Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 423, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811940

RESUMO

BACKGROUND: The emerging of the C2 isthmus screw fixation technique is gaining popularity in the setting of atlantoaxial dislocation or other conditions requiring fixation of C2. However, the biomechanical stability of this fixation is poorly understood. PURPOSE: To compare and elucidate the biomechanical stability of C2 pedicle screw (C2PS), C2 isthmus screw (C2IS) and C2 short isthmus screw (C2SIS) fixation techniques in atlantoaxial dislocation (AAD). METHOD: A three-dimensional finite element model (FEM) from occiput to C3 was established and validated from a healthy male volunteer. Three FEMs, C1 pedicle screw (PS)-C2PS, C1PS-C2IS, C1PS-C2SIS were also constructed. The range of motion (ROM) and the maximum von Mises stress under flexion, extension, lateral bending and axial rotation loading were analyzed and compared. The pullout strength of the three fixations for C2 was also evaluated. RESULT: C1PS-C2IS model showed the greatest decrease in ROM with flexion, extension, lateral bending and axial rotation. C1PS-C2PS model showed the least ROM reduction under all loading conditions than both C2IS and C2SIS. The C1PS-C2PS model had the largest von Mises stress on the screw under all directions followed by C1PS-C2SIS, and lastly the C1PS-C2IS. Under axial rotation and lateral bending loading, the three models showed the maximum and minimum von Mises stress on the screw respectively. The stress of the three models was mainly located in the connection of the screw and rod. Overall, the maximum screw pullout strength for C2PS, C2IS and C2SIS were 729.41N, 816.62N, 640.54N respectively. CONCLUSION: In patients with atlantoaxial dislocations, the C2IS fixation provided comparable stability, with no significant stress concentration. Furthermore, the C2IS had sufficient pullout strength when compared with C2PS and C2SIS. C2 isthmus screw fixation may be a biomechanically favourable option in cases with AAD. However, future clinical trials are necessary for the evaluation of the clinical outcomes of this technique.


Assuntos
Articulação Atlantoaxial , Análise de Elementos Finitos , Luxações Articulares , Amplitude de Movimento Articular , Humanos , Articulação Atlantoaxial/cirurgia , Articulação Atlantoaxial/fisiopatologia , Masculino , Fenômenos Biomecânicos/fisiologia , Luxações Articulares/cirurgia , Luxações Articulares/fisiopatologia , Adulto , Parafusos Pediculares , Parafusos Ósseos , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos
2.
Chemistry ; 29(57): e202302041, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37507840

RESUMO

A novel visible-light photoredox strategy is reported for the efficient dehydroxylative alkylation of a wide array of α-hydroxy carboxylic acid derivatives using diaryl boron radical. The reaction features readily accessible starting materials, broad substrate scope with excellent functionality tolerance. Preliminary mechanistic studies reveal that the spin-center shift process is responsible for the C-O bond activation, which is promoted by the diaryl boron radical generated from bench-stable and commercially available tetraphenyl borate (NaBPh4 ).

3.
Spine J ; 24(7): 1153-1161, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38447872

RESUMO

BACKGROUND: Bone mineral density plays a key role in the assessment of operative instrumentation complications and clinical outcomes. The MRI-based vertebral bone quality (VBQ) score has been introduced as a novel marker of bone quality. However, few studies have investigated the relationship between VBQ score and patients associated with cervical ossification of the posterior longitudinal ligament (OPLL). PURPOSE: The aims of the study were (1) to reveal bone mineral density between cervical OPLL and cervical spondylotic myelopathy (CSM) group by VBQ score, (2) to compare the VBQ score of cervical OPLL between male and female group, (3) to explore the relationship between segmental VBQ scores associated with OPLL. STUDY DESIGN: Retrospective cohort study. PATIENT SAMPLE: Consecutive series of 425 patients at a single academic institution. OUTCOME MEASURES: MRI based measurements of C2-C7 VBQ scores. METHODS: Preoperative noncontrast T1-weighted MRIs of the cervical spine was used to measure the VBQ score. The VBQ score was defined as the mean value of the signal intensity of the vertebrae divided by that of the cerebrospinal fluid (CSF) space at the cisterna magna. Patients with cervical OPLL and CSM were matched based on age, sex, body mass index (BMI), comorbidity, medication history, diet habit, smoking, alcohol consumption via propensity score matching (PSM). Normality of each VBQ score was tested by the Shapiro-Wilk test. Wilcoxon's rank-sum test was used to compare matched cohorts. Kruskal-Wallis test was performed to compare the VBQ scores between segments. Multivariate logistic regression analysis was used to evaluate factors associated with the development of cervical OPLL. RESULTS: A total of 425 patients were assessed. For final analysis, 135 paired patients were compared between the cervical OPLL and CSM groups, and 22 paired patients were compared between male and female group associated with cervical OPLL. There were no statistically significant differences in age, sex, BMI, comorbidity, medication history, diet habit, smoking, alcohol between the matched cohorts. OPLL group was associated with lower VBQ score compared with CSM group at C3, while there were no differences in VBQ score for the other levels between the two groups. There were no differences between male and female group associated with OPLL in C2-C7 VBQ scores. VBQ scores of cervical OPLL are variable between segments, with significantly lower scores at C6, C7 compared with C1-C5. Multivariate logistic regression analysis showed that BMI was correlated with the development of OPLL (regression coefficient, 0.162; 95% confidence interval, 0.010-0.037). Additional risk factors included hypertension, calcium supple history and smoking. CONCLUSIONS: This study demonstrates that cervical OPLL is associated with lower VBQ score at C3, with no differences for the other levels when compared with CSM derived from measurements on MRI. No differences were found between male and female group associated with OPLL in C2-C7 VBQ scores. Cervical OPLL were found to have smaller VBQ score at C6, C7 compared with C1-C5. Our findings provide new insight for bone density assessment in cervical OPLL patient.


Assuntos
Vértebras Cervicais , Imageamento por Ressonância Magnética , Ossificação do Ligamento Longitudinal Posterior , Pontuação de Propensão , Espondilose , Humanos , Masculino , Ossificação do Ligamento Longitudinal Posterior/diagnóstico por imagem , Ossificação do Ligamento Longitudinal Posterior/cirurgia , Feminino , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/cirurgia , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Espondilose/diagnóstico por imagem , Espondilose/cirurgia , Densidade Óssea , Doenças da Medula Espinal/diagnóstico por imagem , Doenças da Medula Espinal/cirurgia , Adulto
4.
Se Pu ; 38(5): 572-580, 2020 May 08.
Artigo em Chinês | MEDLINE | ID: mdl-34213242

RESUMO

This study aims at the determination of ten phenolic acids in honey using high-performance liquid chromatography-diode array detection (HPLC-DAD) combined with a chemometric second-order calibration method. First, the accuracy of the model was investigated by analysis of the calibration samples and validation samples. Satisfactory results were obtained; the ten phenolic acids exhibited good linearity, and the correlation coefficient (R) was in the range 0.9982-0.9999, with average recoveries of 97.6% to 101.1%, which proved that the model was stable and reliable. Second, the types and operating conditions of the SPE columns were determined by experiments using simulated honey; HLB column was selected, washed with 0.1%(v/v) formic acid aqueous solution, and eluted with methanol. Finally, the phenolic acid contents in jujube flower honey were determined under the optimum conditions for simulated honey. The recoveries of the analytes were 62.1%-93.8%, which met the requirements considering the variety of target analytes and the complexity of the honey substrate. In addition, the efficiency of the method was validated by figures of merit and statistical parameters, including sensitivity (SEN), selectivity (SEL), root-mean-square error of prediction (RMSEP), limit of detection (LOD), and limit of quantification (LOQ); the obtained results were satisfactory. This method is simple, fast, and accurate, and it can be used for the quantitative analysis of the target analytes in complex substrates.


Assuntos
Análise de Alimentos , Mel , Hidroxibenzoatos/análise , Calibragem , Cromatografia Líquida de Alta Pressão , Mel/análise
5.
Dalton Trans ; 48(10): 3433-3439, 2019 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-30789172

RESUMO

A unique penta-coordinate nickel complex [{1,2-C6H4(SiMe2)(SiH)}2Ni(PEt3)(depe)] (6) that generates two new Si-Si single bonds has been prepared exclusively by the reaction of a chelating silyl hydride 1-(dimethylsilyl)-2-silylbenzene (4) and Ni(depe)(PEt3)2 (depe = Et2PCH2CH2PEt2) in a 2 : 1 ratio. Complex 6 is the first example of mononuclear silyl nickel complexes containing a Si-Si single bond formed in situ. Interestingly, framework 6 exhibits reversible single-crystal-to-single-crystal transformations upon the removal and rebinding of the coordinating PEt3 molecule, which give rise to a PEt3-free complex [{1,2-C6H4(SiMe2)(SiH)}2Ni(depe)] (6'), concomitant with the alteration of the coordination geometry of central metal atoms.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa