Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Europace ; 20(5): 772-777, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29741689

RESUMO

Aims: The efficacy of the second-generation cryoballoon (CB) ablation in patients with atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in elderly patients is missing. The aim of this study was to evaluate the long-term success rate of pulmonary vein isolation (PVI) in patients ≥75 years vs. <75 years using the second-generation 28mm CB. Methods and results: Eighty patients [n = 40 ≥75 years (Group 1); n = 40 <75 years (Group 2)] with paroxysmal [n = 37 (46%) or persistent (n = 43 (54%)] AF were included. Median follow-up was 12 [6;18] months (Group 1 vs. 13 [6;27]) months (Group 2; P = 0.8). PVI was performed in all patients using cryoablation. Follow-up was obtained using 24h-Holter monitoring or via an implanted loop recorder or pacemaker. CHA2DS2VASc-Score (Group 1: 4 [4;5] vs. Group 2: 2 [1;3], P < 0.001) and HASBLED-Score (Group 1: 2 [2;3] and Group 2: 2 [1;3], (P = 0.009)) differed significantly between the two groups. Mean fluoroscopy time was 22.9 [16.3;31.9] in Group 1 and 24.5 [19.1;30.6] in Group 2 (P = 0.75), and mean procedure time was 125 min [105;151] in Group 1 and 130.5 min [117.5;147.3] in Group 2 (P = 0.66). Arrhythmia recurrence was similar in Group 1 and Group 2 (12/40 (30%) vs. 10/40 (25%) (P = 0.62). One transient ischaemic attack occurred in Group 2. No further major complications were documented in this patients cohort. Conclusion: CB ablation in patients ≥75 years has favourable success rates and similar complication rates compared with patients <75 years.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Efeitos Adversos de Longa Duração , Fatores Etários , Idoso , Fibrilação Atrial/diagnóstico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Eletrocardiografia Ambulatorial/métodos , Feminino , Seguimentos , Humanos , Efeitos Adversos de Longa Duração/diagnóstico , Efeitos Adversos de Longa Duração/etiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
2.
Clin Cardiol ; 40(11): 1095-1099, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28846806

RESUMO

BACKGROUND: Data are limited on the safety of periprocedural anticoagulation with novel oral anticoagulants (NOACs) in patients undergoing pulmonary vein isolation (PVI) using the second-generation cryoballoon (CB) for the treatment of atrial fibrillation. HYPOTHESIS: We hypothesized that the incidence of acute periprocedural complications in patients undergoing PVI do not differ between patients treated with VKA compared to NOACs. METHODS: In 200 consecutive patients (mean age, 64.3 _ 10.6 years; female, n = 83) with symptomatic atrial fibrillation, PVI using the second-generation 28-mm CB was performed. In patients treated with NOACs, the medication was stopped the day of the procedure and continued the evening after the procedure with a reduced dosage. Patients treated with phenprocoumon were continued on uninterrupted phenprocoumon with a target INR of 2 to 3. If INR was <2, bridging with low-molecular-weight heparin was performed. RESULTS: Forty-seven of 200 patients (23.5%) were treated with a vitamin K antagonist (VKA) and 55 (27.5%) were treated with apixaban, 67 (33.5%) with rivaroxaban, and 31 (15.5%) with dabigatran. Seven (3.5%) major complications occurred in the overall population. Major bleeding complications did not differ significantly between the 2 groups (P = 0.23). One patient taking VKA had a pericardial tamponade at the end of the procedure; 2 patients treated with apixaban developed a groin hematoma requiring surgical intervention. Transient ischemic attack occurred in 1 patient of the apixaban and rivaroxaban group. CONCLUSIONS: Apixaban, rivaroxaban, and dabigatran, compared with uninterrupted VKA, did not show a higher risk for major bleeding or ischemic complications in patients undergoing PVI using the second-generation CB.


Assuntos
Antitrombinas/administração & dosagem , Fibrilação Atrial/terapia , Cateteres Cardíacos , Criocirurgia/instrumentação , Dabigatrana/administração & dosagem , Inibidores do Fator Xa/administração & dosagem , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Rivaroxabana/administração & dosagem , Administração Oral , Idoso , Antitrombinas/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Transtornos Cerebrovasculares/etiologia , Criocirurgia/efeitos adversos , Dabigatrana/efeitos adversos , Esquema de Medicação , Monitoramento de Medicamentos/métodos , Desenho de Equipamento , Inibidores do Fator Xa/efeitos adversos , Feminino , Heparina de Baixo Peso Molecular/administração & dosagem , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Femprocumona/administração & dosagem , Hemorragia Pós-Operatória/induzido quimicamente , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Rivaroxabana/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Vitamina K/antagonistas & inibidores
3.
Heart Rhythm ; 13(9): 1817-22, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27241353

RESUMO

BACKGROUND: The efficacy of the second-generation cryoballoon (CB) in patients with paroxysmal atrial fibrillation (AF) has been demonstrated previously. Data on the efficacy of CB ablation in patients with persistent AF are sparse. OBJECTIVE: The aim of this study was to evaluate the 2-year success rate of pulmonary vein isolation in patients with persistent AF using the second-generation CB. METHODS: Fifty consecutive patients (mean age 64.6 ± 9.9 years; 19 women [38%]) with persistent AF were included in this analysis. The mean follow-up period was 22 ± 11 months. All patients were ablated using the second-generation 28-mm CB. Isolation of the pulmonary veins was confirmed using a spiral mapping catheter. In all patients, follow-up was obtained using 24-hour Holter monitoring or via interrogation of an implanted loop recorder or pacemaker. RESULTS: The mean left atrial diameter was 43.6 ± 5.6 mm, the mean CHA2DS2-VASc score was 2.8 ± 1.5, and the mean HAS-BLED score was 2.1 ± 1.2. The mean fluoroscopy time was 25.8 ± 9 minutes, and the mean procedural time was 146.4 ± 37.8 minutes. After 22 ± 11 months, the frequency of arrhythmia recurrence was 22 of 50 (44%) in the overall group (paroxysmal AF 6 of 22 [27%]; persistent AF 16 of 22 [73%]). No major complications occurred. Aneurysma spurium not requiring surgical intervention occurred in 1 (2%) patient. No phrenic nerve palsy was observed. CONCLUSION: Two years' results after pulmonary vein isolation using the second-generation CB in patients with persistent AF are promising. The clinical success rate appears to be similar to the reported success rates of radiofrequency ablation for the treatment of persistent AF.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Veias Pulmonares/cirurgia , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Falha de Tratamento , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa