Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Vasc Surg ; 78(6): 1402-1408.e1, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37454954

RESUMO

OBJECTIVE: This article reports on a retrospective observational study designed to evaluate the incidence, etiology, and clinical implications of aortic neck dilation following thoracic endovascular aortic repair (TEVAR) for aneurysms with landing zones II and III. METHODS: The study included 37 patients who underwent TEVAR and had postoperative computed tomography angiography available within 30 days and at least one computed tomography angiography at 1 year postoperatively. The primary end point was proximal aortic dilation (defined as growth ≥5 mm or ≥10% of the original diameter), and secondary end points included annual growth of the aneurysmal sac, device migration, endoleak, and reintervention with additional neck-related adverse events. The measurements taken during follow-up included the maximum diameter of the aneurysm and aortic diameter at various locations relative to the stent graft. RESULTS: During follow-up, a significant increase in aortic diameter was observed at the proximal edge of TEVAR. The estimated freedom from 5 mm or 10% proximal aortic neck growth at 1, 2, and 3 years was 81%, 70%, and 65%, respectively. At the proximal edge of TEVAR the type III aortic arch was significantly associated with 5 mm growth during follow-up (P = .047) and this growth (5 mm or 10%) as well as a 10% increase at +20 mm were significantly associated with more aortic-related reinterventions. Moreover, an aortic diameter at the start <36 mm was associated with a greater increase during follow-up (area under curve in receiver operating characteristic >80%; P < .05). CONCLUSIONS: The study concludes that proximal aortic dilation after TEVAR is a common and progressive phenomenon, and the management strategies for aortic neck dilation, including surveillance, secondary interventions, and open conversion, should be considered carefully to optimize patient outcomes and improve the long-term success of the procedure.


Assuntos
Doenças da Aorta , Correção Endovascular de Aneurisma , Humanos , Angiografia , Aorta , Dilatação , Estudos Retrospectivos
2.
J Vasc Surg ; 69(4): 1003-1010, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30528407

RESUMO

OBJECTIVE: The objective of this study was to evaluate the effect of image fusion (IF) technology in thoracic endovascular aortic repair (TEVAR) on reducing radiation exposure (dose and time), amount of injected iodinated contrast medium needed, and procedure time. METHODS: We performed a review of our institutional endovascular aortic database of patients who had undergone TEVAR between 2008 and 2016 before and after the installation of a three-dimensional (3D) IF computed tomography system in our hybrid operating room. All patients were operated on using the same radiologic equipment with or without IF. RESULTS: The 146 patients who had undergone elective or emergent TEVAR with preoperative computed tomography angiography done in 1-mm-thick slices were divided into two groups: the IF group (98 patients), in which TEVAR was performed using intraoperative IF with the two-dimensional-3D registration method; and 48 controls without the use of IF. The IF group received a significantly reduced dose of contrast material, with a median of 70 mL (interquartile range [IQR], 50-101 mL) compared with controls receiving 104 mL (IQR, 69-168 mL; P < .001).Patients who underwent hybrid TEVAR had a significantly reduced procedure time under IF guidance (n = 25) compared with controls (n = 11; median, 162 minutes [IQR, 139-199 minutes] vs 213 minutes [IQR, 189-298 minutes]; P = .015). In addition, the intraoperative fluoroscopy time was reduced to 9 minutes (IQR, 6-13 minutes) vs 23 minutes (IQR, 12-45 minutes; P < .005). However, the radiation dose (dose-area product) was similar for the two groups (P = .37).In patients who underwent plain TEVAR (n = 74) without a carotid-subclavian bypass, the IF group needed significantly less contrast material (median, 64 mL [IQR, 43-81 mL]) compared with the control group (median, 98 mL [IQR, 60-180 mL]; P = .003), whereas intraoperative radiation exposition, procedure time, and fluoroscopy time did not statistically significantly differ between the two groups. CONCLUSIONS: The IF technology using the two-dimensional-3D registration method was associated with reduced intraoperative contrast material volume in performing TEVAR. IF seemed to shorten the operation and radiation times in the more complicated (hybrid) TEVAR cases. However, a prospective study is needed to look at the dose-area product, fluoroscopy time, and procedure time in a larger cohort of patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/métodos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares/métodos , Imageamento Tridimensional/métodos , Duração da Cirurgia , Radiografia Intervencionista/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/efeitos adversos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada/efeitos adversos , Meios de Contraste/efeitos adversos , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Fluoroscopia , Humanos , Imageamento Tridimensional/efeitos adversos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Stents , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Fatores de Tempo , Resultado do Tratamento
3.
Eur J Vasc Endovasc Surg ; 58(6): 831-838, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31615695

RESUMO

OBJECTIVES: At 12 months follow up of the PLIANT study, clinical success and efficacy of the E-liac Stent Graft System (JOTEC GmbH, Hechingen, Germany) were evaluated. Clinical success was defined as aneurysm exclusion (no type I, III, IV endoleak) with primary patency of the internal iliac artery (IIA) and external iliac artery (EIA) on the E-liac implantation side. METHODS: In this prospective multicentre European observational study, clinical and morphological data of 45 patients (93% male, mean age 72 y) were prospectively collected in 11 European centres between July 2014 and June 2016. Forty patients underwent an aorto-iliac (three patients bilaterally) treatment and five an isolated iliac treatment. RESULTS: At 12 months follow up, data were available for 42 patients. Overall clinical success at 12 months was 90%, with a survival rate of 100%. Four patients (10%) did not achieve clinical success, one with an internal iliac artery (IIA) occlusion on the E-liac implantation side, one with an infrarenal type Ia endoleak, and two with type Ib endoleaks in IIA. At 12 months the primary patency rate in the internal iliac artery on the iliac side branch implantation side was 98%. Two patients (5%) received E-liac related re-interventions: one caused by an edge stenosis at the distal end of the graft limb in the external iliac artery (EIA) and one caused by thrombo-embolism in the external iliac artery. Thus, for the EIA, primary and secondary patency rates were 98% and 100%, respectively. CONCLUSIONS: The low device related re-intervention rate of 5%, the high survival rate of 100%, and the high primary patency rates of 98% for the IIA and EIA at 12 month follow up demonstrate the safety and efficacy of the E-liac Stent Graft System. Long term 36 month results are awaited to confirm the efficacy and durability.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Endoleak/epidemiologia , Procedimentos Endovasculares/instrumentação , Oclusão de Enxerto Vascular/epidemiologia , Aneurisma Ilíaco/cirurgia , Stents Metálicos Autoexpansíveis/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Europa (Continente) , Feminino , Seguimentos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reoperação/estatística & dados numéricos , Resultado do Tratamento
4.
Ann Vasc Surg ; 61: 116-123, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31394247

RESUMO

BACKGROUND: The aim of the present study was to define the possible anatomical and technical parameter that might predict the occurrence of gutter endoleak or type Ia endoleak (EL Ia) in patients treated with the chimney graft (CG) technique for the brachiocephalic trunk (BCT) and left common carotid artery (LCCA) due to aortic arch pathologies. METHODS: We reviewed our institutional endovascular aortic database of patients, who between 2010 and 2018 had undergone thoracic endovascular aortic repair (TEVAR) with chimney graft technique (ChTEVAR) as a debranching method of the supraaortic arteries. RESULTS: ChTEVAR was performed in 45 patients of whom a chimney in both the LCCA and the BCT was used in 32 patients, only in the LCCA in twelve patients, and only in the BCT in one patient. Eight patients (17.8%) had an EL Ia (based on postoperative computed tomography angiography). No late EL Ia was detected during the follow-up period. All patients with a postoperative EL Ia received 2 CGs with one each for the BCT, and LCCA had either no or a sealing ring distal to the most distal chimney of less than 10 mm versus patients with a longer sealing zone (P = 0.043). Patients with an endoleak did not differ from those without endoleak with respect to stent-graft oversizing, the diameter of the proximal and distal landing zones, or the aortic diameter directly proximal to the pathology. CONCLUSIONS: A sealing ring distal to the most distal chimney of more than 10 mm seems to be associated with a reduced risk of an EL Ia. The relatively few patients and the single-center nature require larger studies to verify the present results.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Bases de Dados Factuais , Endoleak/diagnóstico por imagem , Endoleak/fisiopatologia , Feminino , Alemanha , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Vasa ; 48(2): 158-166, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30376415

RESUMO

BACKGROUND: Peripheral arterial disease (PAD) is one of the major manifestations of general atherosclerosis and strongly associated with increased cardiovascular morbidity and mortality. Because only few epidemiologic studies are available concerning the prevalence of PAD in inhabitants ≥ 80 years of age, we screened inhabitants of nursing care homes in Germany for PAD and cardiovascular diseases and to assess the one year mortality. PATIENTS AND METHODS: We conducted a prospective cohort study, screening inhabitants of 42 nursing homes for PAD. Demographic data, comorbidities, cardiovascular risk factors and daily medication were collected. PAD was defined as ankle-brachial index < 0.9. During a follow up period of one year, cardio- and cerebrovascular events and mortality were recorded, as well as the rate of falls and major amputation. RESULTS: 1,329 probands (391 men, 938 women) > 60 years were eligible for further analysis. The mean age was 84.1 years (range 61-107 years) and the prevalence of PAD was 31.5 % . Media sclerosis was found in up to 17 %, and an existing diagnosis of PAD (in case of pathological ABI) and undertreatment was common. Probands with PAD were less likely to be treated according to guideline recommendations (antiplatelet therapy, beta blockers, statins) than probands with coronary artery disease (CAD). The overall one-year mortality was 19.8 % (n = 236), significantly higher than for a gender and age matched German population (p < 0.001). CONCLUSIONS: The current study shows a high prevalence of PAD in German nursing care homes. The one year mortality was not significantly different between probands with PAD and those with severe PAD (defined as an ABI of ≤ 0.5), whereas a media sclerosis was associated with an increased risk in probands with CAD in comparison to those without. Use of anti-diabetic agents and aspirin in monotherapy was associated with a reduced one-year mortality risk.


Assuntos
Aterosclerose , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Casas de Saúde , Prevalência , Estudos Prospectivos , Fatores de Risco
6.
J Endovasc Ther ; 25(2): 247-251, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29466897

RESUMO

PURPOSE: To investigate the long-term outcomes of endovascular aneurysm repair (EVAR) and open surgical repair (OSR) of infrarenal abdominal aortic aneurysm in octogenarian patients and to compare them with the overall expected survival based on a sex- and age-matched German population. METHODS: A total of 177 patients (median age 82 years; 149 men) ≥80 years old (range 80-92) who underwent primary elective repair of an infrarenal aortic aneurysm (≥5 cm) between 1998 and 2015 were identified in a database search. Two groups of patients were formed based on the type of procedure: 131 EVAR patients (median age 83 years; 114 men) and 46 OSR patients (median age 82 years; 35 men). RESULTS: The median follow-up was 5 years for the OSR group and 4.5 years for the EVAR group. Kaplan-Meier analysis showed no significant difference in survival between the EVAR and OSR groups at 78 months. The observed survival of all study patients was not statistically different from the expected survival of a sex- and age-matched German population, which was true separately for women and men. CONCLUSION: The patients in this study seemed to reach normal life expectancy in comparison to the age- and sex-matched general population with a similar cumulative survival in both study groups over 5 years of follow-up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso de 80 Anos ou mais , Feminino , Humanos , Expectativa de Vida , Masculino , Estudos Retrospectivos , Resultado do Tratamento
7.
Ann Vasc Surg ; 51: 177-186, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29522869

RESUMO

OBJECTIVE: This study aimed to evaluate the accuracy and the effectiveness of 2D-3D registration method of image fusion (IF) technology in endovascular aneurysm repair (EVAR). METHODS: We performed a review of our institutional endovascular aortic database of patients who had undergone EVAR between 2011 and 2015 before and after the installation of a 3D IF computed tomography system in our hybrid operating room. RESULTS: The accuracy was assessed in 14 endovascular procedures and showed a median registration error of 1.8 mm at the origin of the right renal artery and 1.0 mm at the origin of the left renal artery and a complete visual accuracy in 42% of the cases. EVAR was performed using the intraoperative IF technique with a 2D-3D registration method in 105 patients (group IF), whereas 47 patients done without served as controls. The IF group had a significantly reduced amount of used contrast compared with controls with a median of 58 mL and P < 0.0001. The intraoperative exposition to radiation was similar between the 2 groups with a median dose area product of 2,343.7 cGy cm2 in the IF group and 3,219 cGy cm2 among the controls (P = 0.457). The radiation dose in the sub group IF (including patients operated by the 2 most experienced surgeons) was lower than that in sub controls (median, 1,087 cG cm2 vs. 2,705.3 cG cm2, P = 0.012). The procedure time and the time of intraoperative radiation did not differ between the study groups (P = 0.117 and 0.106, respectively), as did not fluoroscopy time in the sub group IF (median, 6.3 min, vs. 9.5 min, P = 0.067), but for the 2 most experienced surgeons, the procedural time was shortened when using IF (P = 0.002). CONCLUSIONS: The 2D-3D registration method of IF guidance is accurate to delineate the vessels of interest and could help the execution of the EVAR procedures with a significantly reduced amount of contrast medium and also with reduced radiation and shorter procedural duration when surgeons are more familiar with EVAR and IF.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Imageamento Tridimensional/métodos , Duração da Cirurgia , Exposição à Radiação/prevenção & controle , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Intervencionista , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Aortografia/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Meios de Contraste/efeitos adversos , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
8.
Vascular ; 26(6): 647-656, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30037302

RESUMO

OBJECTIVES: To study the safety and feasibility of the E-liac Stent Graft System® in patients with aorto/iliac aneurysms. METHODS: A prospective multicentric European registry of patients receiving the E-liac Stent Graft System® was conducted. Endpoints of the study included the technical success as well as periprocedural events and 30-day endoleaks, reinterventions, internal and external iliac artery patency and mortality. RESULTS: Between July 2014 and June 2016, a total of 45 patients (93% men, mean age 72 years, range 53-90 years) were enrolled at 11 sites in four European countries. Five patients received an isolated iliac treatment. Thirty-seven patients were treated with a combination of an abdominal stent graft and a unilateral E-liac and three in combination with bilateral E-liac. All E-liac Stent Grafts (48) were implanted in the intended position and the internal iliac arteries were successfully bridged. Two patients did not receive clinical success, due to endoleak type Ia of the aortic stent graft. At 30-day follow-up, clinical success rate was 96%. Three successful endovascular reinterventions were performed within the 30-day follow-up: one due to a type Ia endoleak in the common iliac artery, one due to type Ia endoleak of the aortic stent graft, and one due to bilateral lower limb claudication provoked by stent graft limb stenosis. At 30-day, a 100% survival rate and complete absence of pelvic or buttock ischemia/claudication were reported. Primary patency at 30 days was 100% for the internal iliac artery and 98% for the external iliac artery with an assisted patency of 100% in the latter. CONCLUSIONS: The high clinical success rate, low rates of device-related reinterventions (2%), and excellent patency rate demonstrate the safety and feasibility of the E-liac Stent Graft System. Long-term results are awaited to state efficacy and durability. Clinical Trials.gov. Identifier no. NCT02209194.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
9.
J Vasc Surg ; 66(5): 1602-1610.e2, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28847663

RESUMO

OBJECTIVE: The aim of this study was to provide a review of the literature on the use of chimney graft (CG) technique in treating arterial diseases of the aortic arch and to extrapolate conclusions by summarizing the reported outcomes in a meta-analysis. METHODS: An extensive electronic search was made using PubMed/MEDLINE, Science Direct Databases, and the Cochrane Library. Included in this meta-analysis were all papers published up to February 2016 on endovascular chimney technique in the arch vessels with or without adjunct extra-anatomic debranching, in any language, providing data about at least one of the essential outcomes: early and late type I endoleak, 30-day mortality rate, development of perioperative stroke, patency, and retrograde aortic dissection. RESULTS: Of the 478 reports yielded by the electronic search, a total of 11 publications (on 373 patients and 387 CGs) fulfilled the inclusion criteria and were included in this study. The overall estimated proportion of technical success was 91.3% (95% confidence interval [CI], 87.4%-94.0%). Of the 373 patients, 26 (7%) experienced a type Ia endoleak in the perioperative period. The overall estimated proportion of early type Ia endoleak was 9.4% (95% CI, 6.5%-13.4%). Among the 10 studies that provided data, a retrograde type A dissection was observed in 2 of 351 patients, resulting in an overall estimated proportion of 1.8% (95% CI, 0.8%-4.0%). The pooled 30-day mortality rate was 7.9% (95% CI, 4.6%-13.2%). The pooled estimation for reintervention was 10.6% (95% CI, 5%-21%); for major stroke, 2.6% (95% CI, 1.3%-5.0%); for early patency, 97.9% (95% CI, 95.8%-99%); and for late patency, 92.9% (95% CI, 87.3%-96%). CONCLUSIONS: Treatment of aortic diseases involving the aortic arch poses a great challenge. The CG technique has been applied as an alternative treatment option. This meta-analysis shows that endovascular repair of aortic arch disease using a CG technique in the aortic arch vessels is technically feasible and effective but not without major risk of complications.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Doenças da Aorta/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
10.
J Vasc Surg ; 65(1): 46-51, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27575811

RESUMO

OBJECTIVE: The influence of endovascular aneurysm repair (EVAR) on renal function is of high concern. The question whether stent graft fixation type plays a significant role in renal outcome after EVAR is still debated. However, other factors, such as repeated contrast medium exposure, should also be considered. METHODS: We performed a two-center, stratified-cohort case control study to evaluate the influence of last-generation abdominal endografts with suprarenal (SR) vs infrarenal (IR) fixation on renal function. RESULTS: From a total of 276 patients, 134 were treated with IR fixation (group A) and 142 with SR fixation (group B) stent grafts. There was no significant difference in intraoperative contrast medium use (mean 120.0 mL group A vs 104.8 mL; P = .087) between the two cohorts. Overall, 11.2% of the patients (31/276) showed a relevant decline (≥20%) of estimated glomerular filtration rate (eGFR) postoperative and 11.5% (31/269) after 12 months. Furthermore, 19/134 (14.2%) patients in group A and 12/142 (8.5%) patients in group B showed a postoperative decrease of eGFR ≥20% (P = .132). Comparing the 12-month follow up, there was also no significant difference between the two groups (group A, n = 18/134; group B, n = 13/135; P = .329). Patients with only one contrast-enhanced computed tomography scan postoperatively (4/102; 3.9%) showed significant less renal deterioration after 12 months compared with the rest of the study collectively (27/166; 16.9%; P = .002). Comparing IR vs SR fixation in these patients, there was no significant difference between the two groups. One patient (1/35; 2.9%) with IR fixation (group A) and 3/67 (4.5%) with SR fixation (group B) showed a decline in eGFR values of ≥20% after 12 months (P = 1.0). CONCLUSIONS: Our study showed no significant difference in renal impairment between SR and IR fixation in EVAR for IR abdominal aortic aneurysm. However, significantly more renal deterioration was observed in patients with increased postoperative contrast medium expose. Therefore, alternatives such as contrast- enhanced duplex ultrasound or magnetic resonance imaging for EVAR surveillance should be considered.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aortografia/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada/efeitos adversos , Meios de Contraste/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Taxa de Filtração Glomerular/efeitos dos fármacos , Rim/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares/instrumentação , Feminino , Alemanha , Humanos , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
11.
Ann Vasc Surg ; 44: 113-118, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28546041

RESUMO

BACKGROUND: The purpose of the present study was to compare the long-term survival in matched cohorts of patients with infrarenal abdominal aortic aneurysm (AAA) undergoing an elective open repair (OR) or an endovascular aneurysm repair (EVAR). METHODS: Patients with a primary elective repair of an infrarenal aortic aneurysm between 1998 and 2006 were identified in a retrospective review of our single-center database. EVAR and OR patients were matched with respect to age, gender, renal disease, tobacco use, hypertension, chronic obstructive pulmonary disease, and coronary artery disease. The primary end points were the early mortality and all-cause mortality during follow-up. RESULTS: A total of 465 patients with elective infrarenal aortic aneurysm repair were identified in the database. The EVAR and OR patients were matched according to the above-mentioned characteristics, and finally, 108 patients were included in each group. The early mortality encountered was only one death in the open group (P = 0.316). The Kaplan-Meier survival analysis by the log-rank test showed no difference in cumulative survival between OR group and EVAR group (P = 0.458). Seventeen reinterventions (16.7%) in the EVAR group vs. 7 (6.5%) in the OR group (P = 0.018) were necessary during follow-up. CONCLUSIONS: OR and EVAR can be performed safely for elective treatment of AAA. The reintervention rate is, as expected, significantly higher in the EVAR group, but the long-term survival remains equal in both groups.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/terapia , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
12.
Ann Vasc Surg ; 42: 183-188, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28288886

RESUMO

BACKGROUND: This study aims to examine the relationship between weather changes (atmospheric pressure and temperature) and incidence of rupture of abdominal aortic aneurysm (AAA). METHODS: All patients with ruptured infrarenal AAA and who were referred to our institution between August 1998 and August 2015 were prospectively entered into a database of which a retrospective review of a ruptured AAA was performed. The needed information about the daily atmospheric pressure and air temperature could be extracted from the meteorological unit in Cologne. RESULTS: During the study period (6,225 days), a total number of 154 patients with confirmed ruptured AAA were identified. Basic patients' characteristics are tabulated. The mean daily atmospheric pressure during the study was 1,004.04 ± 8.79 mBar ranging from 965.40-1031.80 mBar. The mean atmospheric pressure on the days of rupture was 1,004.03 vs. 1,004.68 on those days when no rupture occurred (P = 0.34). The mean atmospheric pressure on the day of rupture and that on the preceding day was not significantly different (1,004.78 vs. 1,005.44 with P = 0.13). The air temperature (10.62 ± 6.25 vs. 10.77 ± 6.83°C, P = 0.787) was equally distributed between days of rupture events and control days. CONCLUSIONS: The present study could not show a significant association between the monthly and seasonal difference in atmospheric pressure and the prevalence of AAA rupture as it has been supposed by previous studies.


Assuntos
Aneurisma da Aorta Abdominal/epidemiologia , Ruptura Aórtica/epidemiologia , Pressão Atmosférica , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Bases de Dados Factuais , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Estações do Ano , Temperatura , Fatores de Tempo
13.
World J Surg ; 40(7): 1771-7, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26913734

RESUMO

BACKGROUND: Preoperative risk stratification of the immediate postoperative death after surgery may be helpful for the decision-making for patients with ruptured AAAs (rAAs). The purpose of this study was to apply and validate the Glasgow aneurysm score (GAS) and the Hardman Index (HI) in predicting 30-day/in-hospital mortality in open surgical repair (OSR) and endovascular repair (rEVAR) of rAAAs. METHODS: We conducted a retrospective review of a prospectively created database including all patients with a rAAA referred to our Institution between August 1998 and December 2014. Primary outcome was 30-day/in-hospital mortality. Multivariate logistic regression analysis was used to identify independent risk factors. The receiver-operator characteristic curve was used to determine the value of the HI and GAS in predicting 30-day/in-hospital death. RESULTS: A total of 150 patients (130 patients received OSR, 20 patients rEVAR) were included in our analysis. The 30-day/in-hospital mortality was 34.0 % for the entire cohort: 36.15 % for OSR group and 20.0 % for rEVAR group (p 0.210). A multivariate analysis in the OSR group evidenced that unconsciousness was a statistically significant [adjusted odds ratio (OR) 8.00] predictor of 30-day/in-hospital mortality. The mean GAS was 86.9 ± 16.1 for the OSR group and 88.1 ± 11.2 for the rEVAR group (p 0.773). The AUC for GAS was 0.805 among OSR patients and 0.975 among rEVAR patients. The mean HI in the OSR group was 1.11 ± 1.0 and the AUC for HI was 0.82. CONCLUSIONS: Surgical repair of rAAAs is still associated with a considerable mortality rate. We confirmed the great discriminative ability of GAS in patients with rAAAs treated with OSR. With regard to HI, this scoring system could accurately predict early mortality after OSR in our cohort but failed to identify patients at highest risk for postoperative mortality.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Mortalidade Hospitalar , Procedimentos Cirúrgicos Vasculares , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Procedimentos Endovasculares , Feminino , Cardiopatias/epidemiologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Inconsciência/epidemiologia
14.
Vascular ; 24(5): 469-80, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26462537

RESUMO

A persistent sciatic artery is a very rare vascular anomaly with an estimated incidence of 0.025-0.06% and with less than 200 described cases in the literature. During early embryonic development, the sciatic artery delivers the major blood supply to the lower limb and usually disappears when the superficial femoral artery has developed properly. The usual form of presentation in adults is the aneurysmal degeneration of the sciatic artery or less frequently with another complication (thrombosis, embolism, neuralgia). We describe three cases of a complete sciatic artery (two cases are bilateral and one is unilateral) associated with lower limb ischemia caused by embolism from the aneurysmal degeneration of the sciatic artery at the buttock level in two cases and atherosclerotic degeneration of the lower limb arteries in the third case. We also describe two combined therapy methods consisted of limb revascularization with vein-graft bypass and endovascular embolization of the aneurysm with vascular plug in the first case, in the second case combination of localized thrombolysis therapy followed by a bypass and an ilio-pedal vein bypass in the third one. And we discuss later the reported clinical outcome after surgical and endovascular treatment of this anomaly in the literature.


Assuntos
Aneurisma/terapia , Artérias/cirurgia , Aterosclerose/terapia , Embolia/terapia , Embolização Terapêutica , Procedimentos Endovasculares , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Terapia Trombolítica , Malformações Vasculares/complicações , Veias/transplante , Idoso , Aneurisma/complicações , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Angiografia Digital , Índice Tornozelo-Braço , Artérias/anormalidades , Artérias/diagnóstico por imagem , Aterosclerose/complicações , Aterosclerose/diagnóstico por imagem , Aterosclerose/cirurgia , Angiografia por Tomografia Computadorizada , Embolia/diagnóstico por imagem , Embolia/etiologia , Embolia/cirurgia , Feminino , Humanos , Isquemia/diagnóstico por imagem , Isquemia/etiologia , Isquemia/cirurgia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Malformações Vasculares/diagnóstico por imagem
15.
J Vasc Surg ; 62(4): 946-50, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25725598

RESUMO

BACKGROUND: We investigated the role of mannose-binding lectin (MBL) variant genotypes in patients with significant carotid restenosis after carotid endarterectomy (CEA) and who underwent a revision CEA. METHODS: This was a cross-sectional analysis of 97 patients enrolled between 2001 and 2013. Three groups were investigated: group A included patients with internal carotid artery restenosis, group B included patients without restenosis after CEA, and group C included patients with peripheral arterial disease but without any signs of a carotid stenosis. Venous blood samples were drawn for the genotyping for MBL2 by polymerase chain reaction and for the determination of the MBL serum concentration by enzyme-linked immunoabsorbent assay. RESULTS: The serum concentration of MBL was higher in patients with the normal genotype than in those with the genotype variants of MBL (95% confidence interval, 272.8-1008.7 µg/L; P = .001). There was no statistically significant difference among groups A, B, or C with respect to the presence of a variant genotype. Similarly, there was no significant gender difference regarding the presence of a variant genotype (P = .325). CONCLUSIONS: The presence of a variant genotype of the MBL2 gene (and the correspondingly lower serum concentration of this molecule) was not correlated with the development of carotid restenosis after CEA beyond a follow-up of 12 months.


Assuntos
Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Variação Genética , Lectina de Ligação a Manose/genética , Idoso , Estenose das Carótidas/genética , Ensaio de Imunoadsorção Enzimática , Feminino , Predisposição Genética para Doença/genética , Genótipo , Humanos , Masculino , Lectina de Ligação a Manose/sangue , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Recidiva
16.
J Clin Med ; 12(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37445445

RESUMO

Peripheral arterial disease (PAD) is associated with high cardiovascular morbidity and mortality. We aimed to examine this relation in a population that tends to be under-represented in research on the topic. In a prospective observational cohort study, residents of 45 nursing homes in Germany were screened for pathological ankle-brachial index (ABI) and observed for five years. Of 1333 participants (median age 84 years), 55.5% had a pathological ABI (≤0.9 or >1.4) on one or both legs. 84.7% of the probands with a low ABI (indicating PAD) had no previously known PAD diagnosis. The five-year mortality was 73.0%. Mortality was higher in individuals with a pathological ABI (76.5%) than in those with a normal ABI (68.7%, p = 0.003). An ABI > 1.4 was associated with a higher mortality (79.4%) than a reduced (74.7%) or normal ABI (68.7%, p = 0.011). Pathological ABI values were associated with an increase in mortality after correction for age, sex and all recorded comorbidities, including cardiac disease. Although PAD is highly prevalent in nursing home residents, it is underdiagnosed and undertreated. In the study cohort, both high and low ABI were important predictors of mortality. PAD deserves more attention in this high-risk population.

17.
Ther Adv Cardiovasc Dis ; 12(12): 321-326, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30244647

RESUMO

BACKGROUND:: There is still much controversy about whether meteorological conditions influence the occurrence of acute aortic dissection (AAD). The aim of the present study was to investigate the possible correlation between atmospheric pressure, temperature, lunar cycle and the event of aortic dissection in our patient population. METHODS:: The clinical data for 348 patients with AAD (73% type Stanford A) were confronted with the meteorological data provided by the Cologne weather station over the same period. RESULTS:: There were no statistically significant differences between meteorological parameters on days of AAD events compared with control days. A logistic regression model showed that air pressure (odds ratio [OR] 1.004, 95% confidence interval [CI] 0.991-1.017, p = 0.542), air temperature (OR 0.978, 95% CI 0.949-1.008, p = 0.145), season ( p = 0.918) and month of the event ( p = 0.175) as well as presence of full moon (OR 1.579, 95% CI 0.763-3.270, p = 0.219) were not able to predict AAD events. Also, no predictive power of meteorological data and season was found on analysing their impact on different types of AAD events. CONCLUSIONS:: Our study did not reveal any dependence of atmospheric pressure, air temperature or the presence of full moon on the incidence of different types of AAD.


Assuntos
Aneurisma Aórtico/epidemiologia , Dissecção Aórtica/epidemiologia , Estações do Ano , Tempo (Meteorologia) , Doença Aguda , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Pressão Atmosférica , Alemanha/epidemiologia , Humanos , Incidência , Lua , Estudos Retrospectivos , Fatores de Risco , Temperatura , Fatores de Tempo
18.
J Cardiovasc Surg (Torino) ; 59(1): 111-114, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28683542

RESUMO

BACKGROUND: We investigated the application and feasibility of a novel software tool designed for the visualization of the aortic root during transcatheter aortic valve implantation (TAVI). The final positioning of the device prior deployment remains the most critical phase during TAVI. METHODS: Philips "Vascular Outlining" prototype application was used during balloon expandable Edwards Lifesciences SapienXT valve deployment. It processes any angiographic sequences, extracting the static outline of vessels and projecting the two-dimensional vessel margins as a roadmap on live fluoroscopy. Preoperational planning, sizing and anatomical assessment of access routes were performed using computed tomography scans and the Philips "HeartNavigator" software. RESULTS: Fifteen high-risk aortic stenosis patients (mean age 82.0±6.6 years) underwent TAVI via transfemoral (N.=8), transapical (N.=4), and transaortic (N.=3) access routes. Mean logistic EuroSCOREs and STS-scores were 19.7±4.3% and 7.9±3.1%, respectively, mean aortic gradient was 66.3±18.3 mmHg. All valves were implanted successfully with none or trivial paravalvular regurgitation in 11 patients, mild in 3 patients, and moderate in 1 patient. TAVI was performed in all cases with only one aortic root contrast media injection during valve deployment. No major stroke or cardiovascular death occurred within 30 days. CONCLUSIONS: "Vascular Outlining"-guided implantation of the SapienXT valve is feasible. This new feature might increase the accuracy of valve placement and also may reduce the need for extra contrast media use during valve deployment. However, the lack of real-time motion compensation limits its wide application, as the overlay does not move together with respiratory and cardiac motion.


Assuntos
Software , Cirurgia Assistida por Computador/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Meios de Contraste , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Ther Adv Cardiovasc Dis ; 12(11): 289-298, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30227769

RESUMO

BACKGROUND: The aim of the present study was to determine whether raised preoperative serum creatinine affected the long-term outcome in patients undergoing surgical aortic repair for Stanford A acute aortic dissection (AAD). METHODS: A total of 240 patients diagnosed with Stanford A AAD underwent surgical repair from January 2006 to April 2015. A propensity score matching was applied, resulting in 73 pairs consisting of one group with normal and one group with preoperative elevated creatinine levels. The cohorts were well balanced for baseline and preoperative clinical characteristics. Both groups were compared regarding their early postoperative variables, as well as estimated survival with up to 9-year follow up. Also, the impact of acute postoperative kidney injury and its severity on long-term survival was analyzed. RESULTS: The proportion of patients suffering Stanford A AAD with raised creatinine levels was 31.3% ( n = 75). After propensity matching, there were no statistically significant differences regarding demographics, comorbidities, preoperative baseline and clinical characteristics. Postoperatively matched patients with elevated creatinine had longer intensive care unit ( p < 0.001) and total hospital stay ( p = 0.002), prolonged intubation times ( p = 0.014), higher need for hemofiltration ( p < 0.001), higher incidence of temporary neurological disorders ( p = 0.16), infection ( p = 0.005), and trend toward higher incidence of sepsis ( p = 0.097). However, there were no significant differences regarding 30-day mortality (20.5% versus 20.5%, p = 1.000) and long-term overall survival. Further, neither the incidence nor the different stages of acute kidney injury according to the Acute Kidney Injury Network showed any statistically significant differences in terms of long-term survival for both groups [log rank p = 0.636, Breslow (generalized Wilcoxon) p = 0.470, Tarone-Ware p = 0.558]. CONCLUSIONS: Patients with elevated creatinine levels undergoing surgical repair for Stanford A AAD demonstrate higher rate of early postoperative complications. However, 30-day mortality and long-term survival in this patient cohort is not significantly impaired.


Assuntos
Injúria Renal Aguda/etiologia , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Creatinina/sangue , Nefropatias/sangue , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Doença Aguda , Injúria Renal Aguda/sangue , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/mortalidade , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Biomarcadores/sangue , Feminino , Humanos , Estimativa de Kaplan-Meier , Nefropatias/complicações , Nefropatias/diagnóstico , Nefropatias/mortalidade , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima , Procedimentos Cirúrgicos Vasculares/mortalidade
20.
J Cardiothorac Surg ; 11: 24, 2016 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-26832960

RESUMO

BACKGROUND: In patients undergoing transfemoral transcatheter aortic valve implantation, previous endovascular interventions bear a risk for the valve frame to get stucked to the aortic stents. CASE PRESENTATION: We report on a 75-year-old frail patient with severe aortic stenosis and a rapid increase of an infra-renal aneurysm. He had a history of multiple endovascular interventions on the aorta. Due to his frail preoperative status we decided to perform a transfemoral transcatheter aortic valve implantation in combination with a simultaneous surgical abdominal aneurysm repair. To allow an atraumatic passage of the Edwards SAPIEN 3 valve across the endovascular stents we used a special technique. CONCLUSIONS: The transfemoral approach in patients with previous endovascular stenting can be performed successfully by a partial inflation of the distal balloon.


Assuntos
Estenose da Valva Aórtica/cirurgia , Stents , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Endovasculares , Próteses Valvulares Cardíacas , Humanos , Masculino , Artéria Renal/diagnóstico por imagem , Artéria Renal/cirurgia , Reoperação/métodos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa