Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Electrocardiol ; 60: 33-35, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32240867

RESUMO

About 4.5-20% of patients after heart transplant require pacemaker (PM) implantation. The high infective risk profile and the low probability of pacing dependency make heart-transplanted patients the ideal candidates for a leadless single-chamber PM. We report the first multicenter experience of leadless PM implantation in a series of heart-transplanted patients with a long-term follow-up. Our data confirm the feasibility and acceptable safety of leadless device in this peculiar kind of patients, despite implantation seems to be slightly more challenging with respect to non-transplanted patients. Although more data are required, a leadless single-chamber surveillance PM seems a valuable option for heart-transplanted patients.


Assuntos
Transplante de Coração , Marca-Passo Artificial , Arritmias Cardíacas/terapia , Eletrocardiografia , Desenho de Equipamento , Humanos , Resultado do Tratamento
2.
JACC Clin Electrophysiol ; 3(11): 1275-1282, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29759624

RESUMO

OBJECTIVES: This study sought to evaluate the effects of programming a long detection in single-chamber (VVI) implantable cardioverter-defibrillators (ICDs) in the multicenter prospective ADVANCE III (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III) trial. BACKGROUND: Programming strategies may reduce unnecessary ICD shocks and their adverse effects but to date have been described only for dual-chamber ICDs. METHODS: A total of 545 subjects (85% male; atrial fibrillation 25%, left ventricular ejection fraction 31%, ischemic etiology 68%, secondary prevention indications 32%) receiving a VVI ICD were randomized to long detection (30 of 40 intervals) or standard programming (18 of 24 intervals) based on device type, atrial fibrillation history, and indication. In both arms, antitachycardia pacing (ATP) therapy during charging was programmed for episodes with cycle length 320 to 200 ms and shock only for cycle length <200 ms. Wavelet and stability functions enabled. Therapies delivered were compared using a negative binomial regression model. RESULTS: A total of 267 patients were randomized to long detection and 278 to the control group. Median follow-up was 12 months. One hundred twelve therapies (shocks and ATP) occurred in the long detection arm versus 257 in the control arm, for a 48% reduction with 30 of 40 intervals (95% confidence interval [CI]: 0.36 to 0.76; p = 0.002). In the long detection arm, overall shocks were reduced by 40% compared to the control arm (48 vs. 24; 95% CI: 0.38 to 0.94; p = 0.026) and appropriate shocks by 51% (34 vs. 74; 95% CI: 0.26 to 0.94; p = 0.033). Syncopal events did not differ between arms, but survival improved in the long detection arm. CONCLUSIONS: Among patients implanted with a VVI ICD, programming with the long detection interval significantly reduced appropriate therapies, shocks, and all-cause mortality. (Avoid DeliVering TherApies for Non-sustained Arrhythmias in ICD PatiEnts III [ADVANCEIII]; NCT00617175).


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/terapia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Desfibriladores Implantáveis/tendências , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária/estatística & dados numéricos , Estudos Prospectivos , Prevenção Secundária/estatística & dados numéricos , Volume Sistólico/fisiologia , Síncope/epidemiologia , Síncope/etiologia , Síncope/prevenção & controle , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/fisiopatologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa