Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Magn Reson Imaging ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38963154

RESUMO

BACKGROUND: Lower back pain affects 75%-85% of people at some point in their lives. The detection of biochemical changes with sodium (23Na) MRI has potential to enable an earlier and more accurate diagnosis. PURPOSE: To measure 23Na relaxation times and apparent tissue sodium concentration (aTSC) in ex-vivo intervertebral discs (IVDs), and to investigate the relationship between aTSC and histological Thompson grade. STUDY TYPE: Ex-vivo. SPECIMEN: Thirty IVDs from the lumbar spines of 11 human body donors (4 female, 7 male, mean age 86 ± 8 years). FIELD STRENGTH/SEQUENCE: 3 T; density-adapted 3D radial sequence (DA-3D-RAD). ASSESSMENT: IVD 23Na longitudinal (T1), short and long transverse (T2s* and T2l*) relaxation times and the proportion of the short transverse relaxation (ps) were calculated for one IVD per spine sample (11 IVDs). Furthermore, aTSCs were calculated for all IVDs. The degradation of the IVDs was assessed via histological Thompson grading. STATISTICAL TESTS: A Kendall Tau correlation (τ) test was performed between the aTSCs and the Thompson grades. The significance level was set to P < 0.05. RESULTS: Mean 23Na relaxation parameters of a subset of 11 IVDs were T1 = 9.8 ± 1.3 msec, T2s* = 0.7 ± 0.1 msec, T2l* = 7.3 ± 1.1 msec, and ps = 32.7 ± 4.0%. A total of 30 IVDs were examined, of which 3 had Thompson grade 1, 4 had grade 2, 5 had grade 3, 5 had grade 4, and 13 had grade 5. The aTSC decreased with increasing degradation, being 274.6 ± 18.9 mM for Thompson grade 1 and 190.5 ± 29.5 mM for Thompson grade 5. The correlation between whole IVD aTSC and Thompson grade was significant and strongly negative (τ = -0.56). DATA CONCLUSION: This study showed a significant correlation between aTSC and degenerative IVD changes. Consequently, aTSC has potential to be useful as an indicator of degenerative spinal changes. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.

2.
Skeletal Radiol ; 53(4): 791-800, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37819279

RESUMO

OBJECTIVE: Clinical-standard MRI is the imaging modality of choice for the wrist, yet limited to static evaluation, thereby potentially missing dynamic instability patterns. We aimed to investigate the clinical benefit of (dynamic) real-time MRI, complemented by automatic analysis, in patients with complete or partial scapholunate ligament (SLL) tears. MATERIAL AND METHODS: Both wrists of ten patients with unilateral SLL tears (six partial, four complete tears) as diagnosed by clinical-standard MRI were imaged during continuous active radioulnar motion using a 1.5-T MRI scanner in combination with a custom-made motion device. Following automatic segmentation of the wrist, the scapholunate and lunotriquetral joint widths were analyzed across the entire range of motion (ROM). Mixed-effects model analysis of variance (ANOVA) followed by Tukey's posthoc test and two-way ANOVA were used for statistical analysis. RESULTS: With the increasing extent of SLL tear, the scapholunate joint widths in injured wrists were significantly larger over the entire ROM compared to those of the contralateral healthy wrists (p<0.001). Differences between partial and complete tears were most pronounced at 5°-15° ulnar abduction (p<0.001). Motion patterns and trajectories were altered. Complete SLL deficiency resulted in complex alterations of the lunotriquetral joint widths. CONCLUSION: Real-time MRI may improve the functional diagnosis of SLL insufficiency and aid therapeutic decision-making by revealing dynamic forms of dissociative instability within the proximal carpus. Static MRI best differentiates SLL-injured wrists at 5°-15° of ulnar abduction.


Assuntos
Articulações do Carpo , Instabilidade Articular , Traumatismos do Punho , Humanos , Articulação do Punho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Articulações do Carpo/diagnóstico por imagem , Ligamentos Articulares/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Instabilidade Articular/diagnóstico por imagem , Traumatismos do Punho/diagnóstico por imagem
3.
J Med Syst ; 47(1): 39, 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-36961580

RESUMO

Analysis of chemical exchange saturation transfer (CEST) MRI data requires sophisticated methods to obtain reliable results about metabolites in the tissue under study. CEST generates z-spectra with multiple components, each originating from individual molecular groups. The individual lines with Lorentzian line shape are mostly overlapping and disturbed by various effects. We present an elaborate method based on an adaptive nonlinear least squares algorithm that provides robust quantification of z-spectra and incorporates prior knowledge in the fitting process. To disseminate CEST to the research community, we developed software as part of this study that runs on the Microsoft Windows operating system and will be made freely available to the community. Special attention has been paid to establish a low entrance threshold and high usability, so that even less experienced users can successfully analyze CEST data.


Assuntos
Imageamento por Ressonância Magnética , Software , Humanos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Análise dos Mínimos Quadrados
4.
Int J Mol Sci ; 23(13)2022 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-35805925

RESUMO

Based on in silico, in situ, and in vivo studies, this study aims to develop a new method for the quantitative chemical exchange saturation transfer (qCEST) technique considering multi-pool systems. To this end, we extended the state-of-the-art apparent exchange-dependent relaxation (AREX) method with a Lorentzian correction (LAREX). We then validated this new method with in situ and in vivo experiments on human intervertebral discs (IVDs) using the Kendall-Tau correlation coefficient. In the in silico experiments, we observed significant deviations of the AREX method as a function of the underlying exchange rate (kba) and fractional concentration (fb) compared to the ground truth due to the influence of other exchange pools. In comparison to AREX, the LAREX-based Ω-plot approach yielded a substantial improvement. In the subsequent in situ and in vivo experiments on human IVDs, no correlation to the histological reference standard or Pfirrmann classification could be found for the fb (in situ: τ = −0.17 p = 0.51; in vivo: τ = 0.13 p = 0.30) and kba (in situ: τ = 0.042 p = 0.87; in vivo: τ = −0.26 p = 0.04) of Glycosaminoglycan (GAG) with AREX. In contrast, the influence of interfering pools could be corrected by LAREX, and a moderate to strong correlation was observed for the fractional concentration of GAG for both in situ (τ = −0.71 p = 0.005) and in vivo (τ = −0.49 p < 0.001) experiments. The study presented here is the first to introduce a new qCEST method that enables qCEST imaging in systems with multiple proton pools.


Assuntos
Disco Intervertebral , Imageamento por Ressonância Magnética , Glicosaminoglicanos , Humanos , Imageamento por Ressonância Magnética/métodos , Prótons
5.
Int J Mol Sci ; 23(18)2022 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-36142810

RESUMO

Sodium magnetic resonance imaging (MRI) can be used to evaluate the change in the proteoglycan content in Achilles tendons (ATs) of patients with different AT pathologies by measuring the 23Na signal-to-noise ratio (SNR). As 23Na SNR alone is difficult to compare between different studies, because of the high influence of hardware configurations and sequence settings on the SNR, we further set out to measure the apparent tissue sodium content (aTSC) in the AT as a better comparable parameter. Ten healthy controls and one patient with tendinopathy in the AT were examined using a clinical 3 Tesla (T) MRI scanner in conjunction with a dual tuned 1H/23Na surface coil to measure 23Na SNR and aTSC in their ATs. 23Na T1 and T2* of the AT were also measured for three controls to correct for different relaxation behavior. The results were as follows: 23Na SNR = 11.7 ± 2.2, aTSC = 82.2 ± 13.9 mM, 23Na T1 = 20.4 ± 2.4 ms, 23Na T2s* = 1.4 ± 0.4 ms, and 23Na T2l* = 13.9 ± 0.8 ms for the whole AT of healthy controls with significant regional differences. These are the first reported aTSCs and 23Na relaxation times for the AT using sodium MRI and may serve for future comparability in different studies regarding examinations of diseased ATs with sodium MRI.


Assuntos
Tendão do Calcâneo , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Proteoglicanas , Reprodutibilidade dos Testes , Sódio
6.
MAGMA ; 34(2): 241-248, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32500389

RESUMO

OBJECTIVE: To measure sodium relaxation times and concentrations in human wrists on a clinical magnetic resonance imaging (MRI) scanner with a density-adapted radial sequence. MATERIALS AND METHODS: Sodium MRI of human wrists was conducted on a 3T MR system using a dual-tuned 1H/23Na surface coil. We performed two studies with 10 volunteers each investigating either sodium T1 (study 1) or sodium T2* (study 2) relaxation times in the radiocarpal joint (RCJ) and midcarpal joint (MCJ). Sodium concentrations of both regions were determined. RESULTS: No differences for transversal of longitudinal relaxation times were found between RCJ and MCJ (T2,s*(RCJ) = (0.9 ± 0.4) ms; T2,s*(MCJ) = (0.9 ± 0.3) ms; T2,l*(RCJ) = (14.9 ± 0.9) ms; T2,l*(MCJ) = (13.9 ± 1.1) ms; T1(RCJ) = (19.0 ± 2.4) ms; T1(MCJ) = (18.5 ± 2.1) ms). Sodium concentrations were (157.7 ± 28.4) mmol/l for study 1 and (159.8 ± 29.1) mmol/l for study 2 in the RCJ, and (172.7 ± 35.6) mmol/l for study 1 and (163.4 ± 26.3) mmol/l for study 2 in the MCJ. CONCLUSION: We successfully determined sodium relaxation times and concentrations of the human wrist on a 3T MRI scanner.


Assuntos
Cartilagem Articular , Punho , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Sódio
7.
MAGMA ; 34(2): 249-260, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32725359

RESUMO

OBJECTIVE: To establish and optimize a stable 3 Tesla (T) glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging protocol for assessing the articular cartilage of the tibiotalar joint in healthy volunteers and patients after a sustained injury to the ankle. METHODS: Using Bloch-McConnell simulations, we optimized the sequence protocol for a 3 T MRI scanner for maximum gagCEST effect size within a clinically feasible time frame of less than 07:30 min. This protocol was then used to analyze the gagCEST effect of the articular cartilage of the tibiotalar joint of 17 healthy volunteers and five patients with osteochondral lesions of the talus following ankle trauma. Reproducibility was tested with the intraclass correlation coefficient. RESULTS: The mean magnetization transfer ratio asymmetry (MTRasym), i.e., the gagCEST effect size, was significantly lower in patients than in healthy volunteers (0.34 ± 1.9% vs. 1.49 ± 0.11%; p < 0.001 [linear mixed model]). Intra- and inter-rater reproducibility was excellent with an average measure intraclass correlation coefficient (ICC) of 0.97 and a single measure ICC of 0.91 (p < 0.01). DISCUSSION: In this feasibility study, pre-morphological tibiotalar joint cartilage damage was quantitatively assessable on the basis of the optimized 3 T gagCEST imaging protocol that allowed stable quantification gagCEST effect sizes across a wide range of health and disease in clinically feasible acquisition times.


Assuntos
Cartilagem Articular , Estudos de Viabilidade , Glicosaminoglicanos , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes
8.
Magn Reson Med ; 82(3): 935-947, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31004385

RESUMO

PURPOSE: To characterize the proton exchange in aqueous urea solutions using a modified version of the WEX II filter at high magnetic field, and to assess the feasibility of performing quantitative urea CEST MRI on a 3T clinical MR system. METHODS: In order to study the dependence of the exchange-rate constant ksw of urea as a function of pH and T, the WEX-spectra were acquired at 600 MHz from urea solutions in a pH range from 6.4 to 8.0 and a temperature range from T=22∘C to 37∘C . The CEST experiments were performed on a 3T MRI scanner by applying a train of 50 Gaussian-shaped pulses, each 100-millisecond long with a spacing of 100 milliseconds, for saturation. Exchange rates of urea were calculated using the (extended) AREX metric. RESULTS: The results showed that proton exchange in aqueous urea solutions is acid and base catalyzed with the rate constants: ka=(9.95±1.1)×106 l/(mol·s) and kb=(6.21±0.21)×106 l/(mol·s), respectively. Since the urea protons undergo a slow exchange with water protons, the CEST effect of urea can be observed efficiently at 3T. However, in neutral solutions the exchange rate of urea is minimal and cannot be estimated using the quantitative CEST approach. CONCLUSIONS: By means of the WEX-spectroscopy, the kinetic parameters of the proton exchange in urea solutions have been determined. It was also possible to estimate the exchange rates of urea in a broad range of pH values using the CEST method at a clinical scanner.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Prótons , Processamento de Sinais Assistido por Computador , Ureia/química , Água/química , Imagens de Fantasmas
9.
Eur Radiol ; 29(12): 6443-6446, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31278582

RESUMO

KEY POINTS: • Molecular intervertebral disc damage was associated with LBP and radiculopathy.• Patients with radiculopathy and LBP demonstrated a depletion of gagCEST values compared with healthy controls.• GagCEST imaging may be a non-invasive tool for investigation of degeneration processes of lumbar intervertebral discs (IVDs). GagCEST imaging may be an imaging biomarker for biochemical IVD alterations.


Assuntos
Degeneração do Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/diagnóstico por imagem , Dor Lombar/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Radiculopatia/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Feminino , Glicosaminoglicanos/metabolismo , Humanos , Disco Intervertebral/metabolismo , Degeneração do Disco Intervertebral/complicações , Degeneração do Disco Intervertebral/metabolismo , Dor Lombar/etiologia , Dor Lombar/metabolismo , Vértebras Lombares/metabolismo , Vértebras Lombares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiculopatia/etiologia , Radiculopatia/metabolismo , Adulto Jovem
10.
Clin Exp Rheumatol ; 37(2): 179-185, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29998824

RESUMO

OBJECTIVES: The aim of the study was to investigate biochemical cartilage composition under methotrexate (MTX) therapy and to intra-individually assess the impact of inflammation severity on cartilage composition by using dGEMRIC MRI in patients with early rheumatoid arthritis (eRA). METHODS: dGEMRIC of MCP joints of the index and middle finger of 28 patients from the AthroMark cohort were examined prior to MTX-therapy as well as after 3 and 6 month. OMERACT RA MRI score and clinical parameters (CRP and DAS28) were registered at any time point. Each patient's second and third MCP joints were dichotomised into the joint with more severe synovitis versus the joint with less severe synovitis according to the RAMRIS synovitis subscore. RESULTS: MCP joints with more severe synovitis ('bad joints') demonstrated significantly lower dGEMRIC values compared to MCP joints with less severe synovitis ('good joints') at time-points 0 and 3 months (p=0.002; p=0.019, respectively). After 6 months of MTX therapy no significant difference of dGEMRIC index was found between good and bad joint (p=0.086). CONCLUSIONS: Under MTX therapy, biochemical cartilage integrity remains stable; no further cartilage destruction occurred if patients were treated early in the course of the disease. In addition, six months of MTX therapy triggered an alignment of dGEMRIC index of MCP joints with initially severe synovitis and less severe synovitis in an intra-individual assessment. This underlines the importance of an early treatment in eRA to reduce further cartilage damage of the inflamed joints.


Assuntos
Antirreumáticos/uso terapêutico , Artrite Reumatoide , Metotrexato/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/patologia , Cartilagem/diagnóstico por imagem , Cartilagem/patologia , Humanos , Imageamento por Ressonância Magnética , Sinovite
11.
J Magn Reson Imaging ; 47(1): 160-167, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28471524

RESUMO

PURPOSE: To evaluate the feasibility of renal diffusion quantification using the Padé exponent model (PEM) in healthy subjects. MATERIALS AND METHODS: Diffusion measurements were completed in 10 healthy subjects (mean age, 32.4 ± 8.9 years) on a 3T MRI scanner (Magnetom Trio, Siemens AG, Germany). A respiratory-triggered echo planar imaging sequence (15 slices with 6 mm thickness; 16 b-values [0-750 s/mm2 ]; three diffusion directions; field of view: 400 × 375 mm; Matrix 192 × 192; repetition time/echo time: 3000/74 ms) was acquired in the coronal direction. Parameter maps were calculated for the monoexponential, biexponential, kurtosis models, and the PEM. A regression analysis using an R2 -test and corrected Akaike information criterion (AICc) was performed to identify the best mathematical fitting to the measured diffusion-weighted imaging signal decay. RESULTS: The mathematical accuracy of the PEM was significantly higher than for the other three-parameter and the monoexponential model (P < 0.05), which enables more precise information about the deviation of the Gaussian behavior of the diffusion signal by the PEM. The biexponential model showed better fitting to the diffusion signal (medullar Rbi2 0.989 ± 0.008, AICcbi 113.3 ± 6.6; cortical Rbi2 0.992 ± 0.006, AICcbi 113.3 ± 5.2) than the three-parameter models (medullar RPadé2 0.965 ± 0.016, AICcPadé 122.6 ± 6.4, RK2 0.954 ± 0.019, AICcK 128.5 ± 6.0; cortical RPadé2 0.989 ± 0.005, AICcPadé 116.3 ± 4.4, RK2 0.985 ± 0.007, AICcK 120.4 ± 4.8). The monoexponential model fits least to the diffusion signal in the kidney (medullar Rmono2 0.898 ± 0.039, AICcmono 141.4 ± 5.6; cortical Rmono2 0.961 ± 0.013, AICcmono 135.4 ± 4.8). CONCLUSION: The PEM is a novel promising approach to quantify diffusion properties in the human kidney and might further improve functional renal MR imaging. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:160-167.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Rim/diagnóstico por imagem , Adulto , Algoritmos , Feminino , Taxa de Filtração Glomerular , Voluntários Saudáveis , Humanos , Masculino , Modelos Anatômicos , Modelos Teóricos , Distribuição Normal , Adulto Jovem
12.
Semin Musculoskelet Radiol ; 22(2): 245-260, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29672812

RESUMO

Cartilage degeneration is one of the most common chronic age-related joint disorders leading to pain and reduced joint motion. The increasing prevalence of osteoarthritis requires accurate cartilage imaging, both clinically and in research. Detailed cartilage imaging is also necessary for traumatic cartilage lesions and for pre- and postoperative assessment of cartilage repair procedures. Although still widely used, conventional radiography bears significant limitations because it assesses cartilage indirectly by joint space width. Magnetic resonance imaging (MRI) enables direct visualization of cartilage damage along with other concomitantly affected joint tissues. Several semiquantitative grading systems and volumetric analysis methods exist to assess cartilage damage and cartilage repair on MRI. Quantification of hyaline and fibrocartilage biochemical composition is possible with novel MRI methods such as T2- and T1ρ-mapping, delayed gadolinium-enhanced MRI of cartilage, glycosaminoglycan chemical exchange saturation transfer, and sodium imaging, along with quantitative computed tomography arthrography. These techniques provide promising quantitative imaging biomarkers that can detect early cartilage changes before morphological alterations occur.


Assuntos
Doenças das Cartilagens/diagnóstico por imagem , Biomarcadores/análise , Meios de Contraste , Diagnóstico Diferencial , Humanos
13.
MAGMA ; 31(5): 645-651, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29761413

RESUMO

PURPOSE: The study compares glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging of intervertebral discs corrected for solely B0 inhomogeneities or both B0 and B1 inhomogeneities. METHODS: Lumbar intervertebral discs of 20 volunteers were examined with T2-weighted and gagCEST imaging. Field inhomogeneity correction was performed with B0 correction only and with correction of both B0 and B1. GagCEST effects measured by the asymmetric magnetization transfer ratio (MTRasym) and signal-to-noise ratio (SNR) were compared between both methods. RESULTS: Significant higher MTRasym and SNR values were obtained in the nucleus pulposus using B0 and B1 correction compared with B0-corrected gagCEST. The GagCEST effect was significantly different in the nucleus pulposus compared with the annulus fibrosus for both methods. CONCLUSION: The B0 and B1 field inhomogeneity correction method leads to an improved quality of gagCEST imaging in IVDs compared with only B0 correction.


Assuntos
Glicosaminoglicanos/análise , Disco Intervertebral/química , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Adulto , Anel Fibroso/química , Anel Fibroso/diagnóstico por imagem , Feminino , Glicosaminoglicanos/metabolismo , Voluntários Saudáveis , Humanos , Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/metabolismo , Região Lombossacral , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/estatística & dados numéricos , Núcleo Pulposo/química , Núcleo Pulposo/diagnóstico por imagem , Estudos Prospectivos , Razão Sinal-Ruído , Adulto Jovem
14.
Magn Reson Med ; 78(1): 280-284, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27484469

RESUMO

PURPOSE: To investigate, if a train of spin-lock pulses (chemical exchange saturation transfer with spin-lock pulses = CESL) improves biochemical glycosaminoglycan imaging compared with conventional chemical exchange saturation transfer with Gaussian-shaped pulses (CEST) in lumbar intervertebral discs. METHODS: T2 , CEST, and CESL imaging was performed in lumbar intervertebral discs of 15 healthy volunteers at 3 Tesla. Mean and standard deviation of the asymmetric magnetization transfer ratio (MTRasym ), the asymmetric spin-lock ratio (SLRasym ) and T2 values were calculated for nucleus pulposus (NP) and annulus fibrosus (AF). Wilcoxon test was used to analyze differences between MTRasym and SLRasym . Pearson correlation was used to determine the relationship between MTRasym , SLRasym and T2 . RESULTS: Data showed no significant difference between MTRasym and SLRasym (NP: P = 0.35; AF: P = 0.34). MTRasym and SLRasym values differed significantly between NP and AF (MTRasym : P = 0.014, SLRasym : P = 0.005). T2 values correlated significantly with MTRasym (NP: ρ = 0.76, P < 0.001; AF: ρ = 0.60, P < 0.001) and SLRasym (NP: ρ = 0.73, P < 0.001; AF: ρ = 0.47, P < 0.001). CONCLUSION: CESL does not improve the chemical exchange asymmetry effect compared with conventional CEST, but leads to comparable results. Magn Reson Med 78:280-284, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Glicosaminoglicanos/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Disco Intervertebral/diagnóstico por imagem , Disco Intervertebral/metabolismo , Imageamento por Ressonância Magnética/métodos , Imagem Molecular/métodos , Processamento de Sinais Assistido por Computador , Adulto , Simulação por Computador , Interpretação Estatística de Dados , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Modelos Estatísticos , Distribuição Normal , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin , Adulto Jovem
15.
MAGMA ; 30(5): 505-516, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28569374

RESUMO

OBJECTIVES: The goal of this study was to quantify CEST related parameters such as chemical exchange rate and fractional concentration of exchanging protons at a clinical 3T scanner. For this purpose, two CEST quantification approaches-the AREX metric (for 'apparent exchange dependent relaxation'), and the AREX-based Ω-plot method were used. In addition, two different pulsed RF irradiation schemes, using Gaussian-shaped and spin-lock pulses, were compared. MATERIALS AND METHODS: Numerical simulations as well as MRI measurements in phantoms were performed. For simulations, the Bloch-McConnell equations were solved using a two-pool exchange model. MR experiments were performed on a clinical 3T MRI scanner using a cylindrical phantom filled with creatine solution at different pH values and different concentrations. RESULTS: The validity of the Ω-plot method and the AREX approach using spin-lock preparation for determination of the quantitative CEST parameters was demonstrated. Especially promising results were achieved for the Ω-plot method when the spin-lock preparation was employed. CONCLUSION: Pulsed CEST at 3T could be used to quantify parameters such as exchange rate constants and concentrations of protons exchanging with free water. In the future this technique might be used to estimate the exchange rates and concentrations of biochemical substances in human tissues in vivo.


Assuntos
Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Humanos , Concentração de Íons de Hidrogênio , Campos Magnéticos , Imageamento por Ressonância Magnética/estatística & dados numéricos , Imagens de Fantasmas , Prótons , Ondas de Rádio , Água
16.
Acta Radiol ; 57(5): 627-32, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26253931

RESUMO

BACKGROUND: Biochemical alterations such as glycosaminoglycan (GAG) depletion occur early in the course of osteoarthritis, but cannot be detected with standard magnetic resonance techniques. With glycosaminoglycan chemical exchange saturation transfer (gagCEST), a biochemical imaging technique, it is feasible to detect biochemical components in knee joint cartilage. PURPOSE: To establish baseline values for gagCEST magnetic resonance imaging (MRI) in knee joint cartilage at 3 Tesla (T). MATERIAL AND METHODS: Twenty volunteers (8 women, 12 men; mean age, 24.55 ± 2.35 years;age range, 21-29 years) with no history or clinical findings indicative of knee joint pathologies underwent MRI at 3T. The imaging protocol included three-dimensional (3D) double-echo steady-state sequence for morphological cartilage assessment and a prototype 3D CEST pulse sequence to evaluate the CEST effects in six cartilage regions of the knee joint: (i) lateral femoral condyle; (ii) medial femoral condyle; (iii) lateral tibial plateau; (iv) medial tibial plateau; (v) patella; and (vi) trochlea. We used the asymmetry of the magnetization transfer ratio (MTRasym) parameter to quantify the gagCEST effects in these regions. RESULTS: Regional differences revealed high MTRasym values in the patellar (1.62% ± 1.19%) and the trochlear (1.17% ± 1.29%) cartilages, and low MTRasym values in the medial femoral condyle (0.41% ± 0.58%) and the lateral tibial plateau (0.52% ± 0.53%) cartilages. CONCLUSION: Regional differences in the gagCEST values must be considered when conducting gagCEST imaging of knee joint cartilage. In the future gagCEST imaging may be an additional feature in the evaluation of the biochemical composition of knee joint cartilage.


Assuntos
Biomarcadores/metabolismo , Cartilagem Articular/química , Glicosaminoglicanos/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Osteoartrite do Joelho/diagnóstico
17.
Skeletal Radiol ; 45(1): 79-85, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26377579

RESUMO

OBJECTIVE: To evaluate glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging at 3T in the assessment of the GAG content of cervical IVDs in healthy volunteers. MATERIALS AND METHODS: Forty-two cervical intervertebral discs of seven healthy volunteers (four females, three males; mean age: 21.4 ± 1.4 years; range: 19-24 years) were examined at a 3T MRI scanner in this prospective study. The MRI protocol comprised standard morphological, sagittal T2 weighted (T2w) images to assess the magnetic resonance imaging (MRI) based grading system for cervical intervertebral disc degeneration (IVD) and biochemical imaging with gagCEST to calculate a region-of-interest analysis of nucleus pulposus (NP) and annulus fibrosus (AF). RESULTS: GagCEST of cervical IVDs was technically successful at 3T with significant higher gagCEST values in NP compared to AF (1.17% ± 1.03% vs. 0.79% ± 1.75%; p = 0.005). We found topological differences of gagCEST values of the cervical spine with significant higher gagCEST effects in lower IVDs (r = 1; p = 0). We could demonstrate a significant, negative correlation between gagCEST values and cervical disc degeneration of NP (r = -0.360; p = 0.019). Non-degenerated IVDs had significantly higher gagCEST effects compared to degenerated IVDs in NP (1.76% ± 0.92% vs. 0.52% ± 1.17%; p < 0.001). CONCLUSION: Biochemical imaging of cervical IVDs is feasible at 3T. GagCEST analysis demonstrated a topological GAG distribution of the cervical spine. The depletion of GAG in the NP with increasing level of morphological degeneration can be assessed using gagCEST imaging.


Assuntos
Vértebras Cervicais/metabolismo , Glicosaminoglicanos/metabolismo , Disco Intervertebral/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagem Molecular/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Projetos Piloto , Valores de Referência , Distribuição Tecidual , Adulto Jovem
18.
J Magn Reson Imaging ; 42(6): 1517-23, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25970563

RESUMO

PURPOSE: To analyze age-dependency of glycosaminoglycan content using gagCEST (glycosaminoglycan chemical exchange saturation transfer) imaging in lumbar intervertebral discs of healthy volunteers. MATERIALS AND METHODS: In all, 70 volunteers without low back pain (mean age 44 ± 14 years, range: 21-69 years) were examined with T2 -weighted and gagCEST imaging with a 3T MR scanner, with approval of the local Ethics Committee after written informed consent was obtained. Pfirrmann grading and classification into discs without bulging and herniation, discs with bulging, and discs with herniation were performed. Only intervertebral discs without bulging and herniation were analyzed. A region-of-interest-based gagCEST analysis of nucleus pulposus (NP) and annulus fibrosus (AF) was performed. Correlation between age and gagCEST was tested within groups of equal Pfirrmann score. RESULTS: GagCEST effects decreased significantly from 3.09 ± 1.12% in 20-29 years old volunteers to -0.24 ± 1.36% in 50-59 years old volunteers (P < 0.001). In the case of Pfirrmann scores 2 and 3, a significant correlation was observed between gagCEST effect and age (Pfirrmann score 2, NP: ρ = -0.558, P < 0.001; Pfirrmann score 3, NP: ρ = -0.337, P = 0.048). For Pfirrmann scores 1 and 4, no significant correlation was obtained (Pfirrmann score 1, NP: ρ = -0.046, P = 0.824; Pfirrmann score 4, NP: ρ = -0.316, P = 0.188). CONCLUSION: We show a decreased gagCEST effect likely corresponding to decreasing glycosaminoglycans with aging. Hence, age-matched analysis of gagCEST imaging may be necessary in future studies.


Assuntos
Envelhecimento/metabolismo , Glicosaminoglicanos/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Disco Intervertebral/metabolismo , Vértebras Lombares/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Envelhecimento/patologia , Feminino , Humanos , Disco Intervertebral/anatomia & histologia , Vértebras Lombares/anatomia & histologia , Espectroscopia de Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual , Adulto Jovem
19.
J Magn Reson Imaging ; 42(4): 1057-63, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25758361

RESUMO

PURPOSE: To assess glycosaminoglycan (GAG) content of lumbar intervertebral discs (IVD) in patients with spondyloarthritis (SpA) using glycosaminoglycan chemical exchange saturation transfer (gagCEST). MATERIALS AND METHODS: Ninety lumbar intervertebral discs of nine patients with SpA and nine age-matched healthy controls (eight patients with ankylosing spondylitis; one patient with spondylitis related to inflammatory bowel disease; mean age: 44.1 ± 14.0 years; range: 27-72 years) were examined with a 3T magnetic resonance imaging (MRI) scanner in this prospective study. The MRI protocol included standard morphological, sagittal T2 -weighted (T2 w) images to assess Pfirrmann score of the five lumbar IVDs (L1 to S1) and biochemical imaging with gagCEST to calculate a region of interest analysis of nucleus pulposus (NP) and annulus fibrosus (AF). Prior to statistical testing of gagCEST effects (MTRasym values in percent) in patients and controls, IVDs were classified according to the Pfirrmann score. RESULTS: Significantly lower gagCEST values of NP and AF were found in SpA patients compared with healthy volunteers (NP: 1.41% ± 0.41%, P = 0.001; 95% confidence interval, CI [0.600%-2.226%]; AF: 1.19% ± 0.32%, P < 0.001; CI [0.560%-1.822%]) by comparing the differences of the means. Pooled nondegenerative IVDs (Pfirrmann 1 and 2) had significantly lower gagCEST effects in patients suffering from SpA compared with healthy controls in NP (P < 0.001; CI [1.176%-2.337%]) and AF (P < 0.001; CI [0.858%-1.779%]). No significant difference of MTRasym values was found in degenerative IVDs between patients and controls in NP (P = 0.204; CI [-0.504%-2.170%]). CONCLUSION: GagCEST analysis of morphologically nondegenerative IVDs (Pfirrmann score 1 and 2) in T2 w images demonstrated significantly lower GAG values in patients with spondyloarthritis in NP and AF, possibly representing a depletion of GAG in spondyloarthritis in the absence of morphologic degeneration.


Assuntos
Glicosaminoglicanos/metabolismo , Disco Intervertebral/metabolismo , Vértebras Lombares/metabolismo , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Espondilartrite/metabolismo , Adulto , Idoso , Algoritmos , Biomarcadores/metabolismo , Feminino , Humanos , Disco Intervertebral/patologia , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espondilartrite/patologia
20.
J Comput Assist Tomogr ; 39(1): 64-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25340588

RESUMO

OBJECTIVE: The objective of this study was to investigate the correlation between semiquantitative and quantitative dynamic contrast-enhanced (DCE) parameters with delayed gadolinium-enhanced magnetic resonance imaging (MRI) of the cartilage (dGEMRIC). METHODS: Fifteen patients with early rheumatoid arthritis (RA) from the ArthroMark cohort were investigated at a 3-T MRI scanner. The metacarpophalangeal (MCP) joint of the index finger was examined with DCE-MRI and dGEMRIC. Semiquantitative and quantitative DCE perfusion parameters were calculated. The RA MRI score of the second MCP joint and the joint space width were measured. RESULTS: Significant correlations were noted between both semiquantitative and quantitative DCE parameters and the RA MRI score of the second MCP joint. There was a significant negative correlation between DCE parameters and dGEMRIC. No association between joint space width and DCE parameters was observed. CONCLUSIONS: Semiquantitative and quantitative analyses of perfusion are applicable to show that cartilage damage correlates with the inflammation activity despite the absence of joint space narrowing.


Assuntos
Artrite Reumatoide/diagnóstico , Cartilagem/patologia , Gadolínio DTPA , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Articulação Metacarpofalângica/patologia , Osteocondrite/patologia , Algoritmos , Artrite Reumatoide/etiologia , Artrite Reumatoide/metabolismo , Meios de Contraste/administração & dosagem , Meios de Contraste/farmacocinética , Diagnóstico Precoce , Feminino , Gadolínio DTPA/farmacocinética , Humanos , Aumento da Imagem/métodos , Masculino , Articulação Metacarpofalângica/metabolismo , Pessoa de Meia-Idade , Variações Dependentes do Observador , Osteocondrite/complicações , Osteocondrite/metabolismo , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa