculares/patologia , Feminino , Hemorragia/patologia , Humanos , Masculino , Medição de Risco , Fatores de Risco
3.
Perfusion ; 32(4): 285-295, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27864477

RESUMO

AIM: We evaluated the influence of intra-aortic balloon size and volume on mesenteric and renal flows. METHODS: Thirty healthy swine underwent 120-minute ligation of the left anterior descending coronary artery followed by 6 hours of reperfusion. Then, they were randomly assigned to the following five groups of animals, with six animals in each group: no intra-aortic balloon pump (IABP), a short 35-mL IABP, a short 40-mL IABP, a long 35-mL IABP and a long 40-mL IABP. Superior mesenteric artery (SMA) and renal flows were measured at baseline (t0), at 2-hour ischemia (t1) and every hour thereafter until 6 hours of reperfusion (from tR1 to tR6). RESULTS: SMA flows increased significantly at tR1 only in the two short IABP groups (p<0.001) and balloon volume did not appear to affect flows which, at any experimental time-point, were comparable using 35 mL or 40 mL balloons (p>0.05). Renal flows appeared to be influenced by balloon length, but not by volume. Indeed, flows in the renal arteries rose during IABP treatment; the increase was significantly higher in the short balloon groups and throughout the whole reperfusion (all, p<0.001). CONCLUSIONS: Changes in visceral perfusion during IABP assistance were significantly related to balloon length, but not to its volume. This could be relevant for the evolution of balloon engineering design in order to reduce the incidence of mesenteric ischemia following IABP. Further research is necessary to confirm these findings.


Assuntos
Balão Intra-Aórtico/métodos , Artéria Mesentérica Superior/fisiologia , Circulação Renal/fisiologia , Animais , Velocidade do Fluxo Sanguíneo , Modelos Animais de Doenças , Distribuição Aleatória , Suínos
4.
Europace ; 18(10): 1528-1537, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26721977

RESUMO

AIMS: To assess the results and impact of lesion set and surgical technique on long-term success of surgical ablation during mitral surgery. METHODS AND RESULTS: The patient population consisted of 685 subjects with persistent and long-standing persistent atrial fibrillation (AF) undergoing cardiac surgery for mitral valve disease as the primary indication and concomitant ablation between January 2003 and January 2012 at three institutions. One hundred and sixty-six underwent unipolar (24.2%), 371 (54.2%) bipolar, and 148 (21.6%) had combined ablation. Median follow-up was 58.4 months (interquartile range 43.3-67.9). To appropriately account for death, a competing risk model was employed to identify predictors of cumulative incidence of recurrent AF among lesion set and surgical techniques. Eight-year freedom from recurrent arrhythmia without antiarrhythmic drugs was 0.60 ± 0.02. Success rate was higher using bipolar radiofrequency (RF) (P < 0.001), after performing mitral isthmus line (P = 0.003) and following the biatrial technique (P < 0.001). Competing risk regression revealed that use of unipolar RF [sub-hazard ratio (SHR) 2.41 (1.52-3.43), P < 0.001], combined unipolar/bipolar ablation [SHR 1.93 (0.89-2.57), P = 0.003] and the absence of right atrial ablation [SHR 2.79 (1.27-3.48), P < 0.001] were predictors of cumulative incidence of long-term recurrence. CONCLUSIONS: Our experience suggests that the use of bipolar clamp improves long-term results in surgical treatment of AF and that right-sided ablation should be routinely added. Randomized studies are necessary to confirm our findings.


Assuntos
Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/cirurgia , Idoso , Feminino , Seguimentos , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Países Baixos , Complicações Pós-Operatórias/mortalidade , Recidiva , Análise de Regressão , Estudos Retrospectivos , Resultado do Tratamento
5.
J Cardiothorac Surg ; 19(1): 387, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38926766

RESUMO

BACKGROUND: Multiportal video-assisted thoracic surgery (mVATS) is the standard approach for the surgical treatment of spontaneous pneumothorax. However, uniportal VATS (uVATS) has emerged as an alternative aiming to minimize surgical morbidity. This study aims to strengthen the evidence on the safety and efficiency of uVATS compared to mVATS. METHODS: From January 2004 to December 2020, records of patients who had undergone surgical treatment for primary or secondary spontaneous pneumothorax were evaluated for eligibility. Patients who had undergone pleurectomy combined with bullectomy or apical wedge resection via uVATS or mVATS were included. Surgical characteristics and postoperative data were compared between patients who had undergone surgery via uVATS or mVATS. Univariable and multivariable analyses were performed to determine whether the surgical approach was associated with any complication (primary outcome), major complications (i.e., Clavien-Dindo ≥ 3), recurrence, prolonged hospitalization or prolonged chest drainage duration (secondary outcomes). RESULTS: A total of 212 patients were enrolled. Patients treated via uVATS (n = 71) and mVATS (n = 141) were significantly different in pneumothorax type (secondary spontaneous; uVATS: 54 [76%], mVATS: 79 [56%]; p = 0.004). No significant differences were observed in (major) complications and recurrence rates between both groups. Multivariable analyses revealed that the surgical approach was no significant predictor for the primary or secondary outcomes. CONCLUSIONS: This study indicates that uVATS is non-inferior to mVATS in the surgical treatment of spontaneous pneumothorax regarding safety and efficiency, and thus the uVATS approach has the potential for further improvements in the perioperative surgical care for spontaneous pneumothorax.


Assuntos
Pneumotórax , Cirurgia Torácica Vídeoassistida , Humanos , Pneumotórax/cirurgia , Cirurgia Torácica Vídeoassistida/métodos , Masculino , Feminino , Adulto , Estudos Retrospectivos , Resultado do Tratamento , Complicações Pós-Operatórias , Pessoa de Meia-Idade
7.
BMJ Case Rep ; 14(7)2021 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-34315735

RESUMO

Triceps tendon rupture is rare and easily missed on presentation. A 58-year-old man was seen in our accident and emergency department with an inability to extend his right elbow against gravity after he fell. Ultrasound and MRI confirmed the suspected diagnosis of a traumatic triceps tendon rupture and excluded additional injuries. Surgical repair was carried out by a bone anchor suture reinsertion of the tendon to the olecranon. After 2 weeks of cast immobilisation, an early active range of motion (ROM) rehabilitation schedule was followed, resulting in excellent elbow function at 12 weeks postoperatively.In conclusion, it is important to suspect this rare injury and use additional studies to confirm the diagnosis of triceps tendon rupture. Also, good clinical outcome with regards to function can be achieved using bone anchor suture repair and an early active ROM rehabilitation schedule.


Assuntos
Olécrano , Traumatismos dos Tendões , Humanos , Masculino , Pessoa de Meia-Idade , Ruptura/cirurgia , Âncoras de Sutura , Técnicas de Sutura , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/cirurgia , Tendões
8.
Transl Lung Cancer Res ; 10(8): 3645-3658, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34584863

RESUMO

BACKGROUND: The current preferred approach for surgical mediastinal staging of non-small-cell lung carcinoma is video-assisted mediastinoscopy. An alternative technique in which lymph nodes are resected instead of biopsied is video-assisted mediastinoscopic lymphadenectomy (VAMLA) that is suggested to be superior in detecting N2 disease. Yet, evidence is conflicting and furthermore limited by sample size. The objective was to compare mediastinal staging through VAMLA and video-assisted mediastinoscopy. METHODS: A single-center cohort study was conducted. All consecutive patients that underwent surgical mediastinal staging of non-small-cell lung carcinoma by VAMLA (2011 to 2018) were compared to historic video-assisted mediastinoscopy controls (2007 to 2011). Patients with negative surgical mediastinal staging underwent subsequent anatomical resection with systematic regional lymphadenectomy. Primary outcome was the sensitivity and negative predictive value for detecting N2 disease. RESULTS: Two-hundred-sixty-nine video-assisted mediastinoscopic lymphadenectomies and 118 video-assisted mediastinoscopies were performed. The prevalence of N2 disease was 20% and 26% respectively in the VAMLA and video-assisted mediastinoscopy group, while the rate of unforeseen pN2 resulting from lymph node dissection during anatomical resection was 4% and 11%, respectively. Invasive staging using VAMLA demonstrated superior sensitivity of 0.82 and a negative predictive value of 0.96 when compared to video-assisted mediastinoscopy (0.62 and 0.89, respectively), offering a 64% decrease in risk of unforeseen pN2 following anatomical resection. However, VAMLA is also associated with a 75% risk increase on complications (P=0.36). CONCLUSIONS: We conclude that performing invasive mediastinal lymph node assessment for staging of non-small-cell lung carcinoma, VAMLA should be the preferred technique with superior sensitivity and negative predictive value in detecting N2 disease. Though, VAMLA is also associated with an increased risk of complications.

9.
Interact Cardiovasc Thorac Surg ; 31(4): 527-535, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33091932

RESUMO

OBJECTIVES: The objective of this study was to define the learning process of video-assisted mediastinoscopic lymphadenectomy (VAMLA) by the assessment of consecutive procedural metrics. METHODS: We conducted a single-centre retrospective observational study of all consecutive VAMLAs performed between 2011 and 2018 for the staging of non-small-cell lung carcinoma. Learning curves were assessed using non-risk adjusted cumulative observed minus expected (CUSUM) failure charts of complications. Boundary lines were defined by the acceptable and unacceptable complication rates of 4.5% and 15.0%. The Kruskal-Wallis test with post hoc analysis was used to assess trends in operation time and blood loss. RESULTS: Two-hundred-thirty-six unique VAMLAs by 4 surgeons performing their first procedures were evaluated. CUSUM charts of surgeons A and B showed a typical learning curve with an initial incline, followed by a turning point towards lower complications rates after 16-17 cases, whereas surgeons C and D showed an average performance. The median time between consecutive VAMLAs was shorter for surgeons A and B (13.0 vs 28.5-38.0 days for surgeons C and D). Overcoming the learning curve, complication rates of surgeons A and B decreased from 19% to 3% and from 18% to 5%, respectively. Operation time and blood loss showed a significant improvement after, respectively, 81-100 and 61-80 procedures compared to the first 20 procedures. CONCLUSIONS: VAMLA is a safe procedure to adopt and perform with acceptable complication rates from the first operation onward, regardless of the caseload. To overcome its learning curve, 16-17 cases are required, preferably at least 1 per 2 weeks.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/cirurgia , Curva de Aprendizado , Neoplasias Pulmonares/cirurgia , Excisão de Linfonodo/métodos , Mediastinoscopia/métodos , Estadiamento de Neoplasias/métodos , Cirurgia Torácica Vídeoassistida/métodos , Idoso , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/secundário , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico , Linfonodos/patologia , Linfonodos/cirurgia , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos
10.
J Thorac Dis ; 12(4): 1475-1487, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32395285

RESUMO

BACKGROUND: Computed tomography (CT) and two-view chest radiographies are the most commonly used imaging techniques to quantify the severity of pectus excavatum (PE) and pectus carinatum (PC). Both modalities expose patients to ionizing radiation that should ideally be avoided, especially in pediatric patients. In an effort to diminish this exposure, three-dimensional (3D) optical surface imaging has recently been proposed as an alternative method. To assess its clinical value as a tool to determine pectus severity we conducted a systematic review in which we assessed all studies that compared 3D scan-based pectus severity measurements with those derived from CT-scans and radiographies. METHODS: Six scientific databases and three registries were searched through April 30th, 2019. Data regarding the correlation between severity measures was extracted and submitted to meta-analysis using the random-effects model and I2-test for heterogeneity. RESULTS: Five observational studies were included, enrolling 75 participants in total. Pooled analysis of participants with PE demonstrated a high positive correlation coefficient of 0.89 [95% confidence interval (CI): 0.81 to 0.93; P<0.001] between the CT-derived Haller index (HI) and its 3D scan equivalent based on external measures. No heterogeneity was detected (I2=0.00%; P=0.834). CONCLUSIONS: 3D optical surface scanning is an attractive and promising imaging technique to determine the severity of PE without exposure to ionizing radiation. However, further research is needed to determine novel cut-off values for 3D scans to facilitate clinical decision making and help determine surgical candidacy. No evidence was found that supports nor discards the use of 3D scans to determine PC severity.

11.
Eur J Cardiothorac Surg ; 56(5): 819-829, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31329896

RESUMO

Primary spontaneous pneumothorax affects up to 28 patients per 100 000 population yearly and is commonly resolved by chest tube drainage. However, drainage is also known to be associated with ipsilateral recurrence rates ranging from 25% to 43%. Preventive video-assisted thoracoscopic surgery (VATS) may be an effective alternative to diminish these recurrence rates and its associated morbidity. The aim of this study was to compare the efficacy of chest tube drainage and VATS as first line treatments of an initial episode of primary spontaneous pneumothorax. The MEDLINE, EMBASE, CENTRAL and Clinicaltrials.gov databases were searched through 16 September 2018. Data regarding the ipsilateral recurrence rate and the length of hospitalization were extracted and submitted to meta-analysis using the random-effects model and the I2 test for heterogeneity. Two randomized controlled trials and 2 observational studies were included, enrolling a total of 479 patients. Pairwise analysis demonstrated significantly reduced ipsilateral recurrence rates [odds ratio 0.15, 95% confidence interval (CI) 0.07-0.33; P < 0.00001] and length of hospitalization (standardized mean difference -2.19, 95% CI -4.34 to -0.04; P = 0.046) in favour of VATS. However, a significant level of heterogeneity was detected for the length of hospitalization (I2 = 97%; P < 0.00001). Subgroup analysis that stratified study design found no statistical differences regarding recurrence rate. In conclusion, VATS can be an effective and attractive alternative to standard chest tube drainage, with reduced ipsilateral recurrence rates and length of hospitalization. However, given the low quality of the majority of included studies, more well-designed randomized controlled trials are necessary to strengthen the current evidence.


Assuntos
Tubos Torácicos , Drenagem , Pneumotórax , Cirurgia Torácica Vídeoassistida , Adulto , Feminino , Humanos , Masculino , Pneumotórax/epidemiologia , Pneumotórax/cirurgia , Complicações Pós-Operatórias , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Adulto Jovem
12.
Crit Care Resusc ; 19(Suppl 1): 53-61, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29084502

RESUMO

OBJECTIVES: The use of post-cardiotomy extracorporeal life support (PC-ECLS) has increased worldwide over the past years but a concurrent decrease in survival to hospital discharge has also been observed. We analysed use and outcome of PC-ECLS at the Maastricht University Medical Center. DESIGN: A retrospective study of a single-centre PC-ECLS cohort. Patient characteristics and in-hospital outcomes were evaluated. SETTING: Patients who underwent PC-ECLS due to intra- or peri-operative cardiogenic shock or cardiac arrest were included. Descriptive statistics were analysed and frequency analysis and testing of group differences were performed. PARTICIPANTS: Eighty-six patients who received PC-ECLS between October 2007 and June 2017 were included. The mean age of the population was 65 years (range, 31-86 years), and 65% were men. MAIN OUTCOME MEASURES: Survival rates were calculated and PC-ECLS management data and complications were assessed. RESULTS: Pre-ECLS procedures were isolated coronary artery bypass grafting (CABG) (22%), isolated valve surgery (16%), thoracic aorta surgery (4%), a combination of CABG and valve surgery (21%) or other surgery (24%). PC-ECLS was achieved via central cannulation in 17%, peripheral cannulation in 65%, or by a combination in 17%. The median duration of PC-ECLS was 5.0 days (IQR, 6.0 days). Weaning was achieved in 49% of patients, and 37% survived to discharge. Post-operative bleeding (overall rate, 42%) showed a trend towards a reduced rate over more recent years. CONCLUSIONS: Our experience confirms an increased use of PC-ECLS during the last 10 years and shows that, by carefully addressing patient management and complications, survival rat e may be satisfactory, and improved outcome may be achieved in such a challenging ECLS setting.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Parada Cardíaca , Complicações Pós-Operatórias/terapia , Choque Cardiogênico/terapia , Adulto , Animais , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Ratos , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Taxa de Sobrevida , Resultado do Tratamento
13.
Eur J Heart Fail ; 19 Suppl 2: 84-91, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28470925

RESUMO

INTRODUCTION/AIM: Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) support is increasingly used in refractory cardiogenic shock and cardiac arrest, but is characterized by a rise in afterload of the left ventricle (LV) which may ultimately either further impair or delay cardiac contractility improvement. The aim of this study was to provide a comprehensive overview regarding the different LV venting techniques and results currently available in the literature. METHODS: A systematic literature search was performed in the PubMed database: 207 articles published between 1993 and 2016 were included. Papers dealing with pre-clinical studies, overlapping series, and association with other assist devices were excluded from the review, with 45 published papers finally selected. Heterogeneous indications for LV unloading were reported. The selected literature was divided into subgroups, according to the location or the performed procedure for LV venting. RESULTS: Case reports or case series accounted for 60% of the papers, while retrospective study represented 29% of them. Adult series were present in 67%, paediatric patients in 29%, and a mixed population in 4%. LV unloading was performed percutaneously in 84% of the cases. The most common locations of unloading was the left atrium (31%), followed by indirect unloading (intra-aortic balloon pump) (27%), trans-aortic (27%), LV (11%), and pulmonary artery (4%). Percutaneous trans-septal approach was reported in 22%. Finally, the unloading was conducted surgically in 16%,with open chest surgery in 71%, and minimally invasive surgery in 29% of surgical cases. CONCLUSION: Nowadays, only a few data are available about left heart unloading in V-A ECMO support. Despite the well-known controversy, IABP remains widely used in combination with V-A ECMO. Percutaneous approaches utilizing unloading devices is becoming an increasingly used option. However, further studies are required to establish the optimal LV unloading method.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Balão Intra-Aórtico/métodos , Choque Cardiogênico/terapia , Humanos
14.
Innovations (Phila) ; 11(3): 201-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27355130

RESUMO

OBJECTIVE: We present the first testing study on the ABLA-BOX, a new in vitro module of hybrid atrial fibrillation ablation. METHODS: ABLA-BOX consists of two chambers that mimic the epicardial and endocardial sides of the heart. The septum between chambers provides catheter access on both sites of the cardiac tissue. A circuit, filled with freshly obtained porcine blood, including a pump, an oxygenator, and a heating device, circulate the blood inside the system. Left atrial fresh tissue is mounted on a tissue holder and magnetically fixed. Epicardial and endocardial catheters are fixed on the catheter holders and blocked with the locker knob. The system allows control of ablation force, flow rate, temperature, and flow pattern. RESULTS: Epicardial contact force of 100 g and endocardial force of 30 g resulted in larger lesion volumes (P < 0.001), areas (P < 0.001), and lesion diameters (P = 0.03 and P = 0.008), than the combination of 100/20 g. In addition, with a flow rate of 5 L/min, lesion volumes (P = 0.02), areas (P < 0.001), and diameters (both, P < 0.001) were significantly larger in comparison with those of 3 L/min. Furthermore, dimensions (both, P < 0.001), volume (P < 0.001), and area (P < 0.001) of the lesions at a circulating blood temperature of 38.0°C were larger than with a lower blood temperature (36.0°C). Finally, ablations made under stable flow pattern resulted in greater lesion diameters (P = 0.04 and P = 0.03) as well as larger volumes (P = 0.02) and areas (P = 0.03) than under turbulent-like flow reproduced with the system rotor set to 400 rpm. CONCLUSIONS: The ABLA-BOX allowed easy hybrid ablation with different setups, which can provide cardiologists and cardiac surgeons with reliable and more valuable insights.


Assuntos
Ablação por Cateter/instrumentação , Animais , Fibrilação Atrial/cirurgia , Desenho de Equipamento , Sistema de Condução Cardíaco/fisiopatologia , Modelos Animais , Suínos
15.
Eur J Cardiothorac Surg ; 49(3): 901-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26248822

RESUMO

OBJECTIVES: This proof-of-concept study examined the haemodynamic performance as well as the coronary and visceral organ perfusion using a new short balloon for intra-aortic counterpulsation (IABP) in a swine model of myocardial ischaemia. METHODS: Eighteen healthy pigs underwent 120-min ligation of the left anterior descending coronary artery followed by 6 h of reperfusion, and they were randomly assigned into 3 groups undergoing IABP implantation with a 35-ml short balloon (n = 6), a 40-ml short balloon (n = 6) or no IABP implantation (controls, n = 6). Haemodynamics, and visceral and coronary flows were measured at baseline (t0), at 2 h of ischaemia (t1) and every hour thereafter until 6 h of reperfusion (from tR1 to tR6), respectively. RESULTS: Mesenteric and renal flows increased significantly at tR1 only in the IABP groups (all, P < 0.001) and were significantly higher than controls throughout the reperfusion periods (P < 0.001). Coronary systolic and diastolic blood flows increased only at tR1 in the IABP groups (all, P < 0.001) but were higher than controls at tR1-tR6. The IABP was associated with enhanced haemodynamics compared with controls. No difference was detected using different balloon volumes (all, P > 0.05). CONCLUSIONS: The new short balloon significantly increased visceral flow, enhanced haemodynamics and improved coronary circulation during reperfusion following myocardial ischaemia in our experimental model.


Assuntos
Balão Intra-Aórtico/métodos , Isquemia Miocárdica/cirurgia , Animais , Modelos Animais de Doenças , Fluxo Sanguíneo Regional/fisiologia , Suínos
16.
Eur J Cardiothorac Surg ; 49(5): 1361-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26646809

RESUMO

OBJECTIVES: We compare a short and a standard-size balloon with same filling volumes to verify the differences in terms of visceral flow, coronary circulation and haemodynamic performance during aortic counterpulsation in an animal model of myocardial ischaemia-reperfusion injury. METHODS: Eighteen healthy pigs underwent 120-min ligation of the left anterior descending coronary artery followed by 6 h of reperfusion, and they were randomly assigned to have intra-aortic balloon counterpulsation (IABP) with a 40-ml short-balloon (n = 6) or a 40-ml standard-length balloon (n = 6), or to undergo no IABP implantation (controls, n = 6). Haemodynamics and visceral and coronary flows were measured at baseline (t0), at 2 h of ischaemia (t1) and every hour thereafter until 6 h of reperfusion (from tR1 to tR6), respectively. RESULTS: Mesenteric flows increased significantly at tR1 only in the short-balloon group (P < 0.001) and it was constantly higher than in the standard-balloon group regardless of mean arterial pressure, systemic vascular resistance and cardiac output (CO; all, P < 0.001). Renal blood flows were significantly increased during IABP treatment with values constantly and significantly higher in short balloons at any following experimental step (all, P < 0.05). IABP improved CO and coronary blood flow, and reduced afterload, myocardial resistances and myocardial oxygen consumption without differences between the short and the standard-length balloon (all, P > 0.05). CONCLUSIONS: The short balloon prevents visceral ischaemia and, compared with the standard-size balloon, it does not lose IABP beneficial cardiac and coronary-related effects. Further studies are warranted to confirm our findings.


Assuntos
Balão Intra-Aórtico/instrumentação , Balão Intra-Aórtico/métodos , Isquemia Miocárdica/cirurgia , Reperfusão Miocárdica/métodos , Animais , Aorta/fisiologia , Pressão Sanguínea/fisiologia , Modelos Animais de Doenças , Modelos Cardiovasculares , Distribuição Aleatória , Suínos
17.
Innovations (Phila) ; 11(1): 46-53; discussion 53, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26901748

RESUMO

OBJECTIVE: Visceral ischemia can be a potentially life-threatening complication of intra-aortic balloon pump (IABP) support. A shorter IABP catheter might lead to a reduction of visceral complications. In this animal study, we evaluate the effects of a 35-mL short catheter in comparison with a 40-mL standard-sized catheter. METHODS: Eighteen healthy swine underwent 120-minute ligation of the left anterior descending coronary artery followed by 6 hours of reperfusion being supported by either a short IABP catheter (short group) (n = 6) or a long IABP catheter (long group) (n = 6) or with no assistance (controls) (n = 6). Hemodynamics, visceral and coronary flows, as well as biochemical markers were evaluated throughout the different phases of the protocol. RESULTS: Mesenteric flows increased significantly at reperfusion (P < 0.001 both) remaining constant afterward (all, P > 0.05) in the short group, while remaining significantly lower in the long group at the start of reperfusion, remaining constantly lower than the short group and controls (P < 0.001 vs short, P < 0.003 vs controls). In both long and short groups, catheters improved renal flows at reperfusion (P < 0.001 both) without any further variation (P > 0.05). In the short group, the flows were higher during the whole of reperfusion (all, P < 0.05). Intra-aortic balloon pump support improved hemodynamic indices and coronary blood flows during reperfusion to a similar extent in both the small and the long group (P > 0.05). CONCLUSIONS: The short IABP catheter proved to be as effective as the standard-sized catheter in supporting hemodynamics and coronary circulation. Furthermore, it even improves visceral flows in comparison with conventional IABP catheters.


Assuntos
Circulação Coronária/fisiologia , Balão Intra-Aórtico/instrumentação , Vísceras/irrigação sanguínea , Animais , Hemodinâmica , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/veterinária , Modelos Animais , Distribuição Aleatória , Suínos
18.
Ann Thorac Surg ; 101(4): 1485-93, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26706752

RESUMO

BACKGROUND: Changes in hemodynamics, coronary circulation, visceral flow, and biochemical marker rate reduction or volume deflation for intraaortic balloon pump discontinuation were assessed. METHODS: Twelve healthy pigs were randomly assigned to two groups, the rate-based (RB, n = 6) and volume-based weaning groups (VB, n = 6). Hemodynamics and visceral and coronary flows were measured at baseline after 2 hours of intraaortic balloon pump 1:1, during the first 5 hours of weaning (frequency rate reduced to 1:2 in the RB group and volume decreased by 10%/h in the VB group), after 1 hour of frequency rate 1:3 in the RB group or a volume decrease by 75% in the VB group, 2 hours after withdrawal, and 4 hours after withdrawal. RESULTS: The animals weaned by progressive VB deflation showed a greater degree of vasodilation, better cardiac output and stroke volume, fewer negative values of cardiac cycle efficiency, and higher dP/dTmax compared with those weaned by RB reduction (p < 0.05 for all). The VB group also exhibited increased coronary flow, lower oxygen consumption of the myocardium, and coronary resistance during VB weaning (p < 0.05 for all). The serum lactate level was lower in the VB group at each experimental point (p < 0.05 for all), but visceral flows were scarcely affected by the weaning method. CONCLUSIONS: Volume reduction was the most effective weaning method considering that frequency reduction weaning was responsible for significant negative effects on hemodynamics and coronary circulation.


Assuntos
Débito Cardíaco/fisiologia , Hemodinâmica/fisiologia , Balão Intra-Aórtico/métodos , Volume Sistólico/fisiologia , Animais , Circulação Coronária/fisiologia , Modelos Animais de Doenças , Eletrocardiografia , Balão Intra-Aórtico/efeitos adversos , Intubação Intratraqueal/métodos , Monitorização Fisiológica/métodos , Distribuição Aleatória , Sensibilidade e Especificidade , Suínos , Fatores de Tempo , Desmame
19.
J Cardiothorac Surg ; 11(1): 75, 2016 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-27142813

RESUMO

BACKGROUND: We investigated the impact and the predictive value of sinus rhythm at 12 months (SR12) on subscales of three different HrQoL questionnaires: SF-36., EuroQoL and MFI 20. METHODS: Data of 125 cardiac surgery patients with pre-operative AF from our previous randomized trial were used. Based on their rhythm outcome patients were divided in two groups: SR12 or AF at 12 months follow up (non-SR12). All questionnaires were self-administered pre-operatively and at 3 months, 6 months and 12 months after surgery. RESULTS: Synus rhytm at 12 months was predictive of improvement of SF36- mental score (MS, p = 0.021), Euro-QoL-MS (p = 0.009), VAS (p = 0.006), and MFI 20-MS (p = 0.009). We failed to find any significant interactions between SR12 and any of the other significant risk factors: age <65 years, paroxysmal type of AF and preoperative AF duration <12 months. In contrast, SR12 was not significant in predicting physical score (PS) subscales of any of the questionnaires (all, p > 0.05) which were predicted by age <65 years (SF36-PS, p = 0.029) by paroxysmal type of AF and age <65 years (Euro-QoL-PS, p = 0.017 and p = 0.04, respectively) and by AF duration <12 months, paroxysmal type of AF and age < 65 years (MFI 20-PS, p = 0.019, p = 0.020 and p = 0.015, respectively). CONCLUSIONS: Specific mental-related HrQoL scales are much more sensitive to sinus rhythm conversion. Sinus rithm mantainance shows significant effects on mental scores independently of other cofactors. Successful conversion to sinus rhythm after surgical ablation during cardiac surgery does not significantly affect phisical health related quality of life during 1 year follow up.


Assuntos
Fibrilação Atrial/prevenção & controle , Ponte de Artéria Coronária , Qualidade de Vida , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/psicologia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Valor Preditivo dos Testes , Inquéritos e Questionários , Resultado do Tratamento
20.
J Interv Card Electrophysiol ; 45(2): 189-97, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26728030

RESUMO

PURPOSE: Data on epicardial contact force efficacy in dual epicardial-endocardial atrial fibrillation ablation procedures are lacking. We present an in vitro study on the importance of epicardial and endocardial contact forces during this procedure. METHODS: The in vitro setup consists of two separate chambers, mimicking the endocardial and epicardial sides of the heart. A circuit, including a pump and a heat exchanger, circulates porcine blood through the endocardial chamber. A septum, with a cut out, allows the placement of a magnetically fixed tissue holder, securing porcine atrial tissue, in the middle of both chambers. Two trocars provide access to the epicardium and endocardium. Force transducers mounted on both catheter holders allow real-time contact force monitoring, while a railing system allows controlled contact force adjustment. We histologically assessed different combinations of epi-endocardial radiofrequency ablation contact forces using porcine atria, evaluating the ablation's diameters, area, and volume. RESULTS: An epicardial ablation with forces of 100 or 300 g, followed by an endocardial ablation with a force of 20 g did not achieve transmurality. Increasing endocardial forces to 30 and 40 g combined with an epicardial force ranging from 100 to 300 and 500 g led to transmurality with significant increases in lesion's diameters, area, and volumes. CONCLUSIONS: Increased endocardial contact forces led to larger ablation lesions regardless of standard epicardial pressure forces. In order to gain transmurality in a model of a combined epicardial-endocardial procedure, a minimal endocardial force of 30 g combined with an epicardial force of 100 g is necessary.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Tato , Animais , Fibrilação Atrial/patologia , Terapia Combinada/métodos , Módulo de Elasticidade , Átrios do Coração/patologia , Técnicas In Vitro , Estresse Mecânico , Propriedades de Superfície , Suínos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa