Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Vascular ; 30(2): 392-402, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33813971

RESUMO

OBJECTIVES: Swine (Sus Scrofa) are utilized broadly in research settings, given similarities to human vessel size and function; however, there are some important differences for clinicians to understand in order to interpret and perform translational research. This review article uses angiograms acquired in the course of a translational research program to present a description of the functional anatomy of the swine. METHODS: Digital subtraction angiography and computed tomography angiography were obtained throughout the course of multiple studies utilizing power injection with iodinated contrast. Subtracted two-dimensional images and three-dimensional multiplanar reformations were utilized post image acquisition to create maximal intensity projections and three-dimensional renderings of using open-source software (OsiriX). These imaging data are presented along with vessel measurements for reference. RESULTS: An atlas highlighting swine vascular anatomy, with an emphasis on inter-species differences that may influence how studies are conducted and interpreted, was compiled. CONCLUSIONS: Swine are utilized in broad-reaching fields for preclinical research. While many similarities between human and swine vasculature exist, there are important differences to consider when conducting and interpreting research. This review article highlights these differences and presents accompanying images to inform clinicians gaining experience in swine research.


Assuntos
Meios de Contraste , Tomografia Computadorizada por Raios X , Angiografia Digital/métodos , Humanos , Imageamento Tridimensional/métodos , Suínos , Tomografia Computadorizada por Raios X/métodos
2.
J Surg Res ; 267: 82-90, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34139394

RESUMO

BACKGROUND: Patterns of utilization of the hybrid operating room (hybrid-OR) in trauma have not been described. The aim of this study was to describe the sequencing and integration of endovascular and operative interventions in trauma using a hybrid-OR. MATERIALS AND METHODS: This is a single-center, retrospective cohort study of trauma patients who underwent both endovascular and operative intervention (2013-2019). Patients were separated into four groups based on procedure patterns: concomitant-linked (C-L), concomitant-independent, serial-linked (S-L) and serial-independent (S-I). The groups were defined as follows: C-L - related endovascular and operative interventions in the same OR; concomitant-independent - unrelated interventions in the same OR; S-L - related interventions in separate ORs; S-I - unrelated interventions in separate ORs. Patient characteristics, procedures performed and time to angiography in each group were analyzed. RESULTS: Out of 202 patients, most procedures utilizing the hybrid-OR were for hemorrhage control (84.1%) and were performed in a C-L manner (36.1%). Patients in the C-L group were most likely to undergo lower extremity revascularization and received the most transfusions. Patients in the S-L and S-I groups were more severely injured, had greater severe abdominal injury and were more likely to undergo damage control surgery and solid organ interventions, respectively. The C-L group had the highest percentage of patients to undergo angiography within 12 h (77%, P = 0.053). CONCLUSION: The hybrid-OR is an ideal space for hemorrhage control in trauma, but there is room for improvement in the triage of patients with non-compressible torso hemorrhage. Current practice patterns prioritize the hybrid-OR for management of lower extremity injury and are not optimal. Use of the hybrid-OR could be improved by concomitant management of patients with severe abdominal injury requiring damage control surgery.


Assuntos
Traumatismos Abdominais , Procedimentos Endovasculares , Ferimentos e Lesões , Angiografia , Hemorragia/etiologia , Hemorragia/cirurgia , Humanos , Salas Cirúrgicas , Estudos Retrospectivos , Ferimentos e Lesões/cirurgia
3.
Vascular ; 29(1): 54-60, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32605533

RESUMO

OBJECTIVES: Mesenteric vascular disease carries a high risk of mortality and morbidity; however, due to obscure clinical presentation, it can be under-recognized. Currently, epidemiology of mesenteric vascular disease remains poorly defined. The aim of this study is to analyze changes in Scottish mortality rates from mesenteric vascular disease overtime. METHODS: This is a retrospective, longitudinal population-based cohort study using data extracted from death certificates and Scottish Index of Multiple Deprivation. All deaths related to a vascular disorder of the intestines recorded as an underlying cause of death between 1979 and 2014 were identified using International Classification of Disease-9 or International Classification of Disease-10 code groups. Data included demographics and location of death. The residence postcodes were used to classify socio-economic status using the Scottish Index of Multiple Deprivation. RESULTS: From 2,142,921 deaths over 36 years, 14,530 (0.7%) were due to mesenteric vascular disease with a median (interquartile range) age of 77 and a 2:1 female to male gender ratio. The mean ± standard deviation age significantly increased from 72.6 ± 12.1 in 1979 to 76.8 ± 11.1 in 2014 (p < 0.001, R2 = 0.772). Males were consistently younger than females at the time of death. The two lowest Scottish Index of Multiple Deprivation categories accounted for half of the cohort, throughout the study period (p = 0.068). The adjusted death rate per 100,000 population increased from 7.6 in 1979 to 12.1 in 2014. CONCLUSIONS: The reported death rates of mesenteric vascular disease in Scotland between 1979 and 2014 have nearly doubled. Mesenteric vascular disease affects twice as many women as men and is associated with social deprivation. The increased reporting of mesenteric vascular disease is likely due to increased recognition and incidence. These implications should be considered when planning healthcare provision in Scotland.


Assuntos
Artérias Mesentéricas , Isquemia Mesentérica/mortalidade , Oclusão Vascular Mesentérica/mortalidade , Veias Mesentéricas , Idoso , Idoso de 80 Anos ou mais , Causas de Morte/tendências , Feminino , Humanos , Incidência , Estudos Longitudinais , Masculino , Artérias Mesentéricas/diagnóstico por imagem , Isquemia Mesentérica/diagnóstico por imagem , Oclusão Vascular Mesentérica/diagnóstico por imagem , Veias Mesentéricas/diagnóstico por imagem , Pessoa de Meia-Idade , Características de Residência , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Escócia/epidemiologia , Determinantes Sociais da Saúde , Fatores Socioeconômicos , Fatores de Tempo
4.
J Vasc Surg ; 71(5): 1564-1571, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31611111

RESUMO

OBJECTIVE: Endovascular techniques in trauma surgery are becoming increasingly important in patient management, with procedures such as pelvic and splenic angioembolization becoming the standard of care for certain injuries. Traditionally, such interventions are performed via femoral access, although the morbidity of this approach is not insignificant (3%-10%). Transradial access (TRA) is an attractive alternative, pioneered by cardiologists, with low rates of access site complications in patients undergoing coronary intervention. Recently, this technology has extended to other interventions. The aim of this study was to present the initial experience of a radial program in a busy trauma center, with specific regard to safety and complications. METHODS: The medical records of trauma patients undergoing endovascular procedures via TRA between March 2018 and December 2018 were queried for procedural and postoperative data. Demography and injury characteristics were presented for the overall cohort, followed by a comparison of procedural data and complications between laterality. Continuous variables were compared using a two-tailed t-test and categorical variables were compared using a χ2 test. RESULTS: Over a 9-month period, 65 patients underwent 81 interventions via TRA, most commonly solid organ or pelvic angiography/embolization. Radial artery access was achieved in all patients, with procedural success achieved in all but two patients (n = 63 [96.9%]) who had hypoplastic radial artery anatomy, who underwent ulnar access. The overall technique-related complication rate was 1.5% with no difference observed between laterality (n = 1; P = .523). One patient with an admission Glasgow Coma Score of 3 and coagulopathy developed radial artery thrombosis after pelvic angiography via right TRA. Mortality was seen in seven patients (10.8%) owing to hemorrhagic shock (n = 3 [42.8%]) or multiorgan failure (n = 4 [57.1%]). There were no cases of postprocedural access site bleeding, hematoma, pseudoaneurysm, vascular injury, intraoperative arrhythmia or cerebrovascular accident, arteriovenous fistula formation, or infection. CONCLUSIONS: TRA is a feasible and low-risk alternative for endovascular intervention in the trauma patient. It yields good technical success with low morbidity. Although larger studies are needed to establish the full efficacy of TRA at the multi-institutional level, this single-institution study demonstrates the legitimacy of an alternative means for endovascular intervention in the trauma patient.


Assuntos
Cateterismo Periférico , Procedimentos Endovasculares , Artéria Radial , Ferimentos e Lesões/terapia , Adulto , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Clin Transplant ; 34(5): e13846, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32096878

RESUMO

BACKGROUND: The presence of a lower limb arteriovenous graft (LL-AVG) is indicative of a group of complex hemodialysis patients who have precarious long-term vascular access. The aim of this study is to describe our experience of the clinical decisions and interactions between LL-AVG and renal transplantation. METHODS: The records of 23 patients who received a transplant in the presence of a LL-AVG between 2010 and 2018 were analyzed: firstly, to determine whether patients with a LL-AVG received extended criteria transplants, the implantation procedure, and the management of the LL-AVG in the post-operative period. RESULTS: Seventeen patients (74%) had "end-stage access" and were thus considered for all offer stratified by the kidney donor profile index (KDPI) and donor type (DBD or DCD). In eleven patients (48%), a kidney with a high risk of delayed graft function was transplanted. Same-sided renal transplantation occurred in only 35% of cases, and of these, only one LL-AVG was ligated immediately to improve transplant perfusion. CONCLUSION: A patient-based approach applied in decision-making on management of the LL-AVG post-transplantation should include (a) the likelihood of delayed graft function, (b) the need for post-operative hemodialysis, (c) the side of proposed transplant compared to the LL-AVG, and (d) local complications.


Assuntos
Derivação Arteriovenosa Cirúrgica , Transplante de Rim , Diálise Renal , Implante de Prótese Vascular , Humanos , Transplante de Rim/efeitos adversos , Extremidade Inferior , Período Perioperatório , Estudos Retrospectivos , Doadores de Tecidos , Resultado do Tratamento
6.
Eur J Vasc Endovasc Surg ; 59(3): 472-479, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31865031

RESUMO

OBJECTIVE: The study compared transradial access (TRA) and transfemoral access (TFA) for splenic angio-embolisation (SAE), with a focus on technical success, intra-operative adjuncts, and complications. METHODS: This was a retrospective comparative study of all trauma patients undergoing SAE by TRA or TFA between February 2015 and February 2019 at a single institution. The medical records were queried for procedural and post-operative data, with comparisons made based on access site. Continuous variables were compared using a two tailed t test and categorical variables were compared using a chi square test. RESULTS: Over a four year period, there were 47 cases of SAE via TRA and 127 via TFA. Technical success was 95.7% during TRA and 98.4% during TFA (p = .30). Technical failures were a result of failed splenic artery cannulation after successful radial or femoral access. Time to splenic cannulation was shorter in the TRA group (19 min vs. 30 min; p = .008). Two or fewer catheters were used during TRA, whereas more than two catheters were needed during TFA (p < .001). There were no statistically significant differences in procedure length, fluoroscopy time, radiation dose, or contrast volume between groups. Nine patients (5.2%) developed access related complications, all in the TFA group (p = .12). Mortality rate was 2.3% (n = 4), with no statistical significance between groups (p = .71). CONCLUSION: While TFA is the conventional strategy for SAE, TRA is a safe and efficacious modality for SAE in trauma patients. Although larger studies are needed to establish the full efficacy of TRA for SAE at the multi-institutional level, this single centre study demonstrates the legitimacy of an alternative means for SAE in the trauma population.


Assuntos
Cateterismo Periférico , Embolização Terapêutica , Artéria Femoral , Artéria Radial , Artéria Esplênica , Ferimentos e Lesões/terapia , Adulto , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Artéria Radial/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Artéria Esplênica/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/mortalidade
7.
Vascular ; 28(5): 612-618, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32356682

RESUMO

OBJECTIVES: Resuscitative endovascular balloon occlusion of the aorta is an alternative to resuscitative thoracotomy in non-compressible torso haemorrhage. Low-profile, compliant balloon catheter systems have been developed, which can be deployed without the need for fluoroscopy. However, concern exists for over inflation and aortic injury, especially as compliant balloon material can stretch reducing syringe feedback and limiting the effectiveness of a safety valve. An alternative material would be a semi-compliant balloon material, but its performance is unknown. The aim of this study was to compare the inflation characteristics of compliant versus semi-compliant balloon systems and to determine whether a pressure relief safety valve can be practically applied to a semi-compliant balloon catheter as a safety device. METHODS: This was an ex vivo study using porcine segments of thoracic aorta. The study consisted of two phases. The first phase involved intermittent inflation of six compliant balloon and six semi-compliant balloon balloons until balloon or aortic rupture. In the second phase, six semi-compliant balloons with the pressure-relief valve set at 0.45 atmospheres were inflated in the aortas until the valve release, followed by injection with additional 30 mL. Data including pressure, volume, balloon working length, diameter and circumferential stretch ratio were collected. RESULTS: At failure, mean balloon volume was almost double in compliant balloon group vs semi-compliant balloon group - 49.83 mL (±23.25) and 25.16 mL (±8.93), respectively (p = 0.004), with 36% increase in working length in the compliant balloon group - 81.17 mm (±19.11) vs 59.49 (±4.86) for semi-compliant balloon (p = 0.023). When plotted, the relationship pattern between volume and pressure fit a linear model for the compliant balloon, and a quadratic model for the semi-compliant balloon. Following attempted over inflation with the pressure valve, there was no change in parameters before and after attempted over inflation. CONCLUSIONS: The inflation profile differs between balloon designs. In contrast to semi-compliant balloons, compliant balloons will accommodate more volume to mitigate increase in pressure. This does not completely eliminate the risk of over inflation. The inflation characteristics of the semi-compliant balloon permit pairing it with a safety valve, which could lead to a development of a safer balloon technology in the future.


Assuntos
Aorta Torácica , Oclusão com Balão/instrumentação , Procedimentos Endovasculares/instrumentação , Dispositivos de Acesso Vascular , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Pressão , Sus scrofa
8.
Ann Surg ; 270(4): 612-619, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31356265

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of a recently active endovascular trauma service (ETS) on case volume and time to hemostasis, as a complement to an existing interventional radiology (IR) service. SUMMARY BACKGROUND DATA: Endovascular techniques are vital for trauma care, but timely access can be a challenge. There is a paucity of data on the effect of a multispecialty team for delivery of endovascular hemorrhage control. METHODS: The electronic medical record of trauma patients undergoing endovascular procedures between 2013 and 2018 was queried for provider type (IR or ETS). Case volume and rates were expressed per 100 monthly admissions, normalizing for seasonal variation. Interrupted time series analysis was used to model the case rate pre- and post-introduction of the ETS. Admission-to-procedure-time data were collected for pelvic angioembolization as a marker of patients requiring emergency hemostasis. RESULTS: During 6 years, 1274 admission episodes required endovascular interventions. Overall case volume increased from 2.7 to 3.6 at a rate of 0.006 (P = 0.734) after introduction of the ETS. IR case volume decreased from 3.3 to 2.6 at a rate of 0.03 (P = 0.063). ETS case volume increased at a rate of 0.048 (P < 0.001), which was significantly different from the IR trend (P < 0.001). Median (interquartile range) time-to-procedure (hours) was significantly shorter for pelvic angioembolization [3.0 (4.4) vs 4.3 (3.6); P < 0.001] when ETS was compared to IR. CONCLUSION: A surgical ETS increases case volume and decreases time to hemostasis for trauma patients requiring time sensitive interventions. Further work is required to assess patient outcome following this change.


Assuntos
Serviço Hospitalar de Emergência , Procedimentos Endovasculares , Hemorragia/cirurgia , Hemostase Endoscópica/métodos , Tempo para o Tratamento/estatística & dados numéricos , Ferimentos e Lesões/complicações , Adulto , Feminino , Hemorragia/etiologia , Humanos , Análise de Séries Temporais Interrompida , Masculino , Maryland , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Estudos Retrospectivos
9.
Anesth Analg ; 129(6): 1482-1491, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31743167

RESUMO

BACKGROUND: Acute traumatic coagulopathy is common in trauma patients. Prompt diagnosis of hypofibrinogenemia allows for early treatment with cryoprecipitate or fibrinogen concentrate. At present, optimal cutoffs for diagnosing hypofibrinogenemia with kaolin thrombelastography (TEG) have not been established. We hypothesized that kaolin kaolin-TEG parameters, such as kinetic time (K-time), α-angle, and maximum amplitude (MA), would accurately diagnose hypofibrinogenemia (fibrinogen <200 mg/dL) and severe hypofibrinogenemia (fibrinogen <100 mg/dL). METHODS: Adult trauma patients (injury severity score >15) presenting to our trauma center between October 2015 and October 2017 were identified retrospectively. All patients had a traditional plasma fibrinogen measurement and kaolin-TEG performed within 15 minutes of each other and within 1 hour of admission. Some patients had additional measurements after. Receiver operating characteristic (ROC) curve analysis was performed to evaluate whether K-time, α-angle, and MA could diagnose hypofibrinogenemia and severe hypofibrinogenemia. Area under the ROC curve (AUROC) was calculated for each TEG parameter with a bootstrapped 99% confidence interval (CI). Further, ROC analysis was used to estimate ideal cutoffs for diagnosing hypofibrinogenemia and severe hypofibrinogenemia by maximizing sensitivity and specificity. In addition, likelihood ratios were also calculated for different TEG variable cutoffs to diagnose hypofibrinogenemia and severe hypofibrinogenemia. RESULTS: Seven hundred twenty-two pairs of TEGs and traditional plasma fibrinogen measurements were performed in 623 patients with 99 patients having additional pairs of tests after the first hour. MA (AUROC = 0.84) and K-time (AUROC = 0.83) better diagnosed hypofibrinogenemia than α-angle (AUROC = 0.8; P = .03 and P < .001 for AUROC comparisons, respectively). AUROCs statistically improved for each parameter when severe hypofibrinogenemia was modeled as the outcome (P < .001). No differences were found between parameters for diagnosing severe hypofibrinogenemia (P > .05 for all comparisons). The estimated optimal cutoffs for diagnosing hypofibrinogenemia were 1.5 minutes for K-time (95% CI, 1.4-1.6), 70.0° for α-angle (95% CI, 69.8-71.0), and 60.9 mm for MA (95% CI, 59.2-61.8). The estimated optimal cutoffs for diagnosing severe hypofibrinogenemia were 2.4 minutes for K-time (95% CI, 1.7-2.8), 60.6° for α-angle (95% CI, 57.2-67.3), and 51.2 mm for MA (95% CI, 49.0-56.2). Currently recommended K-time and α-angle cutoffs from the American College of Surgeons had low sensitivity for diagnosing hypofibrinogenemia (3%-29%), but sensitivity improved to 74% when using optimal cutoffs. CONCLUSIONS: Kaolin-TEG parameters can accurately diagnose hypofibrinogenemia and severe hypofibrinogenemia in trauma patients. Currently recommended cutoffs for the treatment of hypofibrinogenemia are skewed toward high specificity and low sensitivity. Many patients are likely to be undertreated for hypofibrinogenemia using current national guidelines.


Assuntos
Afibrinogenemia/diagnóstico , Afibrinogenemia/terapia , Coagulação Sanguínea , Fibrinogênio/análise , Ressuscitação , Tromboelastografia , Ferimentos e Lesões/diagnóstico , Ferimentos e Lesões/terapia , Adulto , Afibrinogenemia/sangue , Afibrinogenemia/complicações , Biomarcadores/sangue , Tomada de Decisão Clínica , Diagnóstico Precoce , Feminino , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Ferimentos e Lesões/sangue , Ferimentos e Lesões/complicações , Adulto Jovem
10.
J Artif Organs ; 22(2): 141-145, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30406438

RESUMO

Central venous catheters (CVC) remain a mainstay of vascular access particularly for incident patients,but lead to central vein stenosis (CVS) in up to 1 in 6 patents. This often leads to establishing dialysis access in the groin which in turn may result in development of CVS in the lower body, although this is poorly reported. The HeRO device was designed to address CVS by bypassing the stenosed veins with a nitinol-reinforced silicone tube into the right atrium, which acts as an outflow conduit attached to an arterial inflow. The efficacy and safety of the HeRO device in the upper limb is well established, but there is no data on its use in the lower limb. We describe 2 cases of HeRO in the lower limb, one primary and one secondary, which remain in use. Lower limb HeRO is feasible in the lower limb and can work well either as de novo (to achieve vascular access) or as a salvage procedure (to maintain vascular access).


Assuntos
Derivação Arteriovenosa Cirúrgica/instrumentação , Cateteres Venosos Centrais , Diálise Renal/instrumentação , Adulto , Feminino , Humanos , Extremidade Inferior , Masculino , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
Surg Innov ; 24(2): 145-150, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28134003

RESUMO

INTRODUCTION: Liver surgery is widely used as a treatment modality for various liver pathologies. Despite significant improvement in clinical care, operative strategies, and technology over the past few decades, liver surgery is still risky, and optimal preoperative planning and anatomical assessment are necessary to minimize risks of serious complications. 3D printing technology is rapidly expanding, and whilst appliactions in medicine are growing, but its applications in liver surgery are still limited. This article describes the development of models of hepatic structures specific to a patient diagnosed with an operable hepatic malignancy. METHODS: Anatomy data were segmented and extracted from computed tomography and magnetic resonance imaging of the liver of a single patient with a resectable liver tumor. The digital data of the extracted anatomical surfaces was then edited and smoothed, resulting in a set of digital 3D models of the hepatic vein, portal vein with tumor, biliary tree with gallbladder, and hepatic artery. These were then 3D printed. RESULTS: The final models of the liver structures and tumor provided good anatomical detail and representation of the spatial relationships between the liver tumor and adjacent hepatic structures and could be easily manipulated and explored from different angles. CONCLUSIONS: A graspable, patient-specific, 3D printed model of liver structures could provide an improved understanding of the complex liver anatomy and better navigation in difficult areas and allow surgeons to anticipate anatomical issues that might arise during the operation. Further research into adequate imaging, liver-specific volumetric software, and segmentation algorithms are worth considering to optimize this application.


Assuntos
Hepatectomia/métodos , Imageamento Tridimensional/métodos , Fígado , Medicina de Precisão/métodos , Impressão Tridimensional , Hepatectomia/educação , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Modelos Anatômicos , Tomografia Computadorizada por Raios X
12.
J Vasc Surg ; 73(2): 736-737, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33485497
13.
J Vasc Surg ; 73(2): 741-742, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33485504
15.
Eur J Trauma Emerg Surg ; 48(1): 299-305, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33399878

RESUMO

PURPOSE: Resuscitative endovascular balloon occlusion of the aorta (REBOA) is used to temporize patients with infradiaphragmatic hemorrhage. Current guidelines advise < 30 min, to avoid ischemia/ reperfusion injury, whenever possible. The technique of partial REBOA (P-REBOA) has been developed to minimize the effects of distal ischemia. This study presents our clinical experience with P-REBOA, comparing outcomes to complete occlusion (C-REBOA). PATIENTS AND METHODS: Retrospective analysis of patients' electronic data and local REBOA registry between January 2016 and May 2019. INCLUSION CRITERIA: adult trauma patients who received Zone I C-REBOA or P-REBOA for infradiaphragmatic hemorrhage, who underwent attempted exploration in the operating room. Comparison of outcomes based on REBOA technique (P-REBOA vs C-REBOA) and occlusion time (> 30 min, vs ≤ 30 min) RESULTS: 46 patients were included, with 14 treated with P-REBOA. There were no demographic differences between P-REBOA and C-REBOA. Prolonged (> 30 min) REBOA (regardless of type of occlusion) was associated with increased mortality (32% vs 0%, p = 0.044) and organ failure. When comparing prolonged P-REBOA with C-REBOA, there was a trend toward lower ventilator days [19 (11) vs 6 (9); p = 0.483] and dialysis (36.4% vs 16.7%; p = 0.228) with significantly less vasopressor requirement (72.7% vs 33.3%; p = 0.026). CONCLUSION: P-REBOA can be delivered in a clinical setting, but is not currently associated with improved survival in prolonged occlusion. In survivors, there is a trend toward lower organ support needs, suggesting that the technique might help to mitigate ischemic organ injury. More clinical data are needed to clarify the benefit of partial occlusion REBOA.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Adulto , Aorta , Estudos de Viabilidade , Humanos , Ressuscitação , Estudos Retrospectivos , Choque Hemorrágico/terapia , Centros de Traumatologia
16.
Front Physiol ; 13: 1033784, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36589436

RESUMO

Introduction: The relationship between coronary artery flow and left ventricular (LV) function during hemorrhagic shock remains unknown. The aim of this study was to quantify coronary artery flow directionality alongside left ventricular function through the four classes of hemorrhage shock. Methods: Following baseline data collection, swine were exsanguinated into cardiac arrest via the femoral artery using a logarithmic bleed, taking each animal through the four classes of hemorrhagic shock based on percent bleed (class I: 15%; class II: 15%-30%; class III: 30%-40%; class IV: >40%). Telemetry data, left ventricular pressure-volume loops, and left anterior descending artery flow tracings over numerous cardiac cycles were collected and analyzed for each animal throughout. Results: Five male swine (mean 72 ± 12 kg) were successfully exsanguinated into cardiac arrest. Mean left ventricular end-diastolic volume, end-diastolic pressure, and stroke work decreased as the hemorrhagic shock class progressed (p < 0.001). The proportion of diastole spent with retrograde coronary flow was also associated with class of hemorrhagic shock (mean 5.6% of diastole in baseline, to 63.9% of diastole in class IV; p < 0.0001), worsening at each class from baseline through class IV. Preload recruitable stroke work (PRSW) decreased significantly in classes II through IV (p < 0.001). Systemic Vascular Resistance (SVR) is associated with class of hemorrhage shock (p < 0.001). Conclusion: With progressive classes of hemorrhagic shock left ventricular function progressively decreased, and the coronary arteries spent a greater proportion of diastole in retrograde flow, with progressively more negative total coronary flow. Preload recruitable stroke work, a load-independent measure of inotropy, also worsened in severe hemorrhagic shock, indicating the mechanism extends beyond the drop in preload and afterload alone.

17.
Shock ; 57(6): 243-250, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35759304

RESUMO

INTRODUCTION: Selective aortic arch perfusion (SAAP) is an endovascular technique that consists of aortic occlusion with perfusion of the coronary and cerebral circulation. It been shown to facilitate return of spontaneous circulation (ROSC) after exanguination cardiac arrest (ECA), but it is not known how long arrest may last before the myocardium can no longer be durably recovered. The aim of this study is to assess the myocardial tolerance to exsanguination cardiac arrest before successful ROSC with SAAP. METHODS: Male adult swine (n = 24) were anesthetized, instrumented, and hemorrhaged to arrest. Animals were randomized into three groups: 5, 10, and 15 min of cardiac arrest before resuscitation with SAAP. Following ROSC, animals were observed for 60 min in a critical care environment. Primary outcomes were ROSC, and survival at 1-h post-ROSC. RESULTS: Shorter cardiac arrest time was associated with higher ROSC rate and better 1-h survival. ROSC was obtained for 100% (8/8) of the 5-min ECA group, 75% (6/8) of the 10-min group, 43% (3/7) of the 15-min group (P = 0.04). One-hour post-ROSC survival was 75%, 50%, and 14% in 5-, 10-, and 15-min groups, respectively (P = 0.02). One-hour survivors in the 5-min group required less norepinephrine (1.31 mg ±â€Š0.83 mg) compared with 10-SAAP (0.76 mg ±â€Š0.24 mg), P = 0.008. CONCLUSION: Whole blood SAAP can accomplish ROSC at high rates even after 10 min of unsupported cardiac arrest secondary to hemorrhage, with some viability beyond to 15 min. This is promising as a tool for ECA, but requires additional optimization and clinical trials.Animal Use Protocol, IACUC: 0919015.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Animais , Aorta Torácica , Reanimação Cardiopulmonar/métodos , Exsanguinação/complicações , Parada Cardíaca/tratamento farmacológico , Hemorragia/complicações , Masculino , Miocárdio , Perfusão/métodos , Suínos
18.
PLoS One ; 17(3): e0265778, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35324991

RESUMO

BACKGROUND: Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) is controversial as a hemorrhage control adjunct due to lack of data with a suitable control group. We aimed to determine outcomes of trauma patients in shock undergoing REBOA versus no-REBOA. METHODS: This single-center, retrospective, matched cohort study analyzed patients ≥16 years in hemorrhagic shock without cardiac arrest (2000-2019). REBOA (R; 2015-2019) patients were propensity matched 2:1 to historic (H; 2000-2012) and contemporary (C; 2013-2019) groups. In-hospital mortality and 30-day survival were analyzed using chi-squared and log rank testing, respectively. RESULTS: A total of 102,481 patients were included (R = 57, C = 88,545, H = 13,879). Propensity scores were assigned using age, race, mechanism, lowest systolic blood pressure, lowest Glasgow Coma Score (GCS), and body region Abbreviated Injury Scale scores to generate matched groups (R = 57, C = 114, H = 114). In-hospital mortality was significantly lower in the REBOA group (19.3%) compared to the contemporary (35.1%; p = 0.024) and historic (44.7%; p = 0.001) groups. 30-day survival was significantly higher in the REBOA versus no-REBOA groups. CONCLUSION: In a high-volume center where its use is part of a coordinated hemorrhage control strategy, REBOA is associated with improved survival in patients with noncompressible torso hemorrhage.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Aorta , Estudos de Coortes , Hemorragia/terapia , Humanos , Escala de Gravidade do Ferimento , Ressuscitação , Estudos Retrospectivos , Choque Hemorrágico/terapia
19.
Shock ; 55(3): 288-300, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32925603

RESUMO

ABSTRACT: The emerging concept of endovascular resuscitation applies catheter-based techniques in the management of patients in shock to manipulate physiology, optimize hemodynamics, and bridge to definitive care. These interventions hope to address an unmet need in the care of severely injured patients, or those with refractory non-traumatic cardiac arrest, who were previously deemed non-survivable. These evolving techniques include Resuscitative Endovascular Balloon Occlusion of Aorta, Selective Aortic Arch Perfusion, and Extracorporeal Membrane Oxygenation and there is a growing literature base behind them. This review presents the up-to-date techniques and interventions, along with their application, evidence base, and controversy within the new era of endovascular resuscitation.


Assuntos
Procedimentos Endovasculares , Ressuscitação/métodos , Choque/terapia , Procedimentos Endovasculares/métodos , Humanos
20.
Shock ; 55(1): 83-89, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33337788

RESUMO

ABSTRACT: Exsanguination leading to cardiac arrest is the terminal phase of uncontrolled hemorrhage. Resuscitative interventions have focused on preload and afterload support. Outcomes remain poor due to several factors but poor coronary perfusion undoubtedly plays a role. The aim of this study is to characterize the relationship between arterial pressure and flow during hemorrhage in an effort to better describe the terminal phases of exsanguination.Male swine weighing 60 kg to 80 kg underwent splenectomy and instrumentation followed by a logarithmic exsanguination until asystole. Changes in hemodynamic parameters over time were compared using one-way, repeated measures analysis of variance.Nine animals weighing 69 ±â€Š15 kg were studied. Asystole occurred at 53 ±â€Š13 min when 52 ±â€Š11% of total blood volume has been shed. The greatest fall in mean hemodynamic indices were noted in the first 15 min: SBP (80-42 mm Hg, P = 0.02), left ventricular end-diastolic volume (94-52 mL, P = 0.04), cardiac output (4.8-2.4 L/min, P = 0.03), coronary perfusion pressure (57-30 mm Hg, P = 0.01), and stroke volume (60-25 mL, P = 0.02). This corresponds to the greatest rate of exsanguination. Organized cardiac activity was observed until asystole without arrythmias. Coronary flow was relatively preserved throughout the study, with a precipitous decline once mean arterial pressure was less than 20 mm Hg, leading to asystole.In this model, initial hemodynamic instability was due to preload failure, with asystole occurring relatively late, secondary to failure of coronary perfusion. Future resuscitative therapies need to directly address coronary perfusion failure if effective attempts are to be made to salvage these patients.


Assuntos
Procedimentos Endovasculares , Exsanguinação/fisiopatologia , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Ressuscitação , Choque Hemorrágico/fisiopatologia , Animais , Pressão Sanguínea/fisiologia , Modelos Animais de Doenças , Exsanguinação/complicações , Parada Cardíaca/etiologia , Masculino , Choque Hemorrágico/etiologia , Choque Hemorrágico/terapia , Volume Sistólico/fisiologia , Suínos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa