Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 51(6): 1713-1724, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38216779

RESUMO

PURPOSE: Enzymolysis clearance strategy, characterized by releasing the non-reabsorbable radioactive fragment under the specific cleavage of enzymes, is confirmed to be a safe and effective way to reduce the renal radioactivity accumulation in mice. However, the effectiveness of this strategy in humans remains unknown. Human epidermal growth factor receptor 2 (HER2) is overexpressed in various types of tumors, and radiolabeled HER2 Affibody is believed to be an attractive tool for HER2-targeted theranostics. However, its wide application is limited by the high and persistent renal uptake. In this study, we intend to validate the effectiveness of enzymolysis clearance strategy in reducing renal accumulation by using a modified HER2 Affibody. MATERIALS AND METHODS: A new HER2 Affibody ligand, NOTA-MVK-ZHER2:2891, containing a cleavable Met-Val-Lys (MVK) linker was synthesized and labeled with 68Ga. The microPET imaging study was performed in SKOV-3 tumor mice to assess the uptakes of the control ligand and the MVK one in tumors and kidneys. Seven healthy volunteers were included for biodistribution and dosimetric studies with both the control and MVK ligands performed 1 week apart. Urine and blood samples from healthy volunteers were collected for in vivo metabolism study of the two ligands. Four HER2-positive and two HER2-negative patients were recruited for [68Ga]Ga-NOTA-MVK-ZHER2:2891 PET/CT imaging at 2 and 4 h post-injection (p.i.). RESULTS: [68Ga]Ga-NOTA-MVK-ZHER2:2891 was stable both in PBS and in mouse serum. MicroPET images showed that the tumor uptake of [68Ga]Ga-NOTA-MVK-ZHER2:2891 was comparable to that of [68Ga]Ga-NOTA-ZHER2:2891 at all the time points, while the kidney uptake was significantly reduced 40 min p.i. (P < 0.05). The biodistribution study in healthy volunteers showed that the kidney uptake of MVK ligand was significantly lower than that of the control ligand at 1 h p.i. (P < 0.05), with the SUVmean of 34.3 and 45.8, respectively, while the uptakes of the two ligands in the other organs showed negligible difference. The effective doses of the MVK ligand and the control one were 26.1 and 28.7 µSv/MBq, respectively. The enzymolysis fragment of [68Ga]Ga-NOTA-Met-OH was observed in the urine samples of healthy volunteers injected with the MVK ligand, indicating that the enzymolysis clearance strategy worked in humans. The PET/CT study of patients showed that the range of SUVmax of HER2-positive lesions was 9.4-21, while that of HER2-negative lesions was 2.7-6.2, which suggested that the MVK modification did not affect the ability of ZHER2:2891 structure to bind with HER2. CONCLUSION: We for the first time demonstrated that enzymolysis clearance strategy can effectively reduce renal radioactivity accumulation in humans. This strategy is expected to decrease renal radiation dose of peptide and small protein-based radiotracers, especially in the field of radionuclide therapy.


Assuntos
Radioisótopos de Gálio , Rim , Neoplasias , Receptor ErbB-2 , Animais , Feminino , Humanos , Camundongos , Linhagem Celular Tumoral , Rim/metabolismo , Rim/efeitos da radiação , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Compostos Radiofarmacêuticos/química , Receptor ErbB-2/metabolismo , Proteínas Recombinantes de Fusão/farmacocinética , Distribuição Tecidual , Neoplasias/diagnóstico por imagem , Neoplasias/genética
2.
CNS Neurosci Ther ; 30(6): e14787, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38894559

RESUMO

AIMS: The patient being minimally conscious state (MCS) may benefit from wake-up interventions aimed at improving quality of life and have a higher probability of recovering higher level of consciousness compared to patients with the unresponsive wakefulness syndrome (UWS). However, differentiation of the MCS and UWS poses challenge in clinical practice. This study aimed to explore glucose metabolic pattern (GMP) obtained from 18F-labeled-fluorodeoxyglucose positron emission tomography (18F-FDG-PET) in distinguishing between UWS and MCS. METHODS: Fifty-seven patients with disorders of consciousness (21 cases of UWS and 36 cases of MCS) who had undergone repeated standardized Coma Recovery Scale-Revised (CRS-R) evaluations were enrolled in this prospective study. 18F-FDG-PET was carried out in all patients and healthy controls (HCs). Voxel-based scaled subprofile model/principal component analysis (SSM/PCA) was used to generate GMPs. The expression score of whole-brain GMP was obtained, and its diagnostic accuracy was compared with the standardized uptake value ratio (SUVR). The diagnostic efficiency was validated by one-year later clinical outcomes. RESULTS: UWS-MCS GMP exhibited hypometabolism in the frontal-parietal cortex, along with hypermetabolism in the unilateral lentiform nucleus, putamen, and anterior cingulate gyrus. The UWS-MCS-GMP expression score was significantly higher in UWS compared to MCS patients (0.90 ± 0.85 vs. 0 ± 0.93, p < 0.001). UWS-MCS-GMP expression score achieved an area under the curve (AUC) of 0.77 to distinguish MCS from UWS, surpassing that of SUVR based on the frontoparietal cortex (AUC = 0.623). UWS-MCS-GMP expression score was significantly correlated with the CRS-R score (r = -0.45, p = 0.004) and accurately predicted the one-year outcome in 73.7% of patients. CONCLUSION: UWS and MCS exhibit specific glucose metabolism patterns, the UWS-MCS-GMP expression score significantly distinguishes MCS from UWS, making SSM/PCA a potential diagnostic methods in clinical practice for individual patients.


Assuntos
Encéfalo , Fluordesoxiglucose F18 , Glucose , Estado Vegetativo Persistente , Tomografia por Emissão de Pósitrons , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Glucose/metabolismo , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Estado Vegetativo Persistente/metabolismo , Estado Vegetativo Persistente/diagnóstico por imagem , Idoso , Estudos Prospectivos , Adulto Jovem
3.
J Nucl Med ; 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38388513

RESUMO

The uMI Panorama is a novel PET/CT system using silicon photomultiplier and application-specific integrated circuit technologies and providing exceptional spatial and time-of-flight (TOF) resolutions. The objective of this study was to assess the physical performance of the uMI Panorama in accordance with the National Electrical Manufacturers Association (NEMA) NU 2-2018 standard. Methods: Spatial resolution, sensitivity, count rate performance, accuracy, image quality, and TOF resolution were evaluated in accordance with the guidelines outlined in the NEMA NU 2-2018 standard. Energy resolution was determined using the same dataset acquired for the count rate performance evaluation. Images from a Hoffman brain phantom, a mini-Derenzo phantom, and 3 patient studies were evaluated to demonstrate system performance. Results: The transaxial spatial resolution at full width at half maximum was measured as 2.88 mm with a 1-cm offset from the center axial field of view. The sensitivity at the center axial field of view was 20.1 kcps/MBq. At an activity concentration of 73.0 kBq/mL, the peak noise-equivalent count rate (NECR) reached 576 kcps with a scatter fraction of approximately 33.2%. For activity concentrations at or below the peak NECR, the maximum relative count rate error among all slices remained consistently below 3%. When assessed using the NEMA image quality phantom, overall image contrast recovery ranged from 63.2% to 88.4%, whereas background variability ranged from 4.2% to 1.1%. TOF resolution was 189 ps at 5.3 kBq/mL and was consistently lower than 200 ps for activity concentrations at or below the peak NECR. The patient studies demonstrated that scans at 2 min/bed produced images characterized by low noise and high contrast. Clear delineation of nuclei, spinal cords, and other substructures of the brain was observed in the brain PET images. Conclusion: uMI Panorama, the world's first commercial PET system with sub-200-ps TOF resolution, demonstrated fine spatial and fast TOF resolutions, robust count rate performance, and high quantification accuracy across a wide range of activity levels. This advanced technology offers enhanced diagnostic capability for detecting small and low-contrast lesions while showing promising potential under high-count-rate imaging scenarios.

4.
J Nucl Med ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38991753

RESUMO

Brain PET imaging often faces challenges from head motion (HM), which can introduce artifacts and reduce image resolution, crucial in clinical settings for accurate treatment planning, diagnosis, and monitoring. United Imaging Healthcare has developed NeuroFocus, an HM correction (HMC) algorithm for the uMI Panorama PET/CT system, using a data-driven, statistics-based approach. The HMC algorithm automatically detects HM using a centroid-of-distribution technique, requiring no parameter adjustments. This study aimed to validate NeuroFocus and assess the prevalence of HM in clinical short-duration 18F-FDG scans. Methods: The study involved 317 patients undergoing brain PET scans, divided into 2 groups: 15 for HMC validation and 302 for evaluation. Validation involved patients undergoing 2 consecutive 3-min single-bed-position brain 18F-FDG scans-one with instructions to remain still and another with instructions to move substantially. The evaluation examined 302 clinical single-bed-position brain scans for patients with various neurologic diagnoses. Motion was categorized as small or large on the basis of a 5% SUV change in the frontal lobe after HMC. Percentage differences in SUVmean were reported across 11 brain regions. Results: The validation group displayed a large negative difference (-10.1%), with variation of 5.2% between no-HM and HM scans. After HMC, this difference decreased dramatically (-0.8%), with less variation (3.2%), indicating effective HMC application. In the evaluation group, 38 of 302 patients experienced large HM, showing a 10.9% ± 8.9% SUV increase after HMC, whereas most exhibited minimal uptake changes (0.1% ± 1.3%). The HMC algorithm not only enhanced the image resolution and contrast but also aided in disease identification and reduced the need for repeat scans, potentially optimizing clinical workflows. Conclusion: The study confirmed the effectiveness of NeuroFocus in managing HM in short clinical 18F-FDG studies on the uMI Panorama PET/CT system. It found that approximately 12% of scans required HMC, establishing HMC as a reliable tool for clinical brain 18F-FDG studies.

5.
J Nucl Med ; 64(12): 1880-1888, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37827842

RESUMO

Kirsten rat sarcoma (KRAS) mutations are an important marker for tumor-targeted therapy. In this study, we sought to develop a KRASG12C oncoprotein-targeted PET tracer and to evaluate its translational potential for noninvasive imaging of the KRASG12C mutation in non-small cell lung cancer (NSCLC) and colorectal cancer (CRC) patients. Methods: [18F]PFPMD was synthesized on the basis of AMG510 (sotorasib) by attaching a polyethylene glycol chain to the quinazolinone structure. The binding selectivity and imaging potential of [18F]PFPMD were verified by cellular uptake, internalization, and blocking (H358: KRASG12C mutation; A549: non-KRASG12C mutation) studies, as well as by a small-animal PET/CT imaging study on tumor-bearing mice. Five healthy volunteers were enrolled to assess the safety, biodistribution, and dosimetry of [18F]PFPMD. Subsequently, 14 NSCLC or CRC patients with or without the KRASG12C mutation underwent [18F]PFPMD and [18F]FDG PET/CT imaging. The SUVmax of tumor uptake of [18F]PFPMD was measured and compared between patients with and without the KRASG12C mutation. Results: [18F]PFPMD was obtained with a high radiochemical yield, radiochemical purity, and stability. The protein-binding assay showed that [18F]PFPMD selectively binds to the KRASG12C protein. [18F]PFPMD uptake was significantly higher in H358 than in A549 and was decreased by pretreatment with AMG510 (H358 vs. A549: 3.22% ± 0.28% vs. 2.50% ± 0.25%, P < 0.05; block: 2.06% ± 0.13%, P < 0.01). Similar results were observed in tumor-bearing mice on PET imaging (H358 vs. A549: 3.93% ± 0.24% vs. 2.47% ± 0.26% injected dose/g, P < 0.01; block: 2.89% ± 0.29% injected dose/g; P < 0.05). [18F]PFPMD was safe in humans and was excreted primarily by the gallbladder and intestines. The whole-body effective dose was comparable to that of [18F]FDG. The accumulation of [18F]PFPMD in KRASG12C mutation tumors was significantly higher than that in non-KRASG12C mutation tumors (SUVmax: 3.73 ± 0.58 vs. 2.39 ± 0.22, P < 0.01) in NSCLC and CRC patients. Conclusion: [18F]PFPMD is a safe and promising PET tracer for noninvasive screening of the KRASG12C mutation status in NSCLC and CRC patients.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Colorretais , Neoplasias Pulmonares , Humanos , Animais , Camundongos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Proteínas Proto-Oncogênicas p21(ras)/genética , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/tratamento farmacológico , Fluordesoxiglucose F18/uso terapêutico , Distribuição Tecidual , Tomografia por Emissão de Pósitrons , Mutação , Pulmão/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/genética
6.
Mol Imaging Biol ; 25(5): 857-866, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37407745

RESUMO

PURPOSE: This study aims to compare the diagnostic efficacy of 68Ga-FAPI-04 PET and 18F-FDG PET for detecting anastomotic recurrence in postoperative patients with gastrointestinal cancer, and to characterize the signal pattern over time at surgical wounds on both PET imaging. METHODS: Gastrointestinal cancer patients who planned to 68Ga-FAPI-04 and 18F-FDG PET/CT imaging for postoperative surveillance were involved. The SUVmax at surgical wounds were assessed. Endoscopic pathology confirmed anastomotic recurrence or it was ruled out by imaging and clinical follow-up. The sensitivity, specificity, positive and negative predictive values (PPV and NPV), and accuracy of the two PET imaging in detecting anastomotic recurrence were compared. Relationships between tracer uptake at surgical wounds and postoperative time were also analyzed. RESULTS: Compared with non-recurrent patients, the recurrent patients exhibited a significantly higher anastomotic SUVmax on 68Ga-FAPI-04 PET (SUVmax: 9.92 ± 4.36 vs. 2.81 ± 1.86, P = 0.002). Sensitivity, specificity, PPV, NPV, and accuracy of detecting anastomotic recurrence were 100.0%, 87.3%, 41.7%, 100.0%, and 88.3% for 68Ga-FAPI-04 PET, and 60.0%, 81.8%, 23.1%, 95.7%, and 80.0% for 18F-FDG PET, respectively. Although 68Ga-FAPI-04 PET signal at surgical wounds showed a slight trend to decrease with time, no statistical difference was observed over months post-surgery (P > 0.05). CONCLUSIONS: Both tracers displayed high NPVs in identifying anastomotic recurrence with a higher sensitivity to 68Ga-FAPI-04. Tracer uptake at anastomotic sites does not decrease significantly over time, which results in low PPVs for both PET. Therefore, it is difficult to differentiate anastomotic recurrence from inflammation on either PET imaging.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa