Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Curr Cardiol Rep ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748329

RESUMO

PURPOSE OF REVIEW: This review offers an evidence-based analysis of established and emerging cardiovascular magnetic resonance (CMR) techniques used to assess the severity of primary mitral regurgitation (MR), identify adverse cardiac remodeling and its prognostic effect. The aim is to provide different insights regarding clinical decision-making and enhance the clinical outcomes of patients with MR. RECENT FINDINGS: Cardiac remodeling and myocardial replacement fibrosis are observed frequently in the presence of substantial LV volume overload, particularly in cases with severe primary MR. CMR serves as a useful diagnostic imaging modality in assessing mitral regurgitation severity, early detection of cardiac remodeling, myocardial dysfunction, and myocardial fibrosis, enabling timely intervention before irreversible damage ensues. Incorporating myocardial remodeling in terms of left ventricular (LV) dilatation and myocardial fibrosis with quantitative MR severity assessment by CMR may assist in defining optimal timing of intervention.

2.
Curr Cardiol Rep ; 26(5): 413-421, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38517604

RESUMO

PURPOSE OF REVIEW: Cardiac magnetic resonance (CMR) is emerging as a valuable imaging modality for the assessment of aortic regurgitation (AR). In this review, we discuss the assessment of AR severity, left ventricular (LV) remodeling, and tissue characterization by CMR while highlighting the latest studies and addressing future research needs. RECENT FINDINGS: Recent studies have further established CMR-based thresholds of AR severity and LV remodeling that are associated with adverse clinical outcomes, and lower than current guideline criteria. In addition, tissue profiling with late gadolinium enhancement (LGE) and extracellular volume (ECV) quantification can reliably assess adverse myocardial tissue remodeling which is also associated with adverse outcomes. The strengths and reproducibility of CMR in evaluating ventricular volumes, tissue characteristics, and regurgitation severity position it as an excellent modality in evaluating and following AR patients. Advanced CMR techniques for the detection of tissue remodeling have shown significant potential and merit further investigation.


Assuntos
Insuficiência da Valva Aórtica , Fibrose , Índice de Gravidade de Doença , Remodelação Ventricular , Humanos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Fibrose/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Meios de Contraste
3.
J Cardiovasc Magn Reson ; 22(1): 55, 2020 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-32727590

RESUMO

BACKGROUND: A comprehensive non-invasive evaluation of bioprosthetic mitral valve (BMV) function can be challenging. We describe a novel method to assess BMV effective orifice area (EOA) based on phase contrast (PC) cardiovascular magnetic resonance (CMR) data. We compare the performance of this new method to Doppler and in vitro reference standards. METHODS: Four sizes of normal BMVs (27, 29, 31, 33 mm) and 4 stenotic BMVs (27 mm and 29 mm, with mild or severe leaflet obstruction) were evaluated using a CMR- compatible flow loop. BMVs were evaluated with PC-CMR and Doppler methods under flow conditions of; 70 mL, 90 mL and 110 mL/beat (n = 24). PC-EOA was calculated as PC-CMR flow volume divided by the PC- time velocity integral (TVI). RESULTS: PC-CMR measurements of the diastolic peak velocity and TVI correlated strongly with Doppler values (r = 0.99, P < 0.001 and r = 0.99, P < 0.001, respectively). Across all conditions tested, the Doppler and PC-CMR measurement of EOA (1.4 ± 0.5 vs 1.5 ± 0.7 cm2, respectively) correlated highly (r = 0.99, P < 0.001), with a minimum bias of 0.13 cm2, and narrow limits of agreement (- 0.2 to 0.5 cm2). CONCLUSION: We describe a novel method to assess BMV function based on PC measures of transvalvular flow volume and velocity integration. PC-CMR methods can be used to accurately measure EOA for both normal and stenotic BMV's and may provide an important new parameter of BMV function when Doppler methods are unobtainable or unreliable.


Assuntos
Bioprótese , Ecocardiografia Doppler em Cores , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Imageamento por Ressonância Magnética , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/cirurgia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes
4.
J Card Surg ; 31(3): 139-46, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26821873

RESUMO

BACKGROUND: Transesophageal echocardiography (TEE) is recommended for diagnosis in patients suspected of prosthetic valve dysfunction, but could be limited in its ability to identify the etiology of these dysfunctions and to assess extracardiac structures. Our objective is to examine the usefulness of multidetector computed tomography (MDCT) in establishing the etiology of the dysfunctions and its clinical utility in preoperative assessment in these patients. METHODS: Twenty-two prosthetic heart valves from 20 consecutive patients who had a preoperative MDCT and underwent redo prosthetic valve procedures from December 2008 to February 2013 were examined retrospectively. Results from MDCT and TEE were compared to intraoperative findings. Extravalvular MDCT findings including coronary artery/bypass graft, high-risk features for reoperative cardiac surgery, and extracardiac findings were also assessed. RESULTS: MDCT correctly identified 15 valve regurgitation and seven valve obstructions compared to intraoperative findings. Both TEE and MDCT were able to correctly identify the etiologies in 93% (14/15) of regurgitant valves. However, MDCT was better able to identify the etiology of obstructive valves than TEE (86% [6/7] vs. 43% [3/7]) compared to intraoperative findings. In patients who had preoperative invasive angiography, MDCT correctly identified two patients with significant coronary artery disease (CAD) and ruled out 11 without significant CAD. Furthermore, MDCT detected five high-risk features for postoperative complications and eight clinically relevant extracardiac findings. CONCLUSIONS: MDCT displayed comparable or better diagnostic performance than TEE for identifying the type of dysfunction and its etiology, as well as providing additional coronary and other extravalvular evaluations useful for preoperative planning.


Assuntos
Doenças das Valvas Cardíacas/diagnóstico , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores , Reoperação , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Ecocardiografia Transesofagiana , Feminino , Doenças das Valvas Cardíacas/etiologia , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Curr Cardiol Rep ; 17(2): 3, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25618306

RESUMO

Echocardiographic evaluation of diastolic properties and assessment of hemodynamic status of the right and the left ventricle have been traditionally applied for many years in clinical practice. Establishment of diagnosis of diastolic dysfunction, grading, and estimation of filling pressures noninvasively adds prognostic information to the clinician, which may affect treatment management. Novel methods, including left atrium strain, left ventricular diastolic strain rate, and left ventricular untwisting rate, have been imported in clinical practice attempting to provide a more comprehensive and more accurate understanding of the mechanisms and diagnosis of diastolic dysfunction.


Assuntos
Diástole , Ecocardiografia Doppler , Insuficiência Cardíaca/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Guias de Prática Clínica como Assunto , Prognóstico , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
6.
Curr Cardiol Rep ; 15(8): 384, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23812836

RESUMO

The accurate quantification of mitral regurgitation (MR) using 2D imaging tools is difficult due to its structural complexity; however, it is crucially important in clinical medicine as MR severity has prognostic consequences. Novel 3-dimensional (3D) echocardiography and 3-dimensional (3D) color Doppler methods can provide quantitative and qualitative classification of MR including measurement of the vena contracta area, regurgitant volume, regurgitant fraction, and effective regurgitant orifice area (EROA). Nevertheless, with so many conventional and developing techniques it can be difficult to decide which technique to use for selected patients. We suggest using an approach that is focused not only on the techniques and measurements but also combines imaging portability, availability, clinical efficiency, and accurate and reproducible assessments. In this review we discuss the established and emerging applications of 3D color Doppler for the quantification of MR severity.


Assuntos
Insuficiência da Valva Mitral/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia
7.
Ann Noninvasive Electrocardiol ; 16(1): 49-55, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21251134

RESUMO

BACKGROUND: Although the association of repolarization alterations to the development of life-threatening ventricular arrhythmias has received considerable research attention, there is paucity of data regarding what may be considered as normal, especially in children. METHODS: To define electrocardiographic (ECG) and vectorcardiographic (VCG) descriptors of ventricular repolarization in healthy school-age children, 12-lead digital ECGs were obtained from 646 children (348 males/298 females, mean age 8.54 ± 1.86 years). All QT intervals were measured manually using the digitally stored ECGs. Orthogonal X, Y, and Z leads were reconstructed from the standard 12-lead ECGs and the maximal amplitudes of the spatial QRS and T vectors were calculated, as well as the spatial QRS-T angle. RESULTS: The mean heart rate was 95.3 ± 15.8 bpm and the QRS duration was 83.4 ± 9.3 ms. Mean QT interval was 334.1 ± 24.2 ms and the corrected QT interval was 436.5 ± 23.8 ms (Bazzet) and 404.3 ± 19.4 ms (Fridericia). Although the uncorrected maximum and mean QT intervals were significantly higher in boys (P values 0.011 and 0.009, respectively), there was no difference in the rate-corrected QT interval. The spatial QRS and T-vector amplitudes were 1512.0 ± 365.7 µV and 478.8 ± 149.3 µV, respectively. The spatial QRS-T angle was 14.1 ± 8.0 degrees. Although the mean QT interval showed significant increase with age (P = 0.014), all VCG parameters did not show significant variance with age. CONCLUSIONS: A range of ECG and VCG descriptors of ventricular repolarization was determined in a large sample of healthy school-age children to provide a data basis of normal values for future reference.


Assuntos
Sistema de Condução Cardíaco/fisiologia , Função Ventricular/fisiologia , Criança , Eletrocardiografia , Feminino , Humanos , Masculino , Valores de Referência , Vetorcardiografia
8.
J Cardiovasc Transl Res ; 14(4): 735-743, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32253745

RESUMO

Vortex formation time (VFT) is a dimensionless index used to quantify duration of vortex ring formation during diastole. We sought to investigate the effect of pharmaceutical stress on VFT in patients evaluated for ischemia. For this purpose, a standard dobutamine stress echo (DSE) protocol was performed in 50 consecutive patients, and VFT was calculated at rest and at peak. VFT was calculated from echocardiography measurements using a previously developed mathematical equation. VFTi was calculated as the percentage of change of VFTpeak, compared with VFTrest. Mean VFTrest was 2.46 (0.73) and mean VFTpeak 1.67 (0.57) with mean VFTi - 30.0% (19.8). In 14 (28%) patients, an ischemic response (DSE+) was documented. VFTi was significantly lower in DSE+ patients a finding which remained significant in the multivariate analysis after adjusting for age, sex, hypertension, diabetes, history of coronary artery disease, and relative increase of heart rate during stress. Graphical Abstract.


Assuntos
Agonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Circulação Coronária , Dobutamina/administração & dosagem , Ecocardiografia sob Estresse , Hemodinâmica , Isquemia Miocárdica/diagnóstico por imagem , Idoso , Velocidade do Fluxo Sanguíneo , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco
9.
Ann Noninvasive Electrocardiol ; 15(1): 17-25, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20146778

RESUMO

BACKGROUND: P waves > or = 110 ms in adults and > or = 90 ms in children are considered abnormal, signifying interatrial block, particularly in the first case. METHODS: To evaluate the prevalence of interatrial block in healthy school-aged children, we obtained 12-lead digital ECGs (Cardioperfect 1.1, CardioControl NV, Delft, The Netherlands) of 664 healthy children (349 males/315 females, age range 6-14 years old). P-wave analysis indices [mean, maximum and minimum (in the 12 leads) P-wave duration, P-wave dispersion, P-wave morphology in the derived orthogonal (X, Y, Z) leads, as well the amplitude of the maximum spatial P-wave vector] were calculated in all study participants. RESULTS: P-wave descriptor values were: mean P-wave duration 84.9 + or - 9.5 ms, maximum P-wave duration 99.0 + or - 9.8 ms, P dispersion 32.2 + or - 12.5 ms, spatial P amplitude 182.7 + or - 69.0 microV. P-wave morphology distribution in the orthogonal leads were: Type I 478 (72.0%), Type II 178 (26.8%), Type III 1 (0.2%), indeterminate 7 (1%). Maximum P-wave duration was positively correlated to age (P < 0.001) and did not differ between sexes (P = 0.339). Using the 90-ms value as cutoff for P-wave duration, 502 (75.6%) children would be classified as having maximum P-wave duration above reference range. The 95th and the 99th percentiles were in the overall population 117 ms and 125 ms, respectively. P-wave morphology type was not in any way correlated to P-wave duration (P = 0.715). CONCLUSIONS: Abnormal P-wave morphology signifying the presence of interatrial block is very rare in a healthy pediatric population, while widened P waves are quite common, although currently classified as abnormal.


Assuntos
Bloqueio Atrioventricular/epidemiologia , Eletrocardiografia/métodos , Eletrocardiografia/estatística & dados numéricos , Adolescente , Criança , Feminino , Grécia/epidemiologia , Humanos , Masculino , Prevalência , Valores de Referência , Processamento de Sinais Assistido por Computador , Vetorcardiografia/métodos , Vetorcardiografia/estatística & dados numéricos
11.
Int J Cardiovasc Imaging ; 34(1): 121-129, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28748418

RESUMO

We sought to determine the relation between myocardial extracellular volume (ECV), left ventricular (LV) diastolic function, and exercise tolerance in patients with hypertrophic cardiomyopathy (HCM). Forty five HCM patients with an ejection fraction >50% and no previous septal reduction therapy underwent imaging by CMR and transthoracic echocardiography. CMR was used to quantify LV volumes, mass, EF, LA volumes, scar burden, pre and post contrast T1 relaxation times and ECV. Echocardiography was used to measure outflow tract gradients, mitral inflow and annular velocities, circumferential strain, systolic, early and late diastolic strain rates. Exercise duration and peak oxygen consumption were noted. HCM patients had increased native T1 relaxation time and ECV vs. controls [ECV controls: 24.7 (23.2-26.4) vs. HCM: 26.8 (24.6-31.3)%, P = 0.014]. Both parameters were significantly associated with LV diastolic dysfunction, circumferential strain, diastolic strain rate and peak oxygen consumption (r = -0.73, P < 0.001). Compared to controls, HCM patients have significantly longer native T1 relaxation time and higher ECV. These structural changes lead to worse LV global and segmental diastolic function and in turn reduced exercise tolerance.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Tolerância ao Exercício , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Miocárdio/patologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/patologia , Cardiomiopatia Hipertrófica/fisiopatologia , Ecocardiografia Doppler , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
12.
Hellenic J Cardiol ; 57(3): 145-151, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27650593

RESUMO

This review focuses on the diagnostic value of novel echocardiographic techniques and the clinical application of recently described algorithms to assess tricuspid prosthetic valve function.


Assuntos
Ecocardiografia Tridimensional/métodos , Doenças das Valvas Cardíacas/cirurgia , Valva Tricúspide/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas , Humanos , Falha de Prótese
13.
JACC Cardiovasc Imaging ; 9(7): 785-793, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27184505

RESUMO

OBJECTIVES: The aim of this study was to evaluate cardiac magnetic resonance (CMR) phase-contrast (PC) measures of a bioprosthetic aortic valve velocity time integral (PC-VTI) to derive the effective orifice area (PC-EOA) and to compare these findings with the clinical standard of Doppler echocardiography. BACKGROUND: Bioprosthetic aortic valve function can be assessed with CMR planimetry of the anatomic orifice area and PC measurement of peak transvalvular systolic velocity. However, bioprosthetic valves can create image artifact and data dropout, which makes planimetry measures a challenge for even experienced CMR readers. METHODS: From our institutional database, we identified 38 patients who had undergone 47 paired imaging studies (CMR and Doppler) within 46 days (median 3 days). Transvalvular forward flow volume by CMR was determined by 3 methods: ascending aorta flow, transvalvular flow, and left ventricular stroke volume. PC-EOA was derived as flow divided by PC-VTI, calculated with a semiautomated MATLAB (Mathworks, Natick, Massachusetts) application for integration of the instantaneous peak transvalvular velocity. Doppler EOA was assessed by the continuity method. RESULTS: PC-EOA by all 3 flow approaches demonstrated a strong correlation with Doppler EOA (r = 0.949, 0.947, and 0.874, respectively; all p < 0.001) and revealed good agreement (bias = 0.03, 0.03, and 0.28 cm(2), respectively). With Doppler-derived EOA as the reference standard, CMR was able to correctly characterize 24 of 26 valves as normal (EOA >1.2 cm(2)), 12 of 14 possibly stenotic valves (0.8 < EOA < 1.2 cm(2)), and 5 of 7 stenotic valves (EOA <0.8 cm(2); k = 0.826). CONCLUSIONS: We describe a new CMR-based method to derive the EOA for bioprosthetic aortic valves. This method compares favorably to traditional Doppler methods and might be an important additional parameter in the evaluation of prosthetic valves by CMR, particularly when Doppler methods are suboptimal or considered discordant with the clinical presentation.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Imagem Cinética por Ressonância Magnética , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Bases de Dados Factuais , Ecocardiografia Doppler , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
14.
Am J Cardiol ; 117(2): 264-70, 2016 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-26684513

RESUMO

Although transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) are validated in quantitation of mitral regurgitation (MR), discrepancies may occur. This study assesses the agreement between TTE and CMR in MR and evaluates characteristics and clinical outcome of patients with discrepancy. From our institutional database, 70 subjects with MR underwent both TTE and CMR within 30 days (median 3 days). MR was evaluated semiquantitatively (n = 70) using a 4-grade scale and quantitatively (n = 60) with calculation of regurgitant volume (RVol) and regurgitant fraction (RF). Of the 70 subjects, qualitative assessment by TTE yielded 30 subjects with mild MR, 17 moderate, and 23 moderately severe or severe MR. Exact concordance in MR grade was seen in 50% and increased to 91% when considering concordance within one grade of severity (κ = 0.44). A modest correlation was observed for RVol and RF between both methods (r = 0.59 and 0.54, respectively, p <0.0001). Ten patients had a significant discrepancy in quantitative MR (difference in RF >20%); the frequency of secondary MR was higher (100% vs 46%; p = 0.003) in patients with discrepancy. Although interobserver variability in RF was higher with TTE compared with CMR (-5.5 ± 15% vs 0.1 ± 7.3%), patients with discrepancy were equally distributed by severity and clinical outcome without an overestimation by either method. In conclusion, there is a modest agreement between TTE and CMR in assessing MR severity. In patients with discrepancy, there is a higher prevalence of functional MR, without a consistent overestimation of MR severity by either method.


Assuntos
Ecocardiografia/métodos , Imagem Cinética por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
15.
J Atheroscler Thromb ; 22(12): 1278-86, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26269148

RESUMO

AIM: Diastolic dysfunction is a common problem in patients with obesity, hypertension, diabetes, or coronary artery disease. The purpose of this study was to evaluate the association of left ventricular diastolic dysfunction with an abnormal coronary artery calcium score (CAC score). METHODS: This study considered a cohort of patients ≥ 18 years of age with normal ejection fraction who were admitted to the hospital with chest pain. All patients underwent regadenoson myocardial perfusion stress imaging and had no evidence of ischemia or infarction. Patients then underwent cardiac CT for measurement of CAC score. Patients were excluded if they had prior history of coronary artery disease, ECG findings diagnostic of an acute coronary syndrome, an elevated troponin level, or hemodynamic instability. RESULTS: A total of 114 patients were included and 52 (45.6%) patients had echocardiographic evidence of diastolic dysfunction. Patients with diastolic dysfunction were more likely to have an abnormal calcium score (79.6% vs 20%; OR 15.10, 95% CI 5.70 to 43.85; p < 0.001). In multivariable analysis, the presence of diastolic dysfunction on echocardiogram was significantly associated with an abnormal calcium score (OR 13.82, 95% CI 5.57 to 37.37; p < 0.001) after adjusting for Framingham Risk Score or clinical risk factors (age, gender, diabetes mellitus, dyslipidemia, and obesity; OR 19.06,95% CI 4.66 to 107.97; p < 0.001). CONCLUSIONS: Our study demonstrates that left ventricular diastolic dysfunction is associated with an abnormal CAC score even after adjusting for Framingham Risk Score or clinical risk factors. Patients without known coronary artery disease that present with chest pain and have normal perfusion imaging with evidence of abnormal diastolic function on echocardiogram may warrant more thorough evaluation for coronary atherosclerotic disease with CAC score assessment.


Assuntos
Calcinose/sangue , Doença da Artéria Coronariana/patologia , Diástole , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Esquerda/patologia , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/patologia , Adulto , Idoso , Área Sob a Curva , Cálcio/metabolismo , Estudos de Coortes , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/patologia , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Curva ROC , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Troponina/sangue , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem
16.
Circ Cardiovasc Imaging ; 8(10): e003626, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26450122

RESUMO

BACKGROUND: 3D stereolithographic printing can be used to convert high-resolution computed tomography images into life-size physical models. We sought to apply 3D printing technologies to develop patient-specific models of the anatomic and functional characteristics of severe aortic valve stenosis. METHODS AND RESULTS: Eight patient-specific models of severe aortic stenosis (6 tricuspid and 2 bicuspid) were created using dual-material fused 3D printing. Tissue types were identified and segmented from clinical computed tomography image data. A rigid material was used for printing calcific regions, and a rubber-like material was used for soft tissue structures of the outflow tract, aortic root, and noncalcified valve cusps. Each model was evaluated for its geometric valve orifice area, echocardiographic image quality, and aortic stenosis severity by Doppler and Gorlin methods under 7 different in vitro stroke volume conditions. Fused multimaterial 3D printed models replicated the focal calcific structures of aortic stenosis. Doppler-derived measures of peak and mean transvalvular gradient correlated well with reference standard pressure catheters across a range of flow conditions (r=0.988 and r=0.978 respectively, P<0.001). Aortic valve orifice area by Gorlin and Doppler methods correlated well (r=0.985, P<0.001). Calculated aortic valve area increased a small amount for both methods with increasing flow (P=0.002). CONCLUSIONS: By combing the technologies of high-spatial resolution computed tomography, computer-aided design software, and fused dual-material 3D printing, we demonstrate that patient-specific models can replicate both the anatomic and functional properties of severe degenerative aortic valve stenosis.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Ecocardiografia Doppler/métodos , Modelos Cardiovasculares , Tomografia Computadorizada Multidetectores/métodos , Impressão Tridimensional , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes
17.
Methodist Debakey Cardiovasc J ; 10(3): 172-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25574345

RESUMO

Interventional echocardiography is a rapidly evolving field requiring imaging expertise. An increasing number of structural heart interventions now require real-time imaging guidance for device placement and immediate functional evaluation. Continuous 2- and 3-dimensional transesophageal echocardiography are now required by many heart teams during complex structural interventions, including percutaneous closure of atrial septal defects, left atrial appendage occlusion, transcatheter aortic valve replacement (TAVR), transcatheter repair of paravalvular regurgitation, and percutaneous mitral valve repair. In this review, we describe the role of echocardiography during the initial structural evaluation, throughout the device placement procedure, and for the assessment of acute device function and complications.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Cardiopatias/terapia , Implante de Prótese de Valva Cardíaca/métodos , Ultrassonografia de Intervenção/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/terapia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Valor Preditivo dos Testes , Dispositivo para Oclusão Septal , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa