Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 56(14): 3989-3994, 2017 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-29047526

RESUMO

In visual experiments that require real-time partial correction of wavefront aberrations, small errors occur that accumulate over time and lead to drifts in Zernike coefficients of the uncorrected aberrations. A simple algorithm that does not require the inclusion of an additional optical path to obtain independent measurements of the eye's aberrations is described here, and its effectiveness in preventing these drifts is demonstrated.

2.
Vision Res ; 210: 108259, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37285782

RESUMO

High-density threshold perimetry has found that conventional static threshold perimetry misses defects due to undersampling. However, high-density testing can be both slow and limited by normal fixational eye movements. We explored alternatives by studying displays of high-density perimetry results for angioscotomas in healthy eyes-areas of reduced sensitivity in the shadows of blood vessels. The right eyes of four healthy adults were tested with a Digital Light Ophthalmoscope that gathered retinal images while presenting visual stimuli. The images were used to infer stimulus location on each trial. Contrast thresholds for a Goldmann size III stimulus were measured at 247 locations of a 13°×19° rectangular grid, with separation 0.5°, extending from 11° to 17° horizontally and -3° to +6° vertically, covering a portion of the optic nerve head and several major blood vessels. Maps of perimetric sensitivity identified diffuse regions of reduced sensitivity near the blood vessels, but these showed moderate structure-function agreement that was only modestly improved when effects of eye position were accounted for. An innovative method termed slice display was used to locate regions of reduced sensitivity. Slice display demonstrated that many fewer trials could yield similar structure-function agreement. These results are an indication that test duration might be reduced dramatically by focusing on location of defects rather than maps of sensitivity. Such alternatives to conventional threshold perimetry have the potential to map the shape of defects without the extensive time demands of high-density threshold perimetry. Simulations illustrate how such an algorithm could operate.


Assuntos
Disco Óptico , Testes de Campo Visual , Adulto , Humanos , Testes de Campo Visual/métodos , Campos Visuais , Transtornos da Visão , Algoritmos
3.
Biomed Opt Express ; 8(10): 4717-4728, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082097

RESUMO

Eyes of children and young adults change their optical power to focus nearby objects at the retina. But does accommodation function by trial and error to minimize blur and maximize contrast as is generally accepted? Three experiments in monocular and monochromatic vision were performed under two conditions while aberrations were being corrected. In the first condition, feedback was available to the eye from both optical vergence and optical blur. In the second, feedback was only available from target blur. Accommodation was less precise for the second condition, suggesting that it is more than a trial-and-error function. Optical vergence itself seems to be an important cue for accommodation.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa